首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhou L  Li J  Wang X  Qiao J  Zhang Z 《色谱》2012,30(5):452-456
运用高效液相色谱-电喷雾质谱(HPLC-ESI-MS)技术,建立了快速、简单、灵敏的比格犬静脉滴注艾普拉唑钠盐后血药浓度的检测方法。血浆样品采用蛋白沉淀法,以丁螺环酮作为内标,色谱柱为Teknokroma Kromasil C18(100 mm×2.1 mm, 5 μm),流动相为水-甲醇-乙腈(69:8:23, v/v/v)(含0.1%的甲酸),流速0.2 mL/min,采用电喷雾(ESI)离子源以正离子方式检测。绘制血药浓度-时间曲线,并采用DAS 2.0计算药代动力学参数。方法学实验结果表明内源性杂质不干扰艾普拉唑和内标的测定,线性范围为5~10000 μg/L (r=0.994),最低定量限为5 μg/L,精密度和准确度均符合生物样品测定的要求。低、中、高3个浓度的绝对回收率在106%左右,基质效应小于142.0%,表明该方法适合比格犬血浆中艾普拉唑浓度的测定及药代动力学研究。比格犬静脉滴注艾普拉唑钠盐3个剂量(0.2 mg/kg、0.8 mg/kg和3.2 mg/kg)后的药-时曲线下面积(AUC(0~∞))分别为(2.4×104±3×103)、(8.8×104±1.6×104)和(5.4×105±8×104) μg/L•min,呈线性药物代谢动力学过程。  相似文献   

2.
高效液相色谱法测定大鼠血浆中的原儿茶酸   总被引:3,自引:0,他引:3  
《色谱》2007,25(2):207-210
建立了大鼠血浆中原儿茶酸含量测定的高效液相色谱方法。采用的色谱柱为DiamondsilTM C18 柱(150 mm×4.6 mm,5 μm);流动相为乙腈-水(体积比为9∶91,用H3PO4 调pH至2.5);流速1.2 mL/min;检测波长260 nm;内标为对羟基苯甲酸。原儿茶酸的线性范围为0.050~3.20 mg/L,线性相关系数为0.9978,最低定量限为0.050 mg/L,日内和日间测定的精密度(以相对标准偏差表示)均低于7.0%,准确度(以相对误差表示)为-1.4%~2.6%;在0.050,0.40,3.20 mg/L低、中、高3个添加浓度水平下,血浆样品的提取回收率分别为83.4%,87.3%,91.1%。该方法简便,灵敏,准确,适用于大鼠体内原儿茶酸的药物动力学研究。  相似文献   

3.
A highly sensitive and specific atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry method was developed for serum pharmacokinetic studies of puerarin in rats. Chromatography was carried out on a reversed-phase Phenomenex Synergi 4 microm Fusion-RP80 column (150 x 2.0 mm i.d.) using a mobile phase consisting of acetonitrile-water (10:90, v/v) in 10 mm NH(4)OAc with a flow rate of 0.2 mL/min. Puerarin was analyzed in the multiple reaction monitoring mode with a precursor/product ion transition of m/z 415/267. The method was demonstrated to be specific and sensitive, and a linear response was observed over a range of 2-5000 ng/mL in rat serum. The validated method was successfully applied to the characterization of the pharmacokinetics of puerarin in rat serum after oral administration to spontaneously hypertensive rats. The blood concentration-time profile of puerarin showed a rapid initial increase, reaching a maximum and then declining within 1 h. Puerarin could not be detected after 24 h. The main pharmacokinetic parameters for puerarin after oral administration were as follows: C(max) (3.54 +/- 2.03 mg/L), T(max) (0.68 +/- 0.37 h), AUC(0-t) (7.29 +/- 3.79 mg h/L), AUC(0-infinity) (9.17 +/- 4.87 mg h/L), T(1/2) (1.7 +/- 0.6 h), CL/F (7.24 +/- 4.27 L/h/kg) and V/F (17.88 +/- 13.55 L/h/kg).  相似文献   

4.
A simple RP-HPLC method was established for the determination of salidroside in dog plasma. Salidroside is one of the most active ingredients of Rhodiola L. The method had within-run precision values in the range of +/- 2.3 to +/- 9.1% (n = 5) and between-run precision in the range of +/- 3.2 to +/- 9.8%. A simple protein precipitation for salidroside extraction was processed using ACN at precipitant-to-plasma volume ratio (P-P ratio) of 3:2. The extraction recoveries of salidroside at seven concentrations were higher than 63.2%. There was a linear relationship between chromatographic area and concentration over the range of 0.83-520 microg/mL for salidroside in plasma (R = 0.9926). The LOQ (S/N = 10) of the method was 0.83 microg/mL. The method was applied in a study of the pharmacokinetics of salidroside injection in six beagle dogs. The major pharmacokinetic parameters of C(max), AUC(0-24), AUC(0-infinity), and t(1/2) of salidroside in beagle dogs after i.v. administration of a single 75 mg/kg (5 mL/kg) dose were 96.16 +/- 8.59 microg/mL, 180.3 +/- 30.6 microg h/mL, 189.3 +/- 32.1 microg h/mL, and 2.006 +/- 0.615 h, respectively.  相似文献   

5.
A high-performance liquid chromatographic (HPLC) method was developed for the first time to simultaneously quantify syringin and chlorogenic acid in rat plasma using wavelength-transfer technology. The analysis was performed on a Diamonsil C(18) column (200 x 4.6 mm i.d., 5 microm particle size) with isocratic mobile phase consisting of acetonitrile-0.05% phosphoric acid (12:88, v/v). The linear ranges were 0.20-10 and 0.25-30 microg/mL, respectively. The lower limits of quantification were 0.20 and 0.25 microg/mL, respectively. The method was shown to be reproducible and reliable with intraday precision below 8.5 and 6.1%, interday precision below 7.1 and 5.5%, accuracy within +/-7.1 and +/-8.6%, and mean extraction recovery excess of 92.1 and 80.9%, respectively, which were all calculated from the blank plasma sample spiked with syringin and chlorogenic acid at three concentrations of 0.20, 1.0 and 6.0 microg/mL for syringin and 0.25, 2.0 and 20 microg/mL for chlorogenic acid. This method was validated for specificity, accuracy and precision and was successfully applied to the pharmacokinetic study of syringin and chlorogenic acid in rat plasma after intravenous administration of Aidi lyophilizer.  相似文献   

6.
A sensitive and simple high-performance liquid chromatographic method with UV detection was developed and validated for the determination of andrographolide in rat whole blood. Carbamazepine was employed as internal standard and the blood sample was extracted with chloroform. Chromatographic separations were achieved on a Chromasil ODS column (250 x 4.6 mm, 5 microm). The mobile phase was consisted of methanol-water (52:48, v/v) and delivered at 0.8 mL/min. The detection wavelength was set at 225 nm. The calibration curve had a good linearity in the range 0.053-530 microg/mL in rat whole blood with its correlation coefficient being 0.996. The extraction recovery of andrographolide was ranged from 65.7 to 72.6%. The intra-day and inter-days repeatabilities were below 4.2% in terms of the percentage of relative standard deviation (RSD). The method was used to provide data on the pharmacokinetics of the drug in rats. The data obtained was processed using the 3P87 pharmacokinetic program. The results showed that the disposition of andrographolide after intravenous administration of liposomal andrographolide conformed to a two-compartment open model with alpha = 4.75 x 10(-2) +/- 2.41 x 10(-3) min(-1), beta = 3.16 x 10(-3) +/- 1.58 x 10(-4) min(-1), V(c) = 174.67 +/- 13.97 mL, k(21) = 1.60 x 10(-2) +/- 8.12 x 10(-4) min(-1), k(10) = 9.38 x 10(-3) +/- 5.62 x 10(-4) min(-1), k(12) = 2.53 x 10(-2) +/- 1.27 x 10(-3) min(-1) and AUC(0-infinity) = 1525.47 +/- 92.35 microg min/mL. For the intragastric administration of andrographolide tablets, the disposition of andrographolide followed a one-compartment open model with k(e) = 6.78 x 10(-3) +/- 3.53 x 10(-4) min(-1), k(a) = 3.69 x 10(-2) +/- 4.68 x 10(-3) min(-1), T(max) = 59.69 +/- 3.61 min, C(max) = 1.62 +/- 0.11 microg/mL, V(c) = 1056.90 +/- 83.42 mL, AUC(0-infinity) = 348.75 +/- 24.41 microg min/mL.  相似文献   

7.
A rapid and simple reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for determination of myrislignan in rat plasma after intravenous administration. The analytes extracted from plasma samples by solid-phase extraction were successfully carried out on a Diamonsiltrade mark ODS C(18) column (250 x 4.6 mm i.d., 5 microm) with an RP(18) guard column (8 x 4.6 mm i.d., 5 microm) and a mobile phase of MeOH-H(2)O (4:1, v/v). The UV detector was set at a single wavelength of 270 nm. The linear ranges of the standard curves were 0.5-30.0 microg/mL with the correlation coefficients greater than 0.9992. The lower limits of detection and quantification were 0.1 and 0.3 microg/mL for myrislignan. Intra- and inter-day precisions were 2.4-7.5 and 1.3-5.7%, respectively. The extraction recovery from plasma was more than 90%. This assay method has been successfully used to study the pharmacokinetics of myrislignan in rats.  相似文献   

8.
A simple, sensitive and selective high-performance liquid chromatographic (HPLC) method with UV detection (306 nm) was developed and validated for determination of tenatoprazole, a novel proton-pump inhibitor, in dog plasma. Tenatoprazole and internal standard (pantoprazole) were extracted into diethyl ether and separated using an isocratic mobile phase of 10 mm phosphate buffer (pH4.7)-acetonitrile (70:30, v/v) on a Diamonsil C(18) column (150 x 4.6 mm, 5 microm). The retention times for tenatoprazole and internal standard were 7.1 and 12.3 min, respectively. No endogenous interferences were observed. This HPLC method was fully validated. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 20%. A linear range of 0.02-5.0 microg/mL was established. The interday and intraday precisions were within RSD 13.4-10.1 and 4.6-1.4%, respectively. This method developed can be easily applied to the pharmacokinetic study of tenatoprazole in dog plasma after oral administration of an enteric-coated capsule. The plasma concentration of tenatoprazole from six dogs showed a mean C(max) of 2.63 microg/mL at T(max) of 1.89 h. The bioavailability of tenatoprazole was improved by administration of enteric-coated capsule.  相似文献   

9.
固相萃取-高效液相色谱法测定人血浆中的川芎嗪   总被引:7,自引:0,他引:7  
建立了高效液相色谱测定人血浆中川芎嗪浓度的方法。色谱条件:分析柱为Luna C18(150 mm×4.6 mm i.d.,5 μ m),流动相为甲醇-乙腈-醋酸盐缓冲液(pH 5.0)(体积比为50∶8∶42),流速1.0 mL/min,柱温40 ℃,检测波长280 nm。 血浆样品预处理采用C8固相小柱萃取法。方法的线性范围为25~5000 μg/L,线性相关系数为0.9999。高、中、低浓度 的川芎嗪在标准血浆样品中的平均提取回收率为96.72%~100.90%,日内和日间相对标准偏差(RSD)小于8.64%,准确度 为99.59%~103.26%,检测限为10 μg/L。该方法的各项效能指标符合生物样品的分析要求,可用于川芎嗪制剂的人体药 代动力学研究。  相似文献   

10.
A sensitive and simple HPLC method has been developed and validated for the determination of oxyresveratrol (trans-2,4,3',5'-tetrahydroxystilbene, OXY) and resveratrol (trans-3,5,4'-trihydroxystilbene, RES) in rat plasma. The plasma samples were extracted with ethyl acetate and analyzed using HPLC on an Aglient Zorbax SB-C(18) column (250 x 4.6 mm, 5 microm) at a wavelength 320 nm, with a linear gradient of (A) acetonitrile and (B) 0.5% aqueous acetic acid (v/v), at a flow rate of 1.0 mL/min. The method was linear over the range of 0.1265-25.3 microg/mL for OXY and 0.117-23.4 microg/mL for RES. The extraction recovery for OXY, RES and internal standard ranged from 71.1 to 88.3%. The intra- and inter-day precisions were better than 10%, and the accuracy ranged from 89 to 108%. The validated method was used to study the pharmacokinetic profiles of OXY and RES in rat plasma after oral administration of Smilax china root extract.  相似文献   

11.
The potential of online trace enrichment on a highly apolar short column in LC was evaluated for the determination of pyrethroids in river water. Twelve millilitres of water samples, modified with 8 mL ACN (ACN/water 40:60, v/v), were passed through 50 x 4.6 mm ID first separation column packed with 5 microm Hypersil Elite C18. Pesticides were preconcentrated in this column while the matrix background was eluted to waste. Separation of pesticides was performed on a 3.5 microm symmetric C18 column (250 x 4.6 mm ID) with an ACN step gradient as mobile phase and fluorescence detection was used after postcolumn derivatization by using UV light. The use of photochemically induced fluorescence for detection improved sensitivity and selectivity. Quantification limits ranged from 0.05 to 0.1 microg/L and pesticide recoveries at two concentration levels (0.1 and 0.5 microg/L) were between 93.1 and 118.6%, with RSD between 2.5 and 7.5% (n = 3) in river water samples. No matrix effect was detected.  相似文献   

12.
高效液相色谱法测定水产品中残留的吡喹酮   总被引:2,自引:0,他引:2  
沈晓盛  于慧娟  蔡友琼  黄冬梅 《色谱》2007,25(6):861-863
建立了一种灵敏度高、操作简单的定量分析水产品中残留的微量吡喹酮的高效液相色谱方法。样品经乙酸乙酯提取、极性硅胶柱净化后进行高效液相色谱分析,以乙腈-水(体积比为50∶50)为流动相,流速为0.9 mL/min,ZORBAX C18色谱柱分离,紫外检测波长为214 nm。在此条件下吡喹酮在0.02~20 mg/L范围内呈线性关系,相关系数为0.99998;吡喹酮的加标回收率在85%以上,检出限为10 μg/kg。  相似文献   

13.
A simple, rapid and accurate HPLC method has been developed for simultaneous determination of hydroxysafflor yellow A and ferulic acid in rat plasma after oral administration of the co-extractum of Rhizoma chuanxiong and Flos Carthami. Plasma samples were deproteinized with 6% perchloric acid, and riboflavin was used as internal standard. The supernatant after centrifuge was injected into a Shimadzu C(18) (150 x 4.6 mm, i.d. 5 microm) column. Gradient elution for A:B (0 min, 90:10; 25 min, 70:30; 27 min, stop) was applied. The mobile phase was composed of 0.022 mol/L potassium dihydrogen phosphate solutions, adjusted to pH 3.0 with phosphoric acid for pump A, and 90% (v/v) acetonitrile for pump B. The assay was shown to be linear over the range 0.046-4.6 microg/mL (r(2) = 0.9995) for hydroxysafflor yellow A and 0.037-3.7 microg/mL (r(2) = 0.9998) for ferulic acid. Mean recovery was 97.5% for hydroxysafflor yellow A and 83.6% for ferulic acid. Both of the intra-day and inter-day precisions were 相似文献   

14.
This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using water-acetonitrile (40 + 60, v/v; pH adjusted to 4.5 +/- 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.1-1 microg/mL with mean recovery of 99.49 +/- 0.83% for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 8-20 microg/mL with mean recovery of 99.74 +/- 0.664% for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder.  相似文献   

15.
A high performance liquid chromatography/tandem mass spectrometry assay was first developed and validated for the quantification of methyl protodioscin (MPD), a natural furostanol saponin with distinct antitumor activity, in rat plasma with 17alpha-ethinylestradiol as internal standard (IS). Methanol-mediated protein precipitation was employed for plasma sample pretreatment. The separation was achieved on a C(18) column (150 x 4.6 mm, i.d., 5 microm) by isocratic elution with methanol-water (72:28, v/v) as mobile phase at a flow rate of 1.0 mL/min. Ion acquisition was performed in selective reaction monitoring positive mode by monitoring the transition of m/z 1085.7 --> 1053.7 for MPD, and in selective ion monitoring negative mode by monitoring the deprotonated ion m/z 295.5 for IS. The assay was linear over the concentration range of 2.024-270.0 microg/mL with 2.024 microg/mL as the lower limit of quantification. It was specific, accurate, precise and reproducible with intra- and inter-run RSD <8.3% and RE between -11.5 and 12.8%. The assay was successfully applied to a preclinical pharmacokinetic study after an intravenous dose of 40 mg/kg MPD to rats.  相似文献   

16.
Dimethyl benzoylphenyl urea (BPU) inhibited tubulin polymerization, caused microtubule depolymerization in vitro and demonstrated activity against solid tumors. BPU is being tested in phase I clinical trials. A rapid and specific method using LC/UV has been developed for quantitation of BPU in human heparin-containing plasma to perform pharmacokinetic and pharmacodynamic studies. BPU is extracted from plasma into acetonitrile:n-butyl-chloride using paclitaxel as the internal standard and separated on a Waters Symmetry C18 (3.9 x 150 mm, 5 microm) column with acetonitrile-water mobile phase (70:30, v/v) using isocratic flow at 1 mL/min for a run time of 5 min. Ultraviolet detection was utilized and performed at 225 nm for BPU and paclitaxel. The retention times were 1.9 min for paclitaxel and 4.1 min for BPU. Calibration curves were generated over the range of 0.01-10 microg/mL with coefficient of determination of > 0.99. The values for within-day and between-day precision were < or = 17.0% at the LLOQ and < or = 7.4% at the low, medium and high quality controls; accuracy was +/- 5.4%. Following administration of BPU 320 mg as a weekly oral dose to a patient with advanced solid tumor malignancies, the maximum plasma concentration was 2 micro g/mL and concentrations were quantifiable up to 168 h after administration. The lower limit of quantitation of 0.01 microg/mL allows for successful measurement of plasma concentrations in patients.  相似文献   

17.
高效液相色谱-柱前衍生化法测定饲料中的含硫氨基酸   总被引:1,自引:0,他引:1  
Yu S  Feng S  Sun Y  Tang T  Han J  Wang F  Li T 《色谱》2011,29(3):239-243
发展了一种饲料中含硫氨基酸的检测方法。样品经过甲酸氧化,将其中的胱氨酸和蛋氨酸分别氧化为磺基丙氨酸和蛋氨酸砜;再经酸水解后,采用2,4-二硝基氟苯进行柱前衍生化,衍生物经高效液相色谱分析。使用Elite AAK C18色谱柱(250 mm×4.6 mm, 5 μm)分离;以0.05 mol/L乙酸钠和乙腈-水(50:50, v/v)为流动相,梯度洗脱,流速为1.2 mL/min;检测波长为360 nm;柱温为31 ℃。结果表明,胱氨酸在0.4~16.0 mg/L、蛋氨酸在0.7~29.6 mg/L范围内的线性相关系数分别为0.9999、0.9998;胱氨酸和蛋氨酸的定量限(信噪比(S/N)=10)分别为2.6 μg/kg和3.1 μg/kg;3次样品平行测定的胱氨酸和蛋氨酸含量的相对标准偏差(RSD)分别为0.79%和2.56%,加标回收率分别为100.28%~102.00%和105.72%~107.89%。该方法分析成本低,测定结果准确,灵敏度高,符合饲料中含硫氨基酸的检测要求。  相似文献   

18.
19.
A simple and rapid high-performance liquid chromatographic method with UV detection is developed and validated to determine the concentration of voriconazole in rat and beagle dog plasma. After protein precipitation using acetonitrile, the supernatant solution is chromatographed on a Diamonsil C(18) column (250 x 4.6-mm i.d., 5 microm). The mobile phase used is a combination of acetonitrile-water-acetic acid (55:45:0.25, v/v/v) with a pH of 4.0. Detection is achieved by a UV detector monitored at a wavelength of 256 nm. The matrix calibration curves are obtained both in the concentration range of 0.10-50.0 microg/mL in rat and beagle dog plasma, with the lower limit of quantitation of 0.10 microg/mL. The intra- and inter-assay precisions in terms of % relative standard deviation are lower than 8.6% and 6.0% in rat and beagle dog plasma, respectively. The accuracy in terms of % relative error ranged from -0.5% to 8.0% and -0.5% to 6.0% in rat and beagle dog plasma, respectively. This validated method is successfully applied to determine the concentration of voriconazole in plasma after intravenous administration of 36 mg/kg voriconazole to rats and 10 mg/kg voriconazole to beagle dogs, respectively.  相似文献   

20.
An isocratic HPLC method with detection at 248 nm was developed and fully validated for the determination of tigecycline in rabbit plasma. Minocycline was used as an internal standard. A Hypersil BDS RP-C18 column (250 x 4.6 mm, 5 microm particle size) was used with the mobile phase phosphate buffer (pH 7.10, 0.070 M)-acetonitrile (76 + 24, v/v) at a flow rate of 1.0 mL/min. The elution time of tigecycline and minocycline was approximately 8.1 and 9.9 min, respectively. Calibration curves of tigecycline were linear in the concentration range of 0.021-3.15 microg/mL in plasma. The LOD and LOQ in plasma were estimated as 7 and 21 ng/mL, respectively. The intraday and interday precision values of the method were in the range of 5.0-7.1 and 5.6-9.1%, while the corresponding accuracy values were in the ranges of 92.8-111.1 and 97.6-102.3%, respectively. At the LOQ, the intraday precision was 18.7%, while intraday and interday accuracy values were 97.3 and 98.0%, respectively. Robustness of the proposed method was studied using a Plackett-Burman experimental design. A pharmacokinetic profile is presented for confirmation of the applicability of the method to pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号