首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A fluorescent assay of Hg2+ in neutral aqueous solution was developed using N-[p-(dimethylamino)benzamido]-N′-phenylthiourea (1). 1’s fluorogenic chemodosimetric behaviors towards various metal ions were studied and a high sensitivity as well as selectivity was achieved for Hg2+. It was because of a strongly fluorescent 1,3,4-oxadiazoles which was produced by the Hg2+ promoted desulfurization reaction. The spectra of ESI mass and IR provided evidences for this reaction. According to fluorescence titration, a good linear relationship ranging from 1.0 × 10−7 to 2.0 × 10−5 mol l−1 was obtained with the limit of detection as 3.1 × 10−8 mol l−1. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

2.
3.
A new anthracene-based fluorescent PET sensor 1 with a tridentate ionophore of amide/β-amino alcohol displays very good selectivity and sensitivity for Fe3+ (K a = 1.6 × 103 M−1) and Hg2+ (K a = 2.1 × 103 M−1) in CH3CN–H2O (3:7, v/v) with detection limit of 1 μM. More fluorescence enhancement was observed when 1 selectively detected Fe3+ or Hg2+ in CH3CN and its detection limit was up to 0.03 μM.  相似文献   

4.
The interactions of norfloxacin (NFA), DNA, and Cu2+ are studied by fluorescence and UV-spectra method. According to the experimental results, it can be concluded that NFA can form a steady binary complex with Cu2+. There is a linear relationship between the Fluorescence intensity of the norfloxacin–Cu2+–DNA system and the concentration of DNA. And when the concentration of the NFA is 1.95×10−5 mol L−1, they possess a good linearity in the concentration of DNA ranged from 4.7×10−6 to 2.8×10−5 mol L−1.It is a good method due to the high sensitivity and selectivity.  相似文献   

5.
Wu X  Guo C  Yang J  Wang M  Chen Y  Liu J 《Journal of fluorescence》2005,15(5):655-660
A new quantitative method for micro amounts of nucleic acids in aqueous solution is proposed using Eu3+-benzoylacetone (BA) complex as fluorescent probe in the presence of cetyltrimethyl-ammonium bromide (CTMAB). Under the optimum condition, the ratio of the fluorescence intensities with and without nucleic acids is proportional to the concentration of nucleic acid in the range of 1.0 × 10−9 to 5.0 × 10−6 g/mL for herring sperm DNA (hsDNA), 3.0 × 10−9 to 1.0 × 10−6 g/mL for calf thymus DNA(ctDNA) and 8.0 × 10−9 to 1.0 × 10−6 g/mL for yeast RNA (yRNA), and their detection limits are 0.33, 0.21 and 0.99 ng/mL, respectively. Actual sample (DNA of Arabidopsis thaliana) was determined satisfactorily. In addition, the interaction mechanism is also investigated.  相似文献   

6.
A new cryptand compound carrying 2-hydroxy-1-naphthylidene Schiff base moiety (3) was designed and synthesized by reaction of the corresponding macrobicyclic amine compound (1) and 2-hydroxy-1-naphthaldehyde (2). The influence of metal cations such as Mg2+, Ca2+, Sr2+, Fe2+,Co2+, Mn2+, Zn2+, Cd2+, Hg2+, Al3+ and Pb2+ on the spectroscopic properties of the new fluoroionophore was investigated in acetonitrile-dichloromethane solution (9.5/0.5) by means of absorption and emission spectrometry. The blue shifts on the fluorescence spectrum were observed for all metal cations at 504nm. At the same time the fluorescence spectrum of the ligand showed quenching in the intensity of the signal at 504 nm for all metal cations except for Zn2+. Interaction of Co2+ with the ligand caused quenching of naphtyl fluorescence higher than 84%. The method showed good selectivity and sensitivity for Co2+ with respect to other metal cations with linear range and detection limit of 1.5 × 10−7 to 3.3 × 10−6M and 4.8 × 10−8M respectively.  相似文献   

7.
Two indole-based fluorescent chemosensors 1 and 2 were prepared and investigated characteristic features with transition metal ions. Sensors 1 and 2 were selective for Hg2+ ion, among a series of metal ions, in aqueous ethanol (H2O–EtOH, 1:2, v/v) with association constants of 5.74 × 103 and 4.46 × 103 M−1 and detection limits of 7.4 and 6.8 μM, respectively. Computational results revealed that sensor 1 or 2 with Hg2+ ion formed 1:1 complex with a central, sandwich-coordinated Hg2+ ion. Computational calculations provided evidence that a sandwich-coordinated Hg2+ ion center was formed and the polyoxyethylene spacer acted as a scaffold for bringing functional ligands into a suitable geometry.  相似文献   

8.
Zhang F  Wu X  Zhan J 《Journal of fluorescence》2011,21(5):1857-1864
A sensitive and selective method for the trace determination of 3, 3’, 4, 4’-tetrachlorobiphenyl (PCB77) by using bovine serum albumin (BSA) as a fluorescence probe was introduced. Under optimum conditions, the enhanced fluorescence intensity was proportional to the concentration of polychlorinated biphenyls in the range of 8.9 × 10−8–5.0 × 10−6 mol L−1 for PCB77, and 5.0 × 10−7–5.0 × 10−6 mol L−1 for 2, 2’, 5, 5’-tetrachlorbiphenyl (PCB52). The detection limits (S/N = 3) of PCB77 and PCB52 were 2.6 × 10−8 mol L−1 and 2.9 × 10−7 mol L−1, respectively. Furthermore, the fluorescence enhancement mechanism was discussed in detail. Results indicated that fluorescence enhancement of the system originated from the formation of BSA-PCBs complexes. In addition, PCBs were mainly bound to the tyrosine residues in BSA molecules.  相似文献   

9.
In this paper we reported a metal complex 1-Zn (2,5-di-[2-(3,5-bis(2-pyridylmethyl)amine-4-hydroxy-phenyl)-ethylene]-pyrazine-Zn) as a fluorescent probe sensing DNA. The result of the competitive experiment of the probe with ethidium bromide (EB) to bind DNA, absorption spectral change and polarization change in the presence and absence of DNA revealed that interaction between the probe and DNA was via intercalation. Ionic strength experiment showed the existence of electrostatic interaction as well. Scatchard plots also confirmed the combined binding modes. The fluorescence enhancement of the probe was ascribed to highly hydrophobic environment when it bound the macromolecules such as DNA, RNA or denatured DNA. The binding constant between the probe and DNA was estimated as 3.13 × 107 mol−1 L. The emission intensity increase was proportional to the concentration of DNA. Based on this, the probe was used to determine the concentration of calf thymus DNA (ct-DNA). The corresponding linear response ranged from 2.50 × 10−7 to 4.75 × 10−6 mol L−1, and detection limit was 1.93 × 10−8 mol L−1 for ct-DNA.  相似文献   

10.
A simple and sensitive spectrofluorimetric method for determination of trace amount of doxycycline hydrochloride (DC) in pharmaceutical tablets and serum samples was developed. In ammonia buffer solution of pH 8.9 the doxycycline hydrochloride can remarkably enhance the luminescence intensity of the Sm3+ ion in Sm3+- DC complex at λex = 400 nm. The produced luminescence intensity of Sm3+- DC complex in DMSO is in proportion to the concentration of DC and used as optical sensor for its determination. The dynamic range for the determination of DC is 1 × 10−8 – 5 × 10−6 mol L−1 and in case of quantum yield calculations is 7 × 10−9 – 5 × 10−6 mol L−1 with detection limit of 6.5 × 10−10 mol L−1. The enhancement mechanism of the luminescence intensity in the Sm3+- DC system has been also discussed. A comparison with other spectrofluorimetric methods for tetracycline derivatives in which Eu3+ ion is used instead of Sm3+ ion is also studied.  相似文献   

11.
Du J  Fan J  Peng X  Li H  Wang J  Sun S 《Journal of fluorescence》2008,18(5):919-924
A highly selective PET fluorescent sensor B1 for Hg2+ containing a BODIPY fluorophore and a NS2O2 penta-chelating receptor has been synthesized and characterized. Its absorption maximum wavelength (498 nm) and emission maximum wavelength (512 nm) are both in the visible range. The fluorescence quantum yields of the B1 and Hg2+-bound states of BHg1 are 0.008 and 0.58 in 70% aqueous ethanol solution, respectively. The pKa of 1.97 is the lowest in metal ions PET chemo sensors reported up till now as we know. Thus, B1 can detect the Hg2+ in a wide pH span, which indicates that it has more potential and further practical applications for biology and toxicology. Furthermore, BHg1 also displays response to some anions such as Cl(Br), , SCN and CH3COO, which is attributed to the significant coordinating ability of these anions to Hg2+.  相似文献   

12.
Based on resonance energy transfer (FRET) from dansyl to rhodamine 101, a new fluorescent probe (compound 1) containing rhodamine 101 and a dansyl unit was synthesized for detecting Hg2+ through ratiometric sensing in DMSO aqueous solutions. This probe shows a fast, reversible and selective response toward Hg2+ in a wide pH range. Hg2+ induced ring-opening reactions of the spirolactam rhodamine moiety of 1, leading to the formation of fluorescent derivatives that can serve as the FRET acceptors. Very large stokes shift (220 nm) was observed in this case. About 97-fold increase in fluorescence intensity ratio was observed upon its binding with Hg2+.  相似文献   

13.
A 1,8-naphthalimide derivative with a reactive aliphatic hydroxyl was designed and synthesized as a fluorescent probe. Its structure was characterized by IR, 1H NMR, 13C NMR, LC-MS and HPLC. The probe showed high selectivity and sensitivity to Hg2+ over other metal ions such as Pb2+, Na+, K+, Cd2+, Cr3+, Zn2+, Cu2+, Ni2+, Ca2+, Fe3+, Fe2+, Co2+, Mn2+ and Mg2+ in MeCN/H2O (15/85, v/v). The increase in fluorescence intensity was linearly proportional to the concentration of Hg2+ in the range of 18–40 μM with a detection limit of 1.38 × 10?7 mol/L. The probe could work in a pH span of 4.3–9.0 and respond to Hg2+ quickly with strong anti-interference ability. Job’s plot suggested a 1:2 complex of the probe and Hg2+.  相似文献   

14.
A novel solid substrate-room temperature phosphorimetry (SS-RTP) was developed for determination of bumetanide (BMTN). It was validated by determining selectivity, linearity, accuracy, precision, and signal to noise ratio (S/N) for analysis. And all the experiments presented in this work were based on that BMTN inhibited the formation of [Fe-morin]3+ ([FeR]3+) complex by the reaction between Fe3+ and R, which led to severe quenching of room temperature phosphorescence (RTP) signal. The rate constant of the reaction (k) was 2.44 × 10−4 s−1, the activation energy (E) was 21.39 kJ mol−1. Detection limit of this method (LD, 5.0 ag spot−1, corresponding concentration was 1.2 × 10−14 g mL−1) was evaluated and compared with other methods, indicating better sensitivity for BMTN determination using this technique. And due to the high sensitivity of the method, it has been successfully applied to determine BMTN in human urine samples. The linear range was from 0.040 pg mL−1 to 4.0 pg mL−1, allowing wide determined range of BMTN. Meanwhile, the mechanism of this method was also discussed.  相似文献   

15.
Xu X  Zhang L  Shen D  Wu H  Liu Q 《Journal of fluorescence》2008,18(1):193-201
The serum albumin is the most abundant protein in blood plasma and the iron is essential for many cellular processes. However, the interaction between Fe3+ and haem-free serum albumin remains unclear. Here we provide evidence for the fact that haem-free BSA possesses one specific Fe3+-binding site. The binding of Fe3+ to BSA results in a significant quenching of the Trp fluorescence of BSA. The average apparent dissociation constant value for the interaction of Fe3+ and BSA is 3.46 × 10−8 ± 3 × 10−10 M at 37 °C and 3.30 × 10−8 ± 5 × 10−10 M at 25 °C, respectively, as determined by fluorescence titration. Addition of 50 μM Fe2+ to 1 μM BSA results in an obvious hysteretic effect on the fluorescence of BSA. The time-dependent fluorescence quenching of BSA by Fe2+ is not caused by the Fe2+-induced conformational change of BSA, but the oxygen-dependent oxidation of Fe2+ to Fe3+. Fe2+ undergoes an oxygen-dependent oxidation to Fe3+ under aerobic conditions, which is accelerated by the interaction of BSA with Fe3+ and extensively inhibited under anaerobic conditions. The results suggest that BSA may take part in non-transferrin bound iron transfer.  相似文献   

16.
The absorption spectra, fluorescence spectrum and fluorescence decay curve of Nd3+ ions in CaNb2O6 crystal were measured at room temperature. The peak absorption cross section was calculated to be 6.202×10−20 cm2 with a broad FWHM of 7 nm at 808 nm for E//a light polarization. The spectroscopic parameters of Nd3+ ions in CaNb2O6 crystal have been investigated based on Judd-Ofelt theory. The parameters of the line strengths Ω t are Ω 2=5.321×10−20 cm2,Ω 4=1.734×10−20 cm2,Ω 6=2.889×10−20 cm2. The radiative lifetime, the fluorescence lifetime and the quantum efficiency are 167 μs, 152 μs and 91%, respectively. The fluorescence branch ratios are calculated to be β 1=36.03%,β 2=52.29%,β 3=11.15%,β 4=0.533%. The emission cross section at 1062 nm is 9.87×10−20 cm2.  相似文献   

17.
Liu SR  Wu SP 《Journal of fluorescence》2011,21(4):1599-1605
A new 7-nitrobenz-2-oxa-1,3-diazole (NBD) derived fluorescent probe (1) exhibiting high selectivity for Cu2+ detection, produced significant fluorescence quenching in the presence of Cu2+ ion, while the metal ions Ca2+, Cd2+, Co2+, Fe2+, Hg2+, Mg2+, Mn2+, Ni2+ and Zn2+ produced only minor changes in fluorescence. The apparent association constant (K a) for Cu2+ binding in chemosensor 1 was found to be 1.22 × 103 M−1. The maximum fluorescence quenching activity caused by Cu2+ binding to 1 was observed over the pH range 6–10.  相似文献   

18.
A new spectrofluorimetric method was developed for the determination of trace amounts of dopamine (DA). Using chlorosulfonylthenoyltrifluoroacetone (CTTA)–europium ion (Eu3+) as a fluorescent probe, in a buffer solution at pH = 10.0, DA can remarkably enhance the fluorescence intensity of the CTTA-Eu3+ complex at λ = 612 nm; the enhanced fluorescence intensity of Eu3+ is proportional to the concentration of DA. Optimum conditions for the determination of DA were also investigated. The linear range and detection limit for the determination of DA were 5.0 × 10−8∼1.6 × 10−5 mol/l and 3.2 × 10−8 mol/l. This method is simple, practical and relatively free of interference from coexisting substances, and can be applied to assess DA in injection and human serum samples with good precision and accuracy.  相似文献   

19.
Water-soluble Mn2+-doped ZnS quantum dots (QDs) were prepared using mercaptoacetic acid as the stabilizer. The optical properties and structure features were characterized by X-Ray, absorption spectrum, IR spectrum and fluorescence spectrum. In pH 7.8 Tris-HCl buffer, the QDs emitted strong fluorescence peaked at 590 nm with excitation wavelength at 300 nm. The presence of sulfide anion resulted in the quenching of fluorescence and the intensity decrease was proportional to the S2− concentration. The linear range was from 2.5 × 10−6 to 3.8 × 10−5 mol L−1 with detection limit as 1.5 × 10−7 mol L−1. Most anions such as F, Cl, Br, I, CH3CO2 , ClO4 , CO3 2−, NO2 , NO3 , S2O3 2−, SO3 2− and SO4 2− did not interfere with the determination. Thus a highly selective assay was proposed and applied to the determination of S2− in discharged water with the recovery of ca. 103%.  相似文献   

20.
A novel and simple fluorescence enhancement method for selective pyrophosphate(PPi) sensing was proposed based on a 1:1 metal complex formation between bis(8-hydroxy quinoline-5-solphonat) chloride aluminum(III) (Al(QS)2Cl), (L) and PPi in aqueous solution. The linear response range covers a concentration range of 1.6 × 10−7 to 1.0 × 10−5 mol/L of PPi and the detection limit of 2.3 × 10−8 mol/L. The association constant of L-PPi complex was calculated 2.6 × 105 L/mol. L was found to show selectively and sensitively fluorescence enhancement toward PPi over than I3-, NO3-, CN, CO32−, Br, Cl, F, H2PO4 and SO42−, which was attributed to higher stability of inorganic complex between pyrophosphate and L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号