首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
A dedicated breast CT system (DBCT) is a new method for breast cancer detection proposed in recent years. In this paper, the glandular dose in the DBCT is simulated using the Monte Carlo method. The phantom shape is half ellipsoid, and a series of phantoms with different sizes, shapes and compositions were constructed. In order to optimize the spectra, monoenergy X-ray beams of 5-80 keV were used in simulation. The dose distribution of a breast phantom was studied: a higher energy beam generated more uniform distribution, and the outer parts got more dose than the inner parts. For polyenergtic spectra, four spectra of Al filters with different thicknesses were simulated, and the polyenergtic glandular dose was calculated as a spectral weighted combination of the monoenergetic dose.  相似文献   

2.
The main purpose of this study was to validate and compare Mean Glandular Dose (MGD) values obtained using Monte Carlo simulations with experimental values obtained from Entrance Surface Dose (ESD) and depth dose measurements performed in a Hospital mammography unit. ESD and depth dose were measured using ThermoLuminescent Dosimeters (TLDs), and a tissue equivalent mammography phantom recommended by the American College of Radiology (ACR). Measurements and Monte Carlo simulations were also compared with the MGD calculated using the Automatic Exposure Control (AEC) system of the mammographic unit. In the simulations the Doppler energy broadening effect was also taken into account. The simulated ESD are about 5%–10% higher than the measured ESD values. The deviation between the measured and simulated MGD values in the phantom is of about 15%. The MGD evaluated using the AEC system is smaller both with respect to the Monte Carlo simulation and experimental result by a factor of about 15% and 25% respectively. Moreover the BackScatter Factor (BSF) estimated by Monte Carlo simulations was used for the MGD calculation according to the Wu’s method. Finally the inclusion of the energy broadening effect on MGD calculation produces negligible variations on the simulated results.  相似文献   

3.
In-beam PET成像是碳离子放射治疗剂量监测的有效手段,可以对碳离子放疗过程的物理剂量分布和生物剂量分布进行实时监测。结合放射治疗计划系统(TPS)和蒙特卡罗(MC)模拟分别对静态均匀水模体和腹部肿瘤CT图像进行治疗计划设计、MC计算和PET成像,比较TPS肿瘤靶区剂量分布、MC模拟剂量分布和PET成像三者之间的一致性。TPS和MC模拟中相对生物学效应(RBE)的计算均采用线性二次模型(LQ)。研究结果显示,TPS和MC计算的静态均匀水模体、单野治疗腹部肿瘤的物理剂量、RBE加权剂量在SOBP区域的平均误差均在0.5%和2%以内。碳离子束流能量为120~400 MeV/u时,束流方向剂量深度分布与PET成像在SOBP区域的位置差异均在8 mm以内。In-beam PET可作为碳离子放射治疗中位置验证和剂量验证的有效手段。  相似文献   

4.
We have designed a phantom to evaluate mean glandular dose (MGD) as part of the regulatory dosimetry control for mammographic equipment. The phantom is constituted by TLD-100 thermoluminescent dosemeters (TLDs) inserted within semicircular plates of acrylic. Different groups of TLDs are used to determine entrance surface air kerma and half-value layer (HVL). Calibration of both tasks has been performed using a Senographe 2000D system and an ionization chamber. The phantom has been tested in five clinical systems. The HVL and MGD obtained by this method agree, on average, within 3%, with those from standard procedures based on the use of ionization chambers. The phantom MGD measurements have a combined uncertainty better than 10% (k = 1).  相似文献   

5.
The AD-4/ACE collaboration studies the biological effects of antiprotons with respect to a possible use of antiprotons in cancer therapy. In vitro experiments performed by the collaboration have shown an enhanced biological effectiveness for antiprotons relative to protons. One concern is the normal tissue dose resulting from secondary neutrons produced in the annihilation of antiprotons on the nucleons of the target atoms. Here we present the first organ specific Monte Carlo calculations of normal tissue equivalent neutron dose in antiproton therapy through the use of a segmented CT-based human phantom. The MCNPX Monte Carlo code was employed to quantify the peripheral dose for a cylindrical spread out Bragg peak representing a treatment volume of 1 cm diameter and 1 cm length in the frontal lobe of a segmented whole-body phantom of a 38 year old male. The secondary neutron organ dose was tallied as a function of energy and organ.  相似文献   

6.
ObjectivePurpose of the study is to verify the Gamma Knife Extend™ system (ES) based fractionated stereotactic radiosurgery with newly developed head-thorax phantom.MethodsPhantoms are extensively used to measure radiation dose and verify treatment plan in radiotherapy. A human upper body shaped phantom with thorax was designed to simulate fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife. The central component of the phantom aids in performing radiological precision test, dosimetric evaluation and treatment verification. A hollow right circular cylindrical space of diameter 7.0 cm was created at the centre of this component to place various dosimetric devices using suitable adaptors. The phantom is made of poly methyl methacrylate (PMMA), a transparent thermoplastic material. Two sets of disk assemblies were designed to place dosimetric films in (1) horizontal (xy) and (2) vertical (xz) planes. Specific cylindrical adaptors were designed to place thimble ionization chamber inside phantom for point dose recording along xz axis. EBT3 Gafchromic films were used to analyze and map radiation field. The focal precision test was performed using 4 mm collimator shot in phantom to check radiological accuracy of treatment. The phantom head position within the Extend™ frame was estimated using encoded aperture measurement of repositioning check tool (RCT). For treatment verification, the phantom with inserts for film and ion chamber was scanned in reference treatment position using X-ray computed tomography (CT) machine and acquired stereotactic images were transferred into Leksell Gammaplan (LGP). A patient treatment plan with hypo-fractionated regimen was delivered and identical fractions were compared using EBT3 films and in-house MATLAB codes.ResultsRCT measurement showed an overall positional accuracy of 0.265 mm (range 0.223 mm–0.343 mm). Gamma index analysis across fractions exhibited close agreement between LGP and film measured dose with ≥90% (max 93%) pixel pass rate at 1 mm of spatial and 1% of dosimetric tolerances. The focal precision test showed the variation of 0.465 mm between radiological and planned iso-centre.ConclusionsThe study demonstrated the suitability of newly developed head-thorax phantom for dosimetric verification of fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife.  相似文献   

7.
使用蒙特卡罗方法研究入射电子束参数对XHA600D医用电子直线加速器产生的剂量分布的影响,并确定优化的入射电子束参数。根据厂商提供的XHA600D加速器治疗头的几何、材料参数,使用蒙特卡罗程序EGSnrc对不同的入射电子束参数进行模拟并记录其在水模体中产生的剂量分布,将模拟结果与测量结果进行比较。模拟的入射电子束参数包括平均能量、径向强度分布、角度展宽和能量展宽;实验测量数据包括4 cm×4 cm、10 cm×10 cm、30 cm×30 cm射野条件下的百分深度剂量与离轴剂量。结果表明当入射电子束的平均能量为6 MeV、径向强度的半高宽(Full Width at Half Maximum, FWHM)为0.25 cm、角度展宽为0.15°时,模拟结果和测量结果吻合非常好。这些参数可以作为建立适用于XHA600D加速器的TPS(Treatment Planning System)剂量计算模型的基础参数。  相似文献   

8.
Patient doses from computed tomography (CT) examinations are usually expressed in terms of dose index, organ doses, and effective dose. The CT dose index (CTDI) can be measured free-in-air or in a CT dosimetry phantom. Organ doses can be measured directly in anthropomorphic Rando phantoms using thermoluminescent detectors. Organ doses can also be calculated by the Monte Carlo method utilizing measured CTDI values. In this work, organ doses were assessed for three main CT examinations: head, chest, and abdomen, using the different mentioned methods. Results of directly measured doses were compared with calculated doses for different organs in the study, and also compared with published international studies.  相似文献   

9.
Radiotherapy with a proton beam of initial energy 55–80 MeV is presently the clinically recommended therapy for some cases of intraocular melanoma such as large melanomas or tumours adjacent to critical organs. Evaluation and optimization of radiation doses outside the treatment volume may contribute to reducing undesirable side-effects and decreasing the risk of occurrence of secondary cancers, particularly for paediatric patients. In this work the undesired doses to organs were assessed basing on Monte Carlo calculation of secondary radiation transport and on results of measurements of neutron and γ-ray doses at the proton therapy facility of the Institute of Nuclear Physics at Kraków. Dosimetry was performed using a He-3-based FHT 762 neutron monitor (Wendi II), a FH40G proportional counter (for γ-rays), and MTS-7 (LiF:Mg,Ti) thermoluminescence detectors (TLDs). Organ doses were calculated in the ADAM anthropomorphic phantom using the MCNPX Monte Carlo transport code and partly verified, for γ-ray doses, with TLD measurements in the RANDO Anderson anthropomorphic phantom. The effective dose due to undesired radiation, including exposure from scattered radiation during the entire process of proton radiotherapy and patient positioning using X-rays, does not exceed 1 mSv.  相似文献   

10.
In this study, we characterized Cerenkov radiation generated in polystyrene (PS)- and polymethyl methacrylate (PMMA)-based plastic optical fibers (POFs) to select an adequate optical fiber for producing Cerenkov radiation. To determine the relationship between the absorbed dose and the intensity of Cerenkov radiation, we calculated the energy depositions of photon beams and fluxes of electrons inducing Cerenkov radiation using the Monte Carlo N-Particle eXtended code. Also, intensities of Cerenkov radiation generated in PS- and PMMA-based POFs were measured as functions of dose rate and monitor unit. At last, therapeutic photon beams-induced Cerenkov radiation in PS- and PMMA-based POFs was measured according to depths of solid water phantom.  相似文献   

11.
This study aims to investigate the detection limits of gold nanoparticle (GNP) concentrations by Monte Carlo (MC) modeling of benchtop polychromatic K- and L-shell X-ray fluorescence mapping system. In Monte Carlo N-Particle (MCNP version 6.1) simulations, a 0.25-cm-diameter cylinder containing GNPs of various concentrations (i.e., 0.005%–1.0% gold by weight, wt%) was assumed to be located at the center of a cylindrical water phantom of various diameters (1.0–10 cm). Two different sets of incident pencil beam X-rays and detectors were modeled to stimulate X-ray fluorescence (XRF) of GNPs: (1) 62 kVp and silicon drift detector for L-XRF, (2) 105 kVp and cadmium telluride detector for K-XRF. The detection limits were calculated for given radiation doses to the center of phantom (375–1500 mGy). When the diameter of the phantom was 1 cm, the detection limits for L-XRF and K-XRF were an order of 0.001 wt% and of 0.01 wt%, respectively. The detectability of K-XRF turned out to be superior to that of L-XRF for the phantoms greater than or equal to 3 cm in diameter. The MC results will provide a guide for developing an optimal benchtop XRF imaging system for in vivo preclinical imaging, depending on the sizes of GNP-loaded objects, GNP concentrations, and radiation doses.  相似文献   

12.
This study is a part of the beam comparison campaign, inter-center dose comparison, between boron neutron capture therapy facilities at the Tsing Hua Open-pool Reactor and the High Flux Reactor. The clinical information exchange can improve the dosimetry uncertainty for medical physics in a mixed field. The method of paired Mg(Ar) and TE(TE) ionization chambers was used to determine the gamma-ray and neutron dose rates. Furthermore, activation foils, including gold, copper, and manganese, were employed to estimate the thermal and epithermal neutron fluxes. Measurements were performed free in air and also in a PMMA phantom. All the chambers were calibrated using a 60Co primary standard source at the Institute of Nuclear Energy Research, Taiwan. Spectrum dependent neutron sensitivity of TE(TE) chamber is one of the important parameters to evaluate dose components. The requested neutron spectra were calculated by the Monte Carlo code MCNP. The measured thermal neutron fluxes, gamma-ray and neutron dose rates of the THOR beam in the phantom were 2.6, 2.2, and 2.1 times of the HFR beam at 2.5-cm depth, respectively. The higher thermal neutron flux and neutron and gamma-ray dose rates are due to the higher epithermal neutron beam intensity of the THOR.  相似文献   

13.
可通过楔形装置把离子束(质子和重离子)纵向上的的深度剂量分布转换成横向上的剂量分布,进行离子束射程的快速测量及验证。本工作通过基于GEANT4内核的GATE蒙特卡罗模拟平台,模拟计算了不同能量碳离子束在用于制作楔形装置的铜、铝、铁和有机玻璃等材料中的深度剂量分布,得到不同能量碳离子束在不同材料中Bragg峰位所处深度与能量之间的关系;模拟计算了不同能量碳离子束穿越单楔板、双楔板和大小组合楔板等楔形装置后横向上的剂量分布,得到了横向剂量峰值出现位置与碳离子束射程之间的关系。本文蒙特卡罗模拟研究为进一步开发重离子治疗当中的射程快速验证方法与设备奠定了坚实的基础。  相似文献   

14.
The Monte Carlo model for the photon-beam output from the Varian Clinac 2100 linear accelerator was validated to compare the calculated to measured PDD and beam dose profiles The Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The objective of this study is to build a Monte Carlo geometry of Varian Clinac 2100 linear accelerator as realistically as possible. The Monte Carlo codes used in this work were the BEAMnrc code to simulate the photons beam and the DOSXYZnrc code to examinate the absorbed dose in the water phantom. We have calculated percentage depth dose (PDD) and beam profiles of the 6 MV photon beam for the 6 × 6 cm2, 10 × 10 cm2 and 15 × 15 cm2 field sizes. We have used the gamma index technique for the quantitative evaluation to compare the measured and calculated distributions. Good agreement was found between calculated PDD and beam profile compared to measured data. The comparison was evaluated using the gamma index method and the criterions were 3% for dose difference and 3 mm for distance to agreement. The gamma index acceptance rate was more than 97% of both distribution comparisons PDDs and dose profiles and our results were more developed and accurate. The Varian Clinac 2100 linear accelerator was accurately modeled using Monte Carlo codes: BEAMnrc and DOSXYZnrc codes package.  相似文献   

15.
在碳离子放射治疗中,碳离子束与治疗头设备和患者身体相互作用产生的次级粒子可以到达患者体内的许多区域,在产生的次级粒子中以中子和$\gamma $射线的产额为最大。在不影响束流配送功能的情况下,减少碳离子放疗中产生的次级中子和$\gamma $射线对于降低放疗后出现的正常组织并发症及二次肿瘤风险有着非常重要的意义。本文利用蒙特卡罗(Monte Carlo)方法模拟计算了被动式束流配送系统下,400 MeV/u碳离子束照射到由不同材料叶片构成的多叶光栅(MLC)形成典型的10 cm×10 cm方形射野时,在水模体中产生的次级中子和$\gamma $射线所沉积的剂量及空间分布等。模拟结果显示:碳离子束通过MLC形成射野后在水模体中产生的次级中子主要分布在水模体的入射端,次级$\gamma $射线较为均匀的分布在整个水模体内,且较多分布在具有展宽Bragg峰(SOBP)射野在水模体中贯穿时的坪区。对于MLC叶片材料的选择,则需根据实际情况对叶片厚度以及次级粒子当量剂量的要求来确定。本文通过模拟研究不同MLC叶片材料产生次级粒子的情况,为被动式束流配送系统中MLC叶片及其他元件的材料选择提供了科学依据。  相似文献   

16.
Opielinski KJ  Gudra T 《Ultrasonics》2004,42(1-9):705-711
The paper presents the method of the three-dimensional reconstruction of biological objects' internal structure heterogeneity based on the ultrasonic examination of a woman's breast biopsy phantom. The phantom is made of quasi-homogeneous dense gel in which drops of lesions, characterized by fixed sizes and two different acoustic impedances, were dipped at random. For the purpose of this research a special measurement setup was elaborated, enabling a non-invasive in vitro imaging of biological objects' internal structure in cross-sections for fixed levels, by means of ultrasound transmission tomography (UTT) using the parallel-ray projection geometry of scanning. The two-dimensional images of the local values of ultrasonic wave's propagation velocity in the phantom's internal structure (ultrasonic tomograms) were reconstructed for fixed levels (by using the convolution and back-projection algorithm) from the measurements of average values of ultrasonic signals' runtime propagated from many directions around the object dipped in water. Analyzing the values of particular pixels and using an appropriate image processing technique, in effect the three-dimensional image of heterogeneity boundaries in the examined phantom's internal structure was computer-reconstructed. The obtained results are compatible with the specification provided by the phantom's producer in terms of sizes and acoustic parameters of lesions, which can simulate pathological changes and of the gel imitating the healthy tissue. It means that the method presented, after an appropriate modification and development of the measurement setup with an aim to accelerate the object scanning process and thus provide an opportunity for non-invasive in vivo examinations, could be applied for detecting and diagnosing tumors in women's breasts.  相似文献   

17.
This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120?kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140?kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.  相似文献   

18.
This paper reports results from the first measurements made on the exterior of a LEO spacecraft of mean dose equivalent rate and average quality factor as functions of shielding depth for shielding less than 1 g/cm2 Al equivalent. Two sets of measurements were made on the outside of the Mir Orbital Station; one near solar maximum in June 1991 and one near solar minimum in 1997. Absorbed dose was measured using stacks of TLDs. LET spectrum from charged particles of LET infinity H2O > o r= 5keV/micrometers was measured using stacks of CR-39 PNTDs. Results from the TLD and PNTD measurements at a given shielding depth were combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Measurements made near solar maximum tend to be greater than those made during solar minimum. Both mean dose rate and mean dose equivalent rate decrease by nearly four orders of magnitude within the first g/cm2 shielding illustrating the attenuation of both trapped electrons and low-energy trapped protons. In order to overcome problems with detector saturation after standard chemical processing, measurement of LET spectrum in the least shielded CR-39 PNTD layer (0.005 g/cm2 Al) was carried out using an atomic force microscope.  相似文献   

19.
ABSTRACT

This paper draws attention to the study of performance of a new Molecular Breast Imaging (MBI) device, whose purpose is the early diagnosis of breast cancer, using Monte Carlo simulations. MBI provides functional and specific information that are more appropriated to dense breasts. Two asymmetric heads with different types of collimators, facing each other in anti-parallel viewing direction, characterize the system. Detectors and phantoms, together with the data taking procedure, are shortly reported. Monte Carlo simulations using the GATE (GEANT4 Application for Tomographic Emission) simulation toolkit have been implemented to evaluate the optimal detector configuration, in terms of sensitivity and spatial resolution, and also to reproduce the real experimental data. The device can be used both in spot compression and in Limited Angle Tomography (LAT); in the latter configuration one detector head with pinhole collimator is able to rotate around the breast in order to diagnose and localized the small tumors.  相似文献   

20.
The specific absorbed fractions(SAF) for self- and cross-irradiation are effective tools for the internal dose estimation of inhalation and ingestion intakes of radionuclides. A set of SAFs of photons and electrons were calculated using the Rad-HUMAN phantom, which is a computational voxel phantom of a Chinese adult female that was created using the color photographic image of the Chinese Visible Human(CVH) data set by the FDS Team. The model can represent most Chinese adult female anatomical characteristics and can be taken as an individual phantom to investigate the difference of internal dose with Caucasians. In this study, the emission of mono-energetic photons and electrons of 10 ke V to 4 Me V energy were calculated using the Monte Carlo particle transport calculation code MCNP. Results were compared with the values from ICRP reference and ORNL models. The results showed that SAF from the Rad-HUMAN have similar trends but are larger than those from the other two models. The differences were due to the racial and anatomical differences in organ mass and inter-organ distance. The SAFs based on the Rad-HUMAN phantom provide an accurate and reliable data for internal radiation dose calculations for Chinese females.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏