首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
张春兵  刘政  郭霞生  章东 《中国物理 B》2011,20(2):24301-024301
Microbubbles promise to enhance the efficiency of ultrasound-mediated drug delivery and gene therapy by taking advantage of artificial cavitation nuclei.The purpose of this study is to examine the ultrasound-induced hemolysis in the application of drug delivery in the presence of microbubbles.To achieve this goal,human red blood cells mixed with microbubbles were exposed to 1-MHz pulsed ultrasound.The hemolysis level was measured by a flow cytometry,and the cavitation dose was detected by a passive cavitation detecting system.The results demonstrate that larger cavitation dose would be generated with the increase of acoustic pressure,which might give rise to the enhancement of hemolysis.Besides the experimental observations,the acoustic pressure dependence of the radial oscillation of microbubble was theoretically estimated.The comparison between the experimental and calculation results indicates that the hemolysis should be highly correlated to the acoustic cavitation.  相似文献   

2.
The effects of acoustic cavitation on in vitro transfection by ultrasound were investigated. HeLa cells were exposed to 1.0 MHz continuous ultrasound in culture media containing the luciferase gene. Transfection efficiency was elevated when an echo contrast agent, Levovist was added or air was dissolved in the medium. When cells were sonicated in medium saturated with Ar, N2 or N2O which have different gamma values (Cp/Cv), or were saturated with He, Ar or Ne with different thermal conductivities, the effectiveness for the dissolved gases in the ultrasound mediated transfection was Ar > N2 > N2O or Ar > Ne > He, respectively. When free radical formation in water by ultrasound was monitored as a measure of inertial cavitation, it was similarly affected by dissolved gases. These results indicate that the efficiency of ultrasound mediated transfection was significantly affected either by occurrence of or by modification of inertial cavitation due to various gases.  相似文献   

3.
It is well known that acoustic cavitation can facilitate the inward transport of genetic materials across cell membranes (sonoporation). However, partially due to the unstationary behavior of the initiation and leveling of cavitation, the sonoporation effect is usually unstable, especially in low intensity conditions. A system which is able to regulate the cavitation level during sonication by modulating the applied acoustic intensity with a feedback loop is implemented and its effect on in vitro gene transfection is tested. The regulated system provided better time stability and reproducibility of the cavitation levels than the unregulated conditions. Cultured hepatoma cells (BNL) mixed with 10 μg luciferase plasmids are exposed to 1-MHz pulsed ultrasound with or without cavitation regulation, and the gene transfection efficiency and cell viability are subsequently assessed. Experimental results show that for all exposure intensities (low, medium, and high), stable and intensity dependent, although not higher, gene expression could be achieved in the regulated cavitation system than the unregulated conditions. The cavitation regulation system provides a better control of cavitation and its bioeffect which are crucial important for clinical applications of ultrasound-mediated gene transfection.  相似文献   

4.
Previously, passive cavitation imaging has been described in the context of continuous-wave high-intensity focused ultrasound thermal ablation. However, the technique has potential use as a feedback mechanism for pulsed-wave therapies, such as ultrasound-mediated drug delivery. In this paper, results of experiments and simulations are reported to demonstrate the feasibility of passive cavitation imaging using pulsed ultrasound insonations and how the images depend on pulsed ultrasound parameters. The passive cavitation images were formed from channel data that was beamformed in the frequency domain. Experiments were performed in an invitro flow phantom with an experimental echo contrast agent, echogenic liposomes, as cavitation nuclei. It was found that the pulse duration and envelope have minimal impact on the image resolution achieved. The passive cavitation image amplitude scales linearly with the cavitation emission energy. Cavitation images for both stable and inertial cavitation can be obtained from the same received data set.  相似文献   

5.
Quantitative experimental observations of single-bubble cavitation in viscoelastic media that would enable validation of existing models are presently lacking. In the present work, single bubble cavitation is induced in an agar gel using a 1.15 MHz high intensity focused ultrasound transducer, and observed using a focused single-element passive cavitation detection (PCD) transducer. To enable quantitative observations, a full receive calibration is carried out of a spherically focused PCD system by a bistatic scattering substitution technique that uses an embedded spherical scatterer and a hydrophone. Adjusting the simulated pressure received by the PCD by the transfer function on receive and the frequency-dependent attenuation of agar gel enables direct comparison of the measured acoustic emissions with those predicted by numerical modeling of single-bubble cavitation using a modified Keller-Miksis approach that accounts for viscoelasticity of the surrounding medium. At an incident peak rarefactional pressure near the cavitation threshold, period multiplying is observed in both experiment and numerical model. By comparing the two sets of results, an estimate of the equilibrium bubble radius in the experimental observations can be made, with potential for extension to material parameter estimation. Use of these estimates yields good agreement between model and experiment.  相似文献   

6.
Liebler M  Dreyer T  Riedlinger RE 《Ultrasonics》2006,44(Z1):e319-e324
In medical applications of high intense focused ultrasound the mechanism of interaction between ultrasound waves and cavitation bubbles is responsible for several therapeutic effects as well as for undesired side effects. Based on a two-phase continuum approach for bubbly liquids, in this paper a numerical model is presented to simulate these interactions. The numerical results demonstrate the influence of the cavitation bubble cloud on ultrasound propagation. In the case of a lithotripter pulse an increased bubble density leads to significant changes in the tensile part of the pressure waveform. The calculations are verified by measurements with a fiber optical hydrophone and by experimental results of the bubble cloud dynamics.  相似文献   

7.
Numerical simulations of cavitation noise have been performed under the experimental conditions reported by Ashokkumar et al. (2007) [26]. The results of numerical simulations have indicated that the temporal fluctuation in the number of bubbles results in the broad-band noise. “Transient” cavitation bubbles, which disintegrate into daughter bubbles mostly in a few acoustic cycles, generate the broad-band noise as their short lifetimes cause the temporal fluctuation in the number of bubbles. Not only active bubbles in light emission (sonoluminescence) and chemical reactions but also inactive bubbles generate the broad-band noise. On the other hand, “stable” cavitation bubbles do not generate the broad-band noise. The weaker broad-band noise from a low-concentration surfactant solution compared to that from pure water observed experimentally by Ashokkumar et al. is caused by the fact that most bubbles are shape stable in a low-concentration surfactant solution due to the smaller ambient radii than those in pure water. For a relatively high number density of bubbles, the bubble–bubble interaction intensifies the broad-band noise. Harmonics in cavitation noise are generated by both “stable” and “transient” cavitation bubbles which pulsate nonlinearly with the period of ultrasound.  相似文献   

8.
The past several decades have witnessed great progress in “smart drug delivery”, an advance technology that can deliver genes or drugs into specific locations of patients’ body with enhanced delivery efficiency. Ultrasound-activated mechanical force induced by the interactions between microbubbles and cells, which can stimulate so-called “sonoporation” process, has been regarded as one of the most promising candidates to realize spatiotemporal-controllable drug delivery to selected regions. Both experimental and numerical studies were performed to get in-depth understanding on how the microbubbles interact with cells during sonoporation processes, under different impact parameters. The current work gives an overview of the general mechanism underlying microbubble-mediated sonoporation, and the possible impact factors (e.g., the properties of cavitation agents and cells, acoustical driving parameters and bubble/cell micro-environment) that could affect sonoporation outcomes. Finally, current progress and considerations of sonoporation in clinical applications are reviewed also.  相似文献   

9.
本文分析了超声空化引起界面湍动对传质过程的影响,提出了相界面上超声空化气泡析出增强边界层液体湍动并促进传质的机理,在传质理论和流体动力学原理的基础上,建立了超声空化引起界面湍动促进的传质机理模型,获得了超声空化引起界面湍动促进的传质系数表达式。实验结果验证了模型的合理性。该模型既证实了超声对传质有强化效应,又对传质过程有很好的预测功能,为工业化提供了理论依据。  相似文献   

10.
Acoustic cavitation has been shown to deliver molecules into viable cells, which is of interest for drug and gene delivery applications. To address mechanisms of these acoustic bioeffects, this work measured the lifetime of albumin-stabilized cavitation bubbles (Optison) and correlated it with desirable (intracellular uptake of molecules) and undesirable (loss of cell viability) bioeffects. Optison was exposed to 500 kHz ultrasound (acoustic pressures of 0.6-3.0 MPa and energy exposures of 0.2-200 J/cm2) either with or without the presence of DU145 prostate cancer cells (10(6) cells/ml) bathed in calcein, a cell-impermeant tracer molecule. Bubble lifetime was determined using a Coulter counter and flow cytometer, while bioeffects were evaluated by flow cytometry. The lifetime of Optison cavitation nuclei was found to decrease and bioeffects (molecular uptake and loss of cell viability) were found to increase with increasing acoustic energy exposure. These bioeffects correlated well with the disappearance of bubbles, suggesting that contrast agent destruction either directly or indirectly affected cells, probably involving unstabilized cavitation nuclei created upon the destruction of Optison. Because Optison solutions presonicated to destroy all detectable bubbles also caused significant bioeffects, the indirect mechanism involving secondary cavitation bubbles is more likely.  相似文献   

11.
范鹏飞  于洁  杨鑫  屠娟  郭霞生  黄品同  章东 《中国物理 B》2017,26(5):54301-054301
High intensity focused ultrasound(HIFU) has shown a great promise in noninvasive cancer therapy. The impact of acoustic cavitation on the lesion formation induced by HIFU is investigated both experimentally and theoretically in transparent protein-containing gel and ex vivo liver tissue samples. A numerical model that accounts for nonlinear acoustic propagation and heat transfer is used to simulate the lesion formation induced by the thermal effect. The results showed that lesions could be induced in the samples exposed to HIFU with various acoustic pressures and pulse lengths. The measured areas of lesions formed in the lateral direction were comparable to the simulated results, while much larger discrepancy was observed between the experimental and simulated data for the areas of longitudinal lesion cross-section. Meanwhile,a series of stripe-wiped-off B-mode pictures were obtained by using a special imaging processing method so that HIFUinduced cavitation bubble activities could be monitored in real-time and quantitatively analyzed as the functions of acoustic pressure and pulse length. The results indicated that, unlike the lateral area of HIFU-induced lesion that was less affected by the cavitation activity, the longitudinal cross-section of HIFU-induced lesion was significantly influenced by the generation of cavitation bubbles through the temperature elevation resulting from HIFU exposures. Therefore, considering the clinical safety in HIFU treatments, more attention should be paid on the lesion formation in the longitudinal direction to avoid uncontrollable variation resulting from HIFU-induced cavitation activity.  相似文献   

12.
杨日福  洪旭烨 《应用声学》2018,37(4):455-461
本文基于流体动力学控制方程和VOF模型,在FLUENT 14.5软件环境下对超声空化泡进行数值模拟。首先研究了超声空化泡一个周期内的形态变化,并且利用空化泡形态变化的最大面积、最小面积、膨胀时间、收缩时间等数值结果分析超声参数对空化效果的影响。同时探究了双频超声作用下空化泡运动的变化,计算结果表明:在其他条件相同的情况下,在1~5MPa范围内,超声声压幅值为3MPa时空化效果最好;当超声频率大于20kHz时,空化效果随着超声频率的增大而降低。对于频率相同的双频超声,较声压幅值为其两倍的单频超声有更好的空化效果;对于频率不同的双频超声,空化效果受到频率差的影响。  相似文献   

13.
基于界面跟踪方法的汽蚀模型和算法的有效性验证   总被引:1,自引:1,他引:0  
针对两相附着汽蚀流动机理,基于界面跟踪方法发展了新的汽蚀模型和算法。所发展的汽蚀模型和算法不仅考虑了液相/气相界面处的压力差,而且考虑了耦合Reynolds-Averaged Navier-Stokes方程求解技术得到的流场压力梯度信息来迭代计算附着汽蚀形状。采用具有试验数据的半球形头部圆柱体汽蚀绕流作为算例来验证所提出的汽蚀模型和算法的有效性。采用不同的网格数和松弛因子数值验证了发展的汽蚀模型和算法的有效性。三种汽蚀数下的数值计算结果得到的压力系数分布与试验数据完全吻合。结果表明所提出的汽蚀模型和算法能够准确模拟出汽蚀发生点和汽蚀长度。  相似文献   

14.
Poor drug penetration through tumor tissue has emerged as a fundamental obstacle to cancer therapy. The aim of this study was to examine the ability of cavitation instigated by high-intensity focused ultrasound (HIFU) to increase convective transport of a model therapeutic in an in vitro tumor model. Cavitation activity was quantified by analyzing passively recorded acoustic emissions, and mass transfer was quantified using post-treatment image analysis of the distribution of a dye-labeled macromolecule. The strong correlation between cavitation activity and drug delivery suggests the potential for non-invasive treatment and monitoring.  相似文献   

15.
To address difficulties in treating large volumes of liquid metal with ultrasound, a fundamental study of acoustic cavitation in liquid aluminium, expressed in an experimentally validated numerical model, is presented in this paper. To improve the understanding of the cavitation process, a non-linear acoustic model is validated against reference water pressure measurements from acoustic waves produced by an immersed horn. A high-order method is used to discretize the wave equation in both space and time. These discretized equations are coupled to the Rayleigh-Plesset equation using two different time scales to couple the bubble and flow scales, resulting in a stable, fast, and reasonably accurate method for the prediction of acoustic pressures in cavitating liquids. This method is then applied to the context of treatment of liquid aluminium, where it predicts that the most intense cavitation activity is localised below the vibrating horn and estimates the acoustic decay below the sonotrode with reasonable qualitative agreement with experimental data.  相似文献   

16.
Dual- or multiple-frequency ultrasound stimulation is capable of effectively enhancing the acoustic cavitation effect over single-frequency ultrasound. Potential application of this sonoreactor design has been widely proposed such as on sonoluminescence, sonochemistry enhancement, and transdermal drug release enhancement. All currently available sonoreactor designs employed multiple piezoelectric transducers for generating single-frequency ultrasonic waves separately and then these waves were mixed and interfered in solutions. The purpose of this research is to propose a novel design of generating dual-frequency ultrasonic waves with single piezoelectric elements, thereby enhancing acoustic cavitation. Macroscopic bubbles were detected optically, and they were quantified at either a single-frequency or for different frequency combinations for determining their efficiency for enhancing acoustic cavitation. Visible bubbles were optically detected and hydrogen peroxide was measured to quantify acoustic cavitation. Test water samples with different gas concentrations and different power levels were used to determine the efficacy of enhancing acoustic cavitation of this design. The spectrum obtained from the backscattered signals was also recorded and examined to confirm the occurrence of stable cavitation. The results confirmed that single-element dual-frequency ultrasound stimulation can enhance acoustic cavitation. Under certain testing conditions, the generation of bubbles can be enhanced up to a level of five times higher than the generation of bubbles in single-frequency stimulation, and can increase the hydrogen peroxide production up to an increase of one fold. This design may serve as a useful alternative for future sonoreactor design owing to its simplicity to produce dual- or multiple-frequency ultrasound.  相似文献   

17.
Ultrasound-mediated drug delivery is a nonchemical, nonviral, and noninvasive method for targeted transport of drugs and genes into cells. Molecules can be delivered into cells when ultrasound disrupts the cell membrane by a mechanism believed to involve cavitation. This study examined molecular uptake and cell viability in cell suspensions (DU145 prostate cancer and aortic smooth muscle cells) exposed to varying peak negative acoustic pressures (0.6-3.0 MPa), exposure times (120-2000 ms), and pulse lengths (0.02-60 ms) in the presence of Optison (1.7% v/v) contrast agent. With increasing pressure and exposure time, molecular uptake of a marker compound, a calcein, increased and approached equilibrium with the extra cellular solution, while cell viability decreased. Varying pulse length produced no significant effect. All viability and molecular uptake measurements collected over the broad range of ultrasound conditions studied correlated with acoustic energy exposure. This suggests that acoustic energy exposure may be predictive of ultrasound's nonthermal bioeffects.  相似文献   

18.
We present a model developed for studying the generation of stable cavitation bubbles and their motion in a three-dimensional volume of liquid with axial symmetry under the effect of finite-amplitude phased array focused ultrasound. The density of bubbles per unit volume is determined by a nonlinear law which is a threshold-dependent function of the negative acoustic pressure reached in the liquid, in which nuclei are initially distributed. The nonlinear mutual interaction of ultrasound and bubble oscillations is modeled by a nonlinear coupled differential system formed by the wave and a Rayleigh-Plesset equations, for which both the pressure and the bubble oscillation variables are unknown. The system, which accounts for nonlinearity, dispersion, and attenuation due to the bubbles, is solved by numerical approximations. The nonlinear acoustic pressure field is then used to evaluate the primary Bjerknes force field and to predict the subsequent motion of bubbles. In order to illustrate the procedure, a medium-high and a low ultrasonic frequency configurations are assumed. Simulation results show where bubbles are generated, the nonlinear effects they have on ultrasound, and where they are relocated. Despite many physical restrictions and thanks to its particularities (two nonlinear coupled fields, bubble generation, bubble motion), the numerical model used in this work gives results that show qualitative coherence with data observed experimentally in the framework of stable cavitation and suggest their usefulness in some application contexts.  相似文献   

19.
Sonoporation, ultrasound-mediated membrane perforation can potentially puncture plasma membrane and rigid cell wall on presumably reversible basis which benefit gene transfection and plant biotechnology. Herein, positively charged poly-ethyleneimine (PEI)-coated mesoporous silica nanoparticles (MSNs) with an average diameter of 100 ± 8.7 nm was synthesized for GUS-encoding plasmid delivery into the suspended tobacco cells using the ultrasound treatment. The overall potential of PEI-MSN for DNA adsorption was measured at 43.43 μg DNA mg−1 PEI-MSNs. It was shown that high level of sonoporation may adversely upset the cell viability. Optimal conditions of ultrasonic treatment are obtained as 8 min at 3 various intensities of 160, 320 and 640 W. Histochemical staining assay was used to follow the protein expression. It was shown that PEI-coated MSNs efficiently transfer the GUS-encoding plasmid DNA into the tobacco cells. The results of this study showed that ultrasonic treatment provides an economical and straightforward approach for gene transferring into the plant cells without any need to complicated devices and concerns about safety issues.  相似文献   

20.
Hydrodynamic cavitation has been investigated extensively in the field of water treatment in the last decade and a well-designed hydrodynamic cavitation reactor is critical to the efficient removal of algal and large-scale application. In this paper, a jet pump cavitation reactor (JPCR) is developed for the removal of cyanobacteria Microcystis aeruginos in a pilot scale. The results demonstrate that the photosynthetic activity of M. aeruginosa is greatly inhibited immediately after treatment in the JPCR, and the growth is also hindered after 3 days culture. Moreover, a high cell disruptions of M. aeruginosa is detected after treated by JPCR. The release of chlorophyll-a indicates that the JPCR caused serious rupture to M. aeruginosa cells. The plausible cell disruption mechanisms are proposed in accordance with a fluorescence microscope and scanning electron microscope. Then, the optimization of cell disruption efficiency is also investigated for various operating conditions. The results showed that the algal cell disruption efficiency is improved at higher inlet pressure and the cavitation stage between the unstable limited operation cavitation stage and stable limited operation cavitation stage. The effect and optimization of JPCR on algal reduction are highlighted. The results of the study promote the application of hydrodynamic cavitation on algal removal and provide strong support for JPCR application in algal removal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号