空气-地源双热源复合热泵低温制热特性实验研究
引用本文:周光辉,陈圣洁,刘寅,张岑.空气-地源双热源复合热泵低温制热特性实验研究[J].低温与超导,2009,37(10).
作者姓名:周光辉  陈圣洁  刘寅  张岑
作者单位:中原工学院,郑州,450007
摘    要:为缓解单一空气源热泵低温供热性能差的突出问题,设计了空气-地源双热源复合热泵系统。实验研究结果表明,即使在室外-15℃的超低温环境温度工况下,利用少量的低温地下水,复合热泵的制热量较单一空气源热泵提高近50%;能效比提高40%以上。

关 键 词:双热源  复合热泵  制热特性

Experiment research on heat performance of the ground source -air double resources compound heat-pump
Zhou Guanghui,Chen Shengjie,Liu Yin,Zhang Cen.Experiment research on heat performance of the ground source -air double resources compound heat-pump[J].Cryogenics and Superconductivity,2009,37(10).
Authors:Zhou Guanghui  Chen Shengjie  Liu Yin  Zhang Cen
Institution:Zhongyuan University of Technology;Zhengzhou 450007;China
Abstract:In order to alleviate the low efficiency situation of air source heat pump which was operated in low temperature conditions,A ground source-air double resources compound heat-pump system was designed.Experimental results show that the heat supply quantity of compound pump system may rise by 50% approximately and EER can increase by 40% than air-source heat pump even the outdoor ambient temperature is-15℃.
Keywords:Double resources  Compound heat-pump system  Heat characteristics  