1.
肖婷婷  诸寅  蔡强  张永明 《分析测试学报》2015,34(10):1142-1146
建立了一种在线中空纤维膜液相微萃取/高效液相色谱联用技术测定3种痕量芳香胺(邻甲苯胺、3,3'-二甲基联苯胺、2-萘胺)的新方法,以顺序注射仪将中空纤维膜液相微萃取装置和高效液相色谱仪连接搭建在线检测装置,利用此装置优化了萃取溶剂、供体相、接收相、盐效应、搅拌速度、萃取时间等前处理条件。结果表明,以正辛醇为萃取溶剂,0.1 mol·L-1Na OH与300 mg·L-1的Na Cl溶液为供体相,0.1 mol·L-1HCl溶液为接收相,搅拌速度为400 r·min-1,萃取40 min后,3种芳香胺的富集倍数可达48~96倍。该方法对3种痕量芳香胺的线性范围为0.01~0.25 mg·L-1,相关系数(r)不小于0.998 4,检出限为0.3~2.2μg·L-1,相对标准偏差(RSD,n=10)为3.1%~4.0%,用于印染废水中3种芳香胺的分析,回收率为98.0%~102.0%。该方法操作简单,有机溶剂用量少,富集率较高,可用于痕量芳香胺类物质的快速分析。  相似文献   

2.
采用纤维膜三相液相微萃取(HF-LLLME)技术,对汗液基质中的苯胺、邻甲苯胺、对氯苯胺、对硝基苯胺进行了分离富集。以正辛醇为有机相,在供体相pH为9.0,NaCl质量浓度为200g/L,接收相pH为1.0,萃取时间为60min的条件下,4种芳香胺的富集倍数为410~1250倍。将接收相直接进行毛细管电泳(CE)测定,样品相中4种芳香胺的质量浓度在10~100μg/L范围内与电泳峰面积呈良好线性,相关系数均大于0.992,4种芳香胺的检出限为1~10μg/L。运用该法对偶氮染料汗液环境下光致降解过程中产生的苯胺进行测定,回收率为91%~93%,结果满意。  相似文献   

3.
基于中空纤维液相微萃取技术,建立了绿豆芽中吲哚类植物生长素的荧光检测方法。通过L9(34)正交实验,对中空纤维液相微萃取条件进行优化,得到的优化条件为:样品溶液的p H值调为4.0,萃取溶剂为正辛醇,接受相为p H 12.0的Na OH,搅拌速度为1 000 r/min,萃取时间为60 min。在最优萃取条件下,吲哚类植物生长素的富集倍数可达92倍。供体相中吲哚类植物生长素的质量浓度在1.71~50.0 mg/L范围内呈良好的线性关系,相关系数为0.997 9,检出限(S/N=3)为0.57 mg/L,样品的加标回收率为88.6%~100.7%,相对标准偏差(RSD)不大于4.8%。该方法操作简单,环境友好,可用于绿豆芽中吲哚类植物生长素含量的准确快速测定。  相似文献   

4.
采用2-乙基己基膦酸单-2-乙基己基酯(HEHEHP)-正庚烷为萃取剂,盐酸为反萃取剂,中空纤维膜作支撑膜,研究中空纤维分散液膜技术富集稀土镱(Yb~(3+))离子。考察了体系物性:反萃分散相中反萃剂浓度、萃取剂浓度、萃取剂与反萃剂体积比、料液相p H值、稀土离子浓度;流体流动状态:反萃分散相与料液相流速变化等因素对富集稀土离子的影响。中空纤维分散液膜富集Yb~(3+)的最佳条件为:萃取剂浓度为0.25 mol/L,反萃取剂HCl浓度为4.00 mol/L,萃取剂与反萃剂体积比为10∶40,料液相p H=2.80,稀土离子浓度为0.025 mol/L。反萃分散相体积流量和料液相体积流量较小时,萃取率随流量的增加呈现逐渐增大的趋势。若两相体积流量过大,反萃过程进行不完全,萃取率反而下降。研究结果表明,中空纤维分散液膜技术可实现稀土离子的有效富集。  相似文献   

5.
建立了三相中空纤维膜微萃取/超高效液相色谱(HF-LPME/UHPLC)方法,用于大肠杆菌中8种氨基酸的测定。设计了三相中空纤维膜微萃取系统,优化了HF-LPME最佳萃取条件:液膜为正辛醇,接收相Na OH的浓度为0.30 mol/L,给出相样品溶液中盐酸浓度为5.0 mmol/L,Na Cl质量浓度为200 g/L,萃取温度为25℃,搅拌速度为500 r/min,萃取时间为4 h。8种氨基酸经衍生并萃取后进行色谱分析,在5 min内达基线分离,其峰面积与浓度在0.20~4.9×10~3μmol/L范围内呈良好的线性关系,相关系数r2均大于0.999,富集倍数为110~290倍,检出限为0.08~0.35μmol/L。在10μmol/L加标水平下,大肠杆菌样品的平均回收率为88.7%~103.1%,相对标准偏差(n=5)为3.2%~4.3%。该方法灵敏度高、重复性好,可用于细菌中氨基酸的检测。  相似文献   

6.
建立了中空纤维液-液-液微萃取高效液相色谱对人尿液中的麻黄碱和伪麻黄碱进行纯化、分离、富集以及测定的方法。采用中空纤维三相微萃取装置,考察了影响萃取的因素,确定了萃取条件:中空纤维壁上的有机相为正辛醇,以50μL盐酸溶液(pH 2.0)为接受相,在室温下萃取60 min。该条件下麻黄碱和伪麻黄碱的富集倍数分别为180倍和220倍,两者的线性范围分别为0.01~5 mg/L和0.005~0.75 mg/L,相关系数(r)分别为0.998 2、0.997 8,定量下限分别为0.01、0.005 mg/L。该方法使用极少量的有机溶剂,便可有效地对尿样中麻黄碱和伪麻黄碱进行纯化、分离和富集,萃取效率高,可用于尿液中麻黄碱和伪麻黄碱的同时测定。  相似文献   

7.
讨论了以中空纤维为载体的碳纳米管/正辛醇固-液协同微萃取机理,建立了中空纤维碳纳米管/正辛醇固-液协同微萃取-高效液相色谱法同时测定复杂样品中微量咖啡酸、阿魏酸和肉桂酸含量的方法.以2.5 cm长的聚偏氟乙烯中空纤维为碳纳米管正辛醇分散液载体,供相为分析物的HCl(pH 2.1)溶液,接受相为pH 12.7的NaOH溶液,在35℃下,搅拌萃取60 min,萃取液进行高效液相色谱紫外检测.在优化的实验条件下,分析物的线性范围均在0.05~50 μg/L,r>0.9990 (n=5);检出限均为0.015μg/L;日内与日间精密度均小于9.8%(n=9),平均回收率为93.8%~115.2%;富集倍数分别为514,942和1084倍.在以中空纤维为支持体的碳纳米管/正辛醇微萃取中,碳纳米管/正辛醇分散液嵌入中空纤维管壁上的微孔中形成了碳纳米管/正辛醇固-液微萃取单元束,对苯丙烯酸类化合物起到协同萃取作用.  相似文献   

8.
建立了三相中空纤维膜液相微萃取-高效液相色谱(HF-LPME-HPLC)方法,用于分析测定水中痕量双酚A的含量.设计了三相中空纤维膜液相微萃取系统,优化的HP-LPME最佳萃取条件为:萃取剂为正辛醇,接受相NaOH浓度为0.09 mol/L,样品溶液pH=4.0,NaC1加入量为30 g/L,搅拌速度为900 r/min,萃取时间为60 min.萃取后取20 μL接受相进行色谱分析.在最佳萃取条件下,方法的线性范围为0.5~200 μg/L(r> 0.999),检出限(信噪比为3)为0.2 μg/L;富集因子为241;方法RSD<3.2% (n=3).在实际环境水样中添加5,20和50μg/L的双酚A标准物质,加标平均回收率为92.8%~101.9%.表明本方法可用于水中痕量双酚A的快速准确测定.  相似文献   

9.
建立中空纤维液相微萃取-高效液相色谱法(HF-LPME-HPLC)用于监测药品生产企业排放废水中痕量的β-受体阻断剂。采用HF-LPME技术对废水中痕量的β-受体阻断剂萃取、纯化和富集,以正辛醇为萃取溶剂、萃取时间为60 min、转速为800 r/min、温度60℃。在优化的萃取条件下,美托洛尔,氧烯洛尔,贝凡洛尔的富集倍数分别为139,195,280倍,最低检测限(S/N=3)为0.064,0.048,0.032 ng/m L,日内精密度(RSD)为1.7%,1.2%,1.0%。3种药物在浓度测定范围内线性良好。  相似文献   

10.
陈璇  白小红  王晓  王婧  卜玮 《色谱》2010,28(12):1144-1149
利用中空纤维液相微萃取方法(HF-LPME)分析麻黄碱和伪麻黄碱在不同基质中的优势构象,阐明了麻黄碱和伪麻黄碱的萃取机理;结合高效液相色谱(HPLC)建立了微量麻黄碱和伪麻黄碱的分离测定方法。以聚偏氟乙烯中空纤维为有机溶剂载体,正己醇为萃取溶剂,麻黄碱和伪麻黄碱的NaOH(5 mol/L)溶液为样品相,0.01 mol/L H2SO4溶液为接收相,在1200 r/min转速下萃取35 min,收集萃取液直接进行HPLC分析。麻黄碱和伪麻黄碱在水溶液中的线性范围为5~100 μg/L,检出限分别为1.9 μg/L和1.2 μg/L,富集倍数分别为38和61倍,平均回收率分别为100.6%±1.2%和103.2%±3.5%;在鼠尿液中的线性范围为100~5×104 μg/L,检出限分别为30 μg/L和42 μg/L,富集倍数分别为20和17倍,平均回收率分别为108.4%±4.4%和106.1%±5.4%。研究表明该方法操作简单,选择性高,适用于微量麻黄碱的含量测定和分析。  相似文献   

11.
The room temperature ionic liquid (IL) 1-butyl-3-methylimidazolium bis-(trifluorometanesulfonyl)imide BMIm[NTf?] was used as a novel medium for improvement of separation and quantization of 16 aromatic amines typically present as contaminants in consumer products and detected by HPLC coupled to an electrochemical detector. The aromatic amines, namely 4,4'-diaminodiphenylmethane, 4-chloroaniline, 2-methoxy-5-methyl-aniline, 3,3'-dimethylbenzidine, 2,4-diaminotoluidine, 2-chloro-4-nitroaniline, 4,4'-oxydianiline, aniline, 3,3'-ichlorobenzidine, benzidine, 4-aminobiphenyl, o-dianisidine, o-anisidine, o-toluidine, 4,4'-methylene-bis-2-chloroaniline and 2-naphthylamine are oxidized in methanol/BMIm[NTf?] at a potential around +0.68V to +0.93V vs. Ag/AgCl at a glassy carbon electrode, which is the base for their determination by HPLC/ED. Using the optimized conditions of methanol/BMIm[NTf?] 70:30 (v/v) as mobile phase, flow-rate of 0.8 mL·min?1, column CLC-ODS, Eap = +1.0 V and T = 40 °C analytical curves were constructed for each of the tested amines. Good linearity was obtained in the concentration range of 1.09 mg·L?1 to 217 mg·L?1, with excellent correlation coefficients. The limits of detection reached 0.021 mg·L?1 to 0.246 mg·L?1 and good relative standard deviations (RSD, n = 3) were obtained from the measurements. Satisfactory recovery for each aromatic amine was achieved, ranging from 95 to 103%. The developed method was successfully applied to determine six aromatic amines present as contaminants in commercial hair dye samples.  相似文献   

12.
Zhang J  Wu X  Zhang W  Xu L  Chen G 《Electrophoresis》2008,29(4):796-802
A simple and rapid sweeping method for the online improvement of detection limit of some aromatic amines has been developed in this work. The optimum sweeping and separation conditions for 4-methylaniline, 3,4-dichloroaniline, 4-chloroaniline, and 4-aminophenyl were investigated in detail. Under the optimum conditions, the detection limits of these four aromatic amines ranged from 5.4 x 10(-10) to 4.6 x 10(-8)mol/L (S/N = 3), which was about 80-1090-folds lower than those of conventional sample injections. Linear response range were in the range of 2.5 x 10(-8)-2.0 x 10(-6)mol/L with the correlation coefficient between 0.9965 and 0.9994. Baseline separation was achieved within 10 min. After validation, the developed method was applied to determine 4-methylaniline, 3,4-dichloroaniline, 4-chloroaniline, and 4-aminophenyl in river water sample with average recoveries of 79.6-88.7%.  相似文献   

13.
张朝辉  康绍英  许敏洁  马铭  陈波  姚守拙 《色谱》2005,23(4):358-361
建立了液-液-液微萃取与高效液相色谱联用同时测定血浆中西地那非和伐地那非的方法。考察了萃取溶剂、溶剂体积、接受相液滴大小、搅拌速度和萃取时间等因素对富集因子的影响,得到了萃取溶剂为300 μL 甲苯、接受相为2 μL 0.2 mol/L HCl、搅拌速度为600 r/min和萃取时间为40 min的最佳实验条件。在该条件下,获得了较高的富集因子。两种组分的线性范围均为5 μg/L~1.0 mg/L,加标回收率高于87%,其相对标准偏差小于5%。以信噪比为3计,西地那非的检测限为1 μg/L,伐地那非为0.5 μg/L。该方法能有效地去除复杂基体的干扰,有机溶剂消耗少,萃取效率高,是一种有效的、灵敏的样品前处理方法,适用于血浆中微量西地那非和伐地那非的测定。  相似文献   

14.
A novel method of microemulsion electrokinetic chromatography (MEEKC) coupled with hollow fiber-liquid phase microextraction (HF-LPME) was developed for determination of six aromatic amines including 4-methylaniline, 3-nitroaniline, 2,4-dimethylaniline, 4-chloroaniline, 3,4-dichloraniline and 4-aminobiphenyl. Baseline separation of six aromatic amines was achieved within 8 min by using the microemulsion buffer containing a 10 mM borate buffer at pH 9.0, 0.8% (v/v) ethyl acetate as oil droplets, 60 mM sodium cholate as surfactant, 5.0% (v/v) 1-butanol as co-surfactant. The influence factors relevant to the HF-LPME process were systemically investigated. The obtained enrichment factors were ranged between 70 and 157 in a 30 min extraction time, and the limits of detection ranged between 0.0021 and 0.0048 μg/mL. This purposed method was successfully applied for the analysis of aromatic amines in water sample and the recoveries were ranged from 87.2% to 99.8%.  相似文献   

15.
张成功  赵倩  陈波  马铭 《色谱》2007,25(5):641-645
建立了液-液-液三相液相微萃取与高效液相色谱联用技术测定尿样中的安非他明和氯胺酮的方法。考察了萃取溶剂、料液相pH值、搅拌速度、萃取时间和接受相HCl浓度等因素对富集因子的影响,得到了萃取溶剂为300 μL甲苯,料液相pH值为11,接受相为1.0 μL 0.1 mol/L HCl,搅拌速度为600 r/min,萃取时间为50 min的最佳实验条件。在该条件下,获得了较高的富集因子;方法的线性范围为安非他明0.01~10 μg/mL,氯胺酮0.01~5 μg/mL,相对标准偏差均小于2%,检测限均为5 ng/mL (S/N=3)。建立的三相液相微萃取方法能有效地去除复杂基体的干扰,有机溶剂消耗少,萃取效率高,是一种有效、灵敏的样品前处理方法,适合于尿样中安非他明和氯胺酮的测定。  相似文献   

16.
叶曦雯  何静  李莹  牛增元  张甜甜  罗忻  邹立  连素梅 《色谱》2020,38(2):255-263
建立了液液萃取-分散液液微萃取-气相色谱-质谱联用技术测定纺织废水中痕量偶氮染料的方法。废水中的偶氮染料在碱性条件下经连二亚硫酸钠还原成芳香胺后,先用叔丁基甲醚液液萃取、盐酸反萃进行预浓缩及净化;再以乙腈-氯苯体系进行分散液液微萃取,气相色谱-质谱测定。对前处理条件进行了优化,考察了酸碱度及盐效应对芳香胺萃取效率的影响,结果表明:液液萃取过程中加入30 g NaCl,分散液液微萃取过程中加入1 mL 5 mol/L的NaOH调节体系至碱性才能达到较好的萃取效率。在优化的实验条件下,21种目标物均呈现良好的线性关系,其中13种芳香胺的线性范围为0.05~10 μg/L,7种芳香胺的线性范围为0.05~5 μg/L,2,4-二氨基苯甲醚的线性范围为20~100 μg/L,相关系数为0.996~0.999。20种芳香胺的检出限可达0.05 μg/L,2,4-二氨基苯甲醚检出限为20 μg/L。印染、机织、印花等实际废水加标试验表明,方法的回收率为75.6%~115.1%。该方法富集倍数高,检出限低,适用于纺织废水中痕量禁用偶氮染料的检测。  相似文献   

17.
Zhou X  Wang Y  Chen L  Kang X 《色谱》2011,29(11):1107-1111
基于纳米纤维的富集作用,建立了血浆中5-羟色胺(5-HT)的柱前衍生高效液相色谱-电化学检测(HPLC-ECD)分析方法.用10%(v/v)高氯酸溶液沉淀血浆蛋白,离心后取上清液,用0.1 mol/L 的四苯硼酸钠溶液调节pH值至8.5,加入衍生剂邻苯二甲醛溶液于30 ℃衍生4 min,经纳米纤维固相萃取柱净化富集后,...  相似文献   

18.
陈娟  王超  王星  马强  李楠 《色谱》2007,25(6):867-870
建立了用高效液相色谱-二极管阵列检测器(HPLC-PDA)同时检测9种染料及中间体的系统方法。首先采用超声提取的方法处理样品,对提取溶剂和提取时间进行了选择,确定用甲醇-0.01 mol/L 乙酸铵(体积比为2∶1)作提取溶剂,超声提取20 min。然后,采用C18柱,以甲醇-0.01 mol/L乙酸铵(pH 6.2)为流动相梯度洗脱,用PDA检测。以保留时间定性,并以紫外吸收光谱图辅助定性,以外标法定量。定量检测波长为230 nm,15 min内可对9种目标物同时进行测定,且各化合物都达到基线分离(分离度大于1.5)。经测定,该方法的平均回收率(n=8)为81.0%~105.6%,相对标准偏差(RSD)为0.8%~4.9%,检出限(以信噪比为3计)为0.1~2 μg。该方法简单、快速,能有效提取和分离测定化妆品中9种染料及中间体。将该方法用于实际化妆品样品的检测,结果令人满意。  相似文献   

19.
胶束电动毛细管色谱检测鱼肉中的七种生物胺   总被引:4,自引:1,他引:3  
干宁  李天华  王鲁雁  江千里 《色谱》2007,25(6):934-938
建立了一种利用胶束电动毛细管色谱同时检测鱼肉中组胺、腐胺、2-苯乙基胺、尸胺、色胺、亚精胺及精胺7种生物胺的方法。样品经6%过氯酸萃取后,由苯甲酰氯衍生化,以含0.06 mol/L脱氧胆酸钠的0.02 mol/L硼酸(pH 9.2)-甲醇(体积比为95∶5)混合液为电泳介质,电泳电压25 kV,温度25 ℃,检测波长214 nm,在12 min内实现了7种生物胺的完全分离。7种生物胺的浓度与其峰面积在一定的范围呈良好的线性关系,检出限除组胺为15 μg/g外,其余均为5 μg/g。迁移时间和峰面积的日内、日间相对标准偏差均小于5%。该法用于海鱼中7种胺类物质含量的测定,结果令人满意。  相似文献   