首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
A simple method was developed and validated for the trace determination of 2-isopropylthioxanthone (ITX) in packaged drinks. Samples were extracted from the food matrix using acetonitrile:water (60:40, v/v), and further subjected to clean-up and preconcentration using solid-phase extraction prior to analysis by liquid chromatography-tandem mass spectrometry using multiple reaction monitoring (MRM) mode. The use of 2-isopropyl-[(2)H7]thioxanthen-9-one was incorporated into the method as an internal standard. Excellent 3-day interday precision data (RSD 0.72%, n=10), and intraday precision data (RSD 0.52%, n=10) were obtained on a 0.10 microg/L standard solution. Spiked samples (n=8) were used to gauge the accuracy of the method at the concentration levels of 2.5, 100, and 500 microg/kg in food; recoveries ranged from 97.0 to 103.0%. These excellent validation data suggest the exciting possibility of using this method for the determination of low levels of ITX migrating from printed food packaging materials into beverages with a method quantitation limit of 0.50 microg/kg. For the first time, analysis on a range of milk, juice, tea and yoghurt drinks, as well as their respective food packaging materials were performed for comparative studies on their ITX content.  相似文献   

2.
A simple and effective extraction method based on matrix solid-phase dispersion (MSPD) was developed to determine dimethoate, malathion, lufenuron, carbofuran, 3-hydroxycarbofuran, thiabendazole, difenoconazole and trichlorfon in coconut pulp using gas chromatography-mass spectrometry with selected ion monitoring (GC/MS, SIM). Different parameters of the method were evaluated, such as type of solid-phase (C(18), alumina, silica-gel and Florisil), the amount of solid-phase and eluent (dichloromethane, acetone, ethyl acetate, acetonitrile, n-hexane and n-hexane:ethyl acetate (1:1, v/v)). The best results were obtained using 0.5 g of coconut pulp, 1.0 g of C(18) as dispersant sorbent, 1.0 g of Florisil as clean-up sorbent and acetonitrile saturated with n-hexane as eluting solvent. The method was validated using coconut pulp samples fortified with pesticides at different concentration levels (0.25-1.0 mg kg(-1)). Average recoveries (four replicates) ranged from 70.1% to 98.7%, with relative standard deviations between 2.7% and 14.7%, except for lufenuron and difenoconazole, for which recoveries were 47.2% and 48.2%, respectively. Detection and quantification limits for coconut pulp ranged from 0.02 to 0.17 mg kg(-1) and from 0.15 to 0.25 mg kg(-1), respectively.  相似文献   

3.
A multi-residue method has been developed for determining 65 pesticide residues in greasy vegetable matrices such as avocado. Conventional organic solvent extraction assisted by a high-speed homogenizer was compared to pressurized liquid extraction (PLE) as extraction techniques. Following this, the lipophilic extract was purified using gel permeation chromatography (GPC). Alternative clean-up methods were also evaluated, as solid-phase extraction cartridges individually used and downstream coupled, but less effective lipophilic separation was archived. The pesticide residue determination was carried out using low-pressure gas chromatography coupled to tandem mass spectrometry (LP-GC-MS-MS), showing the applicability of this type of GC columns for the analysis of fat vegetable matrices. The proposed methodology was validated in avocado matrix. The recoveries were in the range 70-110%, with RSD values lower than 19%, at 12 and 50 microg/kg spiking levels. The limits of quantitation (LOQs) were in the range 0.04-8.33 microg/kg and the limits of detection (LODs) were between 0.01 and 2.50 microg/kg. All of them were lower than the maximum residue levels (MRLs) set by the European Union (EU) in avocado. The proposed method was evaluated analyzing pesticide residues in real avocado samples.  相似文献   

4.
采用基质固相分散(MSPD)代替液液分配和固相萃取,从蔬菜水果中提取、净化10种常用杀菌剂农药残留,用C18硅胶交联剂作为固相吸附剂,乙酸乙酯作为洗脱液,用HPLC/PDA和LC-MS进行分析检测。10种杀菌剂在0.5~5 mg/kg含量的添加回收率在65%~110%之间,相对标准偏差小于10%,使用HPLC、PDA和LC-MS的检出限分别在0.02~0.2 mg/kg和0.002~0.01 mg/kg之间。该方法节省溶剂,提取和净化一步完成,适用于新鲜水果和蔬菜中10种杀菌剂的残留分析。  相似文献   

5.
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on-line extraction and sample clean-up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10-200 microg/kg level showed good linear correlation. At the level of 50, 100 and 200 microg/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 microg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

6.
Gas chromatography with electron capture detection (GC-ECD) is a highly explosive-sensitive analytical technique. However, its application to the analysis of sediment extracts is hampered by the presence of numerous endogenous interferences. In the present study, solid-phase microextraction (SPME) was used both as a purification technique for sediment extracts and as an extraction technique for water samples prior to analysis by GC-ECD. SPME/GC-ECD coupling was optimized and applied to the trace analysis of nine explosives including nitroaromatics and RDX in real seawater and marine sediment samples. Addition of a high concentration of salt (30%, w/v) in the aqueous medium and use of a carbowax/divinylbenzene (CW/DVB) coating led to optimal extraction efficiencies. Method detection limits (MDLs) ranged from 0.05 to 0.81 microg/L in water and from 1 to 9 microg/kg in dry sediment. Except for RDX, spike recoveries in seawater were satisfactory (89-147%) when samples were fortified at 2 microg/L of each analyte. Spike recoveries from dry sediment fortified at 10 microg/kg of each analyte gave lower recoveries but these could also be due to degradation in the matrix. With a smaller volume of aqueous sample required compared to solid-phase extraction (SPE), SPME is an attractive method for the analysis of limited volumes of sediment pore-water. Moreover, the use of SPME eliminated interferences present in sediment extracts thus allowing the detection of the target analytes that were otherwise difficult to detect by direct injection.  相似文献   

7.
Wu G  Zhao S  Wu J  Dong S  Guo F  Wang L  Ye Q 《色谱》2011,29(6):501-506
利用超高效液相色谱-串联质谱(UPLC-MS/MS)结合凝胶渗透色谱(GPC)技术,建立了一种快速分离和测定皮革制品中7种尼泊金酯类防腐剂的分析方法。样品经超声提取、浓缩、GPC净化,甲醇-水溶液(1:1, v/v)溶解,采用Acquity UPLCBEH C18柱(50 mm×2.1 mm, 1.7 μm)分离,以甲醇和水为流动相,梯度洗脱,电喷雾负离子模式电离,采用多反应监测模式检测和外标法定量。该方法在0.1~1.0 mg/L范围内线性关系良好(r>0.99);在添加量为0.5~3.0 mg/kg时,平均回收率为(79.44±5.67)%~(98.07±9.50)%,相对标准偏差(RSD)为4.24%~14.00%;方法的检出限(LOD)为4~12 μg/kg,定量限(LOQ)为13.2~39.6 μg/kg。该方法操作简便、快捷、灵敏、准确,适合皮革中多种尼泊金酯类防腐剂的确证和定量测定。  相似文献   

8.
Li Y  Dong F  Liu X  Xu J  Li J  Kong Z  Chen X  Song W  Wang Y  Zheng Y 《Journal of chromatography. A》2011,1218(38):6667-6674
A novel and sensitive method was developed for the simultaneous determination of fenbuconazole and its main metabolites enantioselectively using chiral liquid chromatography coupled with tandem mass spectrometry. The separation and determination were performed using reversed-phase chromatography on a cellulose chiral stationary phase, a Chiralcel OD-RH (150 mm×4.6 mm) column, under isocratic conditions at 0.5 mL/min flow rate. The effects of three cellulose-based columns and three amylose-based columns on the separation were also investigated. The elution orders of the eluting enantiomers were identified by an optical rotation detector. The QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the extraction and clean-up of the soil and water samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under optimal conditions, the mean recoveries for all enantiomers from the soil samples were 82.5-104.1% with 2.7-9.5% intra-day relative standard deviations (RSD) and 5.7-11.2% inter-day RSD at 5, 25 and 50 μg/kg levels; the mean enantiomer recoveries from the water samples were 81.8-104.6% with 2.6-11.4% intra-day RSD and 5.3-10.4% inter-day RSD at 0.25, 0.5 and 2.5 μg/L levels. Coefficients of determination R2≥0.9991 were achieved for each enantiomer in the soil and water matrix calibration curves within the range of 1.0-125 μg/L. The limits of detection (LOD) for all enantiomers in the soil and water were less than 0.8 μg/kg, whereas the limit of quantification (LOQ) did not exceed 2.5 μg/kg. The results of the method validation confirm that this proposed method is convenient and reliable for the enantioselective determination of the enantiomers of fenbuconazole and its main metabolites in soil and water.  相似文献   

9.
Analytical methodology was developed and validated for the determination of spiroxamine residues in grapes, must, and wine by gas chromatography/ion trap-mass spectrometry (GC/IT-MS). Two extraction procedures were used: the first involved grapes, must, and wine extraction with alkaline cyclohexane-dichloromethane (9 + 1, v/v) solution, and the second grape extraction with acetone, dichloromethane, and petroleum ether. In both procedures, the extract was centrifuged, evaporated to dryness, and reconstituted in cyclohexane or 2,2,4-trimethylpentane-toluene (9 + 1, v/v), respectively. Spiroxamine diastereomers A and B were determined by GC/IT-MS, and a matrix effect was observed in the case of grapes but not in must and wine. Recovery of spiroxamine from fortified samples at 0.02 to 5.0 mg/kg ranged from 78-102% for grapes and must, with relative standard deviation (RSD) <13%; for red and white wines, recoveries ranged from 90 to 101% with RSD <9%. The limit of quantification was 0.02 mg/kg for grapes, must, and wine or 0.10 mg/kg for grapes, depending on the extraction procedure used.  相似文献   

10.
An analytical methodology for the analysis of four polar organophophorus pesticides (monocrotophos, mevinphos, phosphamidon, omethoate) in water and soil samples incorporating a molecularly imprinted solid-phase extraction (MISPE) process using a monocrotophos-imprinted polymer was developed. Binding study demonstrated that the polymer showed excellent affinity and high selectivity to monocrotophos. The MISPE procedure including the clean-up step to remove any interferences was optimized. The accuracy and selectivity of the MISPE process developed were verified using a non-imprinted (blank) polymer and a classical ENVI-18 cartridge as the SPE matrix during control experiments. The use of MISPE improved the accuracy and precision of the GC method and lowered the limit of detection. The recoveries of four polar organophosphorus pesticides (OPPs) extracted from 1 L of river water at a 100 ng/L spike level were in the range of 77.5-99.1%. The recoveries of organophosphorus pesticides extracted from a 5-g soil sample at the 100 microg/kg level were in the range of 79.3-93.5%. The limit of detection varied from 10 to 32 ng/L in water and from 12 to 34 microg/kg in soil samples. The molecularly imprinted polymer (MIP) enabled the selective extraction of four organophosphorus pesticides successfully from water and soil samples, demonstrating the potential of molecularly imprinted solid-phase extraction for rapid, selective, and cost-effective sample pretreatment.  相似文献   

11.
A novel analytical approach has been developed and evaluated for the quantitative analysis of a selected group of widely used pesticides (dimethoate, simazine, atrazine, diuron, terbuthylazine, methyl-parathion, methyl-pirimiphos, endosulfan I, endosulfan II, endosulfan sulphate, cypermethrin and deltamethrin), which can be found at trace levels in olive oil and olives. The proposed methodology is based on matrix solid-phase dispersion (MSPD), (with a preliminary liquid-liquid extraction in olive oil samples) using aminopropyl as sorbent material with a clean-up performed in the elution step with Florisil, followed by mass spectrometric identification and quantitation of the selected pesticides using both gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode and liquid chromatography tandem mass spectrometry (LC-MS-MS) in positive ionization mode. The recoveries obtained (with mean values between 85 and 115% (obtained at different fortification levels) with RSD values below 10% in most cases, confirm the usefulness of the proposed methodology for the analyses of these kind of complex samples with a high fat content. Moreover, the obtained detection limits, which were below 5 microg kg(-1) by LC-MS analyses and ranged from 10 to 60 microg kg(-1) by GC-MS meet the requirements established by the olive oil pesticide regulatory programs. The method was satisfactorily applied to different olives and olive oil samples.  相似文献   

12.
A simple and reliable sample methodology based on simultaneous ultrasonic extraction, sulfuric acid clean-up and headspace solid-phase microextraction (SPME)-gas chromatography-mass spectrometry has been developed as an advantageous analytical tool for the determination of seven polychlorinated biphenyl congeners in bird livers at low levels. The influence of several parameters on the efficiency of the proposed method was systematically investigated. The clean-up efficiency of sulfuric acid treatment was tested and compared with those of column chromatography (Flosiril, silica gel and alumina) and solid-phase extraction (SPE) (Supelclean ENVI-Carb cartridge) procedures. The use of sulfuric acid in the clean-up step prior to headspace solid-phase microextraction analysis allows the removal of interfering matrix compounds present in the liver extracts that would otherwise cause severe ionization suppression of the polychlorinated biphenyls (PCBs) during the ionization process. The optimized method had good linearity (R2>0.99) over the range studied (5-500 ng/g wet weight) and showed satisfactory level of precision, with RSD values lower than 10.6%. The obtained relative recoveries ranged between 63 and 94%. The limits of detection (0.06-0.63 ng/g wet weight) were low enough to check for harmful levels of polychlorinated biphenyls in biological samples, and were well below most of the restrictive limits established by European Union regulations. The method was found to be reliable under the operational conditions proposed and was applied successfully to the analysis of individual polychlorinated biphenyls in liver tissues. The results obtained from five bird species from Greece revealed the presence of the target compounds in all samples analyzed, at levels ranging between 0.54 and 39.45 ng/g wet weight.  相似文献   

13.
Design of an imprinted clean-up method for mycophenolic acid in maize   总被引:2,自引:0,他引:2  
In the present work, the development of imprinted polymers selective towards mycophenolic acid and their application in food analysis are reported for the first time. To synthesize the molecularly imprinted polymer (MIP) 4-vinylpyridine and ethyleneglycol dimethacrylate were applied as functional monomer and cross-linker, respectively. Besides the toxin itself, the implementation of structural analogues as templates was evaluated. A molecularly imprinted solid-phase extraction (MISPE) procedure was designed for the selective clean-up of maize extracts. Binding experiments and Scatchard analysis indicated the presence of specific binding sites in the imprinted polymers. The imprinting effect varied along with the selected template. The dissociation constant (K(D)) of the higher affinity binding sites ranged from 0.8 μmol/l to 15.6 μmol/l, while the K(D) of the lower affinity binding sites was in the range of 138.5-519.3 μmol/l. The performance of the MIPs throughout the clean-up of spiked maize sample extracts was evaluated and compared with the results obtained when applying a non-imprinted polymer. Depending on the polymers and the spiked concentration, recoveries after MISPE and non-imprinted solid-phase extraction varied respectively from 49% to 84% and from 28% to 31%. The imprinted polymers were superior regarding matrix effect, limit of detection (LOD) and limit of quantification (LOQ). LOD ranged from 0.17 μg/kg to 0.25 μg/kg and LOQ varied from 0.57 μg/kg to 0.82 μg/kg. Analysis of 15 maize samples by liquid chromatography tandem mass spectrometry revealed that the MIPs could be excellent sorbents for clean-up of contaminated food samples.  相似文献   

14.
赵榕  邵兵  赵婕  吴永宁  吴国华  薛颖 《色谱》2005,23(3):289-291
以C18反相色谱柱为分析柱,以0.1%甲酸水溶液-甲醇(体积比为98∶2)为流动相,采用同位素稀释液相色谱-电喷雾 质谱/质谱(LC-MS/MS)技术对加热淀粉类食品中的丙烯酰胺进行了测定。利用Oasis HLB固相萃取柱对样品进行净化。方 法的线性范围为10~500 μg/L,线性相关系数为0.9995。方法的定性检出限为6 μg/kg,定量检出限为20 μg/kg。高 、中、低3个浓度水平的加标回收率为96.8%~97.4%,相对标准偏差小于10%。  相似文献   

15.
固相萃取-高效液相色谱法测定钙强化食品中的维生素D   总被引:1,自引:0,他引:1  
赵榕  薛颖  吴国华  赵海燕  罗仁才 《色谱》2008,26(1):113-115
以含有体积分数为20%的0.95 mol/L柠檬酸水溶液的二甲基亚砜作为维生素D的破壁溶液,利用Chromabond XTR固相萃取柱(14500 mg, 70 mL)对样品进行提取和净化,建立了测定钙强化食品中维生素D的固相萃取-高效液相色谱方法。方法的线性范围为0.1~100.0 μg/mL,线性相关系数为0.999。方法的定性检出限为0.01 μg/g,定量检出限为0.03 μg/g。低(0.1 μg/g)、中(0.5 μg/g)、高(1.0 μg/g)三个浓度水平的加标回收率分别为106.2%,99.5%和100.1%,相对标准偏差小于10%。  相似文献   

16.
A method based on matrix solid-phase dispersion (MSPD) and gas chromatography to determine eight fungicides in fruits and vegetables is described. Fungicide residues were identified and quantified using nitrogen-phosphorus detection and electron-capture detection connected in parallel and confirmed by mass spectrometric detection. The method required 0.5 g of sample, C18 bonded silica as dispersant sorbent, silica as clean-up sorbent and ethyl acetate as eluting solvent. Recoveries from spiked orange, apple, tomato, artichoke, carrot and courgette samples ranged from 62 to 102% and relative standard deviations were less than 15% in the concentration range 0.05-10 mg kg(-1). Detection and quantitation limits ranged 3-30 microg kg(-1) and 10-100 microg kg(-1), respectively, with linear calibration curves up to 10 mg kg(-1). The analytical characteristics of MSPD compared very favourably with the results of a classical multiresidue method, which uses ethyl acetate and anhydrous sodium sulphate for the extraction.  相似文献   

17.
This paper describes the first validated method for the determination of 39 mycotoxins in wheat and maize using a single extraction step followed by liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (LC/ESI-MS/MS) without the need for any clean-up. The 39 analytes included A- and B-trichothecenes (including deoxynivalenol-3-glucoside), zearalenone and related derivatives, fumonisins, enniatins, ergot alkaloids, ochratoxins, aflatoxins and moniliformin. The large number and the chemical diversity of the analytes required the application of the positive as well as the negative ion ESI mode in two consecutive chromatographic runs of 21 min each. The solvent mixture acetonitrile/water/acetic acid 79 + 20 + 1 (v/v/v) has been determined as the best compromise for the extraction of the analytes from wheat and maize. Raw extracts were diluted 1 + 1 and were injected without any clean-up. Ion-suppression effects due to co-eluting matrix components were negligible in the case of wheat, whereas significant signal suppression for 12 analytes was observed in maize, causing purely proportional systematic errors. Method performance characteristics were determined after spiking blank samples on multiple levels in triplicate. Coefficients of variation of the overall process of <5.1% and <3.0% were obtained for wheat and maize, respectively, from linear calibration data. Limits of detection ranged from 0.03 to 220 microg/kg. Apparent recoveries (including both the recoveries of the extraction step and matrix effects) were within the range of 100 +/- 10% for approximately half of the analytes. In extreme cases the apparent recoveries dropped to about 20%, but this could be compensated for to a large extent by the application of matrix-matched standards to correct for matrix-induced signal suppression, as only a few analytes such as nivalenol and the fumonisins exhibited incomplete extraction. For deoxynivalenol and zearalenone, the trueness of the method was confirmed through the analysis of certified reference materials.  相似文献   

18.
吕春华  陈笑梅  刘海山 《色谱》2009,27(4):458-462
建立了测定纺织品中烷基酚(AP)和烷基酚聚氧乙烯醚(APnEO)(n2~16)的正相高效液相色谱法。以甲醇为提取溶剂,用索氏抽提法提取纺织品中的AP和APnEO,用正相高效液相色谱法测定,并对提取溶剂、提取方式和净化条件等前处理条件进行优化。该方法的检出限为1.0 mg/kg,回收率为90.4%~104.1%,相对标准偏差为0.64%~4.21%。采用该方法对多种基质纺织品进行检测,可满足残留检测要求。  相似文献   

19.
固相萃取-气相色谱法测定茶叶中残留的92种农药   总被引:13,自引:5,他引:8  
建立了茶叶中92种农药多残留的气相色谱分析方法。茶叶样品用乙腈一次性提取后,有机磷类农药经Envi-Carb固相小柱净化,用10 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,气相色谱-火焰光度检测器(GC-FPD)检测;有机氯类和拟除虫菊酯类农药经串联Envi-Carb和NH2固相小柱净化,用5 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,GC-电子捕获检测器(ECD)检测。采用外标法定量。添加回收试验的结果表明:92种农药的平均回收率为80.3%~117.1%,相对标准偏差为1.5%~9.8%。方法的检出限为0.0025~0.10 mg/kg。该方法的灵敏度、准确度和精密度均符合农药残留测定的技术要求。  相似文献   

20.
A sensitive and reliable liquid chromatography-tandem mass spectrometric with electrospray ionization method for determining aflatoxins in hazelnuts has been developed. Three different extraction techniques, such as homogenization, ultrasonic extraction, and matrix solid phase dispersion have been tested and compared in terms of recovery, matrix effect, accuracy and precision. Ultrasound extraction was the most performing sample preparation method. Absolute recoveries for analytes and I.S. ranged from 93 to 101%. Accuracy and precision were calculated using matrix matched calibration, and ranged 91-102% and 2-11%, respectively. CC alpha and CC beta for aflatoxin B1 (EU limit=2 microg/kg) were 2.15 and 2.33 microg/kg, respectively. A ruggedness test performed on three other matrices demonstrated that sonication time was critical and a matrix matched calibration must be constructed for every sort of matrix.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号