首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
基于微流控芯片试样引入技术的研究是目前微流控芯片分析领域内的重要研究方向之一,其目的是实现宏观外部系统(进行10^-6~1L级液体的操作)与芯片系统(进行10^-12~10^-9 L级液体的操作)的衔接(world-to-chip interfacing).目前文献报道的微流控分析系统,包括芯片流动注射系统,  相似文献   

2.
He QH  Fang Q  Du WB  Fang ZL 《Electrophoresis》2007,28(16):2912-2919
A fabrication process for producing monolithic sampling probes on glass chips, with tip diameters of a few hundred micrometers was developed, using simple tools including a glass cutter and a bench drill. Microfluidic chips with probes fabricated by this approach were coupled to a linearly moving slotted-vial array sample presentation system for performing continuous sample introduction in the chip-based CE system. On-chip horizontal tubular reservoirs containing working electrolyte and waste were used to maintain a stable hydrostatic pressure in the chip channels during prolonged working periods. The performance of the system was demonstrated in the separation of FITC-labeled amino acids with LIF detection, by continuously introducing a train of different samples without interruption. Throughputs of 30-60/h were achieved with <1.0% carry-over and reproducibilities in peak height of 3.6, 3.3, and 3.5% RSD for arginine, FITC, and phenylalanine, respectively (n = 11). Continuous analysis of a mixture of FITC-labeled amino acids for 2 h, involving 60 analytical cycles, yielded an RSD of 7.5 and 6.8% for arginine and FITC (n = 60), respectively. An extremely low sample consumption of 30 nL for each analysis was obtained. Separation efficiencies in plate numbers were in the range of 0.8-2x10(5)/m. In addition to the application in sample introduction, the sample/reagent introduction system was also used to produce working electrolyte gradients during a CE separation to improve the separation efficiency. Comparing with isocratic electrophoresis separation, gradient CE demonstrated better separation efficiencies for a mixture of FITC-labeled amino acids.  相似文献   

3.
A new sensitive method has been developed for the determination of haloalkane dehalogenase activity. The enzymatic reactions were carried out directly in thermostatted autosampler vials and the formation of product - bromide or chloride ions - was monitored by sequential capillary zone electrophoresis runs. The determinations were performed in a 75 microm fused-silica capillary using 5 mM chromate, 0.5 mM tetradecyltrimethylammonium bromide (pH 8.4) as a background electrolyte, separation voltage 15 kV (negative polarity) and indirect detection at sample wavelength 315 nm, reference wavelength 375 nm for brominated and chlorinated substrates, respectively 0.1 M beta-alanine-HCl (pH 3.50) as a background electrolyte, separation voltage 18 kV (negative polarity) and direct detection at 200 nm for brominated substrates. The temperature of capillary was in both cases 25 degrees C. The method is rapid, can be automated, and requires only small amount of enzyme preparation and substrate.  相似文献   

4.
A multi-T microchip for integrated field amplified sample stacking (FASS) with CE separation to increase the chip-based capillary electrophoresis (chip-based CE) sensitivity was developed. Volumetrically defined large sample plug was formed in one step within 5s by the negative pressure in headspace of the two sealed sample waste reservoirs produced using a syringe pump equipped with a 3-way valve. Stacking and separation can proceed only by switching the 3-way valve to release the vacuum in headspace of the two sample waste reservoirs. This approach considerably simplified the operations and the equipments for FASS in chip-based CE systems. Migration time precisions of 3.3% and 1.3% RSD for rhodamine123 (Rh123) and fluorescien sodium salt (Flu) in the separation of a mixture of Flu and Rh123 were obtained for nine consecutive determinations with peak height precisions of 4.8% and 3.4% RSD, respectively. Compared with the chip-based CE on the cross microchip, the sensitivity for analysis of FlTC, FITC-labeled valine (Val) and Alanine (Ala) increased 55-, 41- and 43-fold, respectively.  相似文献   

5.
Phillips TM 《Electrophoresis》2004,25(10-11):1652-1659
A chip-based capillary electrophoresis system has been designed for rapidly measuring the concentrations of inflammatory cytokines in the cerebrospinal fluid of patients with head trauma. Isolation of the reactive cytokines was achieved by immunoaffinity capture using a panel of six immobilized antibodies, directly attached to the injection port of the chip. The captured cytokines were labeled in situ with a red light-emitting laser dye and electroeluted into the separation channel. Separation of the isolated cytokines was achieved by electrophoresis in under 2 min with quantification of the resolved peaks being achieved by on-line laser-induced fluorescence and integration of each peak area. Comparison of the results to commercially available high-sensitivity immunoassays demonstrates that the chip-based assay provides a fast, accurate procedure for studying the concentrations of these analytes in complex biological materials. The degree of accuracy and precision achieved by the chip-based CE is comparable to conventional immunoassays, the system being able to analyze between 10-12 samples per hour. With the ever-expanding array of antibodies that are commercially available, this chip-based system can be applied to a wide variety of different analyses.  相似文献   

6.
Chen G  Wang J 《The Analyst》2004,129(6):507-511
A newly designed capillary electrophoresis (CE) microchip with a simple and efficient sample introduction interface is described. The sample introduction is carried out directly on the separation channel through a sharp inlet tip placed in the sample vial, without an injection cross, complex microchannel layouts or hardware modification. Alternate placement of the inlet tip in vials containing the sample and buffer solutions permits a volume defined electrokinetic sample introduction. Such fast and simple sample introduction leads to highly reproducible signals with no observable carry over between different analyte concentrations. The performance of the system was demonstrated in flow-injection and CE measurements of nitroaromatic explosives and for on-chip enzymatic assays of glucose in the presence of ascorbic acid. Employing an 8 cm long separation channel and a separation voltage of 4000 V it offers high-throughput flow-injection assays of 100 samples h(-1) with a relative standard deviation of 3.7% for TNT (n= 100). Factors influencing the analytical performance of the new microchip have been characterized and optimized. Such ability to continuously introduce discrete samples into micrometer channels indicates great promise for high-speed microchip analysis.  相似文献   

7.
Wellner EF  Kalish H 《Electrophoresis》2008,29(16):3477-3483
A chip-based capillary electrophoresis system has been designed for assessing the concentrations of four hormones in whole human blood, saliva, and urine. The desired analytes were isolated by immunoextraction using a panel of four analyte-specific antibodies immobilized onto a glass fiber insert within the injection port of the chip. Following extraction, the captured analytes were labeled prior to electro-elution into the chip separation channel, where they were resolved into four individual peaks in circa 2 min. Quantification of each peak was achieved by on-line LIF detection and integration of the area under each peak. Comparison to commercial high-sensitivity immunoassays demonstrated that the chip-based assay provided fast, accurate, and precise measurements for the analytes under investigation. As the availability of commercially available antibodies rapidly expands, the application of this system will greatly increase. Chip-based CE separations of multiple analytes from a single sample also provide a significant advantage in the analysis of small samples.  相似文献   

8.
董娅妮  方群 《色谱》2008,26(3):269-273
重点介绍了近年来国内外在微流控芯片毛细管电泳法用于蛋白质分离分析方面的研究进展。按照分离模式的不同,综述了各种应用于蛋白质分离的微流控芯片毛细管电泳系统,讨论了抑制芯片中的蛋白吸附的各种方法,并展望了芯片毛细管电泳系统在蛋白质分离领域的发展前景。引用文献47篇。  相似文献   

9.
Phillips TM  Wellner EF 《Electrophoresis》2007,28(17):3041-3048
To aid in the biochemical analysis of human skin biopsies, a semiautomatic chip-based CE system has been developed for measuring inflammatory biomarkers in microdissected areas of the biopsy. Following solubilization of the dissected tissue, the desired biomarkers were isolated by immunoaffinity capture using a panel of 12 antibodies, immobilized on a disposable glass fiber disk, within the extraction port of the chip. The captured analytes were labeled with a 635 nm light-emitting laser dye and electroeluted into the separation channel. Electrophoretic separation of all of the analytes was achieved in 2.2 min with quantification of each peak being performed by online LIF detection and integration of each peak area. Comparison of the results obtained from the chip-based system to those obtained using commercially available high-sensitivity immunoassays demonstrated that the chip-based assay provides a fast, accurate procedure for studying the concentrations of inflammatory biomarkers in complex biological materials. The degree of accuracy and precision achieved by the chip-based CE is comparable to conventional immunoassays and the system is capable of analyzing circa six samples per hour. With the ever-expanding array of antibodies that are commercially available, this chip-based system can be applied to a wide variety of different biomedical analyses.  相似文献   

10.
Yang X  Zhang X  Li A  Zhu S  Huang Y 《Electrophoresis》2003,24(9):1451-1457
A novel comprehensive two-dimensional (2-D) separation system coupling capillary high-performance liquid chromatography (cHPLC) with microchip electrophoresis (chip CE) is demonstrated. Reversed-phase cHPLC was used as the first dimension, and chip CE acted as the second dimension to perform fast sample transfers and separations. A valve-free gating interface was devised simply by inserting the outlet-end of LC column into the cross-channel on a specially designed chip. A home-made confocal laser-induced fluorescence detector was used to perform on-chip high-sensitive detection. The cHPLC effluents were continuously delivered to the chip and pinched injections of the effluents every 20 seconds were employed for chip CE separation. Gradient elution of cHPLC was carried out to obtain the high-efficiency separation. Free-zone electrophoresis was performed with triethylamine buffer to achieve high-speed separation and prevent sample adsorption. Such a simple-made comprehensive system was proved to be effective. The relative standard deviations for migration time and peak height of rhodamine B in 150 sample transfers were 3.2% and 9.8%, respectively. Peptides of the fluorescein isothiocyanate (FITC)-labeled tryptic digests of bovine serum albumin were fairly resolved and detected with this comprehensive 2-D system.  相似文献   

11.
An improved automated continuous sample introduction system for microfluidic capillary electrophoresis (CE) is described. A sample plate was designed into gear-shaped and was fixed onto the shaft of a step motor. Twenty slotted reservoirs for containing samples and working electrolytes were fabricated on the “gear tooth” of the plate. A single 7.5-cm long Teflon AF-coated silica capillary serves as separation channel, sampling probe, as well as liquid-core waveguide (LCW) for light transmission. Platinum layer deposited on the capillary tip serves as the electrode. Automated continuous sample introduction was achieved by scanning the capillary tip through the slots of reservoirs. The sample was introduced into capillary and separated immediately in the capillary with only about 2-nL gross sample consumption. The laser-induced fluorescence (LIF) method with LCW technique was used for detecting fluorescein isothiocyanate (FITC)-labeled amino acids. With electric-field strength of 320 V/cm for injection and separation, and 1.0-s sample injection time, a mixture of FITC-labeled arginine and leucine was separated with a throughput of 60/h and a carryover of 2.7%.  相似文献   

12.
Yeh HH  Yang YH  Ko JY  Chen SH 《Electrophoresis》2008,29(17):3649-3657
Field-amplified sample stacking (FASS) in capillary electrophoresis (CE) was used to determine the concentration of donepezil, an acetylcholinesterase inhibitor, in human plasma. A sample pretreatment by liquid-liquid extraction with isopropanol/n-hexane (v/v 3:97) and subsequent quantification by FASS-CE was used. Before sample loading, a water plug (0.5 psi, 6 s) was injected to permit FASS. Electrokinetic injection (7 kV, 90 s) was used to introduce sample cations. The separation condition for donepezil was performed in electrolyte solutions containing Tris buffer (60 mM, pH 4.0) with sodium octanesulfonate 40 mM and 0.01% polyvinyl alcohol as a dynamic coating to reduce analytes' interaction with capillary wall. The separation was performed at 28 kV and detected at 200 nm. Using atenolol as an internal standard, the linear ranges of the method for the determination of donepezil in human plasma were over a range of 1-50 ng/mL. The limit of detection was 0.1 ng/mL (S/N=3, sampling 90 s at 7 kV). One female volunteer (54 years old) was orally administered a single dose of 10 mg donepezil (Aricept, Eisai), and blood samples were drawn over a 60 h period for pharmacokinetic study. The method was also applied successfully to monitor donepezil in sixteen Alzheimer's disease patients' plasmas.  相似文献   

13.
Zhang L  Yin X 《Electrophoresis》2007,28(8):1281-1288
A simple and powerful microfluidic array chip-based electrophoresis system, which is composed of a 3-D microfluidic array chip, a microvacuum pump-based negative pressure sampling device, a high-voltage supply and an LIF detector, was developed. The 3-D microfluidic array chip was fabricated with three glass plates, in which a common sample waste bus (SW(bus)) was etched in the bottom layer plate to avoid intersecting with the separation channel array. The negative pressure sampling device consists of a microvacuum air pump, a buffer vessel, a 3-way electromagnet valve, and a vacuum gauge. In the sample loading step, all the six samples and buffer solutions were drawn from their reservoirs across the injection intersections through the SW(bus) toward the common sample waste reservoir (SW(T)) by negative pressure. Only 0.5 s was required to obtain six pinched sample plugs at the channel crossings. By switching the three-way electromagnetic valve to release the vacuum in the reservoir SW(T), six sample plugs were simultaneously injected into the separation channels by EOF and electrophoretic separation was activated. Parallel separations of different analytes are presented on the 3-D array chip by using the newly developed sampling device.  相似文献   

14.
Liu FK 《Analytica chimica acta》2011,694(1-2):167-173
In this study, gold nanoparticles (Au NPs) were separated using the reversed electrode polarity stacking mode (REPSM) of a capillary electrophoresis (CE) system for on-line enhancement prior to performing surfactant-modified CE separation. Under optimized conditions [running electrolyte buffer, sodium dodecyl sulfate (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (10 mM) at pH 10.0; applied voltage, 20 kV; operating temperature, 25°C; REPSM strategy for sample on-line concentration; REPSM applied prior to initializing separation], two parameters were varied to further enhance the concentration and separation of the Au NPs: (i) the rate of polarity switching (from -20 to +20 kV) between the REPSM and surfactant-modified CE separation modes and (ii) the length of the capillary column. At a polarity switching rate of 1333 kV min(-1) and a column length of ca. 83.5 cm, the resolution of the separation of a mixture of 5.3- and 40.1-nm Au NPs was greater than 19; in addition, the numbers of theoretical plates for the 5.3- and 40.1-nm-diameter Au NPs were greater than 15,000 and up to 1.15×10(7), respectively-the latter being extremely high. Thus, this CE-based method for separating Au NPs provided high performance in terms of separation resolution and the number of theoretical plates, both of which were improved by greater than fivefold relative to those published previously. Notably, the sensitivity enhancement factors for the 5.3- and 40.1-nm-diameter Au NPs were improved (by ca. 20- and 500-fold, respectively) relative to those obtained using conventional surfactant-modified CE separation.  相似文献   

15.
A new sensitive method has been developed for the determination of rhodanese activity. The enzymatic reactions were carried out directly in thermostatted autosampler vials and the formation of SCN- was monitored by sequential capillary zone electrophoretic runs. The determinations were performed in a 75-micron fused-silica capillary using 0.1 M beta-alanine-HCl (pH 3.50) as a background electrolyte, a separation voltage of 18 kV (negative polarity), a capillary temperature of 25 degrees C and direct detection at 200 nm. Short-end injection or long-end injection procedures were used for sample application. The method is rapid, able to be automated and requires only small amounts of sample and substrates, which is especially important in the case of highly toxic cyanide. The developed capillary electrophoretic method also has great potential for thiocyanate determinations in other applications.  相似文献   

16.
A method has been developed for determination of vanadium, as an anionic ternary complex of vanadium(V) with 4-(2-pyridylazo) resorcinol (PAR) and hydrogen peroxide, after separation by capillary electrophoresis (CE). The optimum conditions for the formation of the ternary complex were acetate buffer (3 mmol L(-1)) at pH 6 containing 0.15 mmol L(-1) PAR and 7.1 mmol L(-1) H(2)O(2). The CE separation was conducted using 15 mmol L(-1) acetate buffer at pH 6 as the background electrolyte; the separation potential was -30 kV and the injection time 100 s. The vanadium complex was detected photometrically at 568 nm, by use of a light-emitting diode (LED); the detection limit was 19 ppb. The method was applied to the analysis of vanadium in fertilisers. Clean-up of the digested fertiliser sample, with Sep-Pak C(18) coated with tetrabutylammonium hydroxide, before analysis was used to remove matrix ions which otherwise caused electrophoretic de-stacking. Vanadium levels found in the fertiliser samples by use of the CE method were found to be comparable with results obtained by HPLC and ICP-MS.  相似文献   

17.
A method was developed for the determination of phosphoamino acids by capillary zone electrophoresis-laser-induced fluorescence detection (argon ion laser, excitation at 488 nm and emission at 520 nm) using derivatization with N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA). Different variables affecting the derivatization (SIFA concentration, derivatization pH, reaction temperature and reaction time) and the separation (type, pH and concentration of buffer, applied voltage and injection mode) were investigated in detail. The optimized separation conditions were 40 mM boric acid buffer (pH 9.2) for background electrolyte, 25 kV for the separation voltage, 25 degrees C for the capillary temperature and 5 s at 0.5 psi for the sample injection. Under the optimal conditions, the SIFA-labeled phosphoamino acids were fully separated within 7 min. The detection limits ranged from 0.1 to 0.3 nM, which are the lowest values reported for capillary electrophoresis (CE) methods. The proposed methodology allowed the rapid, sensitive and selective determination of phosphoamino acids in hen egg yolk phosvitin by the standard addition method. The recovery of these compounds in real sample was 94.0-103.5%. The developed method surpasses previously published CE methods in terms of detection limit, separation time, stability and simplicity of the electrophoretic procedure.  相似文献   

18.
Capillary electrophoresis (CE) holds great promise as an in situ analytical technique for a variety of applications. However, typical instrumentation operates with open reservoirs (e.g., vials) to accommodate reagents and samples, which is problematic for automated instruments designed for space or underwater applications that may be operated in various orientations. Microgravity conditions add an additional challenge due to the unpredictable position of the headspace (air layer above the liquid) in any two-phase reservoir. One potential solution for these applications is to use a headspace-free, flow-through reservoir design that is sealed and connected to the necessary reagents and samples. Here, we demonstrate a flow-through high-voltage (HV) reservoir for CE that is compatible with automated in situ exploration needs, and which can be electrically isolated from its source fluidics (in order to prevent unwanted leakage current). We also demonstrate how the overall system can be rationally designed based on the operational parameters for CE to prevent electrolysis products generated at the electrode from entering the capillary and interfering with the CE separation. A reservoir was demonstrated with a 19 mm long, 1.8 mm inner diameter channel connecting the separation capillary and the HV electrode. Tests of these reservoirs integrated into a CE system show reproducible CE system operation with a variety of background electrolytes at voltages up to 25 kV. Rotation of the reservoirs, and the system, showed that their performance was independent of the direction of the gravity vector.  相似文献   

19.
The application of chemometric techniques to the resolution of overlapped peaks in capillary electrophoresis (CE) is described. When a physical separation can not be completely accomplished, chemometrics might still resolve the determination of the analytes mathematically. CE with diode array detection can provide a large amount of data consisting of spectra registered over time. In this study, the capillary electrophoretic separation of 1,2-naphthoquinone-4-sulfonate derivatives of amino acids is studied. Most of the common amino acid derivatives can be separated at 30 kV in a fused-silica capillary by using a 40 mM sodium tetraborate + isopropanol (3:1 v/v) solution as background electrolyte. However, peaks of certain derivatives (Phe, His, Leu and Ile) still overlap. A multivariate curve resolution method based on an alternating least squares optimization procedure is used for the resolution of the overlapped electrophoretic peaks. The method takes advantage of spectral and electrophoretic differences of analytes to recover their pure electrophoretic and spectral profiles. In addition, each analyte in the mixture can be quantified using the corresponding standards.  相似文献   

20.
Wang CC  Chiou SS  Wu SM 《Electrophoresis》2005,26(13):2637-2642
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号