首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new electrochemical method was proposed for the determination of adenosine‐5′‐triphosphate (ATP) based on the electrooxidation at a molecular wire (MW) modified carbon paste electrode (CPE), which was fabricated with diphenylacetylene (DPA) as the binder. A single well‐defined irreversible oxidation peak of ATP appeared on MW‐CPE with adsorption‐controlled process and enhanced electrochemical response in a pH 3.0 Britton‐Robinson buffer solution, which was due to the presence of high conductive DPA in the electrode. The electrochemical parameters of ATP were calculated with the electron transfer coefficient (α) as 0.54, the electron transfer number (n) as 1.9, the apparent heterogeneous electron transfer rate constant (ks) as 2.67 × 10?5 s?1 and the surface coverage (ΓT) as 4.15 × 10?10 mol cm?2. Under the selected conditions the oxidation peak current was proportional to ATP concentration in the range from 1.0 × 10?7 mol L?1 to 2.0 × 10?3 mol L?1 with the detection limit as 1.28 × 10?8 mol L?1 (3σ) by sensitive differential pulse voltammetry. The proposed method showed good selectivity without the interferences of coexisting substances and was successful applied to the ATP injection samples detection.  相似文献   

2.
A sensor based in a graphite–polyurethane composite electrode modified with the mesoporous nanostructured silica with hexagonal array of pores called Santa Barbara Amorphous type material (SBA‐15) containing nickel was built. The presence of Ni, incorporated during the synthesis of SBA‐15, resulted in an increase in sensitivity when compared to the other electrodes based on the unmodified SBA‐15. A procedure was proposed for the determination of Cu2+ in ethanol biofuel by square wave stripping voltammetry with linear response in concentration levels of 1.0×10?8 and 1.0×10?7 mol L?1, resulting in a limit of detection of 1.83×10?10 mol L?1 and precision (RSD) of 2.09 %.  相似文献   

3.
Three types of ion‐selective electrodes: PVC membrane, modified carbon paste (CPE), and coated graphite electrodes (CGE) have been constructed for determining paroxetine hydrochloride (Prx). The electrodes are based on the ion pair of paroxetine with sodium tetraphenylborate (NaTPB) using dibutyl phthalate as plasticizing solvent. Fast, stable and potentiometric response was obtained over the concentration range of 1.1×10?5–1×10?2 mol L?1 with low detection limit of 6.9×10?6 mol L?1 and slope of a 56.7±0.3mV decade?1 for PVC membrane electrode, the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 1.2×10?5 mol L?1 and slope of a 57.7±0.6 mV decade?1 for CPE, and the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 8.9×10?6 mol L?1 and slope of a 56.1±0.1 mV decade?1 for CGE. The proposed electrodes display good selectivity for paroxetine with respect to a number of common inorganic and organic species. The electrodes were successfully applied to the potentiometric determination of paroxetine hydrochloride in its pure state, its pharmaceutical preparation, human urine and plasma.  相似文献   

4.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

5.
《Electroanalysis》2006,18(10):1028-1034
This paper presents a comparative study on the electrochemical behavior of the flavonoid rutin on a rigid carbon‐polyurethane composite electrode and on a glassy carbon electrode. The electrochemical oxidation reaction of rutin was found to be quasireversible and affected by adsorption on the electrode surface. A square‐wave voltammetric method was developed for determination of rutin in green tea infusion samples using the RCPE electrode and data treatment by a deconvolution procedure. The detection limit achieved in buffered solutions was 7.1×10?9 mol L?1 using the RCPE and 1.7×10?8 mol L?1 using the GC electrode the average reproducibility for five determinations being 3.5%.  相似文献   

6.
In this paper a new electrochemical method based on the ionic liquid modified carbon paste electrode (IL‐CPE) was proposed for the determination of adenosine‐5′‐triphosphate (ATP) in a pH 4.5 Britton‐Robinson (B‐R) buffer solution. IL‐CPE was prepared by using 1‐butyl‐3‐methylimidazolium trifluoroacetate (BMIMCF3COO) as the modifier. Cyclic voltammetry was used to investigate the electrochemical behaviors of ATP on the IL‐CPE, and the results indicated that IL‐CPE exhibited strong electrocatalytic ability to promote the oxidation of ATP with a single well‐defined irreversible adsorption‐controlled oxidation peak appeared. The electrochemical reaction parameters of ATP were calculated with the results of the electron transfer coefficient (α) as 0.40, the electron transfer number (n) as 1.17, the apparent heterogeneous electron transfer rate constant (ks) as 3.66 × 10‐6 s‐1 and the surface coverage (Γτ) as 2.48 × 10‐9 mol cm‐2. Under the selected conditions the proposed IL‐CPE showed good performances to the ATP detection in the concentration range from 0.1 to 1000.0 μmol L‐1 with the detection limit as 3.65 × 10‐8 mol L‐1 (3σ) by differential pulse voltammetry. The method showed good selectivity to the ATP detection without the interferences of coexisting substances and was successfully applied to the ATP injection samples detection with satisfactory results.  相似文献   

7.
The electrochemical impedance spectroscopy (EIS) has been used to study the interaction between paraquat and carbon modified by silver (Ag? CPE) and silver particles‐impregnated natural phosphate (Ag/NPh? CPE). This study was developed using spectrophotometry (UV? Vis) and infrared spectroscopy. The resulting interaction was controlled by adsorption at lower concentration (≤1.0×10?5 mol L?1) and by diffusion in the opposite case. Both electrodes are used to determining paraquat with a low detection limit (<1.0×10?12 mol L?1). The precision expressed as relative standard deviation RSD for the concentration level 1.0×10?5 mol L?1 of paraquat, (n=8) were 0.93 % and 1.1 % for Ag/NPh? CPE and Ag? CPE respectively.  相似文献   

8.
An ionic liquid (IL) 1‐(3‐chloro‐2‐hydroxy‐propyl)‐3‐methylimidazolium trifluoroacetate was used as the modifier for the preparation of the modified carbon paste electrode (CPE). The IL‐CPE showed excellent electrocatalytic activity towards the oxidation of guanosine‐5′‐triphosphate (5′‐GTP) in a pH 5.0 Britton‐Robinson buffer solution. Due to the presence of high conductive IL on the electrode surface, the electrooxidation of 5′‐GTP was greatly promoted with a single well‐defined irreversible oxidation peak appeared. The electrode reaction was an adsorption‐controlled process and the electrochemical parameters of 5′‐GTP on IL‐CPE were calculated with the electron transfer coefficient (α) as 0.44, the electron transfer number (n) as 1.99, the apparent heterogeneous electron transfer rate constant (ks) as 2.21 × 10?9 s?1 and the surface coverage (ΓT) as 1.53 × 10?10 mol cm?2. Under the selected conditions a linear calibration curve between the oxidation peak currents and 5′‐GTP concentration was obtained in the range from 2.0 to 1000.0 μmol L?1 with the detection limit as 0.049 μmol L?1 (3σ) by differential pulse voltammetry. The proposed method showed good selectivity to the 5‘‐GTP detection without the interferences of coexisting substances and the practical application was checked by measurements of the artificial samples.  相似文献   

9.
The article describes the use of a fullerene (C60)‐β‐cyclodextrin conjugate, synthesized via 1,3dipolar cycloaddition, for the ultrasensitive electrochemical detection of p‐nitrophenol. This conjugate was successfully immobilized on the surface of a glassy carbon electrode and the developed device showed high activity towards p‐nitrophenol due to the synergetic effect of C60, the latter becoming highly conductive upon reduction. The determination of p‐nitrophenol was performed by using square wave voltammetry over a concentration range from 2.8×10?9 mol L?1 to 4.2×10?7 mol L?1 and the detection limit was calculated to be 1.2×10?9 mol L?1.  相似文献   

10.
Using 3‐Aminopropyltriethoxysilane(APTES) as a single silica source, an amino‐rich ultrafine organosilica‐nanoparticle‐modified Au electrode was fabricated, following the formation of (3‐mercaptopropyl)‐trimethoxysilane (MPTS) monolayer on Au surface (MPTS/Au). With cetyltrimethylammonium bromide as an additive, APTES‐based gel particles on the electrode have a narrow particle size distribution of 4–7 nm and “crystal‐like” structure. AFM and electrochemical characterization confirmed the successful grafting of APTES nanoparticles on MPTS/Au. The APTES/MPTS/Au electrode is highly sensitive for the detection of copper(II) ions with a detection limit as low as 1.6×10?12 mol L?1 (S/N>3) by square wave voltammetry. The current is linear to copper(II) concentration between 1.6×10?12 and 6.25×10?10 mol L?1.  相似文献   

11.
The sol-gel derived glucose biosensor was developed, and the sol-gel membrane was organically modified by N-(3-triethoxysilylpropyl)-ferrocenylmethylamine (FcSi) as sol-gel precursor to make electrochemical biosensor. The structure of biosensor was sol-gel/FcSi+GOx/GC type (glucose oxidase, GOx). The ferrocene mediator was chemically immobilized to the silane network, and GOx was entrapped to the sol-gel glass network. Therefore, these structures prevented mediator leakage and retained the enzyme activity. Additionally, pH of electrolyte, temperature effects, and interference of positive substances with biosensor were investigated. And the electrochemical performance of biosensor was studied by amperometry. The results indicated that the linear range, detection limit. and response slope of biosensor was 2.00×10^-4-1.57×10^-3 mol·L^-1, 2.0×10^-4 mol·L^-1 and 5.06×10^5 nA·mol^- 1·L, respectively.  相似文献   

12.
A cobalt oxide nanocluster/overoxidized polypyrrole composite film electrochemical sensing interface was fabricated by two step electrochemical method. The electrochemical properties and electrocatalytic activity of the resulting modified electrode were also studied carefully. The results showed that this modified electrode exhibited good stability, good anti‐interference ability, as well as high electrocatalytic activity to the oxidation of glucose. The linear range for the amperometric determination of glucose was 2.0×10?7–2.4×10?4 mol L?1 and 2.4×10?4–1.4×10?3 mol L?1 with a detection limit of 5.0×10?8 mol L?1 (S/N=3), respectively. The sensitivity was 1024 µA mM?1 cm?2.  相似文献   

13.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

14.
《Analytical letters》2012,45(4):678-688
Abstract

MCM-41 was synthesized with uniform pore networks and then used to modify a carbon-paste electrode (CPE). The electrochemical behavior of rutin was investigated. Compared with the bare CPE, the MCM-41–modified CPE remarkably enhances the redox peak currents of rutin, attributed to large surface area, high sorption capacity, and specific mesopores. Based on this, a sensitive and convenient electrochemical method was developed for the analysis of rutin. The linear range is from 2.0 × 10?8 to 1.0 × 10?6 mol L?1, and the limit of detection is 1.5 × 10?8 mol L?1. Finally, this method was employed to determine rutin in traditional Chinese medicines.  相似文献   

15.
A new modified carbon paste electrode (CPE) based on a recently synthesized ligand [2‐mercapto‐5‐(3‐nitrophenyl)‐1,3,4‐thiadiazole] (MNT), self‐assembled to gold nanoparticles (GNP) as suitable carrier for Cd(II) ion with potentiometric method are described. The proposed electrode exhibits a Nernstian slope of 29.4±1.0 mV per decade for Cd(II) ion over a wide concentration range from 3.1×10?8 to 3.1×10?4 mol L?1. The detection limit of electrode was 2.0×10?8 mol L?1 of cadmium ion. The potentiometric responses of electrode based on MNT is independent of the pH of test solution in the pH range 2.0–4.0. It has quick response with response time of about 6 s. The proposed electrode show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. Finally, the proposed electrode was successfully employed to detect Cd(II) ion in hair and water samples.  相似文献   

16.
《Electroanalysis》2006,18(3):291-297
Selected from a series of structurally related heteroaromatic thiols, a newly synthesized reagent 2‐amino‐5‐mercapto‐[1,3,4] triazole (MATZ) was used to fabricate self‐assembled monolayers (SAMs) on gold electrode for the first time. The MATZ/Au SAMs was characterized by electrochemical methods and scanning electronic microscopy (SEM). In 0.04 mol/L Britton–Robinson buffer solution (pH 5), the electrochemical behavior of dopamine showed a quasireversible process at the MATZ/Au SAMs with an electrode kinetic constant 0.1049 cm/s. However, the electrochemical reaction of uric acid at the SAMs electrode showed an irreversible oxidation process, the charge‐transfer kinetics of uric acid was promoted by the SAMs. By Osteryoung square‐wave voltammetry (OSWV), the simultaneous determination of dopamine and uric acid can be accomplished with an oxidation peak separation of 0.24 V, the peak current of dopamine and uric acid were linearly to its concentration in the range of 2.5×10?6–5.0×10?4 mol/L for dopamine and 1×10?6–1×10?4 mol/L for uric acid with a detection limit of 8.0×10?7 mol/L for dopamine and 7.0×10?7 mol/L for uric acid. The MATZ/Au SAMs electrode was used to detect the content of uric acid in real urine and serum sample with satisfactory results.  相似文献   

17.
In this paper a molecular wire modified carbon paste electrode (MW‐CPE) was firstly prepared by mixing graphite powder with diphenylacetylene (DPA). Then a graphene (GR) and chitosan (CTS) composite film was further modified on the surface of MW‐CPE to receive the graphene functionalized electrode (CTS‐GR/MW‐CPE), which was used for the sensitive electrochemical detection of adenosine‐5′‐triphosphate (ATP). The CTS‐GR/MW‐CPE exhibited excellent electrochemical performance and the electrochemical behavior of ATP on the CTS‐GR/MW‐CPE was carefully studied by cyclic voltammetry with an irreversible oxidation peak appearing at 1.369 V (vs. SCE). The electrochemical parameters such as charge transfer coefficient (α) and electrode reaction standard rate constant (ks) were calculated with the results of 0.53 and 5.28×10?6 s?1, respectively. By using differential pulse voltammetry (DPV) as detection technique, the oxidation peak current showed good linear relationship with ATP concentration in the range from 1.0 nM to 700.0 µM with a detection limit of 0.342 nM (3σ). The common coexisting substances, such as uric acid, ascorbic acid and guanosine‐5′‐triphosphate (GTP), showed no interferences and the modified electrode was successfully applied to injection sample detection.  相似文献   

18.
An ionic liquid N‐hexylpyridinium hexafluorophosphate (HPPF6) modified carbon paste electrode was fabricated for the sensitive voltammetric determination of adenosine in this paper. Carbon ionic liquid electrode (CILE) was prepared by mixing graphite powder and HPPF6 together and the CILE was characterized by scanning electron microscopy (SEM) and electrochemical methods. The electrochemical behaviors of adenosine on the CILE were studied carefully. Compared with the traditional carbon paste electrode (CPE), a small negative shift of the oxidation peak potential appeared with greatly increase of the oxidation peak current, which indicated the presence of ionic liquid in the carbon paste not only as the binder but also as the modifier and promoter. Under the optimal conditions the oxidation peak current increased with the adenosine concentration in the range from 1.0×10?6 mol/L to 1.4×10?4 mol/L with the detection limit of 9.1×10?7 mol/L (S/N=3) by differential pulse voltammetry. The proposed method was applied to the human urine samples detection with satisfactory results.  相似文献   

19.
ABSTRACT

A molecularly imprinted electrochemical sensor for the rapid detection of the anti-parasitic drug Secnidazole (SCZ) is reported. In this work, the build electrochemical sensor was based on a carbon paste electrode (CPE) modified with multi-wall carbon nanotubes (MWCNTs) and boron-embedded duplex molecularly imprinted composite membranes (B-DMICMs), that significantly increased the efficiency of the sensor for the detection of template molecule SCZ. Density functional theory (DFT) was employed to study the interactions between the template and monomers to select appropriate functional monomers for rational design of the B-DMICMs.The optimal experimental conditions were optimised for the factors affecting the performance of the sensor. Under the optimal conditions, the reduction peak currents of SCZ by differential pulse voltammetry increased linearly with SCZ concentration in the range from 3.0 × 10?4 to 1.0 × 1.0?6 mol L?1 and 1.0 × 1.0?6 to 1.91 × 10?8 mol L?1 with a detection limit of 1.72 × 10?8 mol L?1 for secnidazole, which is significantly lower than those in the currently used methods and in previous reports. This method offers low cost, sensitive and effective determination of SCZ and can potentially be used for detection of SCZ in pharmaceutical and biological samples with good precision and accuracy.  相似文献   

20.
Amantadine potentiometric detectors were developed, evaluated and incorporated in a SIA‐LOV manifold in order to accomplish the control of pharmaceutical formulations and urine. The electrodes incorporate α‐cyclodextrin as ionophore, dibutyl phthalate or 2‐fluorophenyl 2‐nitrophenyl ether as plasticizers and potassium tetrakis[3,5‐bis‐(trifluoromethyl)phenyl]borate (KTFPB) as cationic additive. The slope increased from 61.2 to 63.8 mV decade?1 and the practical limit of detection from 2.6×10?6 mol L?1 to 2.5×10?5 mol L?1 when the plasticizer was changed from 2‐fluorophenyl 2‐nitrophenyl ether to dibutyl phthalate. When incorporated in the flow‐manifold the membranes composed by dibutyl phthalate or with 2‐fluorophenyl 2‐nitrophenyl ether presented slopes and a practical limit of detection of 69.8 mV decade?1 and 1.5×10?4 mol L?1 or 73.7 mV decade?1 and 5.4×10?5 mol L?1, respectively. The electrode presented stable responses for over a year, and were highly selective concerning the representative species of the two sample matrices assayed as interferents. Comparison of obtained results with those provided by reference methods and recovery assays, revealed adequate accuracy for control assays.  相似文献   