首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Graphene was successfully prepared and well separated to individual sheets by introducing  SO3. XRD and TEM were employed to characterize the graphene. UV‐visible absorption spectra indicated that glucose oxidase (GOx) could keep bioactivity well in the graphene‐Au biocomposite. To construct a novel glucose biosensor, graphene, Au and GOx were co‐immobilized in Nafion to further modify a glassy carbon electrode (GCE). Electrochemical measurements were carried out to investigate the catalytic performance of the proposed biosensor. Cyclic voltammograms (CV) showed the biosensor had a typical catalytic oxidation response to glucose. At the applied potential +0.4 V, the biosensor responded rapidly upon the addition of glucose and reached the steady state current in 5 s, with the present of hydroquinone. The linear range is from 15 μM to 5.8 mM, with a detection limit 5 μM (based on the S/N=3). The Michaelis‐Menten constant was calculated to be 4.4 mM according to Lineweaver–Burk equation. In addition, the biosensor exhibits good reproducibility and long‐term stability. Such impressive properties could be ascribed to the synergistic effect of graphene‐Au integration and good biocompatibility of the hybrid material.  相似文献   

2.
Multi‐walled carbon nanotubes (MWNTs) were dispersed in the ionic liquid [BMIM][BF4] to form a uniform black suspension. Based on it, a novel glucose oxidase (GOx)‐hyaluronic (HA)‐[BMIM][BF4]‐MWNTs/GCE modified electrode was fabricated. UV‐vis spectroscopy confirmed that GOx immobilized in the composite film retained its native structure. The experimental results of EIS indicated MWNTs, [BMIM][BF4] and HA were successfully immobilized on the surface of GCE and [BMIM][BF4]‐MWNTs could obviously improve the diffusion of ferricyanide toward the electrode surface. The experimental results of CV showed that a pair of well‐defined and quasi‐reversible peaks of GOx at the modified electrode was exhibited, and the redox reaction of GOx at the modified electrode was surface‐confined and quasi‐reversible electrochemical process. The average surface coverage of GOx and the apparent Michaelis‐Menten constant were 8.5×10−9 mol/cm2 and 9.8 mmol/L, respectively. The cathodic peak current of GOx and the glucose concentration showed linear relationship in the range from 0.1 to 2.0 mmol/L with a detection limit of 0.03 mmol/L (S/N=3). As a result, the method presented here could be easily extended to immobilize and obtain the direct electrochemistry of other redox enzymes or proteins.  相似文献   

3.
The sol-gel derived glucose biosensor was developed, and the sol-gel membrane was organically modified by N-(3-triethoxysilylpropyl)-ferrocenylmethylamine (FcSi) as sol-gel precursor to make electrochemical biosensor. The structure of biosensor was sol-gel/FcSi+GOx/GC type (glucose oxidase, GOx). The ferrocene mediator was chemically immobilized to the silane network, and GOx was entrapped to the sol-gel glass network. Therefore, these structures prevented mediator leakage and retained the enzyme activity. Additionally, pH of electrolyte, temperature effects, and interference of positive substances with biosensor were investigated. And the electrochemical performance of biosensor was studied by amperometry. The results indicated that the linear range, detection limit. and response slope of biosensor was 2.00×10^-4-1.57×10^-3 mol·L^-1, 2.0×10^-4 mol·L^-1 and 5.06×10^5 nA·mol^- 1·L, respectively.  相似文献   

4.
This study demonstrates a miniaturized integrated glucose biosensor based on a carbon microbeads entrapped by glucose oxidase (GOx) immobilized on poly (N-isopropylacrylamide) (pNIPAm) microgels. Determined by the Lowry protein assay, the pNIPAm microgel possesses a high enzyme loading capacity of 31?mg/g. The pNIPAm GOx loaded on the microgel was found to maintain a high activity of approximately 0.140?U determined using the 4-aminoantipyrine colorimetric method. The integrated microelectrochemical cell was constructed using a microcentrifuge vial housing packed with (1:1, w/w) carbon entrapped by pNIPAm GOx microgels, which played the dual role of the microbioreactor and the working electrode. The microcentrifuge vial cover was used as a miniaturized reference electrode and an auxiliary electrode holder. The device can work as biosensor, effectively converting glucose to H2O2, with subsequent amperometric detection at an applied potential of ?0.4?V. The microelectrochemical biosensor was used to detect glucose in wide linear range from 30?µM to 8.0?mM, a low detection limit of 10?µM, a good linear regression coefficient (R2) of 0.994, and a calibration sensitivity of 0.0388?µA/mM. The surface coverage of active GOx, electron transfer rate constant (ks), and Michaelis–Menten constant (KMapp) of the immobilized GOx were 4.0?×?10?11?mol/cm2, 5.4?s?1, and 0.086?mM, respectively. To demonstrate the applicability and robustness of the biosensor for analysis of high sample matrix environment, glucose was analyzed in root beer. The microelectrochemical device was demonstrated for analysis of small sample (<50?µL), while affording high precision and fast signal measurement (≤5?s).  相似文献   

5.
《Electroanalysis》2018,30(8):1642-1652
A newly developed amperometric glucose biosensor based on graphite rod (GR) working electrode modified with biocomposite consisting of poly (pyrrole‐2‐carboxylic acid) (PCPy) particles and enzyme glucose oxidase (GOx) was investigated. The PCPy particles were synthesized by chemical oxidative polymerization technique using H2O2 as initiator of polymerization reaction and modified covalently with the GOx (PCPy‐GOx) after activation of carboxyl groups located on the particles surface with a mixture of N‐(3‐dimethylaminopropyl)‐N′‐ethylcarbodiimide hydrochloride (EDC) and N‐hydroxysuccinimide (NHS). Then the PCPy‐GOx biocomposite was dispersed in a buffer solution containing a certain amount of bovine serum albumin (BSA). The resulting biocomposite suspension was adsorbed the on GR electrode surface with subsequent solvent airing and chemical cross‐linking of the proteins with glutaraldehyde vapour (GR/PCPy‐GOx). It was determined that the current response of the GR/PCPy‐GOx electrodes to glucose measured at +300 mV vs Cl reference electrode was influenced by the duration of the PCPy particles synthesis, pH of the GOx solution used for the PCPy particles modification and the amount of immobilized PCPy‐GOx biocomposite. An optimal pH of buffer solution for operation of the biosensor was found to be 8.0. Detection limit was determined as 0.039 mmol L−1 according signal to noise ratio (S/N: 3). The proposed glucose biosensor was tested in human serum samples.  相似文献   

6.
Nail‐like carbon (NLC) was synthesized by a simple hydrothermal method. It was the first time that a novel electrochemical biosensing of glucose was explored based on the glucose oxidase (GOx)‐NLC‐chitosan (CHIT) glassy carbon electrode. Morphology and structure of NLC were characterized by scanning electron microscope; meanwhile the chemical composition was determined by X‐ray diffraction and energy dispersive X‐ray spectroscopy. The cyclic voltammetry of immobilized GOx showed a pair of quasireversible redox peaks with the formal potential (E°′) of ?0.458 V and the peak‐to‐peak potential separation was 47 mV at a scan rate of 100 mV s?1. The present biosensor has a linear range of glucose from 0.02 to 1.84 mM (correlation coefficient of 0.9991) and detection limit of 0.01 mM (S/N=3). Compared with the previous reports based on the carbon material biosensor, it has a high sensitivity of 165.5 μA mM?1 cm?2 and low apparent Michaelis–Menten constant of 0.506 mM. Thus, the NLC may have potential applications in the field of bioelectrochemistry, bioelectronics and biofuels.  相似文献   

7.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

8.
利用纳米金(Au NPs)与还原氧化石墨烯(rGO)复合纳米材料制备了葡萄糖氧化酶生物传感器并用于饮料中葡萄糖含量的检测。将壳聚糖作为还原剂及稳定剂,通过一步法合成了Au NPs-rGO复合材料,并通过物理吸附固定葡萄糖氧化酶(GOx)来制作GOx生物传感器。该传感器在磷酸盐缓冲溶液(0.1 mol/L,p H6.0)中,-0.45 V(vs.Ag/Ag Cl)电位下电流法检测葡萄糖含量,线性检测范围为0.01~0.88 mmol/L,灵敏度为22.54μA·mmol-1·L·cm-2,检出限为1.01μmol/L,且表观米氏常数为0.497 mmol/L。该传感器用于多种饮料中葡萄糖含量的直接检测,结果满意。  相似文献   

9.
In this study, a new glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on platinum nanoparticles (Pt NPs) decorated reduced graphene oxide (rGO)/Zn‐MOF‐74 hybrid nanomaterial. Herein, the biosensor fused the advantages of rGO with those of porous Zn‐MOF and conductive Pt NPs. This has not only enlarged the surface area and porosity for the efficient GOx immobilization and faster mass transport, but also provided favorable electrochemical features such as high current density, remarkable electron mobility through metal nanoparticles, and improved electron transfer between the components. The GOx‐rGO/Pt NPs@Zn‐MOF‐74 coated electrode displayed a linear measurement range for glucose from 0.006 to 6 mM, with a detection limit of 1.8 μM (S/N: 3) and sensitivity of 64.51 μA mM?1 cm?2. The amperometric response of the enzyme biosensor demonstrated the typical behavior of Michaelis‐Menten kinetics. The obtained satisfying sensitivity and measurement range enabled fast and accurate glucose measurement in cherry juice using the fabricated biosensor. The water‐stable Zn‐MOF‐74 demonstrated higher enzyme loading capacity and can be potent supporting material for biosensor construction.  相似文献   

10.
A highly efficient enzyme immobilization method has been developed for electrochemical biosensors using polydopamine films with gold nanoparticles (AuNPs) embedded. This simple enzyme fabrication method can be performed in very mild conditions and stored in a long time with high bioactivity. The fabricated amperometric glucose biosensor exhibited a high and reproducible sensitivity, wide linear dynamic range and low limit of detection (LOD) (0.1 μmol·L?1). A low value of 1.5 mmol·L?1 for the apparent Michaelis‐Menten constant KappM was obtained. The high sensitivity, wide linear range, good reproducibility and stability make this biosensor a promising candidate for portable amperometric glucose biosensor.  相似文献   

11.
In this research a novel osmium complex was used as electrocatalyst for electroreduction of oxygen and H2O2 in physiological pH solutions. Electroless deposition at a short period of time (60 s), was used for strong and irreversible adsorption of 1,4,8,12‐tetraazacyclotetradecane osmium(III) chloride (Os(III)LCl2) ClO4 onto single‐walled carbon nanotubes (SWCNTs) modified GC electrode. The modified electrode shows a pair of well defined and reversible redox couple, Os(IV)/Os(III) at wide pH range (1–8). The glucose biosensor was fabricated by covering a thin film of glucose oxidase onto CNTs/Os‐complex modified electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The fabricated biosensor shows high sensitivity, 826.3 nA μM?1cm?2, low detection limit, 56 nM, fast response time <3 s and wide calibration range 1.0 μM–1.0 mM. The biosensor has been successfully applied to determination of glucose in human plasma. Because of relative low applied potential, the interference from electroactive existing species was minimized, which improved the selectivity of the biosensor. The apparent Michaelis‐Menten constant of GOx on the nanocomposite, 0.91 mM, exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this glucose biosensor.  相似文献   

12.
《Electroanalysis》2017,29(11):2507-2515
In the present study, a novel enzymatic glucose biosensor using glucose oxidase (GOx) immobilized into (3‐aminopropyl) triethoxysilane (APTES) functionalized reduced graphene oxide (rGO‐APTES) and hydrogen peroxide sensor based on rGO‐APTES modified glassy carbon (GC) electrode were fabricated. Nafion (Nf) was used as a protective membrane. For the characterization of the composites, Fourier transform infrared spectroscopy (FTIR), X‐ray powder diffractometer (XRD), and transmission electron microscopy (TEM) were used. The electrochemical properties of the modified electrodes were investigated using electrochemical impedance spectroscopy, cyclic voltammetry, and amperometry. The resulting Nf/rGO‐APTES/GOx/GC and Nf/rGO‐APTES/GC composites showed good electrocatalytical activity toward glucose and H2O2, respectively. The Nf/rGO‐APTES/GC electrode exhibited a linear range of H2O2 concentration from 0.05 to 15.25 mM with a detection limit (LOD) of 0.017 mM and sensitivity of 124.87 μA mM−1 cm−2. The Nf/rGO‐APTES/GOx/GC electrode showed a linear range of glucose from 0.02 to 4.340 mM with a LOD of 9 μM and sensitivity of 75.26 μA mM−1 cm−2. Also, the sensor and biosensor had notable selectivity, repeatability, reproducibility, and storage stability.  相似文献   

13.
In this study, we report the fabrication of the indium tin oxide (ITO) glass electrode modified with iron oxide nanoparticles (IONPs) and nafion for glucose biosensor applications. The IONPs was synthesized using the precipitation method and functionalized with citric acid (CA) to provide hydrophilic surface and functional group for glucose oxidase (GOx) enzyme immobilization. The structural and morphological studies of CA-IONPs were characterized using X-ray diffractometer (XRD) and transmission electron microscope (TEM). The size of the IONPs measured from TEM image was ∼17 nm. The bioelectrode designated as Nafion/GOx/CA-IONPs/ITO was developed by drop casting of the CA-IONPs, GOx and nafion on the ITO glass. The Nafion/GOx/CA-IONPs/ITO bioelectrode showed good electrochemical performance for glucose detection. The functionalized CA-IONPs acted as the catalyst and help to improve the electron transfer rate between GOx and ITO electrode. In addition, thin nafion film was coated on the electrode to prevent interference and improve chemical stability. The Nafion/GOx/CA-IONPs/ITO bioelectrode showed high sensitivity of 70.1 μAmM-1cm-2 for the linear range of 1.0-8.0 mM glucose concentrations.  相似文献   

14.
A new approach to constructing an enzyme-containing film on the surface of a gold electrode for use as a biosensor is described. A basic multilayer film (BMF) of (PDDA/GNPs) n /PDDA was first constructed on the gold electrode by electrostatic layer-by-layer self-assembly of poly(diallyldimethylammonium chloride) (PDDA) and gold nanoparticles (GNPs). Glucose oxidase (GOx) was then sorbed into this BMF by dipping the BMF-modified electrode into a GOx solution. The assembly of the BMF was monitored and tested via UV-vis spectroscopy and cyclic voltammetry (CV). The ferrocenemethanol-mediated cyclic voltammograms obtained from the gold electrode modified with the (PDDA/GNPs) n /PDDA/GOx indicated that the assembled GOx remained electrocatalytically active for the oxidation of glucose. Analysis of the voltammetric signals showed that the surface coverage of active enzyme was a linear function of the number of PDDA/GNPs bilayers. This result confirmed the penetration of GOx into the BMF and suggests that the BMF-based enzyme film forms in a uniform manner. Electrochemical impedance measurements revealed that the biosensor had a lower electron transfer resistance (R et) than that of a sensor prepared by layer-by-layer assembly of PDDA and GOx, due to the presence of gold nanoparticles. The sensitivity of the biosensor for the determination of glucose, which could be controlled by adjusting the number of PDDA/GNPs bilayers, was investigated.  相似文献   

15.
《Electroanalysis》2004,16(20):1711-1716
A glucose microbiosensor has been developed using electrochemical codeposition of glucose oxidase (GOx) along with MnO2 as mediator, onto a single carbon fiber microelectrode. A two‐step deposition of only MnO2 initially and then of MnO2 in the presence of GOx has been introduced to ensure appropriate activity of the mediator. Several parameters such as deposition potential and time, concentration levels etc. have been characterized and optimized. A thin Nafion film was applied as an immobilization/encapsulation and interference‐free protective layer. The proposed microbiosensor was employed as an amperometric glucose detector at pH 7.5 at an operating potential of +0.58 V (vs. Ag/AgCl). The microbiosensor is characterized by a well‐reproducible amperometric response, linear signal‐to‐glucose concentration range from 1.5 mmol L?1 to 15 mmol L?1, and a limit of detection (S/N=3) of 0.8 mmol L?1. The microbiosensor exhibits good stability over more than ten hours of continuous measurement.  相似文献   

16.
《Analytical letters》2012,45(5):897-906
Abstract

A wireless magnetoelastic glucose biosensor in blood plasma is described, based on using a mass sensitive magnetoelastic sensor as transducer. The glucose biosensor was fabricated by coating the ribbon‐like, magnetoelastic sensor with a pH sensitive polymer and a biolayer of glucose oxidase (GOx) and catalase. The pH response polymer swells or shrinks, thereby changing sensor mass loading, respectively, in response to increase or decrease of pH values. The GOx–catalyzed oxidation of the glucose in blood plasma produces gluconic acid, resulting in the pH sensitive polymer shrinking, which in turn decreases the sensor mass loading. The results show that the proposed magnetoelastic glucose biosensor can be successfully applied to determine the concentration of glucose in blood plasma. At glucose concentration range of 2.5–20.0 mmol/l, the biosensor responses are reversible and linear, with a detection limit of 1.2 mmol/l. Since no physical connections between the sensor and the monitoring instruments are required, this proposed biosensor can potentially be applied to in vivo and in situ measurement of glucose concentration in physiological fluids.  相似文献   

17.
《Electroanalysis》2006,18(15):1485-1491
A novel cheap and simple amperometric biosensor, based on the immobilization of glucose oxidase (GOD) into anionic clay; layered double hydroxides (LDHs) [Zn3‐Al‐Cl] is presented. GOD can be entrapped in the LDHs gel via electrostatic interaction. Amperometric detection of glucose with an unmediated sensor at 0.6 V (vs. SCE) results in a rapid response (5 s), a wide linear range of 0.001–12 mM, as well as good operational stability. The low detection limit was 0.1 μM at 3σ. The apparent Michaelis‐Menten constant (K is 4.4 mM. The general interferences that coexisted in blood serum do not affect glucose determination, except for uric acid. In addition, optimization of the biosensor construction and the effects of the applied potential on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

18.
An effective, stable enzymatic glucose biosensor was fabricated on a glassy carbon electrode (GCE) surface using simple multicomposite materials (MCM): a solution of prepared poly(diallyldimethylammonium chloride)‐capped gold nanoparticles‐nickel ferrite particles‐carbon nanotubes‐chitosan (PDDA‐AuNPs‐NiFe2O4‐CNTs‐CHIT), electropolymerization of poly(o‐phenylenediamine) (PoPD) and immobilization of glucose oxidase (GOx). Biocompatibility and synergy of the MCM enhanced the immobilization and the reaction of GOx and as well as the electron transfer from an oxidation reaction of hydrogen peroxide in the system. The NiFe2O4 was synthesized by co‐precipitation and calcined at 700 °C. Characterization was carried out by field emission scanning electron microscopy (FE‐SEM), energy‐dispersive X‐ray spectroscopy (EDX), Fourier transform infrared spectroscopy (FTIR) and X‐ray diffraction (XRD) which presented both tetrahedral and octahedral metal stretching with a cubic NiFe2O4 crystal phase. The GOx/PoPD/MCM/GCE yielded a 0.77 s?1 charge transfer rate constant (Ks), a 2.28×10?6 cm2 s?1 diffusion coefficient value (D), a 0.21 mm2 electroactive surface area (Ae) and a 1.93×10?8 mol cm?2 surface concentration ( ) as determined by cyclic voltammetry. The modified electrode showed a durable operation time (n=97, more than 50 % I), repeatability (%RSD=0.38, n=10), reproducibility (%RSD=1.60, n=10), high sensitivity (853.07 μA mM?1 cm?2), selectivity without effects of electroactive species (aspirin, uric acid, caffeine, cholesterol, ascorbic acid and dopamine) and two linear ranges from 0.5 to 10 μM (R2=0.998) and 10 to 15,000 μM (R2=0.991) with a low detection limit (0.35 μM, S/N=3). Its Michaelis‐Menten constant (Km) was calculated as 93.51 μM with 46.30 μA maximum current (Imax). This proposed simple method was successfully applied for glucose determination in human blood samples.  相似文献   

19.
《Electroanalysis》2006,18(18):1842-1846
Nanosized Prussian blue (PB) particles were synthesized with a chemical reduction method and then the PB nanoparticles were assembled on the surface of multiwall carbon nanotubes modified glassy carbon electrode (PB/MWNTs/GCE). The results showed that the PB/MWNTs nanocomposite exhibits a remarkably improved catalytic activity towards the reduction of hydrogen peroxide. Glucose oxidase (GOD) was immobilized on the PB/MWNTs platform by an electrochemically polymerized o‐phenylenediamine (OPD) film to construct an amperometric glucose biosensor. The biosensor exhibited a wide linear response up to 8 mM with a low detection limit of 12.7 μM (S/N=3). The Michaelis–Menten constant Km and the maximum current imax of the biosensor were 18.0 mM and 4.68 μA, respectively. The selectivity and stability of the biosensor were also investigated.  相似文献   

20.
XU  Jiming  HAN  Wenxia  YIN  Qifan  SONG  Jie  ZHONG  Hui 《中国化学》2009,27(11):2197-2202
The direct electrochemistry of glucose oxidase (GOD) was achieved based on the immobilization of GOD on a natural nano‐structural attapulgite (ATP) clay film modified glassy carbon (GC) electrode. The immobilized GOD displayed a pair of well‐defined quasi‐reversible redox peaks with a formal potential (E0′) of ?457.5 mV (vs. SCE) in 0.1 mol·L?1 pH 7.0 phosphate buffer solution. The peak current was linearly dependent on the scan rate, indicating that the direct electrochemistry of GOD in that case was a surface‐controlled process. The immobilized glucose oxidase could retain bioactivity and catalyze the oxidation of glucose in the presence of ferrocene monocarboxylic acid (FMCA) as a mediator with the apparent Michaelis‐Menten constant Kappm of 1.16 mmol·L?1. The electrocatalytic response showed a linear dependence on the glucose concentration ranging widely from 5.0×10?6 to 6.0×10?4 mol·L?1 (with correlation coefficient of 0.9960). This work demonstrated that the nano‐structural attapulgite clay was a good candidate material for the direct electrochemistry of the redox‐active enzyme and the construction of the related enzyme biosensors. The proposed biosensors were applied to determine the glucose in blood and urine samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏