首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 125 毫秒
1.
疏水性离子液体萃取-原子吸收光谱法分离分析微量金   总被引:1,自引:0,他引:1  
Wu J  Fu H  Li BJ  Zhu XS 《光谱学与光谱分析》2011,31(1):260-262
以N-甲基咪唑和溴代正丁烷及六氟磷酸铵合成了疏水性离子液体1-丁基-3-甲基咪唑六氟磷酸盐([Bmim][PF6])。运用该离子液体分离富集分析了微量金。以火焰原子吸收光谱法(FAAS)为分析检测手段,探讨了离子液体萃取预富集微量金的条件。实验结果表明:金的浓度在0.40~16.00μg·mL-1范围内与吸光度成线性关系,线性方程为A=0.00763c+0.07387(c:μg·mL-1),r=0.9991,检测限为0.072μg·mL-1。该法用于样品测定结果令人满意。  相似文献   

2.
本文提出了用0.5ml N-正辛基苯胺-间二甲苯萃取测定岩石矿物中超痕量金的电热石墨炉原子吸收分析方法。对萃取剂的性能、萃取金的条件、其它离子的干扰情况以及在HGA-500型石墨炉中测定金的最佳条件进行了研究。样品用盐酸过氧化氢分解后,溶液进行萃取,有机相直接测定,大量的其它离子不干扰测定,为超痕量金的定量测试提供了简便、高灵敏的方法。本法绝对灵敏度为2.0pg/1%吸收,可检测0.00005g/T金。对含金量为0.0006g/T的矿样重复溶样测定11次,其相对标准偏差为4.4%。  相似文献   

3.
基于表面活性剂的浊点现象,建立了以双硫腙为螯合剂、Triton X-114为表面活性剂的浊点萃取-石墨炉原子吸收光谱法测定痕量铅的新方法。研究了溶液pH值、试剂浓度、平衡温度和加热时间等实验条件对浊点萃取及测定灵敏度的影响。以4 000 r·min-1离心15 min使分相, 分相后的溶液在冰水浴中冷却至接近0 ℃,然后反转离心管弃去水相,用0.1 mol·L-1 HNO3-甲醇溶液定容至0.5 mL, 溶液以磷酸二氢铵及硝酸镁为基体改进剂由石墨炉原子吸收分光光度法进行测定。在pH 8.0和0.05% Triton X-114及20 μmol·L-1双硫腙存在下, 富集10 mL样品溶液,铅的检出限为0.089 μg·L-1,富集倍率为19.1,所得工作曲线回归方程为A=0.0261c(μg·L-1)+0.010 6,线性范围0.1~30 μg·L-1,相关系数r为0.998。方法用于环境水样中测定痕量铅的测定,获得满意结果。  相似文献   

4.
方炳华 《光谱实验室》2008,25(2):106-110
提出了1-(2-噻唑偶氮)-2-萘酚(TAN)浊点萃取石墨炉原子吸收光谱法测定痕量镉的新方法.详细探讨了溶液pH,试剂浓度等实验条件对浊点萃取及测定灵敏度的影响.在最佳条件下.富集10mL样品溶液,用石墨炉原子吸收光谱法测定.镉的检出限为0.037ug/L,镉的富集倍率为20倍.该方法用于环境水样中痕量镉的测定.获得满意结果.  相似文献   

5.
浊点萃取-石墨炉原子吸收法测定高盐样品中的痕量铅   总被引:3,自引:2,他引:1  
在pH 6~7的缓冲体系中,样品溶液中的痕量铅与加入的吡咯烷二硫代氨基甲酸铵(APDC)为络合剂形成稳定的配合物。通过70 ℃恒温水浴3 h,铅配合物被萃取到表面活性剂相并与水相分开。 分离后的表面活性剂相室温就可配成上机待测样液。 此法不但将大量基体离弃在水相,从而消除高盐带来的高背景信号干扰,并将水样或1%食盐溶液的痕量铅富集10~100倍。用氘灯校正背景石墨炉原子吸收法进行测定,方法检出限:食盐0.000 5 μg·g-1,水样0.01 μg·L-1。回收率为92.3%~104%。用于食盐、海水、井水中痕量铅的测定,结果令人满意。  相似文献   

6.
选择双硫腙为络合剂、Triton X-114为表面活性剂,以浊点萃取为样品前处理技术,富集水样中的痕量镉并用石墨炉原子吸收光谱法测定。对影响预富集的条件进行讨论并建立最佳条件,此方法可以应用于水样中镉的测定。在最优条件下,镉的检出限为0.015μg/L。  相似文献   

7.
以表面浸渍固载有疏水性室温离子液体—1-己基-3-甲基咪唑六氟磷酸盐(1-hexyl-3-methylimidazolium hexafluorophosphate,[C6mim]PF6)的Amberlite XAD-7大孔树脂为固相萃取微柱的吸附剂,建立了微柱在线富集和流动注射-分光光度法测定废水中痕量游离态汞的新方法。在酸性介质中和十六烷基三甲基溴化铵(CTMAB)存在下,Hg2+与双硫腙反应生成红色的中性配合物可被微柱有效地定量富集。在优化的实验条件下,方法的线性范围为0.35~50 μg·L-1 Hg2+,检出限为0.067 μg·L-1 Hg2+。进样体积为50 mL时,Hg2+的富集因数为25倍。对环境水质汞标准样品(GSBZ50016-90)和加标废水样品的测定,回收率在99%~103%。  相似文献   

8.
本文提出了用0.5ml N-正辛基苯胺-间二甲苯萃取岩石矿物中超痕量钯铂的石墨炉原子吸收分析方法。对萃取钯铂的条件、其它离子的干扰情况以及在HGA-500型石墨炉中测定钯铂的最佳条件进行了研究。样品用盐酸过氧化氢分解后,溶液进行萃取,有机相直接测定。大量的其它离子不干扰测定。方法的绝对灵敏度釲为5.5pg/1%吸收、铂为40pg/1%吸收,可检测0.0001g/t的钯及0.0005g/t的铂。对含钯0.002g/t 0.006g/t铂矿样重复溶解样品测定11次,其相对标准偏差分别为钯4.9%、铂5.6%。  相似文献   

9.
浊点萃取-火焰原子吸收光谱法测定痕量铅的研究   总被引:1,自引:0,他引:1  
王记莲 《光谱实验室》2011,28(1):299-302
研究了浊点萃取-火焰原子吸收光谱法测定痕量铅的新方法.利用表面活性剂聚乙二醇辛基苯基醚(Triton X-100)和配合剂1-苯基-3-甲基-4-苯甲酰吡喹啉酮-5(PMBP)对试样中的Pb(Ⅱ)进行浊点萃取.并详细探讨了溶液pH值、试剂浓度等实验条件对浊点萃取及测定灵敏度的影响.在最佳条件下,铅的富集倍数为20,检出...  相似文献   

10.
利用纳秒级时间分辨激光光解装置,以Nd:YAG激光器三倍频后的355 nm激光作为激发光源,研究了芘在常规溶剂乙腈、丙酮、环己烷、1-丁基-3-甲基咪唑六氟磷酸离子液体([Bmim][PF6])、N-丁基吡啶四氟硼酸离子液体([BuPy][BF4])以及三乙基庚基铵双三氟甲磺酰亚胺(R4NNTf2)的瞬态光解行为,比较...  相似文献   

11.
建立了用交联羧甲基魔芋葡甘聚糖(CCMKGM)作为微柱预富集填料,分离富集-GFAAS测定环境水样中痕量铅、镉和铜的新方法。研究了溶液酸度、样品的流速和体积、洗脱剂的浓度和体积、共存离子等对CCMKGM微柱吸附重金属离子的影响。结果表明:在pH为5.0~7.0的条件下,三种重金属离子可定量吸附在CCMKGM微柱上;采用1.0 mL 0.5 mol·L-1的盐酸溶液可将吸附在CCMKGM微柱上的铅、镉和铜定量洗脱。Pb2+, Cd2+, Cu2+的检出限()分别为0.038, 0.000 5和0.014 μg·L-1,相对标准偏差(RSD)分别为3.5%, 9.2%和4.7%(初始浓度cPb2+ =cCu2+=1.0 μg·L-1, cCd2+=0.1 μg·L-1,n= 11),富集倍数50。将该法用于环境标准样品的测定,测得值与标准值相符。  相似文献   

12.
建立了以交联羧甲基魔芋葡甘聚糖(CCMKGM)为微柱预富集-GFAAS测定转基因水稻糙米中痕量铅和镉的新方法。考察了溶液的pH值、样品流速和体积、洗脱液的浓度和体积及共存离子干扰等因素对CCMKGM微柱吸附重金属的影响。结果表明:在优化条件下,方法用于富集、测定转基因水稻及亲本糙米中Pb和Cd的检出限分别为0.11和0.002μg.L-1;测定大米标准参考物质中Pb和Cd的含量,结果与标准参考值相吻合。对转基因水稻及亲本糙米进行标准加入回收实验及测定,回收率分别在90%~103%和93%~105%范围。该研究可为转基因水稻中痕量Pb和Cd分析提供技术支持。  相似文献   

13.
An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu2+), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36 μg L−1, respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group.  相似文献   

14.
以轻质溶剂辛醇为萃取剂,建立了分散液液微萃取-石墨炉原子吸收光谱分析法(LDS-DLLME-GFAAS),并应用于生活用水中痕量Pb及Cd的测定。在分散液液微萃取(DLLME)中,以二乙基二硫代氨基甲酸盐(DDTC)为螯合剂,用微量注射器将辛醇和甲醇的混合溶液快速注入到样品溶液中发生雾化分散现象,Pb2+和Cd2+与DDTC的络合物被萃取到辛醇微滴中。离心分离后,以GFAAS测定萃取至上层辛醇相中的分析物。实验考察了萃取剂种类和体积、分散剂种类和体积、pH、DDTC浓度、萃取时间等影响萃取效率的实验参数。在最优实验条件下,Pb和Cd的检出限分别为0.15和0.03 μg·L-1,富集倍数分别为87和48,具有良好的线性和精密度。该分析方法优势在于操作简便,快速,低成本,高富集倍数,萃取剂用量少,已成功应用于自来水、饮用水和南湖水中痕量Pb和Cd的检测。  相似文献   

15.
In the present work, a procedure for the preconcentration and determination of lead trace amounts of lead in fish species and water samples by graphite furnace atomic absorption spectrometry (GF AAS) is proposed, which is based on the batch solid phase extraction of lead ions by modified magnetic nanoparticles. An optimization process was performed using two-level fractional factorial designs (24-1) and a Box–Behnken matrix. Four variables (pH of solution, nanoparticles mass, morin mass, and shaking time) were regarded as factors in the optimization. The detection limit of the proposed method was found to be 81.0 ng/l. Six samples of fish and three samples of water (tap, river, and lake) were analyzed for lead. The lead contents ranged in fish from 0.013 to 0.038 μg/g and in water from 7.1 to 9.0 μg/l.  相似文献   

16.
螯合棉纤维预富集流动注射在线测定痕量铅   总被引:5,自引:0,他引:5  
将自制的性能优越、成本低廉的新型吡咯烷二硫代甲酸铵螯合棉纤维(CC-APDC)作为固相富集材料,经稀硝酸洗脱液的流动注射预富集, 用石墨炉原子吸收光谱测定了痕量铅。流动注射预富集分六步完成。用稀硝酸作洗脱液,完全洗脱需0.15 mL,大大超过石墨管进样体积。实验将洗脱的前40 μL定量弃去,采用定体积取样法,将浓度最高的40 μL洗脱液加入GFAAS中,提高了测定的准确度。另外在石墨炉灰化阶段高记忆效应的消除中,将惯用的停气方式改为小流量(30 mL·min-1,富集1 min)气体原子化,使拖尾现象得到了明显的改善,且空白值低而稳定。考察了实验参数,如酸度,洗脱液浓度,洗脱速度及采样速率等)对分析性能的影响。采用螯合棉纤维作分离富集材料,选择性好,方法灵敏度高,可以在线分离干扰,采样速度50次·h-1。富集倍数15倍,检测下限0.2 μg·L-1,相对标准偏差1.4%(n=10),回收率95%~105%,样品测定结果令人满意。  相似文献   

17.
《应用光谱学评论》2013,48(4):457-474
Abstract

The literature concerning the improvement of atomic and ionic procedures for molybdenum determination through separation and pre‐concentration were updated. Analytical procedures based on flame atomic absorption spectrometry (AAAS), electrothermal or graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled plasma optical emission spectrometry (ICP‐OES), and inductively coupled plasma mass spectrometry were reviewed taking into consideration the preliminary steps, which can enhance the selectivity and sensitivity based on co‐precipitation, solvent extraction, and solid‐phase extraction. Both in‐batch and on‐line procedures were considered.  相似文献   

18.
李延志  张弦 《光谱实验室》2010,27(3):933-936
建立了中成药镉残留量的浊点萃取-石墨炉原子吸收光谱法。样品先经消解,再以非离子表面活性剂浊点萃取富集消解液中的镉,石墨炉原子吸收光谱法测定镉含量。本方法检出限可达0.008ng/mL;加标回收率94.0%—108.5%;线性范围为0—10ng/mL(r=0.9995)。结果表明,采用浊点萃取可提高石墨炉原子吸收光谱法测镉的灵敏度、准确性、重复性和抗干扰能力。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号