首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 77 毫秒
1.
Arancibia V  López A  Zúñiga MC  Segura R 《Talanta》2006,68(5):1567-1573
The separation of arsenic based on in situ chelation with ammonium diethyl dithiophosphate (ADDTP) has been carried out using methanol-modified supercritical CO2. Aliquots of extract were added to an electroanalytical cell and arsenic was determined by square wave cathodic stripping voltammetry (SWCSV) at a hanging mercury drop electrode (HMDE). Quantitative extractions of As(DDTP)3 were achieved when the experiments were carried out at a pressure of 2500 psi, a temperature of 90 °C, 2.0 mL of methanol, 20.0 min of static extraction and 5.0 min of dynamic extraction in the presence of 18 mg of ADDTP. Analysis of arsenic was made using 150 mg L−1 of Cu(II) in 1 M HCl solution as supporting electrolyte in the presence of ADDTP as ligand. Preconcentration was carried out by deposition at a potential of −0.50 V and the intermetallic compound CuxAsy was reduced at a potential of −0.77 to −0.82 V, depending on ligand concentration. The results showed that the presence of ligand plays an important role, increasing the method's sensitivity and preventing the oxidation of As(III). The calibration graph of the As(DDTP)3 solution was linear from 0.8 to 12.5 μg L−1 of arsenic (LOD 0.5 μg L−1, R = 0.9992, tacc = 60 s). The method was validated using carrot pulp spiked with arsenic solution. This method was applied to the determination of arsenic in samples of carrots, beets and irrigation water. Arsenic in beets was: skin 4.10 ± 0.18 mg kg−1; pulp 3.83 ± 0.19 mg kg−1 and juice 0.71 ± 0.09 mg L−1; arsenic in carrots was: skin 2.15 ± 0.09 mg kg−1; pulp 0.59 ± 0.11 mg kg−1 and juice 0.71 ± 0.03 mg L−1. Arsenic in water were: Chiu-Chiu 0.08 mg L−1, Inacaliri 1.12 mg L−1, and Salado river 0.17 ± 0.07 mg L−1.  相似文献   

2.
The mass fractions of Hg and methylmercury, in two certified reference materials, NIST2710 and DORM-2, have been determined by total and species-specific isotope dilution analysis (IDA), respectively, and uncertainty budgets for each analysis calculated. The mass fraction of Hg in NIST2710 was determined by ID using multicollector sector field inductively coupled plasma mass spectrometry (MC-SF-ICP-MS) whilst the mass fraction of methylmercury in DORM-2 was determined using HPLC coupled with quadrupole ICP-MS.

The extent of equilibration between the spike and the particulate bound mercury compounds was studied temporally by monitoring the 200Hg:199Hg isotope amount ratio and by determining the total amount of Hg in the liquid phase. For the NIST2710 complete equilibration was only achieved when concentrated HNO3 in combination with a microwave digestion was employed, and good agreement between the found (31.7±4.0 μg g−1, expanded uncertainty k=2) and certified (32.6±1.8 μg g−1) values was obtained. For DORM-2 complete equilibration of methylmercury between the liquid and solid phases was achieved when using 50:50 H2O:CH3OH (v/v) and 0.01% 2-mercaptoethanol as the solvent. Even though only 50% of the analyte was extracted into the liquid phase, complete equilibration was achieved, hence, the found methylmercury mass fraction (4.25±0.47 μg g−1, expanded uncertainty k=2) was in good agreement with the certified value (4.47±0.32 μg g−1).  相似文献   


3.
An analytical method for analysing acrylamide in coffee was validated. The analysis of prepared coffee includes a comprehensive clean-up using multimode solid-phase extraction (SPE) by automatic SPE equipment and detection by liquid chromatography tandem mass spectrometry using electrospray in the positive mode. The recoveries of acrylamide in ready-to-drink coffee spiked with 5 and 10 μg l−1 were 96±14% and 100±8%, respectively. Within laboratory reproducibility for the same spiking levels were 14% and 9%, respectively. Coffee samples (n = 25) prepared twice by coffee machines and twice by a French Press Cafetière coffee maker contained 8±3 μg l−1 and 9±3 μg l−1 acrylamide. Five ready-to-drink instant coffee prepared twice contained 8±2 μg l−1. Hence, the results do not show significant differences in the acrylamide contents in ready-to-drink coffee prepared by coffee machine, French Press or from instant coffee. Medium roasted coffee contained more acrylamide (10 μg l−1) than dark roasted coffee (5 μg l−1). Males aged 35–45 years, drinking on average 1.1 l coffee per day are exposed to the highest doses of acrylamide from coffee. The dietary intake of acrylamide from coffee comprises, on an average, 10 μg day−1 for males and 9 μg day−1 for females aged 35–45 years. Probabilistic modelling of the exposure of Danish consumers (all adults) to acrylamide from coffee shows a mean exposure of 6.5 μg day−1 and a 95 percentile of 18 μg day−1.  相似文献   

4.
A simple method for the simultaneous determination of chlorophenoxy acid herbicides and their esters in soil is presented. Compounds studied are: 2,4-dichlorophenoxyacetic acid (2,4-D), 4-(2,4-dichlorophenoxy)butanoic acid (2,4-DB), 2,4-dichlorophenoxyacetic-1-butyl ester (2,4-D-1-butyl ester), and 2,4-dichlorophenoxyacetic-1-methyl ester (2,4-D-1-methyl ester).

The chromatographic analysis was carried out by HPLC, after ultrasonic extraction, on a C18 packed capillary column with temperature gradient, large injection volumes and UV detection at 232 nm. Samples were spiked with amounts between 2.5 and 6.0 μg g−1 of each herbicide; recoveries obtained were between 72 and 97% (n=3 for each spiked level) and detection limits were between 0.3 and 0.5 μg g−1.

Application of this procedure to the analysis of herbicides in ester and acid forms showed the effectiveness of the methodology proposed.  相似文献   


5.
The determination of cobalt in marine sediments by electrothermal atomic absorption spectrometry was studied using no modifier and magnesium and titanium as modifiers. Titanium is one of the major sediment constituents, which widely affects the cobalt determination and it was studied as a chemical modifier since it was the only concomitant that increased the cobalt signal in the concentration range usually found in sediments. The performance of Mg and Ti as chemical modifiers was compared relative to maximum pyrolysis and atomization temperatures, linear calibration range, sensitivity and matrix effects. The pyrolysis curves showed that the analyte could be stabilized up to 1400 °C when either Ti or Mg(NO3)2 was present, while only 1000 °C could be used in the absence of a modifier. The optimum atomization temperature was 2500 °C in all cases. Analytical curves were compared using no modifier, 5 μg Ti and 100 μg Mg(NO3)2 as modifiers, and the linear range found was up to approximately 4 ng Co whether a modifier was used or not. With Ti as a chemical modifier, analytical curves for cobalt in aqueous solution and in a synthetic matrix resulted in the same sensitivity (m0=55 pg), whereas the use of Mg led to characteristic mass values of 59 and 72 pg in aqueous solution and in a synthetic matrix, respectively, showing some matrix effect. The detection limits (3σ, n=10) were 0.4 μg g−1 using no modifier and 0.3 μg g−1 with Ti as a modifier in the original matrix. A reference estuarine sediment NIST 1646 with a non-certified content of 10.5 μg g−1 Co was analyzed and the found value of 10.9±2.4 μg g−1, (n=3), using Ti as chemical modifier and calibration against aqueous standards, was in good agreement with the recommended value.  相似文献   

6.
Analytical procedure for the determination of toxicologically relevant arsenic (the sum of arsenite, arsenate, monomethylarsonate and dimethylarsinate) in urine by flow injection hydride generation and collection of generated inorganic and methylated hydrides on an integrated platform of a transverse-heated graphite atomizer for electrothermal atomic absorption spectrometric determination (ETAAS) is elaborated. Platforms are pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which serve both as an efficient hydride sequestration medium and permanent chemical modifier. Arsine, monomethylarsine and dimethylarsine are generated from diluted urine samples (10–25-fold) in the presence of 50 mmol L−1 hydrochloric acid and 70 mmol L−1 l-cysteine. Collection, pyrolysis and atomization temperatures are 450, 500, 2100 and 2150 °C, respectively. The characteristic mass, characteristic concentration and limit of detection (3σ) are 39 pg, 0.078 μg L−1 and 0.038 μg L−1 As, respectively. The limits of detection in urine are ca. 0.4 and 1 μg L−1 with 10- and 25-fold dilutions. The sample throughput rate is 25 h−1. Applications to several urine CRMs are given.  相似文献   

7.
Arsenic was determined in gold by flow injection hydride generation inductively coupled plasma-mass spectrometry following a batch mode reductive precipitation removal of the interfering gold matrix. A solution of potassium iodide, L-ascorbic acid, and hydrochloric acid was used as the reluctant. The recovery of gold by precipitation and filtration was 99 ± 3%. The detection limit for arsenic in gold was 55 ng g−1 in the solid. The concentration of arsenic that was determined in the Royal Canadian Mint gold sample FAU-10 was 29.7 μg g−1 in the solid; this value was indistinguishable, with 95% confidence, from values determined at the Royal Canadian Mint by graphite furnace atomic absorption spectrometry and by inductively coupled plasma-mass spectrometry. The standard deviation for four replicate determinations of the arsenic in FAU-10 was 0.972 μg g−1 in the solid.  相似文献   

8.
A supported liquid membrane system has been developed for the extraction of vanillin from food samples. A porous PTFE membrane is impregnated with an organic solvent, which forms a barrier between two aqueous phases. The analyte is extracted from a donor phase into the hydrophobic membrane and then back extracted into a second aqueous solution, the acceptor. The determination (100–1400 μg ml−1 vanillin) was performed using a PVC-graphite composite electrode versus Ag/AgCl/3MKCl at +0.850 V placed in a wall-jet flow cell as amperometric detector. The solid sample is directly placed in the membrane unit without any treatment, and the analyte was extracted from the sample, passes through the membrane and conduced to the flow cell by the acceptor stream. The limit of detection (3σ) was 44 μg ml−1. The method was applied to the determination of vanillin (9–606 μg g−1) in food samples.  相似文献   

9.
Soylak M  Tuzen M  Mendil D  Turkekul I 《Talanta》2006,70(5):1129-1135
A solid phase extraction procedure based on biosorption of copper(II), lead(II), zinc(II), iron(III), nickel(II) and cobalt(II) ions on Aspergillus fumigatus immobilized Diaion HP-2MG has been investigated. The analytical conditions including amounts of A. fumigatus, eluent type, flow rates of sample and eluent solutions were examined. Good recoveries were obtained to the spiked natural waters. The influences of the concomitant ions on the retentions of the analytes were also examined. The detection limits (3sigma, N = 11) were 0.30 μg l−1 for copper, 0.32 μg l−1 for iron, 0.41 μg l−1 for zinc, 0.52 μg l−1 for lead, 0.59 μg l−1 for nickel and 0.72 μg l−1 for cobalt. The relative standard deviations of the procedure were below 7%. The validation of the presented procedure is performed by the analysis of three standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 1515 Apple leaves and GBW 07605 Tea). The procedure was successfully applied for the determination of analyte ions in natural waters microwave digested samples including street dust, tomato paste, black tea, etc.  相似文献   

10.
A procedure for the determination of As, Pb, Se and Sn in sediment slurries by electrothermal vaporization inductively coupled plasma mass spectrometry is proposed. The slurry, 1 mg ml−1, is prepared by mixing the sample ground to a particle size 50 μm with 5% v/v nitric and 1% v/v hydrofluoric acids in an ultrasonic bath. The slurry was homogenized with a constant flow of argon in the autosampler cup, just before transferring an aliquot to the graphite furnace. The tube was treated with Ru as a permanent modifier, and an optimized mass of 1 μg of NaCl was added as a physical carrier. The pyrolysis temperature was optimized through pyrolysis curves, and a compromised temperature of 800 °C was used; the vaporization temperature was 2300 °C. The effect of different acid concentrations in the slurry on the analyte signal intensities was also evaluated. The accuracy of the method was assured by the analysis of certified reference sediments MESS-2, PACS-2 and HISS-1 from the National Research Council Canada, SRM 2704 and SRM 1646a from the National Institute of Standards and Technology and RS-4 from a round robin test, using external calibration with aqueous standards prepared in the same medium as the slurries. The obtained concentrations were in agreement with the certified values according to the Student's t-test for a confidence level of 95%. The detection limits in the samples were: 0.17 μg g−1 for As; 0.3 μg g−1 for Pb; 0.05 μg g−1 for Se and 0.28 μg g−1 for Sn. The precision found for the different sediment samples, expressed as R.S.D. was 1–8% for As, 2–9% for Pb, 6–12% for Se and 3–8% for Sn (n=5).  相似文献   

11.
Using zinc hexamethylenedithiocarbamate (Zn(HMDC)2) and flame atomic absorption spectrometry (FAAS) and/or flow injection hydride generation atomic absorption spectrometry (FI-HGAAS), solvent extraction of As(III) from HCl and H2SO4 media into 2,6-dimethyl-4-heptanone (diisobutyl ketone, DIBK) was examined. Arsenic(III) was quantitatively extracted with 2.41×10−3 mol l−1 Zn(HMDC)2 from about 0.004 (pH 2.4) to 4 mol l−1 HCl and H2SO4 aqueous solutions. The logarithmic conditional extraction constant of As(HMDC)3 in the HCl–DIBK system was determined to be 8.3±0.7, by the measurement of the distribution ratios of Zn(II) and As(III). The effectiveness of the proposed extraction method was ascertained in the determination of As in geochemical standard reference materials supplied by the Geological Survey of Japan. Furthermore, the analysis of arsenic in procedural blanks was 0.083±0.003 μg l−1.  相似文献   

12.
The aim of this work was to develop and validate a simple and sensitive analytical method for determining enrofloxacin (EFX) and ciprofloxacin (CFX) in equine plasma and endometrial tissue samples, as a precursor to conducting pharmacokinetic/pharmacodynamic studies on equine endometritis This was achieved in the form of a liquid chromatographic procedure, with fluorometric detection, which also gave good separation of other fluoroquinolones including marbofloxacin (MFX), danofloxacin (DFX) and ofloxacin (OFX). Analytes were separated on a C18 reversed phase column using an acidified mobile phase. The exact composition of the mobile phase differed for plasma (16% acetonitrile:methanol [13:1,v/v] 84% water containing 0.4% triethylamine and 0.4% phosphoric acid [35%]) and endometrial tissue (14% acetonitrile, 86% water, without methanol) samples. EFX and CFX were both detected at excitation and emission wavelengths of 294 and 500 nm, respectively. Prior to chromatography, EFX and CFX were purified by solid phase extraction from plasma, and a combination of solvent/solid phase extraction from endometrial tissue.

Mean absolute recoveries for EFX and CFX from plasma were 94.1 and 78.0%, respectively, and from endometrial tissue, 78.0 and 57.8%, respectively, with a percentage residual standard deviation (%R.S.D.) <10% in each case. Mean relative recoveries for EFX and CFX from plasma were 91.3 and 119.4%, respectively, and from endometrial tissue, 80.2 and 108.0%, respectively, with a %R.S.D. <20% in each case.

Standard curves constructed using blank plasma and endometrial tissue samples, spiked with authentic EFX and CFX in the ranges 0.005–10.0 μg mL−1 and 0.05–10.0 μg g−1, respectively, all showed acceptable linearity with correlation coefficients, r2 ≥ 0.977. Mean intra- and inter-day precision (expressed as %R.S.D.) was <6 and <13%, respectively, with an associated accuracy (expressed as percentage relative error, %R.E.) of <20% for both analytes in both matrices. Acceptable precision and accuracy was also demonstrated at the pre-assigned LOQs of 0.005 μg mL−1 for both EFX and CFX in plasma, and 0.05 μg g−1 for both drugs in endometrial tissue. EFX and CFX were stable in both plasma and endometrial tissue for at least 60 days at −20 °C.  相似文献   


13.
Rapid leaching procedures by Pressurized Liquid Extraction (PLE) have been developed for As, Cd, Cr, Ni and Pb leaching from environmental matrices (marine sediment and soil samples). The Pressurized Liquid Extraction is completed after 16 min. The released elements by acetic acid Pressurized Liquid Extraction have been evaluated by inductively coupled plasma-optical emission spectrometry. The optimum multi-element leaching conditions when using 5.0 ml stainless steel extraction cells, were: acetic acid concentration 8.0 M, extraction temperature 100 °C, pressure 1500 psi, static time 5 min, flush solvent 60%, two extraction steps and 0.50 g of diatomaceous earth as dispersing agent (diatomaceous earth mass/sample mass ratio of 2). Results have showed that high acetic acid concentrations and high extraction temperatures increase the metal leaching efficiency. Limits of detection (between 0.12 and 0.5 μg g− 1) and repeatability of the over-all procedure (around 6.0%) were assessed. Finally, accuracy was studied by analyzing PACS-2 (marine sediment), GBW-07409 (soil), IRANT-12-1-07 (cambisol soil) and IRANT-12-1-08 (luvisol soil) certified reference materials (CRMs). These certified reference materials offer certified concentrations ranges between 2.9 and 26.2 μg g− 1 for As, from 0.068 to 2.85 μg g− 1 for Cd, between 26.4 and 90.7 μg g− 1 for Cr, from 9.3 to 40.0 μg g− 1 for Ni and between 16.3 and 183.0 μg g− 1 for Pb. Recoveries after analysis were between 95.7 and 105.1% for As, 96.2% for Cd, 95.2 and 100.6% for Cr, 95.7 and 103% for Ni and 94.2 and 105.5% for Pb.  相似文献   

14.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic (IC) detector for the speciation analysis of arsenic and selenium. The arsenic and selenium species studied included arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), selenite [Se(IV)] and selenate [Se(VI)]. Gradient elution using (NH4)2CO3 and methanol at pH 9 allowed the chromatographic separation of all species in less than 12 min. Effluents from the IC column were delivered to the nebulization system of ICP-DRC-MS for the determination of arsenic and selenium. The potentially interfering 38Ar40Ar+ and 40Ar40Ar+ at the selenium masses m/z 78 and 80 were reduced in intensity by approximately 3 orders of magnitude by using 0.6 mL min−1 CH4 as reactive cell gas in the DRC while an Rpq value of 0.3 was used. Meanwhile, arsenic was determined as the adduct ion 75As12CHH+ at m/z 89, which is more sensitive than 75As. The limits of detection for arsenic and selenium were in the range of 0.002–0.01 ng mL−1 and 0.01–0.02 ng mL−1, respectively, based on peak height. The relative standard deviation of the peak areas for five injections of 5 ng mL−1 As and Se mixture was in the range of 2–4%. The concentrations of arsenic and selenium species have been determined in urine samples collected locally. The major As and Se species in urines were AsB, DMA and probably selenosugar at concentration of 20–40, 15–19 and 17–31 ng mL−1, respectively. The recoveries were in the range of 94–105% for all the determinations. This method has also been applied to determine various arsenic compounds in two fish samples. In this study, a simple and rapid microwave-assisted extraction method was used for the extraction of arsenic compounds from fish. The arsenic species were quantitatively leached with an 80% v/v methanol solution in a focused microwave field during a period of 5 min.  相似文献   

15.
An atomic absorption spectrophotometric method for the determination of trace copper after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been developed. This chelate is adsorbed on the adsorbent in the pH range 1–8. The copper chelate is eluted with 5 ml of 0.1 mol l−1 potassium cyanide and determined by flame atomic absorption spectrometry (FAAS). The selectivity of the proposed procedure was also evaluated. Results show that iron(III), zinc(II), manganese(II) and cobalt(II) at the 50 μg l−1 level and sodium(I), potassium(I), magnesium(II), calcium(II) and aluminium(III) at the 1000 μg l−1 level did not interfere. A high enrichment factor, 200, was obtained. The detection limit (3σ) of copper was 0.34 μg l−1. The precision of the method, evaluated by seven replicate analyses of solutions containing 5 μg of copper was satisfactory and the relative standard deviation was 1.7%. The adsorption of copper onto Ambersorb 572 can formally be described by a Langmuir equation with a maximum adsorption capacity of 14.3 mg g−1 and a binding constant of 0.00444 l mg−1. The accuracy of the method is confirmed by analysing tomatoes leaves (NIST 1573a) and lead base alloy (NBS 53e). The results demonstrated good agreement with the certified values. This procedure was applied to the determination of copper in waters (tap, river and thermal waters), aluminium foil and tea samples.  相似文献   

16.
Bismuth as BiCl4 and BH4 ware successively retained in a column (150 mm × 4 mm, length × i.d.) packed with Amberlite IRA-410 (strong anion-exchange resin). This was followed by passage of an injected slug of hydrochloric acid resulting in bismuthine generation (BiH3). BiH3 was stripped from the eluent solution by the addition of a nitrogen flow and the bulk phases were separated in a gas–liquid separator. Finally, bismutine was atomized in a quartz tube for the subsequent detection of bismuth by atomic absorption spectrometry. Different halide complexes of bismuth (namely, BiBr4, BiI4 and BiCl4) were tested for its pre-concentration, being the chloride complexes which produced the best results. Therefore, a concentration of 0.3 mol l−1 of HCl was added to the samples and calibration solutions. A linear response was obtained between the detection limit (3σ) of 0.225 and 80 μg l−1. The R.S.D.% (n = 10) for a solution containing 50 μg l−1 of Bi was 0.85%. The tolerance of the system to interferences was evaluated by investigating the effect of the following ions: Cu2+, Co2+, Ni2+, Fe3+, Cd2+, Pb2+, Hg2+, Zn2+, and Mg2+. The most severe depression was caused by Hg2+, which at 60 mg l−1 caused a 5% depression on the signal. For the other cations, concentrations between 1000 and 10,000 mg l−1 could be tolerated. The system was applied to the determination of Bi in urine of patients under therapy with bismuth subcitrate. The recovery of spikes of 5 and 50 μg l−1 of Bi added to the samples prior to digestion with HNO3 and H2O2 was in satisfactory ranges from 95.0 to 101.0%. The concentrations of bismuth found in six selected samples using this procedure were in good agreement with those obtained by an alternative technique (ETAAS). Finally, the concentration of Bi determined in urine before and after 3 days of treatment were 1.94 ± 1.26 and 9.02 ± 5.82 μg l−1, respectively.  相似文献   

17.
Polystyrene–divinylbenzene (8%) has been functionalised by coupling it through an ---N=N--- group with 6-mercaptopurine. The resulting chelating resin has been characterised by using elemental analysis, thermogravimetric analysis and infrared spectra. The resin is highly selective for Hg(II) and Ag(I) and has been used for preconcentrating Hg(II) and Ag(I) prior to their determination by atomic absorption spectrometry. The maximum sorption capacity for Hg(II) and Ag(I) was found to be 1.74 and 0.52 mmol g−1, respectively, over the pH range 5.5–6.0. The calibration range for Hg(II) was linear up to 10 ng ml−1 with a 3σ detection limit of 0.02 ng ml−1; the calibration range for Ag(I) was linear up to 5 μg ml−1 with a detection limit of 29 ng ml−1. The recoveries of the metals were found to be 99.7±3.8 and 101.3±4.1% at the 95% confidence level for both Hg(II) and Ag(I). In column operation, it has been observed that Hg(II) and Ag(I) in trace quantities can be selectively separated from geological, medicinal and environmental samples.  相似文献   

18.
Hydrogen peroxide in basic media is proposed as a means for dissolving whole blood samples to be analyzed by electrothermal atomization atomic absorption spectrometry, ET AAS. Approximately 2 g of the whole blood sample were directly weighed in a 150 mL volumetric flask; 3 mL of a NaOH 0.2 mol L−1 solution, two drops of 1-octanol, as an antifoaming agent, and 1 mL of 30% volume hydrogen peroxide were added to the flask to promote oxidation. The solution was then manually shaken and after approximately three minutes of shaking, a clear solution, with no apparent suspended solids or greasy layers, was obtained. Distilled-deionized water was used to complete the volume. Ten μL of the resulting solution along with 10 μL of a solution containing 5000 mg L−1 of NH4H2PO4 and 300 mg L−1 of Mg(NO3)2 as a modifier, were injected into transversely heated graphite tubes for lead determination. Both aqueous standards and standard addition calibration curves produced results not significantly different at a 95% confidence limit level. Accuracy of the measurements was assessed by analysis of the IAEA A-13 (concentration of trace and minor elements in freeze dried animal blood) standard reference material containing 0.18 mg L−1 lead on a dry basis and by means of recovery tests. Analysis of the IAEA A-13 standard produced 0.17 ± 0.02 mg L−1 lead on a dry basis; recovery tests afforded values from 95 to 105%. Ten consecutive measurements of a 5 ppb lead solution gave a characteristic mass of 47.2 pg and a (3S) detection limit of 1.77 μg L−1 Pb. Results obtained from analysis of whole blood samples of volunteer donors covered a lead concentration range between 8 and 21 μg L−1 with a mean value of 11.9 ± 4.7 μg L−1.  相似文献   

19.
A simple GF-AAS method for speciation analysis of chromium in mineral waters and salinas was developed. Cr(VI) species were separated from Cr(III) by solid-phase extraction with APDC (ammonium pyrrolidinedithiocarbamate). The APDC complexes were formed in the sample solution under proper conditions, adsorbed on Diaion HP-2MG resin and the resin was separated from the sample. After elution with concentrated nitric acid Cr(VI) was determined by GF-AAS. Total chromium was determined by GF-AAS directly in the sample and Cr(III) concentration was calculated as the difference between those results.

The detection limit of the method defined as 3 s of background variation was 0.03 μg l−1 for Cr(VI) and 0.3 μg l−1 for total chromium. RSD for Cr(VI) determination at the concentration of 0.14 μg l−1 was 9%, and for total chromium at the concentration of 5.6 μg l−1 was 5%. The recovery of Cr(VI) was in the range of 94–100%, dependently on type of the sample.

The investigation of recovery of the spiked Cr(VI) showed that at concentration levels near 1 μg l−1 and lower recovery may be reduced significantly even by pure reagents that seem to be free from any reductants.  相似文献   


20.
Aceto Balsamico Tradizionale of Modena (ABTM) is a typical product (PDO denomination) of the province of Modena produced by cooked grape must which undergoes a long ageing period (at least 12 years) in series of wooden casks (batterie). The study of the transformations of this product during ageing is extremely relevant in order to control the authenticity of ABTM towards succedaneous products and mislabelling of age.

This paper presents the results of the investigation of sugars and fixed organic acids in ABTM samples of different ages, coming from different batterie. The analytes were simultaneously determined by a gas chromatographic method optimised for this peculiar matrix.

The method shows good separation and resolution of the investigated chemical species and allows their determination in the concentration ranges reported in brackets: malic (7.6–15.5 g kg−1), tartaric (4.0–9.7 g kg−1), citric (0.6–1.5 g kg−1) and succinic (0.36–0.62 g kg−1) acid and glucose (153–294 g kg−1), fructose (131–279 g kg−1), xylose (011–0.39 g kg−1), ribose (0.078–0.429 g kg−1), rhamnose (0.061–0.195 g kg−1), galactose (0.136–0.388 g kg−1), mannose (0.41–1.46 g kg−1), arabinose (0.33–1.00 g kg−1) and sucrose (0.46–6.84 g kg−1), with mean associated errors ranging from 5 to 19% depending on the analytes.

Moreover, the recovery values are always satisfactory, being close to one for most of the analytes.

Furthermore, in order to assess the degree of variability of the different analytes content with vinegar ageing and the similarity/dissimilarity among series of casks a three-way data analysis method (Tucker3) is proposed. The chemometric technique applied on the data set shows differences between the samples on the bases of their different ageing period, and between the batterie, which traditionally have an own peculiar production procedure.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号