首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report a simple and rapid method for the deposition of amorphous silica onto a gold surface. The method is based on the ability of lysozyme to mediate the formation of silica nanoparticles. A monolayer of lysozyme is deposited via non-specific binding to gold. The lysozyme then mediates the self-assembled formation of a silica monolayer. The silica formation described herein occurs on a surface plasmon resonance (SPR) gold surface and is characterized by SPR spectroscopy. The silica layer significantly increases the surface area compared to the gold substrate and is directly compatible with a detection system. The maximum surface concentration of lysozyme was found to be a monolayer of 2.6 ng/mm(2) which allowed the deposition of a silica layer of a further 2 ng/mm(2). For additional surface functionalization, the silica was also demonstrated to be a suitable matrix for immobilization of biomolecules. The encapsulation of organophosphate hydrolase (OPH) was demonstrated as a model system. The silica forms at ambient conditions in a reaction that allows the encapsulation of enzymes directly during silica formation. OPH was successfully encapsulated within the silica particles and a detection limit for the substrate, paraoxon, using the surface-encapsulated enzyme was found to be 20 microM.  相似文献   

2.
Cyclic voltammetry (CV) has been combined with surface plasmon resonance (SPR) for probing electrochemical deposition and redox‐initiated film reorganization and conformational changes. However, the varying potential during CV scans leads to unwanted SPR background changes and complicates interpretation of SPR signals. In this work, we show that, when SPR is coupled with CV, the background correction for underpotential deposition of copper and electropolymerization of aniline is either inaccurate or difficult to perform. For accurate thickness measurements of electrodeposited films, potential‐step (PS) chronoamperometry is a method of choice to combine with SPR. The theory that interprets double‐layer charging is used to explain the advantage of PS chronoamperometry over CV in quantifying the thickness of electrodeposited thin films. The influence of the double‐layer charging on the potential‐induced SPR signal change was analyzed, and the results were used to optimize experimental parameters for PS‐SPR. Overall, PS‐SPR is easier to operate, simpler in data interpretation, and more accurate for the film thickness measurement.  相似文献   

3.
Bilayered silver/gold films (gold deposited on top of the silver film) were used as substrates for electrochemical surface plasmon resonance spectroscopy (EC-SPR). EC-SPR responses of electrochemical deposition/stripping of copper and redox-induced conformation changes of cytochrome c immobilized onto self-assembled monolayers preformed at these substrates were measured. Influence of the Ag layer thickness and the double-layer capacitance on the EC-SPR behavior was investigated. The results demonstrated that the bilayered Ag/Au metal films produce a sharper SPR dip profile than pure Au films and retain the high chemical stability of Au films. Contrary to the result by the Fresnel calculation that predicts a greater fraction of Ag in the bilayered film should result in a greater signal-to-noise ratio, the EC-SPR sensitivity is dependent on both the Ag/Au thickness ratio and the chemical modification of the surface. Factors affecting the overall SPR sensitivity at the bilayered films, such as the film morphology, potential-induced excess surface charges, and the adsorbate layer were investigated. Forming a compact adsorbate layer at the bilayered film diminishes the effect of potential-induce excess surface charges on the SPR signal and improves the overall EC-SPR sensitivity. For the case of redox-induced conformation changes of cytochrome c, the SPR signal obtained at the bilayered silver/gold film is 2.7 times as high as that at a pure gold film.  相似文献   

4.
The use of surface plasmon resonance (SPR) as a nondestructive, nonerasing readout of the isomerization state of a photochromic dithienylethene covalently linked to a chemically modified gold surface was investigated. Four different binding layers were examined: 11-mercaptoundecanol (MUO), an amine-modified 11-mercaptoundecanol (MUO-NH2), dextran, and an amine-modified dextran. The binding of dithienylethene to the modified gold surface and photoisomerization of the photochrome in the bound state were established by FTIR. Solvent effects were measured for every layer tested using ethanol and hexanes. In general, large, easily measurable SPR signal changes could be detected under conditions where photoisomerization of the dithienylethene photochrome was not quenched by the gold plasmon, establishing SPR as a viable form of readout for potential dithienylethene-based optical data storage or processing devices. Dextran-bound photochrome in ethanol exhibited the largest SPR response upon photoisomerization, but is more prone to time-dependent fluctuations resulting from swelling of the dextran layer (caused by slow diffusion of the solvent) than the other layers. Large responses are also provided by MUO-NH2 and MUO, and the signal is much more stable than that for dextran.  相似文献   

5.
A slab-type optical waveguide (s_OWG)-based microfluidic SPR measurement system for bisphenol A was developed. This s_OWG possesses consecutive parallel gold and silver deposition bands in the line of plasmon flow, allowing two individual SPR signals to be independently obtained as a result of the difference in resonant reflection spectra of these metals. As a molecular recognition element, molecularly imprinted polymer nanoparticles (MIP-Np) were employed and immobilized on the surface of each of the gold and silver deposition bands. The resonant reflection spectra were measured on the MIP-Np-immobilized consecutive parallel gold and silver deposition bands coexistent with BPA-AuNp. The Ag-based SPR spectra showed a red shift (0.7 nm) when free BPA (0.1 mM) was passed over the BPA-AuNp/immobilized MIP-Np complexes formed on the s_OWG, unlike the case for the Au deposition band, while a large excess of BPA induced a blue shift due to the competitive desorption of BPA-AuNp from the immobilized MIP-Np on the s_OWG. By using the proposed detection system, binding events of other small molecules could be monitored in conjunction with the use of MIP-Np and labeled-AuNp.  相似文献   

6.
The kinetics of the adsorption of metal ions onto a thiolated surface and the selective and quantitative sensing of metal ions were explored using surface plasmon resonance (SPR) spectroscopy. The target metal ion was an aqueous solution of Pt2+ and a thin-gold-film-coated glass substrate was modified with 1,6-hexanedithiol (HDT) as a selective sensing layer. SPR spectroscopy was used to examine the kinetics of metal ion adsorption by means of the change in SPR angle. The selectivity of the thiolated surface for Pt2+ over other divalent metal ions such as Cu2+, Ni2+, and Cd2+ was evident by the time-resolved SPR measurement. SPR angle shift, deltatheta(SPR), was found to increase logarithmically with increasing concentration of Pt2+ in the range of 1.0 x 10(-5)-1.0 mM. The rate of Pt2+ adsorption on HDT observed at both 0.1 and 1 mM Pt2+ accelerates until the surface coverage reaches approximately 17%, after which the adsorption profile follows Langmuirian behavior with the surface coverage. The experimental data indicated that heavy metal ions were adsorbed to the hydrophobic thiolated surface by a cooperative mechanism. A mixed self-assembled monolayer (SAM) composed of HDT and 11-mercaptoundecanoic acid was used to reduce the hydrophobicity of the thiol-functionalized surface. The addition of hydrophilic groups to the surface enhanced the rate of adsorption of Pt2+ onto the surface. The findings show that the adsorption of metal ions is strongly dependent upon the hydrophilicity/hydrophobicity of the surface and that the technique represents an easy method for analyzing the adsorption of metal ions to a functionalized surface by combining SPR spectroscopy with a SAM modification.  相似文献   

7.
We demonstrate the quantitative characterization of DNA-DNA and DNA-drug interactions by angle-resolved surface plasmon resonance (SPR) imaging. Combining the angle-scanning capabilities of traditional SPR with the spatial definition capabilities of imaging, we directly measure DNA and drug surface coverages and kinetics simultaneously for multiple patterned spots. We find excellent agreement of DNA-DNA hybridization kinetics and thermodynamics measured by both the imaging system and traditional SPR. Instrument response and sensitivity is further demonstrated by successful measurement of association and dissociation kinetics of actinomycin-D binding to a low-density doubled-stranded DNA binding sequence. Without independent calibration, analysis of angle-resolved SPR imaging data yields 2.9 +/- 0.1 drugs per duplex at saturation coverage, consistent with all available duplex binding sites being occupied.  相似文献   

8.
Monolayers of metal complexes were covalently attached to the surface of lamellar SPR interfaces (Ti/Ag/a-Si(0.63)C(0.37)) for binding histidine-tagged peptides with a controlled molecular orientation. The method is based on the activation of surface acid groups with N-hydroxysuccinimide (NHS), followed by an amidation reaction with (S)-N-(5-amino-1-carboxypentyl)iminodiacetic acid (NTA). FTIR and X-ray photoelectron spectroscopy (XPS) were used to characterize each surface modification step. The NTA modified SPR interface effectively chelated Cu(2+) ions. Once loaded with metal ions, the modified SPR interface was able to bind specifically to histidine-tagged peptides. The binding process was followed by surface plasmon resonance (SPR) in a droplet based configuration. The Cu(2+)-NTA modified interface showed protein loading comparable to commercially available NTA chips based on dextran chemistry and can thus be regarded as an interesting alternative. The sensor interface can be reused several times due to the easy regeneration step using ethylenediaminetetraacetic acid (EDTA) treatment.  相似文献   

9.
We report a multichannel surface plasmon resonance (SPR) sensor for detection of thrombin via DNA aptamers immobilized on the SPR sensor surface. A detailed investigation of the effect of the immobilisation method on the interaction between thrombin and DNA aptamers is presented. Three basic approaches to the immobilisation of aptamers on the surface of the SPR sensor are examined: (i) immobilisation based on chemisorption of aptamers modified with SH groups, (ii) immobilisation of biotin-tagged aptamers via previously immobilized avidin, neutravidin or streptavidin molecular linkers, and (iii) immobilisation employing dendrimers as a support layer for subsequent immobilisation of aptamers. A level of nonspecific binding of thrombin to immobilized human serum albumin (HSA) for each of the immobilisation methods is determined. Immobilisation of aptamers by means of the streptavidin–biotin system yields the best results both in terms of sensor specificity and sensitivity.  相似文献   

10.
The function of microcontact printed protein was investigated using surface plasmon resonance (SPR) imaging, X-ray photoelectron spectroscopy spectroscopy (XPS), and XPS imaging. We chose to analyze a model protein system, the binding of an antibody from solution to a microcontact printed protein antigen immobilized to a gold surface. SPR imaging experiments indicated that the microcontact printed protein antigen was less homogeneous, had increased nonspecific binding, and bound less antibody than substrates to which the protein antigen had been physically adsorbed. SPR images of substrates contacted with a poly(dimethylsiloxane) stamp inked with buffer alone (i.e., no protein) revealed that significant amounts of silicone oligomer were transferred to the surface. The transfer of the silicone oligomer was not homogeneous, and the oligomer nonspecifically bound protein (BSA and IgG) from solution. XPS spectroscopy and imaging were used to quantify the amount of silicon (due to the presence of silicone oligomer), as well as the amounts of other elements, transferred to the surface. The results suggest that the silicone oligomer introduced by the printing process reduces the overall binding capacity of the microcontact-printed protein compared to physically adsorbed protein.  相似文献   

11.
Electrochemistry and electrochemical surface plasmon resonance (SPR) spectroscopy have been applied to study the electrochemical deposition and the redox transition of poly(4-nitro-1,2-phenylenediamine) (P4NoPD) on gold disk. It was shown that SPR can be the signal transducer for the different redox states of P4NoPD. Using a model biomolecular system, involving streptavidin, biotinylated DNA, and its complementary target DNA, it was found that the presence of nitro groups in P4NoPD allows the biorecognition events to be modulated by voltages. There is minimal nonspecific binding of biomolecules on oxidized (+0.2 V) or as-prepared P4NoPD, and binding occurs more significantly on the reduced P4NoPD (-0.2 to -0.6 V) with the presence of amine groups. The electrochemical deposition of P4NoPD film was also conducted on boron-doped diamond (BDD) electrode. The stability of the reduced P4NoPD film on gold and BDD was comparatively evaluated by electrochemical impedance spectroscopy (EIS). The result showed that BDD allows the electrochemical reduction of the P4NoPD film at wider cathodic limits than gold.  相似文献   

12.
We report the multiplexed, simultaneous analysis of antigen–antibody interactions that involve human immunoglobulin G (IgG) on a gold substrate by the surface plasmon resonance imaging method. A multichannel, microfluidic chip was fabricated from poly(dimethylsiloxane) (PDMS) to selectively functionalize the surface and deliver the analyte solutions. The sensing interface was constructed using avidin as a linker layer between the surface-bound biotinylated bovine serum albumin and biotinylated anti-human IgG antibodies. Four mouse anti-human IgG antibodies were selected for evaluation and the screening was achieved by simultaneously monitoring protein–protein interactions under identical conditions. Antibody–antigen binding affinities towards human immunoglobulin were quantitatively compared by employing Langmuir adsorption isotherms for the analysis of SPRi responses obtained under equilibrium conditions. We were able to identify two IgG samples with higher affinities towards the target, and the determined binding kinetics falls within the typical range of values reported in the literature. Direct measurement of proteins in serum samples by SPR imaging was achieved by developing methods to minimize nonspecific adsorption onto the avidin-functionalized surface, and a limit of detection (LOD) of 6.7 nM IgG was obtained for the treated serum samples. The combination of SPR imaging and multichannel PDMS chips offers convenience and flexibility for sensitive and label-free measurement of protein–protein interactions in complex conditions and enables high-throughput screening of pharmaceutically significant molecules. Figure Microchannel SPR imaging for protein–protein interactions  相似文献   

13.
Data on the strength of coatings based on noble metals (Pt, Au) deposited onto PET films by the method of ionic plasma sputtering are analyzed. In addition to precipitation of the metal, this mode of deposition is accompanied by modification of the surface polymer layer due to its interaction with plasma. As a result, a complex three-layered structure near the polymer surface forms. A new method for estimating the strength of coatings deposited onto polymer supports is advanced. This method makes it possible to analyze stress-strain characteristics of the three-layered systems that emerge owing to deposition of nanoscale layers of noble metals on polymer films via ionic plasma sputtering. The proposed relationships are in fair agreement with the experimental data.  相似文献   

14.
Small molecules are difficult to detect by conventional surface plasmon resonance (SPR) spectroscopy due to the fact that the changes in the refractive index resulted from the binding process of small biomolecules are quite small. Here, we report a simple and effective method to detect small biomolecule using SPR spectroscopy and electrochemistry by catalyzed deposition of metal ions on SPR gold film. As an example, the ascorbic acid-mediated deposition of Ag on gold film was monitored by in situ SPR spectrum. The deposition of Ag atom on gold film resulted in an obvious decrease of depth in SPR angular scan curves of reflectance intensity and minimum reflectivity angle. The depth change of the SPR reflectance intensity and minimum reflectivity angle curves mainly relied on the amount of Ag atom deposited on gold film that can be controlled by the concentration of ascorbic acid. By monitoring the deposition of Ag atom on gold film, ascorbic acid was detected in the concentration range of 2 × 10−5 M to 1 ×  10−3 M. After each of detections, the SPR sensor surface was completely regenerated by a potential step that stripped off the Ag atom. Furthermore, the regeneration process of the sensor surface provides the feasibility for detecting the concentration of ascorbic acid by electrochemical method.  相似文献   

15.
The characteristics of a surface plasmon resonance (SPR) sensor prepared by coating a metal film evaporated on a prism with a polymer film containing tetra-n-butyl thiuram disulfide (TBTDS) were studied. The differences in the sensitivity, selectivity, and detection limit for a Zn2+ ion of the SPR sensor were reported as a function of the thickness of the polymer film, the kind of a metal film, and the kind of a polymer film. The thinner was the polymer film, the higher was the sensitivity, and the lower was the detection limit. The Ag film gave to the SPR sensor higher sensitivity than the Au film. TBTDS contained in the poly(vinyl chloride) (PVC) film slightly improved the selectivity toward the Zn2+ ion. A non-conditioned poly(methyl methacrylate) (PMMA) film containing TBTDS gave a lower detection limit of 1.0 x 10(-6) mol/l, which is similar to that obtained by using an ion selective electrode (ISE) method, than the PVC film. The PVC film, however, gave higher concentration resolution than the PMMA film.  相似文献   

16.
核-壳结构P(AM-co-MAA)-W-Ag复合微球的制备   总被引:1,自引:0,他引:1  
以丙烯酰胺(acrylamide, AM)和甲基丙烯酸(methacrylic acid, MAA)的共聚微凝胶(P(AM-co-MAA))为模板, 通过离心沉积法将钨粉沉积于高分子微凝胶表面, 得到具有核-壳结构的P(AM-co-MAA)-W复合微球; 再以经聚乙烯基吡咯烷酮(PVP)修饰的P(AM-co-MAA)-W复合微球为模板, 在硝酸银溶液中充分溶胀后, 通过向反相悬浮体系中缓慢通入氨气, 制备得到了具有核-壳结构的P(AM-co-MAA)-W-Ag双金属复合微球材料. 实验发现, 通过改变制备过程中AgNO3的初始浓度和PVP的用量等条件, 可以改变复合微球表面银的沉积量; 并结合实验结果初步提出了银的形成机理, 即PVP的存在, 不仅可以作为稳定剂固定Ag+离子, 同时可以作为还原剂促进Ag+还原为Ag的反应.  相似文献   

17.
We report here on the fabrication and characterization of stable thin films of amorphous silica (SiO(x)) deposited on glass slides coated with a 5 nm adhesion layer of titanium and 50 nm of gold, using the plasma-enhanced chemical vapor deposition (PECVD) technique. The resulting surfaces were characterized using atomic force microscopy (AFM), ellipsometry, contact angle measurements, and surface plasmon resonance (SPR). AFM analysis indicates that homogeneous films of silica with low roughness were formed on the gold surface. The deposited silica films showed excellent stability in different solvents and in piranha solution. There was no significant variation in the thickness or in the SPR signal after these harsh treatments. The Au/SiO(x) interfaces were investigated for their potential applications as new surface plasmon resonance sensor chips. Silica films with thicknesses up to 40 nm allowed visualization of the surface plasmon effect, while thicker films resulted in the loss of the SPR characteristics. SPR allowed further the determination of the silica thickness and was compared to ellipsometric results. Chemical treatment of the SiO(x) film with piranha solution led to the generation of silanol surface groups that have been coupled with a trichlorosilane.  相似文献   

18.
The structure of the surface layer in polymers (LDPE and PET) decorated with a thin metal (gold and platinum) layer was studied after their deformation under different conditions. It was found that relatively thick coatings debonded from the polymer substrate during tensile drawing. Debonding was observed at low tensile strains (below 20–30%). During the further drawing of a polymer, a regular microrelief typical of deformable “rigid coating on a soft substrate” systems appeared on its surface. This phenomenon is explained by the fact that the debonding metal coating uncovers not the surface of the pure polymer but a certain modified layer, which has a higher elastic modulus than the pure polymer. The formation of this layer is associated with the inclusion of metal atoms into the polymer during the metal decoration by plasma immersion ion deposition. As a result of this inclusion, a modified layer, which has a higher glass transition temperature, a higher elastic modulus, and other mechanical properties, is formed between the coating and the polymer.  相似文献   

19.
This paper details the first use of a self-folding deep cavitand on a gold surface. A sulfide-footed deep, self-folding cavitand has been synthesized, and its attachment to a cleaned gold surface studied by electrochemical and SPR methods. Complete monolayer formation is possible if the cavitand folding is templated by noncovalent binding of choline or by addition of space-filling thiols to cover any gaps in the cavitand adsorption layer. The cavitand is capable of binding trimethylammonium-tagged guests from an aqueous medium and can be deposited in 2 × 2 microarrays on the surface for characterization by SPR imaging techniques. When biotin-labeled guests are used, the cavitand:guest construct can recognize and immobilize streptavidin proteins from aqueous solution, acting as an effective supramolecular biosensor for monitoring protein recognition.  相似文献   

20.
Luo Y  Yu F  Zare RN 《Lab on a chip》2008,8(5):694-700
We have designed and fabricated a polydimethylsiloxane (PDMS) microfluidic device containing an array of gold spots onto which antigens or antibodies of interest can be attached. We use surface plasmon resonance (SPR) imaging to monitor the antibody-antigen recognition and binding events. This combination offers two significant advantages: (1) the microfluidic device dramatically reduces reaction time and sample consumption; and (2) the SPR imaging yields real-time detection of the immunocomplex formation. Thus, an immunoreaction may be detected and quantitatively characterized in about 10 min. The sensitivity of this method is at the subnanomolar level. When gold nanoparticles are selectively coupled to the immunocomplex to cause signal amplification, the sensitivity reaches the ten to one hundred picomolar level but the time required increases to about 60 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号