首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Yun Fei Long  Cheng Zhi Huang   《Talanta》2007,71(5):1939-1943
The interaction of Amido black 10B (AB) with DNA in basic medium was studied in the presence of cetyltrimethylammonium bromide (CTMAB) based on the measurements of resonance light scattering (RLS), UV–vis, CD spectra, and RLS imaging. The interaction has been proved to give a ternary complex of CTMAB–DNA–AB in Britton–Robinson buffer of pH 11.55, which exhibits strong negative Cotton effect at 233.3 nm and 642.8 nm, and strong RLS signals characterized at 469 nm. Experiments showed that the enhanced RLS intensities (ΔIRLS) against the mixture of AB and CTMAB are proportional to the concentration of fish sperm DNA (fsDNA) and calf thymus DNA (ctDNA), respectively over the range of 0.03–1.0 and 0.05–1.5 μg ml−1, with the limits of determination (3σ) of 7.3 ng ml−1 for fsDNA and 7.0 ng ml−1 for ctDNA.  相似文献   

2.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

3.
A HPLC method with automated column switching and UV-diode array detection is described for the simultaneous determination of Vitamin D3 and 25-hydroxyvitamin D3 (25-OH-D3) in a sample of human plasma. The system uses a BioTrap precolumn for the on-line sample cleanup. A sample of 1 ml of human plasma was treated with 2 ml of a mixture of ethanol–acetonitrile (2:1 (v/v)). Following centrifugation, the supernatant was evaporated to dryness under a stream of dry and pure nitrogen. The residue was reconstituted in 250 μL of a solution of methanol 5 mmol l−1 phosphate buffer, pH 6.5 (4:1 (v/v)), and a 200 μl aliquot of this solution was injected onto the BioTrap precolumn. After washing during 5 min with a mobile phase constituted by a solution of 6% acetonitrile in 5 mmol l−1 phosphate buffer, pH 6.5 (extraction mobile phase), the retained analytes were then transferred to the analytical column in the backflush mode. The analytical separation was then performed by reverse-phase chromatography in the gradient elution mode with the solvents A and B (Solvent A: acetonitrile–phosphate buffer 5 mmol l−1, pH 6.5; 20:80 (v/v); solvent B: methanol–acetonitrile–tetrahydrofuran, 65:20:15 (v/v)). The compounds of interest were detected at 265 nm. The method was linear in the range 3.0–32.0 ng ml−1 with a limit of quantification of 3.0 ng ml−1. Quantitative recoveries from spiked plasma samples were between 91.0 and 98.0%. In all cases, the coefficient of variation (CV) of the intra-day and inter-day-assay precision was ≤2.80%. The proposed method permitted the simultaneous determination of Vitamin D3 and 25-OH-D3 in 16 min, with an adequate precision and sensitivity. However, the overlap of the sample cleanup step with the analysis increases the sampling frequency to five samples h−1. The method was successfully applied for the determination of Vitamin D3 and 25-OH-D3 in plasma from 46 female volunteers, ranging from 50 to 94 years old. Vitamin D3 and 25-OH-D3 concentrations in plasma were found from 4.30–40.70 ng ml−1 (19.74 ± 9.48 ng ml−1) and 3.1–36.52 ng ml−1 (7.13 ± 7.80 ng ml−1), respectively. These results were in good agreement with data published by other authors.  相似文献   

4.
Pons C  Miró M  Becerra E  Estela JM  Cerdà V 《Talanta》2004,62(5):887-895
An intelligent and versatile flow system is proposed for the in-line speciation and/or concentration of metal ions at a wide range of concentrations without requiring manifold reconfiguration. On one hand, sample enrichment strategies are accomplished using packed-bed reactors, on the other hand speciation procedures are readily performed exploiting the selective complexation of the different oxidation states with the appropriate chromogenic reagents.

The potentials of the automated methodology were evaluated using the spectrophotometric monitoring of iron as a model of chemistry. Under the optimised physical and chemical variables, linear analytical curves over the ranges 0.025–0.5 or 2.0–40 mg l−1 Fe were attained. The 3σ detection limit, the repeatability at the 0.5 mg l−1 level, the enrichment factor for a sampling volume of 10 ml, and the maximum injection throughput were 8.4 ng ml−1 Fe, 2.5%, 58.6 and 22 h−1, respectively. The flowing system was applied to the speciation analysis of iron in waters, pharmaceutical formulations and agricultural products, using ICP-OES detection as an external reference method for total iron determination.

A remarkable feature of the expert system hereby presented is the ability to decide by itself if the pre-concentration and/or oxidation of the sample zone is required.  相似文献   


5.
Flow injection determination of nitrite by fluorescence quenching   总被引:2,自引:0,他引:2  
A simple, sensitive and selective fluorimetric method for the determination of nitrite ion in waters using a merging zones flow injection system is described. The fluorimetric determination is based on the measurement of the quenching effect produced by nitrite on proflavine (3,6-diaminoacridine) fluorescence (λexem=290/519 nm).

The optimum experimental conditions were investigated by merging 0.5 ml of the sample and 0.5 ml of a solution of 5 mg l−1 of proflavine (in 0.1 M HCl) in a flow injection system, on-line connected to a flow-cell placed in the conventional sample compartment of a spectrofluorimeter. The selected carrier solution and final flow rate were 0.1 M HCl and 0.5 ml min−1, respectively. A reaction coil of 2 ml was used. As a result of the simplicity of this system, a sample throughput of about 50 samples h−1 can be achieved with the proposed methodology.

The detection limit was 1.1 ng ml−1 (3σ criterion) of nitrite. The repeatability for five sample injections containing 100 ng ml−1 of nitrite was ±0.3% and the observed linear range extended up to 400 ng ml−1. Also, the effect of interferences from various metals and anions commonly present in waters was also studied.

The method was successfully applied to the determination of low levels of nitrite in different water samples (river, fountain, tap and commercial drinking waters).  相似文献   


6.
Gold nanoparticles in size of about 10 nm was used to label goat anti-human complement 3 (anti-C3) to obtain a sensitive and selective immunoresonance scattering spectral probe for C3. It was based on the immune reaction between labeled anti-C3 and C3 in the pH 5.6 Na2HPO4–citric acid buffer solutions and in presence of polyethylene glycol (PEG). The resonance scattering (RS) intensity at 560 nm enhanced greatly with C3. Well linear relationships between the enhanced RS intensity (IRS) and the C3 concentration in the range of 8.33–200 ng ml−1 were obtained, with a detection limit of 2.8 ng ml−1 and the limit of quantification 8.51 ng ml−1 for C3. The convenient and selective and sensitive assay was applied to quantification of C3 in human sera, with satisfactory results.  相似文献   

7.
Praus P 《Talanta》2004,62(5):977-982
An isotachophoresis (ITP)–capillary zone electrophoresis (CZE) combination was used for the determination of chlorite in drinking waters. No sample preparation is needed and no interfering by other anions in tap water was observed. The reached limits of detection with conductivity detector were 0.012–0.017 mg l−1. By four-fold sample loading with a 30 μl valve, 0.005 mg l−1 of chlorite was determined with R.S.D.=3.3%. The concentrations of 0.05 and 0.20 mg l−1 were measured with R.S.D. of 2.2 and 2.7%, respectively. The recoveries of chlorite from drinking water were 96–106% in the range of 0.02–0.20 mg l−1. The R.S.D. values of migration times (inter-day) were up to 1.3%. The time for analysis is about 15 min.  相似文献   

8.
A sample solution was passed at 20 ml min−1 through a column (150×4 mm2) of Amberlite IRA-410Stron anion-exchange resin for 60 s. After washing, a solution of 0.1% sodium borohydride was passed through the column for 60 s at 5.1 ml min−1. Following a second wash, a solution of 8 mol l−1 hydrochloric acid was passed at 5.1 ml min−1 for 45 s. The hydrogen selenide was stripped from the eluent solution by the addition of an argon flow at 150 ml min−1 and the bulk phases were separated by a glass gas–liquid separator containing glass beads. The gas stream was dried by passing through a Nafion® dryer and fed, via a quartz capillary tube, into the dosing hole of a transversely heated graphite cuvette containing an integrated L’vov platform which had been pretreated with 120 μg of iridium as trapping agent. The furnace was held at a temperature of 250°C during this trapping stage and then stepped to 2000°C for atomization. The calibration was performed with aqueous standards solution of selenium (selenite, SeO32−) with quantification by peak area. A number of experimental parameters, including reagent flow rates and composition., nature of the gas–liquid separator, nature of the anion-exchange resin, column dimensions, argon flow rate and sample pH, were optimized. The effects of a number of possible interferents, both anionic and cationic were studies for a solution of 500 ng 1−1 of selenium. The most severe depressions were caused by iron (III) and mercury (II) for which concentrations of 20 and 10 mg  1−1 caused a 5% depression on the selenium signal. For the other cations (cadmium, cobalt, copper, lead,. magnesium, and nickel) concentrations of 50–70 mg 1−1 could be tolerated. Arsenate interfered at a concentration of 3 mg−1, whereas concentrations of chloride, bromide, iodide, perchlorate, and sulfate of 500–900 mg l−1 could be tolerated. A linear response was obtained between the detection limit of 4 ng 1−1, with a characteristic mass of 130 pg. The RSDs for solutions containing 100 and 200 ng 1−1 selenium were 2.3% and 1.5%, respectively.  相似文献   

9.
A new po1y(acrylphenylamidrazone phenylhydrazide) chelating fiber is synthesized from polyacrylonitrile fiber and used for preconcentration and separation of trace Ga(III), In(III), Bi(III), V(V) and Ti(IV) from solution (5–50 ng ml−1 Ti(IV) or V(V) and 50–500 ng ml−1 Ga(III), In (III) or Bi(III) in 1000–100 ml of solution can be enriched quantitatively by 0.15 g of fiber at a 4 ml min−1 flow rate in the pH range 5–7 with recoveries >95%). These ions can be desorbed quantitatively with 20 ml of 4 M hydrochloric acid at 2 ml min−1 from the fiber column. When the fiber which had been treated with concentrated hydrochloric acid and washed with distilled water until neutral was reused eight times, the recoveries of the above ions by enrichment were still >95%. Two-hundred-fold to 10 000-fold excesses of Cu(II), Zn(II), Ca(II), Mn(II), Cr(III), Fe(III), Ba(II) and Al(III) caused little interference in the determination of these ions by inductively coupled plasma-atomic emission spectrometers (ICP-AES). The relative standard deviations for enrichment and determination of 50 ng ml−1 Ga, In or Bi and 10 ng ml−1 V or Ti are in the range 1.2–2.7%. The contents of these ions in real solution samples determined by this method were in agreement with the certified values of the samples with average errors <3.7%.  相似文献   

10.
A new flow injection procedure for an assay of Fe(III) by using salicylate obtained from antipyretic powder, which is a cheap and easily available reagent, is proposed. A red complex was continuously monitored by a laboratory-made green LED colorimeter. A linear calibration was obtained in the range of 1–20 mg Fe l−1 with a detection limit of 0.5 mg Fe l−1 and R.S.D.s of 1.4–5.4% (n=3, for 1–20 mg Fe l−1). The new procedure was applied to assay iron contents in pharmaceutical preparations. The results were in good agreement with those of the USP standard method.  相似文献   

11.
A pervaporation-flow injection (PFI) method is described for the analysis of cyanide in the presence of sulfide. The interfering sulfide ion in the injected sample is precipitated on-line using an acidified lead nitrate reagent solution before the donor stream enters the pervaporation cell. Using amperometric detection at a silver electrode set at −50 mV (vs Ag/AgCl), linear calibration was obtained in the range 0.02–100.0 mg l−1 with a detection limit of 1.0 μg l−1. Sample throughput was of the order of 12–15 h−1. When the method was applied to the analysis of synthetic samples, there was no significant interference from sulfide at concentrations up to 50 mg l−1. Thiocyanate did not interfere at levels up to 1000 mg l−1. When applied to industrial samples containing sulfide and thiocyanate ions where the cyanide ions are predominantly complexed with various metal ions the PFI method was found to give results close to those obtained by standard distillation methods for weak acid dissociable (WAD) cyanide.  相似文献   

12.
A simple procedure was developed for the speciation of inorganic arsenic by electrochemical hydride generation atomic absorption spectrometry (EcHG–AAS), without pre-reduction of As(V). Glassy carbon was selected as cathode material in the flow cell. An optimum catholyte concentration for simultaneous generation of arsine from As(III) and As(V) was 0.06 mol l−1 H2SO4. Under the optimized conditions, adequate sensitivity and difference in ratio of slopes of the calibration curves for As(III) and As(V) can be achieved at the electrolytic currents of 0.6 and 1 A. The speciation of inorganic arsenic can be performed by controlling the electrolytic currents, and the concentration of As(III) and As(V) in the sample can be calculated according to the equations of absorbance additivity obtained at two selected electrolytic currents. The calibration curves were linear up to 50 ng ml−1 for both As(III) and As(V) at 0.6 and 1 A. The detection limits of the method were 0.2 and 0.5 ng ml−1 for As(III) and As(V) at 0.6 A, respectively. The relative standard deviations were of 2.1% for 20 ng ml−1 As(III) and 2.5% for 20 ng ml−1 As(V). The method was validated by the analysis of human hair certified reference material and successfully applied to speciation of soluble inorganic arsenic in Chinese medicine.  相似文献   

13.
A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin–mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at −0.25 V and −0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l−1 (1.72×10−7 mol l−1) and 40 mg l−1 (6.88×10−5 mol l−1). A 3σ limit of detection of 32 μg l−1 (55 nmol l−1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated.  相似文献   

14.
Polystyrene–divinylbenzene (8%) has been functionalised by coupling it through an ---N=N--- group with 6-mercaptopurine. The resulting chelating resin has been characterised by using elemental analysis, thermogravimetric analysis and infrared spectra. The resin is highly selective for Hg(II) and Ag(I) and has been used for preconcentrating Hg(II) and Ag(I) prior to their determination by atomic absorption spectrometry. The maximum sorption capacity for Hg(II) and Ag(I) was found to be 1.74 and 0.52 mmol g−1, respectively, over the pH range 5.5–6.0. The calibration range for Hg(II) was linear up to 10 ng ml−1 with a 3σ detection limit of 0.02 ng ml−1; the calibration range for Ag(I) was linear up to 5 μg ml−1 with a detection limit of 29 ng ml−1. The recoveries of the metals were found to be 99.7±3.8 and 101.3±4.1% at the 95% confidence level for both Hg(II) and Ag(I). In column operation, it has been observed that Hg(II) and Ag(I) in trace quantities can be selectively separated from geological, medicinal and environmental samples.  相似文献   

15.
Development of an enzyme-linked immunosorbent assay for pentachlorophenol   总被引:5,自引:0,他引:5  
Pentachlorophenol (PCP) is a hazardous pollutant with toxicity and potential carcinogenic properties being a serious threat to the environment. In this work, the development of an immunoassay for PCP is presented. A hapten was synthesised and conjugated to protein for rabbit immunisation. Three polyclonal antibodies were obtained and the best results were achieved in the antibody-coated format using antiserum R3. Calibration range was 0.3–30.5 ng ml−1, with an average I50 value of 2.9 ng ml−1 and a detection limit of 0.1 ng ml−1. The specificity of the assay was tested against PCP structurally related compounds. The method is highly specific for PCP and shows low cross-reactivity (CR) for chlorine-containing phenols, nitrophenols, benzenic and piridinic compounds. The good recoveries achieved with different water samples indicate that this assay can be a good alternative method for the determination of PCP in this kind of samples.  相似文献   

16.
Zhou X  Xing D  Zhu D  Tang Y  Jia L 《Talanta》2008,75(5):1300-1306
Enrofloxacin (ENR) is a fluoroquinolone developed exclusively for the use in veterinary practice for the treatment of respiratory and gastrointestinal infections, and ciprofloxacin (CIP) is its main active metabolite. Their contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. We developed a sensitive and rapid method for the determination of ENR and CIP by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. The method is based on the detection of aliphatic tertiary or secondary amino moieties in ENR and CIP with end-column tris(2,2-bipyridyl)ruthenium(II) electrochemiluminescence. Parameters that affect separation and detection were optimized. Under the optimized conditions, the calibration functions were linear in the range of 0.03–1 μg ml−1 for ENR and 0.05–1.2 μg ml−1 for CIP. The detection limits of ENR and CIR were 10 ng ml−1 and 15 ng ml−1, respectively, based on the signal-to-noise ratio of 3. The relative standard derivations of the peak height and the migration time for ENR and CIP were less than 4.13%. The developed method was successfully applied to determine ENR and CIP in milk with a solid-phase extraction procedure.  相似文献   

17.
A sensitive method for the post-column reaction detection of organophosphorus pesticides is described. The method relies on photolysis of the organocompounds by irradiation with a low-pressure mercury lamp (main spectral line, 254 nm) in the presence of peroxydisulfate. The resultant orthophosphate was reacted with molybdate to form molybdophosphoric acid, which subsequently reacted with thiamine to generate thiochrome. Finally, the fluorescence intensity of thiochrome was measured at 440 nm with excitation at 375 nm. Factors affecting the rate of these reactions were optimized so that its contribution to the total band-broadening was negligible.

This detection system was used for the determination of phosphate, acephate and methamidophos, which were separated on an ODS column by isocratic reversed phase chromatography with acetonitrile–water as the mobile phase. A linear relationship between analyte concentration and peak area was obtained within the range 0.016–7.0 μg ml−1 with correlation coefficients greater than 0.9995 and detection limits between 4 and 12 ng ml−1. Intra- and inter-day precision values of about 1.2% R.S.D. (n = 10) and 2.1% R.S.D. (n = 30), respectively, were obtained.

Pesticide residues below ng ml−1 levels could be determined in environmental waters when a preconcentration device was coupled on-line with the HPLC system. Detection limits as low as 0.01 ng ml−1 were achieved for only 250 ml of sample. In the analyses of vegetables and grains, the detection limit was about 1 μg kg−1.  相似文献   


18.
Solid-phase spectrophotometry (SPS) technique, in the visible region, was used for the spectrophotometric determination of ascorbic acid based on the reducing effect on iron(III) ion, followed by formation of the iron(II)-ferrozine chelate. The chelate is easily sorbed on a dextran-type anion-exchange gel and the absorbance of the resin at 567 and 800 nm, packed in a 1 mm cell, is measured directly. The apparent molar absorptivity using 100 ml of sample was 2.1×107 l mol−1 cm−1 and it allowed the determination of ascorbic acid in the range 5–90 ng ml−1; the detection limit was 0.91 ng ml−1 and the RSD 0.91% for a concentration of 50 ng ml−1 of ascorbic acid (n=10). The proposed method permits a highly sensitive and selective determination of ascorbic acid without any preconcentration and it has been satisfactorily applied for its determination in fruit juices, pharmaceuticals, urine and conservative liquids.  相似文献   

19.
The fact that β-carotene might be the protective factor against various cancers, suggests the need for a rapid reliable assay for this potential marker. We have proposed the method for selective, precise and simple profiling of carotenoids as well as for simultaneous ultrasensitive assaying of trans-β-carotene (TBC) and cis-β-carotene(s) (CBC) in five vegetable oils. The oil samples diluted 20 or 100 times were directly injected and analysed by means of the isocratic non-aqueous reversed-phase high-performance liquid chromatography (HPLC) combined with ultrasensitive thermal lens detection (TLS).

Elution of TBC was followed by CBC; both were identified and determined in olive, safflower, sesame, wheat germ and linseed oil by standard addition method. The presence of lutein/zeaxanthin, some xanthophyll and/or early eluting carotene may be also presumed in the aforementioned oils. The examined oils showed different and characteristic carotenoid/carotene profiles and characteristic TBC-to-CBC ratios. Both analytes were selectively detected in the presence of palmitic, oleic, linoleic, linolenic and stearic acid, β-sitosterol and --tocopherol. This extends applicability of the method to other vegetable oils as well.

Favourable analytical performances (high sensitivity, low limits of detection (LODs) and wide linearity span) enabled the direct analyses of highly diluted oils. This resulted in several major benefits of the proposed method, among which (i) reduced risk of stationary phase deterioration, (ii) avoiding the risk of carotenoids transformations and (iii) substantial labour and time savings. The TBC and CBC in diluted vegetable oils were reliably measured at ultratrace level (1–26 ng ml−1) with the S/N ratio ranging from 4 to 140 and precisely determined (imprecision 0.4–8.3%). The concentrations of TBC+CBC estimated in the original oils were as follows: 90.5+51.2 ng ml−1 in sesame oil, 146.0+164 ng ml−1in safflower oil, 464.6+206.1 ng ml−1in linseed oil, 453.7+143.3 ng ml−1 in olive oil and 2.31+2.63 μg ml−1 in wheat germ oil. The characteristic and variable portion of TBC within total β-carotene may serve as a reliable indicator of both, quality and authenticity of the vegetable oil. The HPLC–TLS assay proposed may therefore be successfully applied in nutritional, agricultural and epidemiological studies.  相似文献   


20.
Wu XZ  Liu P  Pu QS  Sun QY  Su ZX 《Talanta》2004,62(5):918-923
A amino-terminated G 4.0 dendrimer-like polyamidoamine (PAMAM) immobilized silica gel (PAMAMSG) was prepared with a divergent method by repeating two processes: (1) Michael addition of methyl acrylate (MA) to surface amino groups; and (2) amidation of the resulting esters with ethylenediamine (EDA) from γ-aiminopropyl silica gel (APSG) core. It was then used for the first time as microcolumn packing for the flame atomic absorption spectrometry (FAAS) determination of trace or ultra trace Pd(II), after flow injection (FI) online preconcentration and separation process. A limit of detection (LOD) of 3.9 ng ml−1 was achieved when 0.200 μg ml−1 Pd(II) was preconcentrated in 0.2 mol l−1 HCl medium with a sampling flow rate of 6.0 ml min−1 for 60 s and the relative standard deviation (R.S.D.) was 1.7%. The proposed method was successfully used for the determination of Pd in two metallurgical samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏