共查询到18条相似文献,搜索用时 125 毫秒
1.
2.
3.
建立了双级压缩空气源热泵的动态仿真模型。对压缩机、膨胀阀以及换热器分别建立部件模型。由于压缩机和膨胀阀的热惯性较小,所以采用稳态模型来描述。蒸发器和冷凝器部件建立动态模型时,针对制冷剂侧、管壁、以及载冷剂侧三个控制容积,分别建立控制方程。最后,通过参数耦合,建立系统仿真模型。 相似文献
4.
5.
6.
《低温与超导》2016,(11)
利用Fluent建立土壤源热泵空调系统仿真模型,通过模拟结果与热响应测试所得结果的比较验证了模型的准确性。该模型耦合了土壤源热泵空调系统三大组成部分:负荷末端、热泵机组以及地埋管换热器。在此前提下,研究土壤源热泵空调系统中不同地下水流速工况下热泵机组COP的变化情况。结果表明,在常见的地下水流速0m/a至300m/a范围内,地下水流速越大,热泵机组COP越大,其中夏季制冷期间,当地下水流速从0分别增加到60m/a,100m/a,150m/a,200m/a,250m/a,300m/a时,机组COP分别增加11.54%,16.04%,19.91%,23.17%,25.50%,27.14%,从而减小了机组运行能耗。 相似文献
7.
《工程热物理学报》2021,42(8):2048-2059
针对太阳能供暖系统占地面积大、高寒地区供暖效果不稳定情况,本文利用TRNSYS搭建实验系统仿真模型,以空气源热泵或电加热作为辅助热源进行对比分析与优化。系统能耗、辅热量与房间热舒适性设定为目标值,通过响应曲面法分析集热器面积、集热器倾角及供暖循环泵流量等对目标值的影响,从而对工况进行优化。太阳能与空气源热泵互补供暖系统最优工况为:集热倾角43.71°、空气源热泵功率6.47 kW、供暖泵流量4.08 m~3/h;对应目标值能耗4799.11 kWh、热泵辅助加热量16953.3 kWh、PPD_19.84%、PPD_2 9.62%。太阳能与电加热互补供暖系统最优工况为:集热倾角50°、电加热功率25.77kW、供暖泵流量6 m~3/h;对应目标值能耗18075.6 kWh、电加热辅助加热量17698.75 kWh、PPD_1 9.62%、PPD2 9.35%。经对比分析可知太阳能与空气源热泵互补供暖在高寒地区更具优势。 相似文献
8.
9.
10.
针对制冷和制热两种情况,建立了以稳态仿真为基础的空调数字化仿真系统。首先运用新的制冷剂显式快速计算模型,对制冷剂物性计算程序进行完善。然后采用集中参数法建立了压缩机模型,对压缩机的性能参数进行二元十项的拟合回归。对毛细管建立了均相流分布参数模型,并且针对该计算模型提出了新的无量纲关联式。在部件模型基础上,建立了家用空调系统仿真计算模型,并且对以往的迭代算法进行了改进,提高了系统稳态仿真算法的稳定性。在系统数值模型的基础上,完成了完全面向对象方式的空调器数字化仿真软件。该仿真结果与实验数据吻合较好,软件可有效预测空调器的性能参数。 相似文献
11.
12.
13.
14.
Thermally driven heat pump systems play important roles in the utilization of low-grade thermal energy. In order to evaluate and compare the performances of three different constructions of thermally driven heat pump and heat transformer, the low-dissipation assumption has been adopted to establish the irreversible thermodynamic models of them in the present paper. By means of the proposed models, the heating loads, the coefficients of performance (COPs) and the optimal relations between them for various constructions are derived and discussed. The performances of different constructions are numerically assessed. More importantly, according to the results obtained, the upper and lower bounds of the COP at maximum heating load for different constructions are generated and compared by the introduction of a parameter measuring the deviation from the reversible limit of the system. Accordingly, the optimal constructions for the low-dissipation three-terminal heat pump and heat transformer are determined within the frame of low-dissipation assumption, respectively. The optimal constructions in accord with previous research and engineering practices for various three-terminal devices are obtained, which confirms the compatibility between the low-dissipation model and endoreversible model and highlights the validity of the application of low-dissipation model for multi-terminal thermodynamic devices. The proposed models and the significant results obtained enrich the theoretical thermodynamic model of thermally driven heat pump systems and may provide some useful guidelines for the design and operation of realistic thermally driven heat pump systems. 相似文献
15.
16.
本文以三元非共沸混合工质R407C对传统工质HCFC22进行了替代,搭建了地源热泵系统实验台。考虑到在地源热泵运行时,地下土壤温度会因运行时间和冬夏季节的不同而发生变化,造成热泵的各种不同运行工况。为全面反映热泵的运行状态制订了测试方案,并对测试数据进行了整理和分析。该热泵系统在加热与制冷运行模式下COP均可达到3.6以上。 相似文献
17.
带有高压储液器的制冷系统建模研究 总被引:1,自引:1,他引:0
通过对制冷系统循环特性、变工况特性和参数间耦合特性的分析,遵循热力学基本定律和能量、动量、质量守恒定律,采用稳态和动态建模相结合的方法建立压缩式制冷系统的数学模型。针对换热器建模难点采用分相区和移动边界相结合的方法建立其集总参数动态模型,并且冷凝器与高压储液器相结合,构成冷凝器加储液器的整体部件,文中建立的制冷系统的整体模型,反映了制冷系统工况变化时制冷剂质量的重新分配及其对状态变量的影响,提高了系统建模的精度,最后通过实验对所建模型的准确性进行了验证。 相似文献
18.
现场测量深层岩土热物性方法 总被引:31,自引:1,他引:30
地下岩土的热物性参数是地源热泵地热换热器的设计中所需要的很重要的参数。热物性参数的大小对钻孔的数量及钻孔的深度具有显著的影响,进而影响地源热泵系统的初投资。为了能够在现场测量地下岩土的热物性参数,本文利用一套现场测量设备测量了对地下埋管回路施加的热流与回路中循环水温度随时间的变化,并利用参数估计方法确定地下岩土的热物性参数。 相似文献