首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A irreversible Hg2+ selective ratiometric fluorescence probe FR, a fluorescein fluorophore linked to a rhodamine B hydrazide by a thiourea spacer, was designed and synthesized. The developed probe FR exhibited great ratiometric fluorescence enhancement and remarkable yellow-magenta color change toward Hg2+ with excellent selectivity in aqueous acetone solution, and the ratiometric fluorescence response to Hg2+ was not interfered by other metal cations including Fe3+, Co2+, Ni2+, Cr3+, Zn2+, Pb2+, Cd2+, Ca2+, Mg2+, Ba2+ and Mn2+. The linear range and the detection limit of this supposed ratiometric fluorescence method for Hg2+ were 0.0–10.0 × 10−6 and 5 × 10−8 M, respectively.  相似文献   

2.
Xu X  Zhang L  Shen D  Wu H  Liu Q 《Journal of fluorescence》2008,18(1):193-201
The serum albumin is the most abundant protein in blood plasma and the iron is essential for many cellular processes. However, the interaction between Fe3+ and haem-free serum albumin remains unclear. Here we provide evidence for the fact that haem-free BSA possesses one specific Fe3+-binding site. The binding of Fe3+ to BSA results in a significant quenching of the Trp fluorescence of BSA. The average apparent dissociation constant value for the interaction of Fe3+ and BSA is 3.46 × 10−8 ± 3 × 10−10 M at 37 °C and 3.30 × 10−8 ± 5 × 10−10 M at 25 °C, respectively, as determined by fluorescence titration. Addition of 50 μM Fe2+ to 1 μM BSA results in an obvious hysteretic effect on the fluorescence of BSA. The time-dependent fluorescence quenching of BSA by Fe2+ is not caused by the Fe2+-induced conformational change of BSA, but the oxygen-dependent oxidation of Fe2+ to Fe3+. Fe2+ undergoes an oxygen-dependent oxidation to Fe3+ under aerobic conditions, which is accelerated by the interaction of BSA with Fe3+ and extensively inhibited under anaerobic conditions. The results suggest that BSA may take part in non-transferrin bound iron transfer.  相似文献   

3.
A new cryptand compound carrying 2-hydroxy-1-naphthylidene Schiff base moiety (3) was designed and synthesized by reaction of the corresponding macrobicyclic amine compound (1) and 2-hydroxy-1-naphthaldehyde (2). The influence of metal cations such as Mg2+, Ca2+, Sr2+, Fe2+,Co2+, Mn2+, Zn2+, Cd2+, Hg2+, Al3+ and Pb2+ on the spectroscopic properties of the new fluoroionophore was investigated in acetonitrile-dichloromethane solution (9.5/0.5) by means of absorption and emission spectrometry. The blue shifts on the fluorescence spectrum were observed for all metal cations at 504nm. At the same time the fluorescence spectrum of the ligand showed quenching in the intensity of the signal at 504 nm for all metal cations except for Zn2+. Interaction of Co2+ with the ligand caused quenching of naphtyl fluorescence higher than 84%. The method showed good selectivity and sensitivity for Co2+ with respect to other metal cations with linear range and detection limit of 1.5 × 10−7 to 3.3 × 10−6M and 4.8 × 10−8M respectively.  相似文献   

4.
A new pyrene derivative (chemosensor 1) containing a picolinohydrazide moiety exhibits high selectivity for Cu2+ ion detection in mixed aqueous media (CH3OH:H2O = 7:3). Significant fluorescence enhancement was observed with chemosensor 1 in the presence of Cu2+. However, the metal ions Ag+, Ca2+, Cd2+, Co2+, Cu2+, Fe2+, Fe3+, Hg2+, K+, Mg2+, Mn2+, Ni2+, Pb2+, and Zn2+ produced only minor changes in fluorescence for the system. The apparent association constant (K a) of Cu2+ binding in chemosensor 1 was found to be 2.75*103 M−1. The maximum fluorescence enhancement caused by Cu2+ binding in chemosensor 1 was observed over the pH range 5–8. Moreover, by means of fluorescence microscopy experiments, it is demonstrated that 1 can be used as a fluorescent probe for detecting Cu2+ in living cells.  相似文献   

5.
A new anthracene-based fluorescent PET sensor 1 with a tridentate ionophore of amide/β-amino alcohol displays very good selectivity and sensitivity for Fe3+ (K a = 1.6 × 103 M−1) and Hg2+ (K a = 2.1 × 103 M−1) in CH3CN–H2O (3:7, v/v) with detection limit of 1 μM. More fluorescence enhancement was observed when 1 selectively detected Fe3+ or Hg2+ in CH3CN and its detection limit was up to 0.03 μM.  相似文献   

6.
Zhang F  Wu X  Zhan J 《Journal of fluorescence》2011,21(5):1857-1864
A sensitive and selective method for the trace determination of 3, 3’, 4, 4’-tetrachlorobiphenyl (PCB77) by using bovine serum albumin (BSA) as a fluorescence probe was introduced. Under optimum conditions, the enhanced fluorescence intensity was proportional to the concentration of polychlorinated biphenyls in the range of 8.9 × 10−8–5.0 × 10−6 mol L−1 for PCB77, and 5.0 × 10−7–5.0 × 10−6 mol L−1 for 2, 2’, 5, 5’-tetrachlorbiphenyl (PCB52). The detection limits (S/N = 3) of PCB77 and PCB52 were 2.6 × 10−8 mol L−1 and 2.9 × 10−7 mol L−1, respectively. Furthermore, the fluorescence enhancement mechanism was discussed in detail. Results indicated that fluorescence enhancement of the system originated from the formation of BSA-PCBs complexes. In addition, PCBs were mainly bound to the tyrosine residues in BSA molecules.  相似文献   

7.
A novel and simple fluorescence enhancement method for selective pyrophosphate(PPi) sensing was proposed based on a 1:1 metal complex formation between bis(8-hydroxy quinoline-5-solphonat) chloride aluminum(III) (Al(QS)2Cl), (L) and PPi in aqueous solution. The linear response range covers a concentration range of 1.6 × 10−7 to 1.0 × 10−5 mol/L of PPi and the detection limit of 2.3 × 10−8 mol/L. The association constant of L-PPi complex was calculated 2.6 × 105 L/mol. L was found to show selectively and sensitively fluorescence enhancement toward PPi over than I3-, NO3-, CN, CO32−, Br, Cl, F, H2PO4 and SO42−, which was attributed to higher stability of inorganic complex between pyrophosphate and L.  相似文献   

8.
Two indole-based fluorescent chemosensors 1 and 2 were prepared and investigated characteristic features with transition metal ions. Sensors 1 and 2 were selective for Hg2+ ion, among a series of metal ions, in aqueous ethanol (H2O–EtOH, 1:2, v/v) with association constants of 5.74 × 103 and 4.46 × 103 M−1 and detection limits of 7.4 and 6.8 μM, respectively. Computational results revealed that sensor 1 or 2 with Hg2+ ion formed 1:1 complex with a central, sandwich-coordinated Hg2+ ion. Computational calculations provided evidence that a sandwich-coordinated Hg2+ ion center was formed and the polyoxyethylene spacer acted as a scaffold for bringing functional ligands into a suitable geometry.  相似文献   

9.
Liu SR  Wu SP 《Journal of fluorescence》2011,21(4):1599-1605
A new 7-nitrobenz-2-oxa-1,3-diazole (NBD) derived fluorescent probe (1) exhibiting high selectivity for Cu2+ detection, produced significant fluorescence quenching in the presence of Cu2+ ion, while the metal ions Ca2+, Cd2+, Co2+, Fe2+, Hg2+, Mg2+, Mn2+, Ni2+ and Zn2+ produced only minor changes in fluorescence. The apparent association constant (K a) for Cu2+ binding in chemosensor 1 was found to be 1.22 × 103 M−1. The maximum fluorescence quenching activity caused by Cu2+ binding to 1 was observed over the pH range 6–10.  相似文献   

10.
A new, simple and accurate spectrofluorimetric method for the determination of metoclopramide hydrochloride was developed. The metoclopramide hydrochloride can remarkably enhance the luminescence intensity of the Tb3+ ion doped in PMMA matrix at λex = 360 nm in methanol at pH 6.9. The intensity of the emission band at 545 nm of Tb3+ ion doped in PMMA matrix is increased due to the energy transfer from metoclopramide hydrochloride to Tb3+ in the excited stated. The effect of different parameters, e.g., pH, temperature, Tb3+ concentration, foreign ions that control the fluorescence intensity of the produced ion associate was critically investigated. The calibration curve of the emission intensity at 545 nm shows linear response of metoclopramide over a concentration range of 5 × 10−5–5.0 × 10−8 M with detection limit of 8.7 × 10−10 M. The method was used successfully for the determination of metoclopramide in pharmaceutical preparations and human serum. The average recovery of 99.48% with standard deviation of 0.32% and 96.98% with standard deviation of 0.4%, of pharmaceutical preparations and human serum respectively, were obtained which compared will with the results obtained from standard LC method of average recovery 99.04% and standard deviation of 0.6% and average recovery of 98.19% with standard deviation of 0.6% of pharmaceutical preparations and human serum, respectively.  相似文献   

11.
Water-soluble Mn2+-doped ZnS quantum dots (QDs) were prepared using mercaptoacetic acid as the stabilizer. The optical properties and structure features were characterized by X-Ray, absorption spectrum, IR spectrum and fluorescence spectrum. In pH 7.8 Tris-HCl buffer, the QDs emitted strong fluorescence peaked at 590 nm with excitation wavelength at 300 nm. The presence of sulfide anion resulted in the quenching of fluorescence and the intensity decrease was proportional to the S2− concentration. The linear range was from 2.5 × 10−6 to 3.8 × 10−5 mol L−1 with detection limit as 1.5 × 10−7 mol L−1. Most anions such as F, Cl, Br, I, CH3CO2 , ClO4 , CO3 2−, NO2 , NO3 , S2O3 2−, SO3 2− and SO4 2− did not interfere with the determination. Thus a highly selective assay was proposed and applied to the determination of S2− in discharged water with the recovery of ca. 103%.  相似文献   

12.
Four novel copper(II) complexes of the composition [CuLX] where L = 2,6-bis(benzimidazole-2yl)pyridine, X = dipyridophenazine (L1), 1,10-phenanthroline (L2), hydroxyproline (L3) and 2,6-pyridine dicarboxylic acid (L4) were synthesized and characterized by using elemental analysis, FT-IR, UV–vis, ESI-MS, molar conductance and magnetic susceptibility measurements. The complexes [CuLL1](NO3)2 [1], [CuLL2](NO3)2 [2], [CuLL3](NO3) [3] and [CuLL4] (NO3) [4] are stable at room temperature. In DMSO the complexes [1] and [2] are 1:2 electrolytes, [3] and [4] are 1:1 electrolytes. Based on elemental and spectral studies five coordinated geometry is assigned to all the four complexes. The interaction of four copper ion complexes with calf thymus DNA were carried out by UV–vis titrations, fluorescence spectroscopy, thermal melting and viscosity measurements .The binding constant (Kb) of the above four metal complexes were determined as 5.43 × 104 M,−1 2.56 × 104 M−1, 1.21 × 104 M−1 and 1.57 × 104 M−1 respectively. Quenching studies of the four complexes indicates that these complexes strongly bind to DNA, out of all complex 1 is binding more strongly. Viscosity measurements indicate the binding mode of complexes with CT DNA by intercalation through groove. Thermal melting studies also support intercalative binding. The nuclease activity of the above metal complexes shows that 1, 2 and 3 complexes cleave DNA through redox chemistry.  相似文献   

13.
In this study, a very sensitive and highly selective irreversible optical chemical sensor (optode) for mercury ions was described. The sensing scheme was based on the interaction of Hg (II) with a newly synthesized fluoroionophore; chloro phenyl imino propenyl aniline (CPIPA) in plasticized PVC membrane. The sensor membranes were tested for the determination of mercury ion in aqueous solutions by batch and flow-through methods. The optodes allow determination of Hg (II) in the working range of 1.0 × 10−9–1.0 × 10−5 M with a detection limit of 4.3 ppb. The sensor exhibited excellent selectivity for Hg (II) with respect to several common alkali, alkaline earth and transition metal ions. The association constant of the 1:1 complex formation for Hg (II) was found to be Ka = 1.86 × 105 M−1. The CPIPA exhibited high fluorescence quantum yield, long excitation and emission wavelength and high Stokes’ shift values in the solid matrix which makes it compatible with solid state optics.  相似文献   

14.
It is found that silver nanoparticles (AgNPs) can further enhance the fluorescence intensity of curcumin (CU) - cetyltrimethylammonium bromide (CTAB) – nucleic acids and improve its anti-photobleaching activity. Under optimum conditions, the enhanced fluorescence intensity is proportion to the concentration of nucleic acids in the range of 2.0 × 10−8–1.0 × 10−6 g mL−1 for fish sperm DNA (fsDNA), 2.0 × 10−8–1.0 × 10−6 g mL−1 for calf thymus DNA (ctDNA), 1.0 × 10−8–1.0 × 10−6 g mL−1 for yeast RNA (yRNA), and their detection limits (S/N = 3) are 8.0 ng mL−1, 10.5 ng mL−1 and 5.8 ng mL−1, respectively. This method is used for determining the concentration of DNA in actual sample with satisfactory results. The interaction mechanism is also studied.  相似文献   

15.
In this paper we reported a metal complex 1-Zn (2,5-di-[2-(3,5-bis(2-pyridylmethyl)amine-4-hydroxy-phenyl)-ethylene]-pyrazine-Zn) as a fluorescent probe sensing DNA. The result of the competitive experiment of the probe with ethidium bromide (EB) to bind DNA, absorption spectral change and polarization change in the presence and absence of DNA revealed that interaction between the probe and DNA was via intercalation. Ionic strength experiment showed the existence of electrostatic interaction as well. Scatchard plots also confirmed the combined binding modes. The fluorescence enhancement of the probe was ascribed to highly hydrophobic environment when it bound the macromolecules such as DNA, RNA or denatured DNA. The binding constant between the probe and DNA was estimated as 3.13 × 107 mol−1 L. The emission intensity increase was proportional to the concentration of DNA. Based on this, the probe was used to determine the concentration of calf thymus DNA (ct-DNA). The corresponding linear response ranged from 2.50 × 10−7 to 4.75 × 10−6 mol L−1, and detection limit was 1.93 × 10−8 mol L−1 for ct-DNA.  相似文献   

16.
We report here an experimental study of the ionic keV X-ray line emission from magnesium plasma produced by laser pulses of three widely different pulse durations (FWHM) of 45 fs, 25 ps and 3 ns, at a constant laser fluence of ∼1.5 × 104 J cm − 2. It is observed that the X-ray yield of the resonance lines from the higher ionization states such as H- and He-like ions decreases on decreasing the laser pulse duration, even though the peak laser intensities of 3.5 × 1017 W cm − 2 for the 45 fs pulses and 6.2 × 1014 W cm − 2 for the 25 ps pulses are much higher than 5 × 1012 W cm − 2 for the 3 ns laser pulse. The results were explained in terms of the ionization equilibrium time for different ionization states in the heated plasma. The study can be useful to make optimum choice of the laser pulse duration to produce short pulse intense X-ray line emission from the plasma and to get the knowledge of the degree of ionization in the plasma.  相似文献   

17.
CdHgTe nanoparticles (NPs) with the emission in the near-infrared regions were prepared in aqueous solution, and were characterized by transmission electron microscopy, X-ray diffraction spectrometry, spectrofluorometry and ultraviolet-visible spectrometry. Based on the fluorescence quenching of CdHgTe NPs in the presence of proteins, a novel method for the determination of proteins with CdHgTe NPs as a near-infrared fluorescence probe was developed. Maximum fluorescence quenching was observed with the excitation and emission wavelengths of 500 and 693 nm, respectively. Under the optimal conditions, the calibration graphs were linear in the range of 0.04 × 10−6–5.6 × 10−6 g ml−1 for lysozyme (Lyz) and 0.06 × 10−6–6.1 × 10−6 g ml−1 for bovine hemoglobin (BHb), respectively. The limits of detection were 13 ng ml−1 for Lyz and 27 ng ml−1 for BHb, respectively. Four synthetic samples were determined and the results were satisfied.  相似文献   

18.
A fluorescent assay of Hg2+ in neutral aqueous solution was developed using N-[p-(dimethylamino)benzamido]-N′-phenylthiourea (1). 1’s fluorogenic chemodosimetric behaviors towards various metal ions were studied and a high sensitivity as well as selectivity was achieved for Hg2+. It was because of a strongly fluorescent 1,3,4-oxadiazoles which was produced by the Hg2+ promoted desulfurization reaction. The spectra of ESI mass and IR provided evidences for this reaction. According to fluorescence titration, a good linear relationship ranging from 1.0 × 10−7 to 2.0 × 10−5 mol l−1 was obtained with the limit of detection as 3.1 × 10−8 mol l−1. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

19.
A simple, rapid and effective analytical method based on fluorescence spectroscopy for the determination of coumarin in pharmaceutical formulations without pre-treatment or pre-concentration step was development. Coumarin had maximum excitation and emission at 310 nm and 390 nm, respectively. Optimum conditions for the detection of coumarin were investigated. Under optimized conditions, we observed a linear behavior for the sign of coumarin in the concentration range of 2.5 × 10−6 to 1.0 × 10−4 mol L−1, with linearity of 0.998 and sensitivity of 2.9 × 1010 u.a/mol L−1. The proposed method was validated in terms of accuracy, precision and specificity of coumarin using the standard addition and external calibration. It was noted that the results support (P < 0.05), indicating that the matrices were not an interference in the determination of coumarin by fluorescence spectroscopy. The results were favorable compared with those obtained by reference chromatographic methods.  相似文献   

20.
In our study, terbium-acetylacetone (Tb-acac) composite nanoparticles have been prepared under vigorous ultrasonic irradiation. The nanoparticles are water soluble, stable and have extremely narrow emission bands and high internal quantum efficiencies. They were used as fluorescence probes in the determination of enoxacin (Enox) based on the fluorescence enhancement of nanoparticles through fluorescence resonance energy transfer (FRET). The influence of buffer solution on the fluorescence intensity was investigated. Under the optimum conditions, the fluorescence intensity of the Tb-acac-Enox system is linearly proportional to the Enox concentration in the Enox concentration range of 2 × 10−7–1 × 10−4 M. The correlation coefficient for the calibration curve was 0.9976. The limit of detection as defined by IUPAC, C LOD = 3S b/m (where S b is the standard deviation of the blank signals and m is the slope of the calibration graph) was found to be 3 × 10−8 M. The relative standard deviation (RSD) for six repeated measurements of 1 × 10−4 M Enox was 1.35%. The method was applied to the determination of Enox in pharmaceutical formulation and recovery results were obtained from urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号