首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
Auralizations are commonly used today by architectural acousticians as a tool to model acoustically sensitive spaces. This paper presents investigations employing an auralization methodology known as multi-channel auralizations, to determine the benefits of using an increasing number of channels in such auralizations. First an objective evaluation was conducted to examine how acoustic parameters, such as reverberation time, vary when using “quadrant” (one fourth of a spherical source) or “thirteenth” sources to create the binaural room impulse responses. Large differences in the values were found between the different sections of the sphere, on the order of several just noticeable differences. Two subjective studies were then pursued, first to determine if auralizations made with an increasing number of channels sound more realistic and have an increased perceived source size, using solo musical instruments of varying directivity indices as the sources. Overall, subjects perceived the auralizations made with an increasing number of channels as more realistic, whereas results for perceived source size are less clear. The second subjective study assessed the ease with which subjects could identify the source orientation from the auralizations as a function of number of channels. Results indicate that more channels made it easier for subjects to differentiate between source orientations.  相似文献   

2.
厅堂声学测量中不同激励声源的比较   总被引:3,自引:0,他引:3       下载免费PDF全文
孟子厚 《应用声学》2005,24(1):19-23
基於脉冲响应积分的音乐厅和剧院观众厅声学特性的测量目前有三种使用不同激励声源的测试方法:人工脉冲声源、伪随机噪声序列(MLS)、以及用正弦扫频信号。这些技术各有其优缺点,在实际应用中为了方便根据具体情况选择不同的激励声源,通过在一个音乐厅现场的实测数据比较丁三种声源的实测结果,发现对混响时间测量三种不同的激励声源给出的结果基本一致,但是对明晰度和一些其他的指标,脉冲声源给出的结果与用MLS和扫频信号给出的结果有较明显的差别。对实际中如何选择具体的技术也做了建议。  相似文献   

3.
Acoustical measurements based on impulse responses have been made in a Protestant and a Catholic church in Hong Kong. Analysis has concentrated on reverberation time, early decay time and C80, the early-to-late ratio, as well as integrated decays. The measured results have been compared with predictions according to two different theoretical room acoustic models: a model for a single diffuse space and one for a set of coupled-rooms. The comparison has shown that treating the churches as a series of coupled spaces is more valid. However the clarity, C80, at different receiver positions was found to be either under- or over-estimated by the classical coupled-room model. Following this observation, a delayed coupled-room model was developed in the hope of achieving more accurate predictions. In this model, the initial condition under the impulse excitation was modified by introducing a time delay for sound propagated from the source to achieve diffuse sound fields in each subspace. The predicted results of the coupled-room model agree well with the measured results.  相似文献   

4.
基于声舒适度的地下餐饮空间声级阈研究   总被引:1,自引:0,他引:1       下载免费PDF全文
陈曦  康健 《应用声学》2016,35(2):157-164
为了确定地下餐饮空间内使用者主观声舒适度可接受时的声压级阈值范围,本文选取典型的封闭式地下餐饮空间作为研究对象,采用实地问卷与实测相结合的方法进行调研。结果表明:地下餐饮空间内整体环境舒适度主观评价偏低,声舒适度评价与整体环境舒适度评价具有强相关性,因此声环境是影响地下餐饮空间内整体环境舒适度的因素。在影响主观声舒适度评价的客观指标中,混响时间可不作为主要影响因素考虑;而背景噪声声压级是影响地下餐饮空间内声舒适度主观评价的重要指标。使用者声舒适度为可接受时,地下餐饮空间内背景噪声声压级阈值为70-75 dB(A)。  相似文献   

5.
Studies dedicated to the determination of acoustic characteristics of an automotive cooling package are presented. A shrouded subsonic axial fan is mounted in a wall separating an anechoic- and a reverberation room. This enables a unique separation of the up- and downstream sound fields. Microphone measurements were acquired of the radiated sound as a function of rotational speed, fan type and components included in the cooling module. The aim of the present work is to investigate the effect of a closely mounted radiator upstream of the impeller on the SPL spectral distribution. Upon examination of the SPL spectral shape, features linked specifically to the source and system are revealed. The properties of a reverberant sound field combined with the method of spectral decomposition permit an estimation of the source spectral distribution and the acoustic transfer response, respectively. Additionally, purely intrinsic acoustic properties of the radiator are scrutinized by standardized ISO methods. A new methodology comprising a dipole sound source is adopted to circumvent limitation of transmission loss measurement in the low frequency range. The sound attenuation caused by the radiator alone was found to be negligible.  相似文献   

6.
目标声源的低信噪比是目标定位技术中的瓶颈。在浅海近似均匀环境中,利用虚拟接收方法对声源测距的目标定位方法相比于传统的匹配场定位方法可以避免对环境参数和声场模型的依赖,同时省去生成拷贝场时的大量计算。通过数值模拟和实验数据处理,比较了在虚拟接收方法声源测距中不同信噪比的引导声源对目标声源测距的结果。提高引导声源的信噪比,可以一定程度上提高于涉条纹清晰度,从而提高测距准确度。提高引导声源的信噪比可作为目标声源的信噪比补偿是利用虚拟接收方法的目标定位技术的又一个优点。   相似文献   

7.
Speech-intelligibility tests auralized in a virtual classroom were used to investigate the optimal reverberation times for verbal communication for normal-hearing and hearing-impaired adults. The idealized classroom had simple geometry, uniform surface absorption, and an approximately diffuse sound field. It contained a speech source, a listener at a receiver position, and a noise source located at one of two positions. The relative output levels of the speech and noise sources were varied, along with the surface absorption and the corresponding reverberation time. The binaural impulse responses of the speech and noise sources in each classroom configuration were convolved with Modified Rhyme Test (MRT) and babble-noise signals. The resulting signals were presented to normal-hearing and hearing-impaired adult subjects to identify the configurations that gave the highest speech intelligibilities for the two groups. For both subject groups, when the speech source was closer to the listener than the noise source, the optimal reverberation time was zero. When the noise source was closer to the listener than the speech source, the optimal reverberation time included both zero and nonzero values. The results generally support previous theoretical results.  相似文献   

8.
Auralization facilitates aural examination of contributions from different sound sources, individually and as parts of a context. Auralizations can be created by filtering sounds of the perceptually most salient sources through binaural transfer functions (BTFs) from source positions to a listening position. When psychoacoustic analysis is based on auralizations, the auralizations need to give the same impression as real sounds. The objective of this study was to determine the frequency resolution required for auralizations to be perceptually equivalent to recordings made with an artificial head. Auralizations of the contribution of engine sounds to interior sounds of a truck were examined. In listening tests auralizations based on simplified BTFs were compared to artificial head recordings. The BTFs were simplified by lowering the frequency resolution and by smoothing in the frequency domain. Auralizations made through BTFs with a resolution of 4 Hz or higher or smoothed with maximum 1/96 octave moving average filters were perceived as similar to artificial head recordings.  相似文献   

9.
针对船用PN10DN32三通调节阀噪声声压频谱、声指向性等声学特性规律不明确,噪声声压级是否满足使用要求的问题,基于流-固耦合理论,同时考虑流-固耦合面及流体域内的脉动声学激励源,开展阀门噪声数值模拟研究。分别对三通调节阀在80%及60%开度阀外1 m处的噪声进行数值模拟,分析研究噪声声压频谱特性及声指向性规律。结果表明:80%及60%开度下的噪声声压级分别为49.14 dB(A)、50.79 dB(A),均小于60 d B(A)的噪声限制,满足使用要求。该文为船用三通调节阀噪声数值模拟提供了理论及方法参考。  相似文献   

10.
The increasing presence of low frequency sources and the lack of acoustic standard measurement procedures make the extension of reverberation time measurements to frequencies below 100 Hz necessary. In typical ordinary rooms with volumes between 30 m3 and 200 m3 the sound field is non-diffuse at such low frequencies, entailing inhomogeneities in space and frequency domains. Presence of standing waves is also the main cause of bad quality of listening in terms of clarity and rumble effects. Since standard measurements according to ISO 3382 fail to achieve accurate and precise values in third octave bands due to non-linear decays caused by room modes, a new approach based on reverberation time measurements of single resonant frequencies (the modal reverberation time) has been introduced. From background theory, due to the intrinsic relation between modal decays and half bandwidth of resonant frequencies, two measurement methods have been proposed together with proper measurement procedures: a direct method based on interrupted source signal method, and an indirect method based on half bandwidth measurements. With microphones placed at corners of rectangular rooms in order to detect all modes and maximize SNRs, different source signals were tested. Anti-resonant sine waves and sweep signal turned out to be the most suitable for direct and indirect measurement methods respectively. From spatial measurements in an empty rectangular test room, comparison between direct and indirect methods showed good and significant agreements. This is the first experimental validation of the relation between resonant half bandwidth and modal reverberation time. Furthermore, comparisons between means and standard deviations of modal reverberation times and standard reverberation times in third octave bands confirm the inadequacy of standard procedure to get accurate and precise values at low frequencies with respect to the modal approach. Modal reverberation time measurements applied to furnished ordinary rooms confirm previous results in the limit of modal sound field: for highly damped modes due to furniture or acoustic treatment, the indirect method is not applicable due to strong suppression of modes and the consequent deviation of the acoustic field from a non-diffuse condition to a damped modal condition, while standard reverberation times align with direct method values. In the future, further investigations will be necessary in different rooms to improve uncertainty evaluation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏