首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Improved separations of the isomers of olefinic aliphatic insect pheromones were obtained on cholesteryl cinnamate glass capillary columns by operating in the supercooled temperature range of the liquid crystal. Capillary columns were prepared with varying film thickness of the stationary phase; choice of the correct film thickness ensured optimum retention for a wide range of compounds within the most effective temperature range of the liquid crystal. The deactivation procedures described made the liquid crystal columns suitable for separation of the geometric isomers of polar and nonpolar compounds.  相似文献   

2.
合成了聚硅氧烷键合离子液体[PSOMIM][NTf2],并将其用作快速气相色谱柱的固定相.初步探索了采用短柱及小内径毛细管柱(3 m×75 μm i.d.)时的分离性能及固定相膜厚对分离性能的影响.与常规柱(8m×0.25 mmi.d.)相比,在不损失分离度的前提下,分离速度可提高1~6倍;当膜厚为0.056 μm时,可以将分离速度提高2~4倍.实验结果表明,聚硅氧烷键合离子液体固定相可以有效弥补由于缩短柱长所导致的分离度减小的问题,在快速气相色谱固定相方面具有较好的应用前景.  相似文献   

3.
Summary Wall-coated, open-tubular (capillary) columns prepared from different diameter tubing, with different liquid phase film thickness, are compared with each other and with packed and support-coated open-tubular columns. The comparison is based on the variation of the phase ratio and the capacity factor, and includes column efficiency (HETP, theoretical plate number), resolution, retention time, and sample capacity. Problems associated with the evaluation of the sample capacity are outlined. The influence of temperature on column performance is discussed in detail. Finally, the possibilities of short, wide-bore open-tubular columns prepared with a thick liquid-phase film are demonstrated.Parts of this paper were presented at the 35th Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Atlantic City NJ, March 5–9, 1984, and at the 20th International Symposium on Advances in Chromatography, New York NY, April 16–18, 1984.  相似文献   

4.
Summary The factors characterizing the influence of the variation of the liquid phase film thickness on the mass transfer terms in the Golay equations describing the performance of open tubular columns are investigated and numerical values are given.Paper dedicated to Professor S. R. Lipsky on his sixtieth birthday.  相似文献   

5.
6.
李莉  李硕  王海燕  孙磊 《色谱》2022,40(2):190-197
以化妆品中23种防腐剂检测方法为例,探讨色谱柱选择对液相色谱方法测定结果的影响。参照《化妆品安全技术规范》甲基异噻唑啉酮等23个组分的检验方法,在2台不同的高效液相色谱仪上用15款不同品牌、型号的C18色谱柱检测23种防腐剂,计算色谱峰的理论塔板数和分离度,对23种组分的分离效果进行分析,并应用USP (United States Pharmacopeia)数据库和PQRI (Product Quality Research Institute)数据库等2种等效色谱柱选择方法,对不同色谱柱的分离效果及等效性进行评价和预测。实验结果表明,15款色谱柱对23种防腐剂的分离效果差异显著,仅有2款色谱柱可以实现23种组分的完全分离。USP和PQRI数据库中2种等效色谱柱选择方法均无法预测出合适的等效色谱柱,对23种防腐剂的液相色谱分析参考价值均较小。色谱柱是影响23种防腐剂液相色谱法测定结果准确性的关键因素,有关实验室在应用该方法时,应考虑色谱柱选择性差异。化妆品基质复杂,如何在现有研究成果的基础上,开发色谱柱的筛选和预测评价体系,进而指导实际样品的分离是下一步研究的重点、难点。建议有关部门在制修订检测方法时,注重色谱柱的耐用性考察,完善系统适应性指标,细化色谱柱分类和增加描述信息,指导色谱柱的合理选择,从而规避由于色谱柱使用过程中选择依据缺失而导致测定结果不准确的风险。  相似文献   

7.
Capillary columns having a thick liquid phase film and a low phase ratio permit the separation of low molecular mass compounds which would have a very small capacity factor on columns with a classical thin film. At the same time, the increased sample capacity allows conventional hot-wire thermal conductivity detectors to be used with such columns. The analysis of natural and refinery gases, containing both inorganic compounds and light (C1? C7) hydrocarbons, utilizing a combination of hot-wire and flame ionization detectors, is demonstrated.  相似文献   

8.
Summary The influence of temperature and liquid phase film thickness of open-tubular (capillary) columns on the retention index values of hydrocarbons on methylsilicone liquid phases is discussed. Data obtained on methylsilicones and squalane are compared. Retention index values of 43 hydrocarbons between 40 and 70 °C on OV-101 liquid phase are listed.  相似文献   

9.
Analytical high-performance liquid chromatographic enantioseparation of 1-(4-chlorobenzhydryl) piperazine benzamide derivatives was accomplished on different chiral stationary phases. The enantiomers of the compounds were resolved by normal-phase chromatography on silica-based amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD-H), cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD-H) and cellulose tris(4-methylbenzoate) (Chiralcel OJ) columns with mobile phases consisting of mixtures of n-hexane and ethanol in different proportions (90: 10, 80: 20). The mobile phase and the chiral stationary phase were varied to achieve the best resolution. The effect of the concentration of ethanol in the mobile phase was studied. The resolution obtained on the three columns was significant.  相似文献   

10.
陈吉平  张乐沣  田玉增 《色谱》1998,16(1):6-12
以PEG20M为代表研究了石英毛细管柱气液色谱保留过程,提出了利用毛细管柱测定分配和吸附常数的公式,并测定了9个温度下的分配和吸附常数。计算了80℃和120℃下4支不同液膜厚度柱上吸附对保留的贡献。结果表明,在薄液膜的柱子上界面吸附对保留具有重要贡献;温度升高可以降低弱极性化合物(如正构烷烃和饱和醚)吸附对保留的贡献,但对其它化合物影响不明显。验证了正构烷烃、2-酮系列和正构伯醇的吸附常数的碳数规律。  相似文献   

11.
A new aqueous two phase liquid system (ATPS) based on the ionic liquid 1-butyl-3-methyl imidazolium chloride (BMIM Cl), potassium dibasic phosphate (K(2)HPO(4)) and water was recently proposed in the literature. The full phase diagram of this ATPS was prepared and some tie lines were fully determined. It was compared to classical ATPSs based on polyethylene glycol with an average molecular mass of 1000 (PEG 1000) and 10,000 (PEG 10000) and K(2)HPO(4). Two countercurrent chromatography (CCC) columns, a hydrostatic Sanki and a J type hydrodynamic CCC columns were used to test the liquid phase retention of these ATPSs in all possible configurations. It was found that the BMIM Cl ATPS liquid phases were much easier to retain in the two CCC columns than the PEG 1000 ATPS phases. Using protein and alcohol solutes, it was established that the BMIM Cl ATPS has a polarity completely different from that of the PEG 1000 ATPS. For example, ovalbumin partitions equally between the two phases of the PEG 1000 ATPS (K(D)=1.4) when it is completely located in the BMIM Cl upper phase of the ionic liquid ATPS (K(D)=180). The discrimination factor of the ionic liquid system and its intrinsic hydrophobicity were respectively found three times higher and ten times lower than the respective values of the PEG 1000 ATPS.  相似文献   

12.
Natural vitamin E is composed of eight different vitamers (alpha-, beta-, gamma- and delta-tocopherols and alpha-, beta-, gamma- and delta-tocotrienols). As these eight vitamers have different antioxidant and biological activities, it is necessary to have quantitative data on each substance separately. The aim of this study was to find universal HPLC columns for the separation of all eight components and to test if a few columns of the same material (different batches) will give reproducible results. Normal-phase HPLC separations of vitamin E compounds in a prepared mixture (containing oat extracts, palm oil and tocopherol standards) were tried on six silica, three amino and one diol columns. As shown by calculations of retention factors (k), separation factors (alpha), numbers of theoretical plates (N) and resolutions (Rs), the best separations were obtained on three silica columns and two amino columns using 4 or 5% dioxane in hexane as the mobile phase as well as on a diol column using 4% tert.-butyl methyl ether in hexane as the mobile phase.  相似文献   

13.
以腈菌唑为模板分子,采用原位分子印迹技术,制备具有特定识别性能的连续棒状分子印迹聚合物。考察了流动相中酸量对分离的影响,研究了几种结构类似物在所得分子印迹柱上的保留特性。结果表明,这种棒状分子印迹聚合物比相应的空白聚合物有高的识别性能和选择性。  相似文献   

14.
Macroporous polymer based on polydivinylbenzene was used for the preparation of monolithic capillary columns with the diameter from 0.01 to 0.53 mm for separations by gas and liquid chromatography. The separation properties of the columns were studied by analysis of model systems of aromatic (in liquid chromatography) and light (in gas chromatography) hydrocarbons. The permeability was determined and the C parameter of the Van-Deemter equation was found for each column. The permeability of the majority of columns determined by gas chromatography is independent of the column diameter. The permeability of the same columns in liquid chromatography is also almost constant for the columns 0.53–0.1 mm in diameter; however, the permeability decreases sharply on going to columns of smaller diameter. In gas chromatography the value of the C parameter reflecting the effect of the mass transfer of the sorbate between the mobile and stationary phases on the smearing of a chromatographic peak in the column approximately the same for all columns. In liquid chromatography the value of the C coefficient in the Van-Deemter equation for the same capillary columns changes with a change in the column diameter and reaches a minimum for the columns 0.1 mm in diameter. The differences observed for the characteristics of the columns in gas and liquid chromatography are due to different structures of the macroporous monolith formed in columns of different diameter and to the effect of solvation of the monolith by the mobile phase under the conditions of liquid chromatography.  相似文献   

15.
Electrostatic field induced instability, morphology, and patterning of a thin liquid film confined between two electrodes with an air gap are studied on the basis of nonlinear 3D simulations, both for spatially homogeneous and heterogeneous fields. In addition to the spinodal flow resulting from the variation of field because of local thickness changes, a heterogeneous imposed field also moves the liquid from the regions of low field to high field, thus allowing a more precise control of pattern. Hexagonal packing of liquid columns is observed for a spatially homogeneous electric field, which is in accord with the e-field experiments on thin polymer films (Schaffer et al. Nature 2000, 403, 874). For a large liquid volume fraction in the gap, varphi > or = 0.75, the coalescence of columns causes a phase inversion, leading to the formation of air columns or cylindrical holes trapped in the liquid matrix (air-in-liquid dispersion). Locally ordered aligned patterns are formed by imposing a spatial variation of the electrostatic field by using a topographically patterned electrode. For example, multiple rows/lines of liquid columns are formed near the edge of a step-like heterogeneity of the electrode and annular rings of ordered columns or concentric ripples are formed around a heterogeneous circular patch. Simulations predict that the electrode pattern is replicated in the film only when the pattern periodicity, L(p), exceeds the instability length scale on the basis of the minimum interelectrode separation distance, L(p) > or = lambda(m)-d(min). Thus, the formation of secondary structures can be suppressed by employing an electrode with deep grooves and stronger field gradients, which produces almost ideal templating. The number density of the electric field induced patterns can be altered by tuning the mean film thickness (or the volume fraction of liquid in the gap), periodicity and depth (amplitude) of the grooves on the top electrode, and the applied voltage. The implications are in electrostatic lithography, pattern replication in soft materials, and the design and interpretation of thin film experiments involving electric fields.  相似文献   

16.
To purify the tetrachlorobenzo-p-dioxins synthesized for chemical and biological reference standards, reversed-phase liquid chromatography on pyrenylethyl- and octadecylsilylated stationary phase (PYE and C18) columns was employed with 100% methanol. The pyrenylethyl phase satisfactorily separated isomers resulting from mixtures of reaction products which had not been adequately separated with conventional C18 or silica gel. The use of a single chromatographic mode, liquid chromatography, and a single mobile phase with columns of distinctly different properties, C18 and PYE, separates 20 of the 22 isomers from each other and from the 1246/1249 pair. (The observed properties of the two columns afford insight into steric and polarizability differences among isomers.)  相似文献   

17.
L. S. Ettre 《Chromatographia》1983,17(10):553-559
The influence of the liquid phase film thickness in open-tubular (capillary) columns on the individual resistance-to-mass-transfer terms and on the overall column efficiency is examined from the theoretical point of view. Methods for the calculation of the diffusion coefficients are discussed.  相似文献   

18.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

19.
To avoid the limitation of the widely used prediction methods of soil organic carbon partition coefficients (KOC) from hydrophobic parameters, e.g., the n-octanol/water partition coefficients (KOW) and the reversed phase high performance liquid chromatographic (RP-HPLC) retention factors, the soil column liquid chromatographic (SCLC) method was developed for KOC prediction. The real soils were used as the packing materials of RP-HPLC columns, and the correlations between the retention factors of organic compounds on soil columns (ksoil) and KOC measured by batch equilibrium method were studied. Good correlations were achieved between ksoil and KOC for three types of soils with different properties. All the square of the correlation coefficients (R2) of the linear regression between log ksoil and log KOC were higher than 0.89 with standard deviations of less than 0.21. In addition, the prediction of KOC from KOW and the RP-HPLC retention factors on cyanopropyl (CN) stationary phase (kCN) was comparatively evaluated for the three types of soils. The results show that the prediction of KOC from kCN and KOW is only applicable to some specific types of soils. The results obtained in the present study proved that the SCLC method is appropriate for the KOC prediction for different types of soils, however the applicability of using hydrophobic parameters to predict KOC largely depends on the properties of soil concerned.  相似文献   

20.
Summary Column characteristics affecting the chromatographic behavior of glass and siliceous glass (fused silica) capillary columns include the dimensional uniformity of the column, the physical and chemical characteristics of the column wall and the characteristics of the liquid phase. In the case of the coated column the uniformity and thickness of the liquid phase film are the most important criteria affecting column reproducibility. The paper discusses these factors and their influence on column performance.Presented in part at the Symposium on Standardized Materials for Chromatography, 181 st National American Chemical Society Meeting, Atlanta, Georgia, March 29–April 3, 1981.  相似文献   