首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An inductively coupled plasma mass spectrometer (ICP-MS) equipped with a dynamic reaction cell™ (DRC) was used for the determination of Ca, Fe and Zn in milk powder samples. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise (S/N) ratio. The potentially interfering 40Ar+, 40Ar16O+, 40Ca16O+, 48Ca16O+ and 32S16O16O+ at the masses m/z 40, 56 and 64 were reduced in intensity significantly by using CH4 as the reaction cell gas in the DRC while a q-value of 0.7 was used. The limits of detection for 40Ca, 56Fe and 64Zn estimated from the external calibration graphs were 1, 0.01 and 0.001 ng ml−1, respectively, which correspond to 1000, 10 and 1 ng g−1 in the original powder sample. This method was applied to the determination of Ca, Fe and Zn in NIST SRM 1549 non-fat milk powder and two milk powder samples purchased locally. The results for the reference sample agreed satisfactorily with the reference values; the accuracy of the determination was better than 3.8, 18 and 2.2% for Ca, Fe and Zn, respectively. The results for which no reference value was available were also found to be in good agreement between different isotopes. Precision (R.S.D.) between sample replicates was better than 10% for all the determinations.  相似文献   

2.
A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry (HPLC–MS/MS) has been developed and validated for the determination of cilnidipine, a relatively new calcium antagonist, in human plasma. The reversed-phase chromatographic system was interfaced with a TurboIonSpray (TIS) source. Nimodipine was employed as the internal standard (IS). Sample extracts following protein precipitation were injected into the HPLC–MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of CH3OH and NH4Ac (96:4, v/v). The ions were detected by a triple quadrupole mass spectrometric detector in the negative mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 491.2 → 122.1 and m/z 417.1 → 122.1 for cilnidipine and for the IS, respectively. The analysis time for each run was 3.0 min. The calibration curve fitted well over the concentration range of 0.1–10 ng mL−1, with the regression equation Y = (0.103 ± 0.002)X + (0.014 ± 0.003) (n = 5), r = 0.9994. The intra-day and inter-day R.S.D.% were less than 12.51% at all concentration levels within the calibration range. The recoveries were between 92.71% and 97.64%. The long-term stability and freeze-thaw stability were satisfying at each level. The present method provides a modern, rapid and robust tool for pharmacokinetic studies of cilnidipine.  相似文献   

3.
When inductively coupled plasma mass spectrometry (ICP-MS) is used for the detection of 52Cr (83.8%) species in ion chromatography (IC), interference from polyatomic ions such as 40Ar12C+ and 35Cl16O1H+, often occurs due to their mass at m/z 52. To address the issue, an octopole reaction system (ORS) in ICP-MS, including He and H2 modes, was used to determine whether the background and interference from polyatomic ions could be reduced in the detection of 52Cr. Compared to standard mode, the polyatomic ions were reduced by either He or H2; for example, more than 97 and 98% of 35Cl was removed using a He and H2 tune, respectively. However, the detection sensitivity for 52Cr was decreased, for example, the sensitivity was 27.95 and 67.02% of the standard mode for Cr(EDTA)2using a He and H2 tune, respectively. The H2 tune is recommended for the detection of 52Cr at a flow rate of 2.0 mL/min with detection limits in the range of 0.2–0.4 μg/L. The developed method was used to measure chromium speciation in waters containing high concentration of chloride.  相似文献   

4.
Guo R  Zhou Q  Cai Y  Jiang G 《Talanta》2008,75(5):1394-1399
A new method is developed for the determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) in sewage sludge samples. The analytes in sewage sludge samples are extracted by methanol and formic acid, cleaned by C18 solid-phase extraction, then separated, identified and quantitated by liquid chromatography/quadrupole time-of-flight mass spectrometry (LC–QTOF-MS). A C18 column (150 mm × 2.1 mm, 3.5 μm) with gradient elution of MeOH–H2O (60:40) containing 5 mmol/L ammonium acetate and MeOH–H2O (80:20) is used for the chromatographic separation. [M−K] ions at m/z 498.93 for PFOS and [M−COOH] ion at m/z 368.97 for PFOA are selected for QTOF-MS in the negative electrospray ionization mode. The detection limits for PFOS and PFOA in sewage sludge samples are 0.5 and 0.8 ng/g, respectively. The spiked recoveries are in the range of 85–114 and 71–98% for PFOS and PFOA, respectively. The proposed method is successfully applied to the analysis of PFOS and PFOA in 16 sewage sludge samples from China. PFOS and PFOA are detected in most sewage sludge samples and the concentrations of PFOS and PFOA are up to 5383 and 4780 ng/g (oven dry weight), respectively.  相似文献   

5.
The new strong anion exchanger (PUFIX) from polyurethane foam was prepared by coupling of the primary amine of the foam matrix with ethyl iodide. PUFIX was characterized using different tools (IR spectra, elemental analysis, density and thermal analysis). The sorption properties of the new anion exchanger (PUFIX) and chromatographic behaviour for separation and determination of palladium(II) ions at low concentrations from aqueous iodide or thiocyanate media were investigated by a batch and dynamic processes. The maximum sorption of Pd(II) was in the pH range of 0.3–2. The kinetics of sorption of the Pd(II) by the PUFIX was found to be fast with average values of half-life of sorption (t1/2) of 3.32 min. The variation of the sorption of Pd(II) with temperature gives average values of ΔH, ΔS, ΔG and ΔE to be −38.3 kJ mol−1, −100.7 J K−1 mol−1, −8.3 and 11.8 kJ mol−1, respectively. The sorption capacity of PUFIX was 1.69 mmol g−1 for Pd(II), preconcentration factors of values ≈250 and the recovery 99–100% were achieved (R.S.D. ≈ 1.24%). The lower detection limit, 1.28 ng mL−1 was evaluated using spectrophotometric method (R.S.D. ≈ 2.46%).  相似文献   

6.
A novel amino-functionalized polymer was synthesized using 3-(trimethoxysilyl) propyl amine (TMSPA) as precursor and hydroxy-terminated polydimethylsiloxane (OH-PDMS) by sol–gel technology and coated on fused-silica fiber. The synthesis was designed in a way to impart polar moiety into the coating network. The scanning electron microscopy (SEM) images of this new coating showed the homogeneity and the porous surface structure of the film. The efficiency of new coating was investigated for headspace solid-phase microextraction (SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency such as extraction temperature, extraction time, ionic strength and pH was investigated and optimized. In order to improve the separation efficiency of phenolic compounds on chromatography column all the analytes were derivatized prior to extraction using acetic anhydride at alkaline condition. The detection limits of the method under optimized conditions were in the range of 0.02–0.05 ng mL−1. The relative standard deviations (R.S.D.) (n = 6) at a concentration level of 0.5 ng mL−1 were obtained between 6.8 and 10%. The calibration curves of chlorophenols showed linearity in the range of 0.5–200 ng mL−1. The proposed method was successfully applied to the extraction from spiked tap water samples and relative recoveries were higher than 90% for all the analytes.  相似文献   

7.
Leal LO  Semenova NV  Forteza R  Cerdà V 《Talanta》2004,64(5):1335-1342
A new multisyringe flow injection system for inorganic arsenic determination at trace levels by hydride generation-atomic fluorescence spectrometry (HGAFS) is presented. Preconcentration on a solid-phase was carried out using a column packed with an anion-exchange resin (Amberlite IRA-410). The reagents are dispensed to the system using a multisyringe burette coupled with two multi-port selection valves.

Different parameters were changing in order to make the system as effective as possible. An analytical curve was obtained for arsenic determination between 50 and 2000 ng l−1. This new approach improved five times the sensitivity over a MSFIA–HGAFS technique developed previously by the authors. Detection limit of the proposed technique was (3σb/S) of 30 ng l−1. The relative standard deviation (R.S.D.) of As at 1 μg l−1 was 4.8% (n=7). A sample throughput of 10 h−1 has been achieved. The proposed method has been applied to different reference solid and water materials with satisfactory results.  相似文献   


8.
Li ZX  Guo YA 《Talanta》2005,65(5):1318-1325
A new and sample technique for the simultaneous determination of trace arsenic, antimony, bismuth and selenium in biologic samples by hydride generation-four-channel nondispersive atomic fluorescence spectrometry was development. The conditions of instrumentation and hydride generation of arsenic, antimony, bismuth and selenium were optimized. For reducing hexavalent Se to the tetravalent state was to heat the sample with 6 mol l−1 HCl, and then pre-reducing pentavalent As and Sb to the trivalent state was achieved by the addition of 0.05 mol l−1 thiourea. The interferences of coexisting ions were evaluated. Under optimal conditions, the detection limits for As, Sb, Bi and Se were determined to be 0.03, 0.04, 0.04 and 0.03 ng ml−1, respectively. The precision for seven replicate determinations at the 5 ng ml−1 of As, Sb, Bi and Se were 0.9, 1.2, 1.3 and 1.5% (R.S.D.), respectively. The proposed method was successfully applied to the simultaneous determination of As, Sb, Bi and Se in a series of Chinese certified biological reference materials using simple aqueous standard calibration technique, the results obtained are in good agreement with the certified values.  相似文献   

9.
Ding L  Luo XB  Tang F  Yuan JB  Guo M  Yao SZ 《Talanta》2008,74(5):1344-1349
Dehydroandrographolide, andrographolide and geniposide are the main active constituents of many herbal medicines, e.g., Fructus gardeniae, Common Andrographis Herb. They are used as the markers to control the quality of such herbal medicines and their herbal preparations. In this paper, a simple and sensitive high-performance liquid chromatographic (HPLC) method coupled with photodiode array detection (DAD) and electrospray mass spectrometry (ESI/MS) were developed to determine the three compounds simultaneously in extracts of medicinal herbs and herbal preparations produced by different companies. The extracts were separated on a C18 reversed phase HPLC column, with a gradient solvent system, the time for the separation of the three target analytes was 10 min. The abundance ions were recorded using selected ion monitoring (SIM) mode with m/z 297.3, 297.3 and 411.1 for dehydroandrographolide, andrographolide and geniposide, respectively. The limit of detection for dehydroandrographolide, andrographolide and geniposide were 20, 30 and 150 ng mL−1, respectively. The proposed method was successfully applied to the determination of the contents of the compounds in related to medicinal herbs and preparations.  相似文献   

10.
《Analytica chimica acta》2004,520(1-2):117-124
Changes in fresh weight, total protein amounts (Bradford’s method), cadmium concentration (DPASV) and glutathione content (HPLC/MS) were studied in maize kernels cultivated for 5 days at three different cadmium concentrations (0, 10 and 100 μmol l−1 CdCl2). A highly sensitive HPLC/MS method was used for the determination of glutathione on a reversed-phase Atlantis dC18 chromatographic column (150 mm×2.1 mm, 3 μm particle size). An isocratic mode with acetonitrile–0.01% TFA (5:95, flow rate 0.1 ml min−1 and 30 °C) was applied. The m/z spectra and the data for the selected ion monitoring (SIM) mode were recorded at m/z for glutathione 308→179. Cadmium concentration was measured by a differential pulse adsorptive stripping voltammetry (DPASV) after deposition on a hanging mercury drop electrode (HMDE) at potential −0.7 V (accumulation time 180 s, acetate buffer of pH 3.6, 22 °C). An AUTOLAB with a VA-Stand 663 and a three-electrode system consisting of the HMDE as a working electrode with area 0.4 mm2, an Ag/AgCl/3 mol l−1 KCl as a reference electrode and a Pt-wire as an auxiliary electrode was employed. The maize kernels exposed to the highest cadmium concentration (100 μmol l−1) germinated formerly and much better. A rapid increase of the fresh weight probably relates with more intensive uptake of water in order to decrease cadmium concentration. An intensive preservation of homeostasis of Cd2+ ions in the germinating plants by defending mechanisms might explain differences of uptake rate of cadmium. The linear increase of GSH content with the exposure time at all studied concentration suggests the defending mechanisms might be triggered by concentrations of a heavy metal.  相似文献   

11.
Commercial non-food packaging materials of four different matrices (paper, low density polyethylene (LDPE), polyethylene-polypropylene (PE-PP) and high density polyethylene (HDPE)) were examined for the content of Cr, Ni, Cu, Zn, As, Mo, Cd, Sb, Ba, Hg, Tl, Pb and U. The examined samples (0.17–0.35 g) were digested in HNO3 and H2O2 (papers, LDPE and PE-PP) and in HNO3, H2SO4 and H2O2 (HDPE) using microwave assisted high pressure system. The inductively coupled plasma-time of flight-mass spectrometry (ICP-TOFMS) has been employed as the detection technique. All measurements were carried out using internal standardization. Yttrium and rhodium (50 ng g−1) were used as internal standards. The detection and quantification limits obtained were in the range of 0.005 ng g−1 (52Cr) to 0.51 ng g−1 (66Zn) and 0.015 μg g−1 (52Cr) to 2.02 μg g−1 (66Zn) of dry mass, respectively. The evaluated contents (mg kg−1) of particular elements in the examined materials were as follows: 0.22–219; <1.05–9.03; 1.25–112; <2.02–449; <0.98–<1.30; <0.36–2.06; <0.29–113; <0.22–44.1; <0.06–57.4; <0.66–<0.88; <0.08–0.24; <0.13–1222 and <0.08–0.44 for Cr, Ni, Cu, Zn, As, Mo, Cd, Sb, Ba, Hg, Tl, Pb and U, respectively.  相似文献   

12.
By HG-AFS, a new method was proposed for simultaneous determination of total arsenic and total selenium existed in the Chinese medicinal herbs in tartaric acid medium. The effects of analytical conditions and coexisting ions on the fluorescence signal intensity of analytes were investigated. The proposed method was provided with linear response ranges above 22 μg l−1 for As and 44 μg l−1 for Se, and the detection limits of 0.13 and 0.12 μg l−1 were obtained for As and Se respectively. The recoveries of 93.8–96.1% for As and 95.3–99.1% for Se, and the precision of 1.2–3.8% and 2.4–5.3% (R.S.D., n = 8) respectively, were obtained via simultaneous determined four samples of Chinese medicinal herbs and three certified botanic reference materials successfully. The proposed method has the advantages of simple operation, high sensitivity and high efficiency.  相似文献   

13.
A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-llosvay reaction. The formed azo dye was measured at 543 nm. The influence of reagent concentration and manifold parameters were studied. Nitrite, nitrate and ammonium can be determined within the range of 0.02–1.60 μg mL−1, 0.02–1.60 μg mL−1 and 0.05–1.40 μg mL−1, respectively. R.S.D. values (n = 10) were 2.66; 1.41 and 3.58 for nitrate, nitrite and ammonium, respectively. This procedure allows the determination and speciation of inorganic nitrogen species in soils with a single injection in a simple way, and high sampling rate (18 h−1). Detection limits of 0.013, 0.046 and 0.047 μg mL−1were achieved for nitrate, nitrite and ammonium, respectively. In comparison with others methods, the proposed one is more simple, it uses as single chromogenic reagent less injection volume (250 mL in stead of 350 mL) and it has a higher sampling rate.  相似文献   

14.
A sample solution was passed at 20 ml min−1 through a column (150×4 mm2) of Amberlite IRA-410Stron anion-exchange resin for 60 s. After washing, a solution of 0.1% sodium borohydride was passed through the column for 60 s at 5.1 ml min−1. Following a second wash, a solution of 8 mol l−1 hydrochloric acid was passed at 5.1 ml min−1 for 45 s. The hydrogen selenide was stripped from the eluent solution by the addition of an argon flow at 150 ml min−1 and the bulk phases were separated by a glass gas–liquid separator containing glass beads. The gas stream was dried by passing through a Nafion® dryer and fed, via a quartz capillary tube, into the dosing hole of a transversely heated graphite cuvette containing an integrated L’vov platform which had been pretreated with 120 μg of iridium as trapping agent. The furnace was held at a temperature of 250°C during this trapping stage and then stepped to 2000°C for atomization. The calibration was performed with aqueous standards solution of selenium (selenite, SeO32−) with quantification by peak area. A number of experimental parameters, including reagent flow rates and composition., nature of the gas–liquid separator, nature of the anion-exchange resin, column dimensions, argon flow rate and sample pH, were optimized. The effects of a number of possible interferents, both anionic and cationic were studies for a solution of 500 ng 1−1 of selenium. The most severe depressions were caused by iron (III) and mercury (II) for which concentrations of 20 and 10 mg  1−1 caused a 5% depression on the selenium signal. For the other cations (cadmium, cobalt, copper, lead,. magnesium, and nickel) concentrations of 50–70 mg 1−1 could be tolerated. Arsenate interfered at a concentration of 3 mg−1, whereas concentrations of chloride, bromide, iodide, perchlorate, and sulfate of 500–900 mg l−1 could be tolerated. A linear response was obtained between the detection limit of 4 ng 1−1, with a characteristic mass of 130 pg. The RSDs for solutions containing 100 and 200 ng 1−1 selenium were 2.3% and 1.5%, respectively.  相似文献   

15.
Solid-phase spectrophotometry (SPS) technique, in the visible region, was used for the spectrophotometric determination of ascorbic acid based on the reducing effect on iron(III) ion, followed by formation of the iron(II)-ferrozine chelate. The chelate is easily sorbed on a dextran-type anion-exchange gel and the absorbance of the resin at 567 and 800 nm, packed in a 1 mm cell, is measured directly. The apparent molar absorptivity using 100 ml of sample was 2.1×107 l mol−1 cm−1 and it allowed the determination of ascorbic acid in the range 5–90 ng ml−1; the detection limit was 0.91 ng ml−1 and the RSD 0.91% for a concentration of 50 ng ml−1 of ascorbic acid (n=10). The proposed method permits a highly sensitive and selective determination of ascorbic acid without any preconcentration and it has been satisfactorily applied for its determination in fruit juices, pharmaceuticals, urine and conservative liquids.  相似文献   

16.
Multielemental speciation of As, Se, Sb and Te by HPLC-ICP-MS   总被引:2,自引:0,他引:2  
Guerin T  Astruc M  Batel A  Borsier M 《Talanta》1997,44(12):2201-2208
An anion exchange HPLC-ICP-MS procedure allowing the simultaneous multielemental speciation analysis of arsenic, selenium, antimony and tellurium has been developed. Four arsenic species (AsIII, AsV, monomethylarsonic acid and dimethylarsinic acid), two selenium species (SeIV and SeVI) may be determined in a single run as well as one antimony (SbV) and one tellurium species (TeVI). Alternatively Sb and/or Te may be used as internal standards for As and Se speciation studies. Optimisation of ICP-MS conditions led to satisfactory relative (0.01 (SbV) to 1.8 (SeVI) ng ml−1) and absolute detection limits (1–180 pg). Reproducibility ranged from 3.1 to 5.6% and the linearity was verified in the 0–200 ng ml−1 range.  相似文献   

17.
Cao Q  Li S  He C  Li K  Liu F 《Analytica chimica acta》2007,590(2):187-194
Based on aqueous two-phase system (ATPS) of poly(ethylene glycol) (PEG)–(NH4)2SO4, a simple pretreatment approach was developed for the extraction and determination of papaverin in pericarpium papaveris. The influence factors on phase behavior of the ATPS and partition behavior of papaverin was investigated, and partition mechanism based on the hydrophobic interaction between PEG and analyte molecules was proposed. Under the optimal conditions, the extraction efficiencies for papaverin were 93–96%, and the recoveries of the added standard were 97–106% with relative standard deviations of 1.8–2.5%. Combined with a high-performance liquid chromatography (HPLC) method, this extraction technique has been successfully applied to the determination of papaverin in pericarpium papaveris with the detection limit of 2 ng mL−1 and the linear range of 0.10–10 μg mL−1. Compared with the conventional liquid–liquid extraction or solid-phase extraction, this method was more environmentally benign, more cost effective and much simpler due to the direct injection of the upper phase into HPLC system.  相似文献   

18.
Zhihua Wang  Shujun Wang  Min Cai 《Talanta》2007,72(5):1723-1727
A graphite furnace atomic absorption spectrometry (GFAAS) method with optical temperature control for the determination of trace cadmium in paint samples is described. Optical temperature control was superior in many respects to current temperature control. The sensibility increased by 60%, the linear range widened by 60%, and the life of graphite tube showed a 200–300% increase because atomization temperature was lowered distinctly and atomization time was shortened. Use of lanthanum chloride as a matrix modifier was investigated. The linear range of calibration curve was 0–24 ng mL−1. The detection limit was 9.6 ng L−1. The characteristic mass was 3.0 pg. The method also resulted in excellent reproducibility (≤2.5% R.S.D.) at such low levels, and the recovery of added cadmium in paint samples was from 94.6% to 102%. This method is readily applicable to the determination of cadmium in paint samples.  相似文献   

19.
A procedure for arsenic species fractionation in alga samples (Sargassum fulvellum, Chlorella vulgaris, Hizikia fusiformis and Laminaria digitata) by extraction is described. Several parameters were tested in order to evaluate the extraction efficiency of the process: extraction medium, nature and concentration (tris(hydroxymethyl)aminomethane, phosphoric acid, deionised water and water/methanol mixtures), extraction time and physical treatment (magnetic stirring, ultrasonic bath and ultrasonic focussed probe). The extraction yield of arsenic under the different conditions was evaluated by determining the total arsenic content in the extracts by ICP-AES. Arsenic compounds were extracted in 5 mL of water by focussed sonication for 30 s and subsequent centrifugation at 14,000 × g for 10 min. The process was repeated three times. Extraction studies show that soluble arsenic compounds account for about 65% of total arsenic.

An ultrafiltration process was used as a clean-up method for chromatographic analysis, and also allowed us to determine the extracted arsenic fraction with a molecular weight lower than 10 kDa, which accounts for about 100% for all samples analysed.

Speciation studies were carried out by HPLC–ICP-AES. Arsenic species were separated on a Hamilton PRP-X100 column with 17 mM phosphate buffer at pH 5.5 and 1.0 mL min−1 flow rate. The chromatographic method allowed us to separate the species As(III), As(V), MMA and DMA in less than 13 min, with detection limits of about 20 ng of arsenic per species, for a sample injection volume of 100 μL. The chromatographic analysis allowed us to identify As(V) in Hizikia (46 ± 2 μg g−1), Sargassum (38 ± 2 μg g−1) and Chlorella (9 ± 1 μg g−1) samples. The species DMA was also found in Chlorella alga (13 ± 1 μg g−1). However, in Laminaria alga only an unknown arsenic species was detected, which eluted in the dead volume.  相似文献   


20.
Palladium loaded calcium-hydroxyapatite, Pd(z)/CaHAp, and calcium-fluoroapatite, Pd(z)/CaFAp, were synthesised and characterised by TEM, XRD, IR and UV–vis–NIR spectroscopies. Introduction of palladium does not change the structure of CaHAp and CaFAp. The average size of PdO particles was found to be around 4–5 nm on Pd(1)/CaHAp but larger (6–7 nm) on Pd(1)/CaFap. The acid–base properties of the supports and of the catalysts were studied using butan-2-ol conversion. On CaHAp and CaFAp, the butenes yield (dehydration reaction) is very low either in the absence or in the presence of oxygen. The methyl ethyl ketone yield (dehydrogenation reaction) is significant only in the presence of oxygen and higher over CaFAp. Conversely, the performances of Pd(z)/CaHAp are better than those of Pd(z)/CaFAp below 180 °C. Above 180 °C, buta-2-ol combustion is favoured on Pd/CaHAp but not on Pd/CaFAp.

In methane oxidation, Pd(z)/CaHAp showed also a much larger activity than Pd(z)/CaFAp. On 2 wt% Pd loaded CaHAp, the methane oxidation reaches a conversion of almost 100% at 350 °C, which is comparable with the performance of conventional Pd/Al2O3 catalysts. The reducibility of PdO under methane–oxygen mixtures is lower on Pd(z)/CaHAp. For both reactions, the lower activity of Pd(z)/CaFAp is related to its higher acidity, resulting from the substitution of OH by F, and to the larger PdO particle size.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号