首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Mealor D  Townshend A 《Talanta》1968,15(12):1371-1376
Thiourea has been found to enhance the inhibition of invertase by silver ions. The effect is applied to the determination of 1–5 × 10−7 M silver and of 10−7–10−8 M thiourea. A mechanism is suggested for the enhancement.  相似文献   

2.
Zhang N  Zhang X  Zhao Y 《Talanta》2004,62(5):1041-1045
The behavior of the ciprofloxacin (CPFX) complex with copper, Cu(II)L2, at a mercury electrode has been investigated in borax–boric acid buffer. The adsorption phenomena were observed by linear sweep voltammetry. The mechanism of the electrode reaction was found to be reduction of Cu(II)L2 adsorbed on the surface of the electrode by an irreversible charge transfer to metal amalgam, Cu(0)(Hg). In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2–DNA results in the decrease of the equilibrium concentration of Cu(II)L2 and its peak current. Under the optimum conditions, the decrease of the peak current is proportional to DNA concentration. The linear ranges are 6.67×10−8 to 1.20×10−5 g ml−1 for calf thymus DNA (ctDNA), 3.30×10−8 to 2.33×10−6 g ml−1 for fish sperm DNA (fsDNA) and 1.0×10−8 to 1.2×10−6 g ml−1 for yeast RNA. The detection limits are 5.00×10−9, 3.00×10−9 and 2.50×10−9 g ml−1, respectively. This method exhibits good recovery and high sensitivity.  相似文献   

3.
Reartes GB  Liberman SJ  Blesa MA 《Talanta》1987,34(12):1039-1042
The acidity constants of benzidine (Bz) in aqueous solutions determined potentiometrically at 25° were Ka1 = (1.11 ± 0.08) × 10−5, Ka2 = (1.45 ± 0.12) × 10−4. The apparent mixed constants in 0.1M sodium nitrate are Ka1 = (5.37 ± 0.28) × 10−6 and Ka2 = (1.14 ± 0.09) × 10−4. The ultraviolet spectra were recorded as a function of pH and analysed with these constants to obtain the absorption spectra of H2Bz2+, HBz+ and Bz; the corresponding wavelengths of maximal absorption are 247, 273 and 278 nm, and molar absorptivities 1.63 × 104, 1.76 × 104 and 2.26 × 104 1.mole−1.cm−1.  相似文献   

4.
Yao SZ  Shiao J  Nie LH 《Talanta》1987,34(12):983-986
An electrode selective for trimethoprim is based on the ion-pair complex of trimethoprim with silicotungstate, and gives rapid response to change in trimethoprim concentration over the range 3 × 10−5−2 × 10−2 M with a response slope of 51.0 ± 1.5 mV/decade. No significant interferences are caused by sulpha-drugs. The electrode can be used for the potentiometric determination of trimethoprim.  相似文献   

5.
Inam R  Somer G 《Talanta》1998,46(6):1347-1355
The polarographic reduction of lead in the presence of selenite gives rise to an additional peak corresponding to the reduction of lead (Pb) on adsorbed selenium (Se) on mercury at −0.33 V. The selenium and lead content can be determined using this peak by the addition of a known amount of one of these ions first and then the second ion. The linear domain range of lead is 5.0×10−7–2.0×10−5 M and for selenium 5.0×10−7–1.0×10−5 M. Using this method 4.90×10−7 M Se(IV) and 1.47×10−6 M Pb(II) in a synthetic sample could be determined with a relative error of +2.0% and 1.8%, respectively (n=4). A recovery test after acid digestion for a synthetic sample was 97% for selenium and 96.5% for lead. The method was applied to 1 ml of digested blood, and 328±23 μg l−1 Se(IV) and 850±62 μg l−1 Pb(II) could be determined with a 90% (n=5) confidence interval.  相似文献   

6.
A new spectrophotometric flow-injection (FI) method is proposed for the determination of glucose based on the redox reaction of hydroquinone with iron(III). When a glucose solution containing quinone is passed through the immobilized glucose oxidase column introduced in FI system, quinone is reduced to hydroquinone by glucose. In the presence of 1,10-phenanthroline (phen), iron(III) is then quantitatively reduced by hydroquinone to iron(II) followed by the formation of iron(II)-phen complex (λmax=510 nm). An FI peak observed at 510 nm corresponds to the concentration of glucose. The wide dynamic range for glucose was obtained in the range of 1×10−6–1×10−3 mol l−1 at a sampling rate of 24 h−1 and the detection limit (S/N=3) was 5×10−7 mol l−1. Relative standard deviations were 0.78, 0.44 and 0.23% (n=5) for 5×10−6, 5×10−5 and 5×10−4 mol l−1 of glucose, respectively. The proposed method was successfully applied to the determination of glucose in control blood sera, human blood plasma and wine.  相似文献   

7.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

8.
Feng D  Yang P  Yang Z 《Talanta》1991,38(12):1493-1498
Potentiometric stripping analysis was applied to determination of germanium(IV) in 0.2M NH3-NH4Cl (pH 8.4) buffer solution at −1.8 V (vs. Ag/AgCl), with dissolved oxygen or Hg(II) as oxidant. The sensitivity was 8.5 × 10−9M in the presence of 2.0 × 10−5M Hg(II) with plating for 15 min after deaeration for 20 min. Cyclic voltammetry revealed that GE(IV) å Ge at the surface of the mercury-film electrode in a one-step irreversible reduction reaction, and the Ge at the electrode was oxidized by dissolved oxygen in the solution. The presence of complexing agents such as Alizarin Red (ARS), which forms a Ge(IV) complex adsorbed at the electrode, improved the sensitivity by one order of magnitude. The presence of adsorption was revealed by the temperature coefficient, the electrocapillary curve and cyclic voltammetry. Ge-containing samples were analysed by the proposed methods and agreement with the results obtained by other methods was excellent.  相似文献   

9.
The reaction: F + HCl→ HF (v 3) + Cl (1), has been initiated by photolysing F2 using the fourth-harmonic output at 266 nm from a repetitively pulsed Nd: YAG laser By analysing the time-dependence of the HF(3,0) vibrational chemiluminescence, rate constants have been determined at (296 ± 5) K for reaction (1), k1 = (7.0 ± 0.5) × 10−12 cm3 molecule−1 s−1, and for the relaxation of HF(v = 3) by HCl, CO2, N2O, CO, N2 and O2: kHCl = (1.18 ±0.14) × 10−11 kCO2 = (1.04 ± 0. 13) × 10−12, kN2O = (1.41 ± 0.13) × 10−11 kCO = (2.9 ± 0.3) × (10−12, kN2 = (7.1 ± 0.6) × 10−14 and kO2 = (1.9 ± 0.6) × 10−14 cm3molecule−1s−1.  相似文献   

10.
Wang Z  Zhang H  Zhou S  Dong W 《Talanta》2001,53(6):1133-1138
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2×10−9–4.6×10−7 M. The detection limit is 8.0×10−11 M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum.  相似文献   

11.
By designing a novel flow-through electrolytic cell (FEC), bromine was produced near to the surface of the platinum electrode by electrochemical oxidation of acidic KBr. The fast and weak chemiluminescence signal produced by the chemical reaction of the electrogenerated bromine with H2O2 was greatly enhanced by tetracyclines Based on these observations, a new, sensitive and simple electrogenerated chemiluminescence (ECL) method for the determination of tetracyclines was developed. Under the optimum experimental conditions, the calibration graphs are linear over the range 3.0×10−8 to 5.0×10−5 g ml−1 for tetracycline, 2.0×10−7 to 2.4×10−5 g ml−1 for oxytetracycline and 1.0×10−7 to 5.0×10−5 g ml−1 for chlortetracycline. The limits of detection (S/N=3) are 1.0×10−8 g ml−1 for tetracycline, 7.0×10−8 g ml−1 for oxytetracycline and 1.5×10−7 g ml−1 for chlortetracycline. For the determination 5.0×10−7 g ml−1 tetracycline, the relative standard deviation was <5%. The proposed method was used to determine tetracyclines in pharmaceutical formulations.  相似文献   

12.
Pei J  Li XY 《Talanta》2000,51(6):2379-1115
A thin film of mixed-valent CuPtCl6 is deposited on a glassy carbon electrode by continuous cyclic scanning in a solution containing 3×10−3 M CuCl2+3×10−3 M K2PtCl6+1 M KCl in the potential range from 700 to −800 mV. The cyclic voltammetry is used to study the electrochemical behaviors of nitrite on CuPtCl6/GC modified electrode and the electrode displays a good catalytic activity toward the oxidation of nitrite. The effects of the film thickness, pH, the electrode stability and precision have been evaluated. Experiments in flow-injection analysis are performed to characterize the electrode as an amperometric sensor for the detection of nitrite. The modified electrode shows a wide dynamic range, quite a low detection limit and short response time. The linear relationship between the flow-injection peak currents and the concentrations of nitrite is at a range of 1×10−7–2×10−3 M with a detection limit of 5×10−8 M.  相似文献   

13.
Zhou CL  Lu Y  Li XL  Luo CN  Zhang ZW  You JM 《Talanta》1998,46(6):1531-1536
A new method is described for the determination of antimony based on the cathodic adsorptive stripping of Sb(III) complexed with 2′,3,4′,5,7-pentahydroxyflavone(morin) at a static mercury drop electrode (SMDE). The reduction current of the adsorbed antimony complex was measured by 1.5th-order derivative linear-sweep adsorption voltammetry. The peak potential is at −0.51 V (vs. SCE). The effects of various parameters on the response are discussed. The optimized analytical conditions were found to be: supporting electrolyte, chloroacetic acid (0.04 mol/l, pH 2.3); concentration of morin, 5×10−6 mol/l; accumulation potential, −0.25 V (vs. SCE); scan rate, 100 mV/s. The limit of detection and the linear range were 7×10−10 mol/l and 1.0×10−93.0×10−7 mol/l Sb(III) for a 2-min accumulation time, respectively. This method has been applied to the determination of Sb(III) in steel and brass samples and satisfactory results were obtained. The adsorptive voltammetric characteristics and composition of the Sb(III)–morin complex were studied.  相似文献   

14.
Wang Q  Li N 《Talanta》2001,55(6):243-1225
The thiolactic acid (TLA) self-assembled monolayer modified gold electrode (TLA/Au) is demonstrated to catalyze the electrochemical response of norepinephrine (NE) by cyclic voltammetry. A pair of well-defined redox waves were obtained and the calculated standard rate constant (ks) is 5.11×10−3 cm s−1 at the self-assembled electrode. The electrode reaction is a pseudo-reversible process. The peak current and the concentration of NE are a linear relationship in the range of 4.0×10−5–2.0×10−3 mol l−1. The detection limit is 2.0×10−6 mol l−1. By ac impedance spectroscopy the apparent electron transfer rate constant (kapp) of Fe(CN)3−/Fe(CN)4− at the TLA/Au electrode was obtained as 2.5×10−5 cm s−1.  相似文献   

15.
Rate constants for the reactions of OH with CH3CN, CH3CH2CN and CH2=CH-CN have been measured to be 5.86 × 10−13 exp(−1500 ± 250 cal mole−1/RT), 2.69 × 10−13 exp(−1590 ± 350 cal mole−1/RT and 4.04 × 10−12 cm3 molecule−1 s−1, respectively in the temperature range 298–424 K. These results are discussed in terms of the atmospheric lifetimes of nitrfles.  相似文献   

16.
J. Femi Iyun  Ade Adegite 《Polyhedron》1989,8(24):2883-2888
At 25°C, I = 1.0 M (CF3SO3Li++CF3SO3H), [H+] = 0.034–0.274 M and λ = 453 nm, the rate equation for the oxidation of Ti(H2O), 63+ by bromine was found to be: −d/[Br2]T/dt=kK/[Br2][TiIII]/[H+]+K+kK/[Br3][TiIII]/[H++K, where k = 9.2 × 10−3 M −1 s −1 and K = 4.5 × 10−3 M. At [H+] = 1.0 M, [Br] = 0.05–0.4 M, the apparent second-order rate constant decreases as [Br] increases.

The pH-dependence of the oxidation of TiIII-edta by bromine is interpreted in terms of the change in identity of the TiIII-edta species as the pH of the reaction medium changes. The second-order rate constants were fitted using a non-linear least-square computer program with (1/k0edta)2 weighting into an equation of the form: k0edta =k1+k2K1[H+]−1+k3K1K2[H+]−2/1+K1[H+[H+−1+K1K2[H+]−2, with K1 and K2 fixed as earlier determined at 9.55 × 10−3 and 2.29 × 10−9 M, respectively, for the oxidation of bromine. k1=k2=(3.1±0.32)×103M−1s−1 k3=(2.3±0.45)×106N−1s−1.

It is proposed that these electron transfer reactions proceed by univalent changes with the production of Br2.− as a transient intermediate. An outer-sphere mechanism is proposed for these reactions. The homonuclear exchange rate for TiIII-edta+TiIV-edta is estimated at 32 M−1 s−1.  相似文献   


17.
Antigen I/II can be found on streptococcal cell surfaces and is involved in their interaction with salivary proteins. In this paper, we determine the adsorption enthalpies of salivary proteins to Streptococcus mutans LT11 and S. mutans IB03987 with and without antigen I/II, respectively, using isothermal titration calorimetry. In addition, protein adsorption to the cell surfaces was determined spectrophotometrically. S. mutans LT11 with antigen I/II, yielded a much higher, exothermic adsorption enthalpy at pH 6.8 (ranging from −2073 × 10−9 to −31707 × 10−9 μJ per bacterium) when mixed with saliva than did S. mutans IB03987 (−165 × 10−9 to −1107 × 10−9 μJ per bacterium) at all bacterial concentrations studied (5 × 109, 5 × 108, and 5 × 107 ml−1), largest effects per bacterium being observed for the lowest concentration. However, the enthalpy of salivary protein adsorption to S. mutans LT11 became smaller at pH 5.8. Adsorption isotherms for the S. mutans LT11 showed considerable protein adsorption at pH 6.8 (1.2–2.1 mg/m2), that decreased only slightly at pH 5.8 (1.1–1.6 mg/m2), with the largest amount adsorbed at the lowest bacterial concentration. This suggests that the protein(s) in the saliva with the strongest affinity for antigen I/II is (are) readily depleted from saliva. In conclusion, antigen I/II surface proteins on S. mutans play a determinant role in adsorption of salivary proteins through the creation of enthalpically favorable adsorption sites.  相似文献   

18.
Cox JA  Lewinski K 《Talanta》1993,40(12):1911-1915
Either an iridium electrode that was anodically pretreated or a glassy carbon electrode that was coated with a film that contained iridium oxide promoted the oxidation of hydrogen peroxide. With flow injection methodology, linear calibration curves were obtained over the 2 × 10−5 −3.6 × 10−8M range with 0.1M KOH as the carrier. With solutions of pH 11, oxidation occurred at applied potentials of near 0.0 V vs. SCE, which is much lower than potentials needed at bare Pt or glassy carbon. The low overpotential suggests applications to systems where oxidation of other species limits the use of bare electrodes. Cyclic voltammetric studies show that HO2 is the electroactive species and that catalysis rather than mediation promotes the charge transfer. Dissolved oxygen does not interfere with the measurement.  相似文献   

19.
The collisional quenching of electronically excited germanium atoms, Ge[4p2(1S0)], 2.029 eV above the 4p2(3P0) ground state, has been investigated by time-resolved atomic resonance absorption spectroscopy in the ultraviolet at λ = 274.04 nm [4d(1P10) ← 4p2(1S0)]. In contrast to previous investigations using the ‘single-shot mode’ at high energy, Ge(1S0) has been generated by the repetitive pulsed irradiation of Ge(CH3)4 in the presence of excess helium gas and added gases in a slow flow system, kinetically equivalent to a static system. This technique was originally developed for the study of Ge[4p2(1D2)] which had eluded direct quantitative kinetic study until recently. Absolute second-order rate constants obtained using signal averaging techniques from data capture of total digitised atomic decay profiles are reported for the removal of Ge(1S0) with the following gases (kR in cm3 molecule−1 s−1, 300 K): Xe, 7.1 ± 0.4 × 10−13; N2, 4.7 ± 0.6 × 10−12; O2, 3.6 ± 0.9 × 10−11; NO, 1.5 ± 0.3 × 10−11; CO, 3.4 ± 0.5 × 10−12; N2O, 4.5 ± 0.5 × 10−12; CO2, 1.1 ± 0.3 × 10−11; CH4, 1.7 ± 0.2 × 10−11; CF4, 4.8 ± 0.3 × 10−12; SF6, 9.5 ± 1.0 × 10−13; C2H4, 3.3 ± 0.1 × 10−10; C2H2, 2.9 ± 0.2 × 10−10; Ge(CH3)4, 5.4 ± 0.2 × 10−11. The results are compared with previous data for Ge(1S0) derived in the single-shot mode where there is general agreement though with some exceptions which are discussed. The present data are also compared with analogous quenching rate data for the collisional removal of the lower lying Ge[4p2(1D2)] state (0.883 eV), also characterized by signal averaging methods similar to that described here.  相似文献   

20.
Umeh EO  Fadiya OO 《Talanta》1979,26(12):1155-1159
The interference of trace levels of cyanide with the formation of iodo-mercury complexes is made the basis of a method of trace analysis for cyanide. The decrease in absorbance of the iodo-mercury complexes is a linear function of total cyanide concentration up to about 5 × 10−5M in 0.1M sodium hydroxide medium when the iodide and mercury total concentrations are 0.05M and 3 × 10−5M respectively. Several cyano-mercury complexes are formed simultaneously, and quite a large fraction of the cyanide remains uncomplexed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号