首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  免费   0篇
  国内免费   5篇
物理学   5篇
  2013年   1篇
  2012年   2篇
  2011年   1篇
  2004年   1篇
排序方式: 共有5条查询结果,搜索用时 0 毫秒
1
1.
工业CT图像均匀性校正   总被引:1,自引:0,他引:1  
在工业CT图像重建过程中,射束硬化使得图像出现“杯状”伪影,阵列探测器响应不一致使得图像出现环状伪影、带状伪影和点伪影,影响图像均匀性.本文分析了射束硬化的原理和探测器响应不一致的数学模型,并通过实验,对探测器响应进行多挡板定标得到校正系数表.利用查表插值的方法对投影数据进行均匀性校正,消除上述伪影.  相似文献   
2.
A dedicated breast CT system (DBCT) is a new method for breast cancer detection proposed in recent years. In this paper, the glandular dose in the DBCT is simulated using the Monte Carlo method. The phantom shape is half ellipsoid, and a series of phantoms with different sizes, shapes and compositions were constructed. In order to optimize the spectra, monoenergy X-ray beams of 5-80 keV were used in simulation. The dose distribution of a breast phantom was studied: a higher energy beam generated more uniform distribution, and the outer parts got more dose than the inner parts. For polyenergtic spectra, four spectra of Al filters with different thicknesses were simulated, and the polyenergtic glandular dose was calculated as a spectral weighted combination of the monoenergetic dose.  相似文献   
3.
In this paper, we present a beam hardening correction (BHC) method in three-dimension space for a cone-beam computed tomography (CBCT) system in a mono-material case and investigate its effect on the spatial resolution. Due to the polychromatic character of the X-ray spectrum used, cupping and streak artifacts called beam hardening artifacts arise in the reconstructed CT images, causing reduced image quality. In addition, enhanced edges are introduced in the reconstructed CT images because of the beam hardening effect. The spatial resolution of the CBCT system is calculated from the edge response function (ERF) on different planes in space. Thus, in the CT images with beam hardening artifacts, enhanced ERFs will be extracted to calculate the modulation transfer function (MTF), obtaining a better spatial resolution that deviates from the real value. Reasonable spatial resolution can be obtained after reducing the artifacts. The 10% MTF value and the full width at half maximum (FWHM) of the point spread function with and without BHC are presented.  相似文献   
4.
Computed laminography (CL) is an alternative to computed tomography if large objects are to be inspected with high resolution. This is especially true for planar objects. In this paper, we set up a new scanning geometry for CL, and study the algebraic reconstruction technique (ART) for CL imaging. We compare the results of ART with variant weighted functions by computer simulation with a digital phantom. It proves that ART algorithm is a good choice for the CL system.  相似文献   
5.
The spatial resolution and the relative density resolution are the two most critical indicators in CT system. The method recommended in the ASTM E1695-95 and GJB 5311-2004 is only suitable to the fan-beam CT system. In this paper, for industrial cone-beam micro CT system, we will adopt the edge response function (ERF) created by the step edges of a steel ball to measure the system 3D PSF and MTF. To describe the contrast discrimination function more accurately, we will first propose to extend the two-dimensional measurement region to the three-dimensional space. Our experimental spatial resolution is (55.56±0.56) lp/mm and the relative density resolution is 1% within 300 μm×300 μm×300 μm according to the 3σ rule.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号