首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
This is the second paper in a series of three devoted to the application of scanning tunneling microscopy (STM) to mechanics problems. In this paper, improvements to the digital image correlation method are outlined, a technique that compares digital images of a specimen surface before and after deformation to deduce its two-dimensional surface displacement field and strains. The necessity of using the framework of large deformation theory for accurately addressing rigid body rotations to reduce associated errors in the strain components is pointed out. In addition, the algorithm is extended to compute the three-dimensional surface displacement field from STM data; also, significant improvements are achieved in the rate as well as the robustness of the convergence. For (STM) topographs, the resolution yields 4.8 nm for the in-plane and 1.5 nm for the out-of-plane displacement components spanning an area of 10 m×10m.  相似文献   

2.
Planar digital image correlation has been extended to measure surface deformations of cylindrical specimens without physical contact for high-temperature situations. A single CCD camera acquires the surface image patterns of a section of a specimen in the undeformed and deformed states to determine two-dimensional displacements on a projection plane. Axial, circumferential and shear deformations are determined through curvature transformation on the two-dimensional projection displacement field. The resolution of this technique was determined for a cylinder of 22.23-mm diameter to be 3.5 μm for the axial displacement, 0.05 percent for the axial and shear strains and 0.08 percent for the circumferential strain when correlation computations are carried out over a field of 5 mm×5 mm.  相似文献   

3.
提出了用超声散斑干涉法来测量物体的位移,并且基于数字干涉和相移-频移技术对超 声散斑数字干涉测量法进行了初步的理论推导. 为了验证理论分析的结果,对一铝试件进行 了离面位移和面内位移的试验测量. 试验结果显示理论分析是正确的,在测量位移和变形时 此方法是有效可行的.  相似文献   

4.
Ultra-lightweight spacecraft incorporating “gossamer” structures are extremely compliant, which complicates control, design, and ground testing in full scale. One approach to model the behavior of a full-scale gossamer structure is to construct a small-scale model test article that can be used to verify a corresponding small-scale computer model. Once the predictions of the computer model have been verified by measurement of the physical test article, it can be scaled up to allow computation of the full-scale structure behavior. As model verification requires accurate deflection measurements at multiple points along the surface of the structure, a sensing system that provides full-field data without changing the dynamic response of the structure must be developed. Hence, an optical approach is taken. Since the thin films used in gossamer space structures are typically smooth and featureless, targets must be incorporated into the film surface to enable tracking of both in-plane and out-of-plane displacements. A krypton fluoride excimer laser system was used to etch 35 μm wide linear features approximately 0.1 μm into the surface metallization of both 50.8 μm polyester and 127 μm polyimide films. These optically diffuse surface features, designed mainly to investigate the precision of the laser etching method, were used as targets for ultra-close-range photogrammetry, the method chosen for displacement tracking. A force applied to the surface of the etched mirror (test article) produced in-plane and out-of-plane deformations that were resolved via ultra-close-range photogrammetry. To measure the in-plane tracking resolution, 1.5 and 3.0 mm circular dots were added (using ink) to the surface of the thin film, and some of these targets were tracked as the test article was translated on a precision linear stage. In-plane tracking resolution using ultra-close-range photogrammetry was related to the ground sample distance of the camera, which in this case was 51.25 μm pixel−1 (equal to the ratio of sample dimension to number of pixels in the field of view). Using a manual technique to identify features of the etched pattern for tracking, the mean tracking error was about 13 μm (σ=43 μm). Using an automated, subpixel marking technique to identify the 1.5 mm circular targets, the mean tracking error was 22 μm (σ=13 μm). Neither of these methods achieved the desired 10 μm tracking resolution.  相似文献   

5.
缪泓  张泰华  郇勇  伍小平 《实验力学》2007,22(3):424-428
研制了一套可应用于MEMS器件的微尺度测量系统,可以在受载状态下实时检测MEMS器件的面内位移、离面位移和三维形貌。该系统中,面内位移测量是一个基于白光数字散斑相关方法的显微光学测量系统,与相应的力学加载系统结合,可以得到MEMS器件在受载状态下的实时面内位移;离面位移和三维形貌测量则是一个基于相移显微投影光栅方法的光学测量系统,与相应的力学加载系统结合,可以得到MEMS器件在受载状态下的实时三维形貌和离面位移。最后给出了几个典型的MEMS器件面内位移、离面位移和三维形貌的实测结果。  相似文献   

6.
A three-nested-deformation model is proposed to describe crack-tip fields in rubber-like materials with large deformation.The model is inspired by the distribution of the measured in-plane and out-of-plane deformation.The inplane displacement of crack-tip fields under both Mode I and mixed-mode(Mode I-II) fracture conditions is measured by using the digital Moire’ method.The deformation characteristics and experimental sector division mode are investigated by comparing the measured displacement fields under different fracture modes.The out-of-plane displacement field near the crack tip is measured using the three-dimensional digital speckle correlation method.  相似文献   

7.
A high-magnification moiré interferometer, particularly suitable for near-tip field analysis in cracked materials, is described. It has a submillimeter field of view, a high-resolution image sensor (1.4 million pixels), X-Y-Z translation stage and an optical fiber light delivery system. These features enable the microscope head to observe the crack tip while the specimen is loaded in a standard tensile test machine. Automated fringe pattern analysis, using temporal phase shifting and spatial phase unwrapping, enables thex ory displacement component to be measured and the corresponding in-plane strain component computed. The displacement placement accuracy is better than 40 nm, and the effective strain gage dimension is ∼ 25 μm. Furthermore, the interferometer has a built-in white light microscope that allows the observation of the specimen granular microstructure in exact registration with the displacement field. The interferometer has hence been employed to investigate the near-tip fields of a precracked stainless steel specimen under load. The influence of the grain boundaries on the measured displacement fields was relatively minor. The near-tip strain field shows a significant asymmetrical behavior despite pure mode lloading conditions.  相似文献   

8.
The digital image correlation (DIC) technique is successfully applied across multiple length scales through the generation of a suitable speckle pattern at each size scale. For microscale measurements, a random speckle pattern of paint is created with a fine point airbrush. Nanoscale displacement resolution is achieved with a speckle pattern formed by solution deposition of fluorescent silica nanoparticles. When excited, the particles fluoresce and form a speckle pattern that can be imaged with an optical microscope. Displacements are measured on the surface and on an interior plane of transparent polymer samples with the different speckle patterns. Rigid body translation calibrations and uniaxial tension experiments establish a surface displacement resolution of 1 μm over a 5×6 mm scale field of view for the airbrushed samples and 17 nm over a 100×100 μm scale field of view for samples with the fluorescent nanoparticle speckle. To demonstrate the capabilities of the method, we characterize the internal deformation fields generated around silica microspheres embedded in an elastomer under tensile loading. The DIC technique enables measurement of complex deformation fields with nanoscale precision over relatively large areas, making it of particular relevance to materials that possess multiple length scales.  相似文献   

9.
A simple setup for simultaneous measurement of in-plane and out-of-plane displacement components is demonstrated. Since the in-plane and out-of-plane components are recorded at separate positions, no additional processing of the patterns is required. Suggestions are made for further simplification by proper choice of specimen and reference gratings. Paper was presented at the 1988 SEM Spring Conference on Experimental Mechanics held in Portland, OR on June 5–10.  相似文献   

10.
The “planar” digital image correlation technique needs a single CCD camera to acquire the surface patterns of a zone of a specimen in the underformed and deformed states. With these two images, one can determine in-plane displacement and strain fields. The digital image correlation technique used herein is based on Fast Fourier Transforms, which are very effective in reducing the computation cost. Its performance is assessed and discussed on artificial signals and in a real experimental situation. The technique is utilized to analyze experimental results of a plane shear experiment and validate a damage meso-model describing different degradations in a C/C composite material.  相似文献   

11.
结合数码显微镜的数字散斑相关方法精度分析及应用   总被引:1,自引:0,他引:1  
侯方  雷冬  龚兴龙 《实验力学》2009,24(4):269-275
结合数字散斑相关方法和一种新型的显微镜数码显微镜,提出了一种测量多晶材料晶粒尺度面内变形的新方法,并通过零变形校准实验、重聚焦实验和平移实验等一系列验证实验分析了该方法的精度和实用性.作为应用实例,对一种镍基合金试件进行了单向拉伸和疲劳实验,得到了晶粒尺度下具有较大应变梯度的应变分布图像.结果表明,该方法能够得到精确的位移测量数据,是一种理想的测量晶粒尺度变形的光测方法.  相似文献   

12.
It is challenging to measure accurately and with high spatial resolution the local thermal strains in heterogeneous microstructures due of the complex nature of the thermal deformations and local boundary conditions. In the enclosed study, a digital image correlation (DIC) based, thermal strain mapping technique is described that is able to probe thermal deformations with sub-micron spatial resolution and sub-nanometer displacement accuracy for both homogeneous and heterogeneous materials, including cross-sections of IC packages. The full-field thermal deformation maps of different materials within a nanostructured IC chip cross-section are established from room temperature up to 160 °C, uncovering the heterogeneous nature of the specimen while accurately measuring the highly non-uniform displacement and strain fields across the multiple material constituents. As described in this work, the DIC-enabled technique is capable of high resolution mapping of local thermo-mechanical deformations in heterogeneous materials, providing a methodology that can improve our understanding of complex material systems under controlled thermal-environmental conditions.  相似文献   

13.
俞立平  潘兵 《实验力学》2017,(5):687-698
介绍了一种基于单个彩色相机的新型全靶面、单相机三维数字图像相关(3D-DIC)方法。借助于设计巧妙的颜色分光光路,被测物体表面图像可以通过两条不同的光路达到相机靶面,采集的标定靶和实验件表面的彩色图像可以分离得到蓝色和红色子图像。通过使用3D-DIC分析标定靶和实验件表面分离后的蓝色和红色子图像,可以获得物体表面的三维形貌和变形。形貌测量、面内和离面平移、以及静动态三维变形实验验证了该单彩色相机3D-DIC方法的有效性和测量精准度。由于可避免双相机同步,且能实现无分辨率损失的全靶面三维形貌和变形测量,本文方法在需要实现瞬态位移和变形测量的爆炸、冲击、振动等领域中具有广阔重要的应用前景。  相似文献   

14.
Plastic surface strain mapping of bent sheets by image correlation   总被引:2,自引:0,他引:2  
A technique using a single CCD camera, a precision rotation/translation stage, a telecentric zoom lens, and digital image correlation software is described for measuring surface profiles and surface plastic strain distributions of a bent thin sheet. The measurement principles, based on both parallel and pinhole perspective projections, are outlined and the relevant mathematical equations for computing the profiles and displacement fields on a curved surface are presented. The typical optical setup as well as the experimental measurement and digital image correlation analysis procedure are described. The maximum errors in the in-plane and out-of-plane coordinates or displacements are about ±5 and ±25 μm, respectively, and the maximum errors in surface strain mapping are about 0.1% or less based on a series of evaluation tests on flat and curved sample surfaces over a physical field of view of 15.2 × 11.4 mm2. As an application example, the shape and surface plastic strain distribution example, the shape and surface plastic strain distributions around a bent apex of a flat 2 mm thick automotive aluminum AA5182-O sheet, which underwent a 90° bend with three bend ratios of 2t, 1t, and 0.6t, are determined using the proposed technique.  相似文献   

15.
This is the third and last paper is a sequence devoted to an experimental investigation of deformation mechanisms at the submicron scale through the use of a specially designed scanning tunneling microscope. Its application, when used jointly with digital image correlation, as a tool for strain and deformation determinations is explored by way of two demonstrations. First, deformations in a uniaxially stressed, unplasticized (poly)vinylchloride sample are analyzed to yield the three-dimensional surface displacement field over a 10 m×10m area. Homogeneous deformations occur at the micrometer and large size scales. However, at the 100-nm scale, inhomogeneous deformations embedded in a homogeneous deformation field appear. The second example addresses the deformation field in the vicinity of an interface between a carbon fiber and the surrounding matrix under shear stresses along the fiber. This loading leads to shearing a sheath from the carbon fiber that is about half a micron thick.  相似文献   

16.
A novel nondestructive testing (NDT) method is reported in which temporal evolution of the speckles in speckle interferometry is used to measure large object deformations. The basic principle of the method is that continuous object movement introduces fluctuations in the phase of the speckle and is recorded as intensity modulation. Acquiring a large number of frames of the object motion, the phase data for the whole object deformation are then retrieved by the Fourier transformation technique. The method is capable of measuring more than 100 μm in-plane and out-of-plane deformation with speckle interferometry and more than 500 μm for speckle shearing interferometry. The authors discuss the NDT results obtained with the three methods and make some relative comparisons of each.  相似文献   

17.
This paper presents the test technique about measurement of electrical resistance changes of thin films during tensile testing. In this work, we used a real-time digital image correlation strain measurement system coupled with micro-tensile testing unit and voltage/current sourcemeter. This system has the advantage of real time displacement monitoring with a resolution of 50 nm during the micro-tensile testing, with the ability to measure the variation in electrical resistance of the specimen at the same time. We obtained the complete testing data for the stress–strain curve and associated electrical resistance-strain curve for 1 and 2 μm-thick freestanding gold films. Young’s modulus was about 61~69 GPa and 0.2% offset yield strength was about 361~402 MPa. In case of the electrical resistance, rapid change was observed under the elastic regime, while less obvious under the plastic regime. We also conducted finite element analysis, and this result implied that the electrical resistivity would not be constant during micro-tensile testing.  相似文献   

18.
In-plane surface displacements, when measured with 2D Digital Image Correlation (2D-DIC), are very sensitive to out-of-plane displacement components. Any out-of-plane motion of the surface can pollute the measured field by introducing artificial displacements. These displacements are difficult to separate from the underlying response of the surface and thereby limit the application of 2D-DIC in inverse problems where the test specimen has significant motion in the out-of-plane direction. In the context of inverse problems, we propose to partially relax this condition of no out-of-plane motion in 2D-DIC. With this approach, only the out-of-plane rigid-body motion of the specimen surface, which is initially in-plane, needs to be avoided while the requirement of surface deformations to be primarily in-plane is essentially waived. Compensation, based on the pinhole camera model, for out-of-plane displacements of the surface in response to applied load is included within the error function of the minimization problem. The improvements in material parameter estimation, obtained by using the proposed compensation strategy, are demonstrated by an example. The proposed technique makes it possible to utilize 2D-DIC with a simple conventional lens for an increased number of inverse problems; and in the process avoiding the computational and experimental difficulties associated with 3D measurement methods as well as the high cost and magnification limitations of a telecentric lens.  相似文献   

19.
In practice, out-of-plane motions usually are not avoidable during experiments. Since 2D–DIC measurements are vulnerable to parasitic deformations due to out-of-plane specimen motions, three-dimensional digital image correlation (StereoDIC or 3D–DIC) oftentimes is employed. The StereoDIC method is known to be capable of accurate deformation measurements for specimens subjected to general three-dimensional motions, including out-of-plane rotations and displacements. As a result, there has been limited study of the deformation measurements obtained when using StereoDIC to measure the displacement and strain fields for a specimen subjected only to out-of-plane rotation. To assess the accuracy of strain measurements obtained using stereovision systems and StereoDIC when a specimen undergoes appreciable out of plane rotation, rigid body out-of-plane rotation experiments are performed in the range ?400?≤?θ?≤?400 using a two-camera stereovision system. Results indicate that (a) for what would normally be considered “small angle” calibration processes, the measured normal strain in the foreshortened specimen direction due to specimen rotation increases in a non-linear manner with rotation angle, with measurement errors exceeding ±1400με and (b) for what would normally be considered “large angle” calibration processes, the magnitude of the errors in the strain are reduced to ±300με. To theoretically assess the effect of calibration parameters on the measurements, two separate analyses are performed. First, theoretical strains due to out-of-plane rigid body rotation are determined using a pinhole camera model to project a series of three-dimensional object points into the image plane using large angle calibration parameters and then re-project the corresponding sensor plane coordinates back into the plane using small angle calibration parameters. Secondly, the entire imaging process is also simulated in order to remove experimental error sources and to further validate the theory. Results from both approaches confirmed the same strain error trends as the experimental strain measurements, providing confidence that the source of the errors is the calibration process. Finally, variance based sensitivity analyses show that inaccuracy in the calibrated stereo angle parameter is the most significant factor affecting the accuracy of the measured strain.  相似文献   

20.
利用数字图像相关方法测量表面带孔洞、裂纹、缺口等缺陷试样的全场变形是许多实际测量任务中经常遇到的问题。就此问题,本文阐述了一种先对要避免计算的缺陷区域进行标记,在随后进行的相关计算中直接避免这些标记区域的方法。在已计算得到全场位移的情况下,文中提出了基于局部位移场最小二乘拟合的方法来计算区域边界、孔洞、裂纹或缺口附近等区域应变。最后对单侧边带半圆缺口试样的单向疲劳拉伸实验的计算结果充分显示本文方法的有效性和可靠性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号