首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 875 毫秒
1.
Trace amounts of nickel(II) can function as a trigger (=reaction initiator) in an autocatalytic reaction with the sodium sulfite/hydrogen peroxide system. Based on this finding, sub-μg L−1 levels of nickel(II) were determined by a time measurement using the autocatalytic reaction. The detection range using the above method was 10−9–10−5 M, the detection limit (3σ) was 8.1 × 10−10 M (0.047 μg L−1), and the relative standard deviation was 2.66% at nickel(II) concentration of 10−7 M (n = 7). This method was applied to length detection-flow injection analysis. The detection range for the flow injection analysis was 2 × 10−9–2 × 10−3 M. The detection limit (3σ) was 1.4 × 10−9 M (0.082 μg L−1), and the relative standard deviation was 1.86 at initial nickel(II) concentration of 10−6 M (n = 7).  相似文献   

2.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   

3.
van Staden JF  Stefan RI 《Talanta》1999,49(5):1472-1022
An on-line automated system for the simultaneous flow injection determination of calcium and fluoride in natural and borehole water with conventional calcium-selective and fluoride-selective membrane electrodes as sensors in series is described. Samples (30 μl) are injected into a TISAB II (pH=5.50) carrier solution as an ionic strength adjustment buffer. The sample-buffer zone formed is first channeled to a fluoride-selective membrane electrode and then via the calcium-selective membrane electrode to the reference electrodes. The system is suitable for the simultaneous on-site monitoring of calcium (linear range 10−5–10−2 mol l−1 detection limit 1.94×10−6 mol l−1 recovery 99.22%, RSD<0.5%) and fluoride (linear range 10−5–10−2 mol l−1 detection limit 4.83×10−6 mol l−1 recovery 98.63%, RSD=0.3%) at a sampling rate of 60 samples h−1.  相似文献   

4.
A new spectrophotometric flow-injection (FI) method is proposed for the determination of glucose based on the redox reaction of hydroquinone with iron(III). When a glucose solution containing quinone is passed through the immobilized glucose oxidase column introduced in FI system, quinone is reduced to hydroquinone by glucose. In the presence of 1,10-phenanthroline (phen), iron(III) is then quantitatively reduced by hydroquinone to iron(II) followed by the formation of iron(II)-phen complex (λmax=510 nm). An FI peak observed at 510 nm corresponds to the concentration of glucose. The wide dynamic range for glucose was obtained in the range of 1×10−6–1×10−3 mol l−1 at a sampling rate of 24 h−1 and the detection limit (S/N=3) was 5×10−7 mol l−1. Relative standard deviations were 0.78, 0.44 and 0.23% (n=5) for 5×10−6, 5×10−5 and 5×10−4 mol l−1 of glucose, respectively. The proposed method was successfully applied to the determination of glucose in control blood sera, human blood plasma and wine.  相似文献   

5.
Fenoterol and salbutamol were determined by electrogenerated chemiluminescence (ECL) coupled with flow injection analysis (FIA), using Ru(bpy)32+ as the luminescent substance. Fenoterol and salbutamol oxidize together with the ruthenium 2,2-bipyridyl at a platinum electrode, which leads to an increase in the luminescent intensity, and this increase is proportional to the analyte concentration. For fenoterol a linear calibration curve within the range from 1.0 × 10−5 to 1.0 × 10−4 mol l−1 was obtained with a correlation coefficient of 0.998 (n = 5) and for salbutamol the linear analytical curve was also obtained in this range with a correlation coefficient of 0.995 (n = 5). The relative standard deviation was estimated as ≤2.5% for 3 × 10−5 mol l−1 for fenoterol solution and as ≤1.3% for 5.0 × 10−5 mol l−1 salbutamol solution for 15 successive injections. The limit of detection for fenoterol was 2.4 × 10−7 mol l−1 and for salbutamol was 4.0 × 10−7 mol l−1. Fenoterol and salbutamol were successfully determined in drug tablets and the soluble components of the matrix did not interfere in the luminescent emission. The results obtained using the luminescent methodology were not statistically different from those obtained by UV-spectrophotometry at 95% confidence level.  相似文献   

6.
Formation constants for recrystallized thymol blue were determined in water, using the SQUAD and SUPERQUAD programs. The best model correlating spectrophotometric, potentiometric and conductimetric data was fitted with the dissociation of HL=L2−+H+−log K=8.918±0.070 and H3L2=2L2−+3H+−log K=29.806±0.133 with the SUPERQUAD program at variable low ionic strength (1.5×10−4–3.0×10−4 M); and HL=L2−+H+−log K=8.9±0.000, H3L2 =2L2−+3H+−log K=30.730±0.032, H4L2=2L2−+4H+−log K=32.106±0.033 with SQUAD at 1.1 M ionic strength.  相似文献   

7.
Sakai T  Liu X  Maeda Y 《Talanta》1999,49(5):913-1001
A simple, sensitive and rapid spectrophotometric method for the determination of neostigmine by flow injection analysis (FIA) coupled with an ion associate extraction has been developed. The three-line manifold was assembled. Neostigmine(200 μl) was injected into a distilled water stream and the pH was adjusted to 10 with a borate–phosphate buffer solution. Then, the stream was mixed with the ion-pairing tetrabromophenolphthalein ethylester (TBPEH)-1,2-dichloroethane solution. After phase separation with a double membrane phase separator, absorbance was measured at 610 nm. A linear calibration graph was obtained between 1×10−7 mol l−1 and 5×10−7 mol l−1 of neostigmine. Up to 48 samples h−1 could be processed with a relative standard deviation (R.S.D.) of 0.5% (n=5) for 4×10−7 mol l−1 neostigmine. The proposed system was applied to the simple, reproducible and rapid determination of neostigmine in commercial pharmaceuticals.  相似文献   

8.
Wang Q  Li N 《Talanta》2001,55(6):243-1225
The thiolactic acid (TLA) self-assembled monolayer modified gold electrode (TLA/Au) is demonstrated to catalyze the electrochemical response of norepinephrine (NE) by cyclic voltammetry. A pair of well-defined redox waves were obtained and the calculated standard rate constant (ks) is 5.11×10−3 cm s−1 at the self-assembled electrode. The electrode reaction is a pseudo-reversible process. The peak current and the concentration of NE are a linear relationship in the range of 4.0×10−5–2.0×10−3 mol l−1. The detection limit is 2.0×10−6 mol l−1. By ac impedance spectroscopy the apparent electron transfer rate constant (kapp) of Fe(CN)3−/Fe(CN)4− at the TLA/Au electrode was obtained as 2.5×10−5 cm s−1.  相似文献   

9.
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH4OH+0.05% w/v Triton X-100®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO3)2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1−1 Se, corresponding to 30 μg l−1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l−1, with a mean value of 114±22 μg l−1.  相似文献   

10.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

11.
Chen J  Xiao S  Wu X  Fang K  Liu W 《Talanta》2005,67(5):992-996
Cloud point extraction (CPE) has been used for the pre-concentration of lead, after the formation of a complex with 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (5-Br-PADAP), and later analysis by graphite furnace atomic absorption spectrometry (GFAAS) using octylphenoxypolyethoxyethanol (TritonX-114) as surfactant. The chemical variables affecting the separation phase were optimized. Separation of the two phases was accomplished by centrifugation for 15 min at 4000 rpm. Under the optimum conditions i.e., pH 8.0, cloud point temperature 40 °C, [5-Br-PADAP] = 2.5 × 10−5 mol l−1, [Triton X-114] = 0.05%, added methanol volume = 0.15 ml, pre-concentration of only 10 ml sample permitted an enhancement factor of 50-fold. The lower limit of detection (LOD) obtained under the optimal conditions was 0.08 μg l−1. The precision for 10 replicate determinations at 5 μg l−1 Pb was 2.8% relative standard deviation (R.S.D.). The calibration graph using the pre-concentration system for lead was linear with a correlation coefficient of 0.9984 at levels near the detection limits up to at least 30 μg l−1. The method was successfully applied to the determination of lead in water samples.  相似文献   

12.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


13.
The cathodic adsorptive electrochemical behavior of guanine in the presence of some metal ions at the static mercury drop electrode was investigated. A 1.0×10−3 mol l−1 NaOH or a 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 solutions were used as supporting electrolytes. The reduction peak potential for guanine was found to be around −0.15 V, which is very close to the mercury reduction wave. A new peak appears at −0.60 V in the presence of copper or at −1.05 V in the presence of zinc. A square wave voltammetric procedure for electroanalytical determination of guanine in 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 containing 1.6×10−5 mol l−1of copper ions, was developed. An accumulation potential of −0.15 V during 270 s for the prior adsorption of guanine at the electrode surface was used. The response of the system was found to be linear in the range of guanine concentration from 6.62×10−8 to 1.32×10−7 mol l−1 and the detection limit was 7.0×10−9 mol l−1. The influence of DNA bases such as adenine, cytosine and thymine was also examined. Cyclic voltammetry was used to characterize the interfacial and redox mechanism.  相似文献   

14.
Agnihotri NK  Singh VK  Singh HB 《Talanta》1993,40(12):1851-1859
Derivative photometric methods for trace analysis of Th(IV) and UO2(II), and their simultaneous determination in mixtures using 5,8-dihydroxy-1,4-naphthoquinone in a micellar medium are reported. Molar absorptivity and Sandell's sensitivity of 1:2 Th(IV) and 1:1 UO2(II) complexes at their λmax, 614.5 nm and 637.0 nm are, 1.19 × 104 1/mol/cm and 1.12 × 104 1/mol/cm and 1.95 × 10−2 μg/cm2 and 2.13 × 10−2 μg/cm2 μg/cm2, respectively. Calibration graph is linear over the range 9.28 × 10−2−18.56 μg/ml of Th(IV) and 9.52 × 10−2−19.04 μg/ml of UO2(II). Though presence of Th(IV) and UO2(II) causes interference in each others determination, 9.28 × 10−1−9.28 μg/ml Th(IV) and 9.52 × 10−1−9.52 μg/ml UO2(II) when present together, can be simultaneously determined using derivative spectra.  相似文献   

15.
Zareh MM  Ghoneim AK  Abd El-Aziz MH 《Talanta》2001,54(6):1049-1057
The lipophilic ammonium salt of 1-pyrrolidine dicarbodithioic acid (PCDT)[I] was introduced as a selective ionophore for a sensitive Pb-ion selective electrode. Also, the effect of immobilization of 18-crown-6 (CW), into the above membrane, on the electrode performance was discussed. The slope of the PCDT-based [I] electrode was (26–30 mV decade−1), while it was (29-30 mV decade−1) for (PCDT+CW)-based [II] electrode according to the doping time. The linear concentration ranges were (1×10−6–1×10−1 M) and (5×10−5–1×10−1 M) for electrode types [I] and [II] after one-day doping. The working pH ranges were (5.0–10.0) and (7.0–10.0) for electrode types [I] and [II], respectively. Most of the common cations were tested for the evaluation of the electrode selectivity with correlation to the ionic radii of the tested cations. Among them only Na+, Ag+ and Fe3+ were the real interference. Application of using the electrode for the determination of lead in lubrication oil samples was performed with RSD (0.86–1.03%). The obtained results were compared to those of an atomic absorption spectrophotometric method.  相似文献   

16.
Saran L  Cavalheiro E  Neves EA 《Talanta》1995,42(12):2027-2032
The highly neutralized ethylenediaminetetraacetate (EDTA) titrant (95–99% as Y4− anion) precipitates with Ag+ cations to form the Ag4Y species, in aqueous medium, which is well characterized from conductometric titration, thermal analysis and potentiometric titration of the silver content of the solid. The precipitate dissolves in excess Y4− to form a complex, AgY3−. Equilibrium studies at 25°C and ionic strength 0.50 M (NaNO3) have shown from solubility and potentiometric measurements that the formation constant (95% confidence level) β1 = (1.93 ± 0.07) × 105 M−1 and the solubility products are KS0 = [Ag +]4[Y4−] = (9.0 ± 0.4) × 10−18 M5 and KS1 = [Ag +]3[AgY3−] = (1.74 ± 0.08) × 10−12 M4. The presence of Na+, rather than ionic strength, markedly affects the equilibrium; the data at ionic strength 0.10 M are: β1 = (1.19 ± 0.03) × 106 M−1, KS0 = (1.6 ± 0.4) × 10−19 M5 and KS1 = (1.9 ± 0.5) × 10−13 M4; at ionic strength tending to zero; β1 = (1.82 ± 0.05) × 107 M−1, KS0 = (2.6 ± 0.8) × 10−22 M5 and KS1 = (5 ± 1) × 10−15 M4. The intrinsic solubility is 2.03 mM silver (I) in 0.50 M NaNO3. Well-defined potentiometric titration curves can be taken in the range 1–2 mM with the Ag indicator electrode. Thermal analysis revealed from differential scanning calorimetry a sharp exothermic peak at 142°C; thermal gravimetry/differential thermal gravimetry has shown mass loss due to silver formation and a brown residue, a water-soluble polymeric acid (decomposition range 135–157°C), tending to pure silver at 600°C, consistent with the original Ag4Y salt.  相似文献   

17.
Zeng B  Yang Y  Ding X  Zhao F 《Talanta》2003,61(6):819-827
A novel method for the determination of perphenazine has been developed. The method is based on the accumulation of perphenazine at a gold electrode modified with decanethiol (DEC) self-assembled monolayer (SAM) and its oxidation at about 0.6 V (vs. saturated calomel electrode (SCE)). Because some coexistent electroactives were blocked and perphenazine was selectively accumulated by the SAM, the electrode exhibited good selectivity and sensitivity. Various conditions were optimized for practical application. Under the selected conditions (i.e. 0.05 M pH 10 sodium borate buffer, accumulation time: 120 s, accumulation potential: −0.4 V, scan rate: 100 mV s−1), the anodic stripping peak current was linear to perphenazine concentration in the ranges of 6×10−9–5×l0−7 and 5×10−7–5×10−6 M with correlation coefficients of 0.998 and 0.995, respectively. For a 1.0×10−6 M perphenazine solution, the relative standard deviation of peak height was 2.3% (n=8). This method was applied to the determination of perphenazine in some drugs and the recovery was 92–101%. In addition, it was found that in the presence of perphenazine, the SAM structure changed a little and more needle holes appeared. However, the SAM could recover the original form when perphenazine and its redox product were removed from the monolayer by repeatedly cycling the electrode in a blank solution for a minute. The modified electrode was characterized by alternating current impedance and electrochemical probe.  相似文献   

18.
Plasticized poly(vinyl chloride) (PVC) membranes of different compositions were tested for use in the construction of potentiometric flow detectors for triiodide. A membrane with a 2:1 (w/w) 2-nitrophenyl octyl ether to PVC ratio was selected. The influence of thiosulphate in the carrier solution composition and of the flow-injection variables on the determination of triiodide was studied. In the selected conditions, a linear relationship between peak height and log[I3] was obtained between 5 × 10−6 and 1 × 10−4 mol l−1 triiodide. Peak height relative standard deviations for 2 × 10−5 and 1 × 10−4 mol l−1 triiodide were ±0.4 and ±1.8%, respectively, and sampling frequency was 80 samples per hour. The method proposed was applied satisfactorily to the iodometric determination of different chlorine-containing disinfectants, among them trichloroisocyanuric acid and dichloroisocyanurate in several types of commercial sample.  相似文献   

19.
Sultan SM  Hassan YA  Abulkibash AM 《Talanta》2003,59(6):1073-1080
For the first time, promethazine hydrochloride chemiluminescence emission was monitored. The paper describes a new, specific and highly sensitive flow injection (FI) method for the determination of promethazine hydrochloride using both a peristaltic and a syringe pump. The method was based on the chemiluminescence emission intensity produced as a result of its oxidation reaction with permanganate in sulfuric acid medium. Reaction variables were thoroughly investigated employing chemometrical methods with few number of experiments. The optimum system and chemical conditions were 2.1519×10−4 mol l−1 permanganate in 0.01 mol l−1 sulfuric acid when operating the peristaltic pump at a flow rate of 45 μl s−1 and injecting the drug by a syringe pump operated at a speed of 40 μl s−1. The method was found to be applicable in the concentration range of promethazine hydrochloride between 1.558×10−5 and 1.8697×10−3 mol l−1 with a linear calibration plot of 0.992 correlation coefficient and the following equation: I=92.74+0.08048C. The method adopted proved to be highly suitable for the assay of promethazine hydrochloride in drug formulations without fear of interferences in dosage form.  相似文献   

20.
UV spectra and kinetics for the reactions of alkyl and alkylperoxy radicals from methyl tert-butyl ether (MTBE) were studied in 1 atm of SF6 by the pulse radiolysis-UV absorption technique. UV spectra for the radical mixtures were quantified from 215 to 340 nm. At 240 nm. σR = (2.6 ± 0.4) × 10−18 cm2 molecule−1 and σRO2 = (4.1 ± 0.6) × 10−18 cm2 molecule−1 (base e). The rate constant for the self-reaction of the alkyl radicals is (2.5 ± 1.1) × 10−11 cm3 molecule−1 s−1. The rate constants for reaction of the alkyl radicals with molecular oxygen and the alkylperoxy radicals with NO and NO2 are (9.1 ± 1.5) × 10−13, (4.3 ± 1.6) × 10−12 and (1.2 ± 0.3) × 10−11 cm3 molecule−1 s−1, respectively. The rate constants given above refer to reaction at the tert-butyl side of the molecule.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号