首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple sheathless capillary electrophoresis (CE)/mass spectrometry (MS) interface was constructed by combining widely used nanospray needles with fused-silica capillaries and it was successfully applied for the separation of peptides. The end of the CE capillary was pulled to a taper, etched and then fitted into the metal-coated nanospray borosilicate capillary. The nanospray needle can be used for several CE runs, but it can be easily and rapidly changed in the case of accidental breakage or evaporation of the coating. A fast capillary electrochromatographic method was also developed for MS analysis of peptides containing numerous basic amino acids.  相似文献   

2.
The first reported use of a carbon paste electrochemical detector for microchip capillary electrophoresis (CE) is described. Poly(dimethylsiloxane) (PDMS)-based microchip CE devices were constructed by reversibly sealing a PDMS layer containing separation and injection channels to a separate PDMS layer that contained carbon paste working electrodes. End-channel amperometric detection with a single electrode was used to detect amino acids derivatized with naphthalene dicarboxaldehyde. Two electrodes were placed in series for dual electrode detection. This approach was demonstrated for the detection of copper(II) peptide complexes. A major advantage of carbon paste is that catalysts can be easily incorporated into the electrode. Carbon paste that was chemically modified with cobalt phthalocyanine was used for the detection of thiols following a CE separation. These devices illustrate the potential for an easily constructed microchip CE system with a carbon-based detector that exhibits adjustable selectivity.  相似文献   

3.
La S  Kim A  Kim JH  Choi OK  Kim KR 《Electrophoresis》2002,23(7-8):1080-1089
An efficient capillary electrophoretic (CE) profiling and screening system based on dual modes of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) was developed for the simultaneous determination of 23 nonprotein amino acids (NPAAs) and 4 protein amino acids with aromatic moiety. It involves separation by an uncoated fused-silica capillary under phosphoric acid buffer in CZE mode and by another uncoated fused-silica capillary under neutral sodium dihydrogen phosphate buffer containing sodium dodecyl sulfate in MEKC mode. Migration orders of the amino acids studied on the two separation modes under each optimum condition were very different. The repeatability of migration times measured by the CZE and MEKC was found to be better than 4.8 and 3.4%, respectively, thereby enabling to cross-check the identification of each amino acid. The method linearity and limit of detection of the CZE for each amino acid were found to be adequate for the assay of aromatic amino acids. When the present CE profiling and screening analysis in dual modes was applied to plant seeds, NPAAs such as mimosine from Mimosa pudica Linné, and 2-phenylglycine from Lindera erythrocarpa Makino were positively detected along with tryptophan, phenylalanine and tyrosine.  相似文献   

4.
Swelling of the polyimide coating of fused-silica capillaries in acetonitrile-containing buffers was found to be the reason for several problems in capillary electrophoresis (CE) and capillary electrochromatography (CEC). Scanning electron microscopy photographs of the ends of raw fused-silica tubing showed that the coating becomes soft and increases its volume after longer contact with such buffers. As a consequence, separation efficiency can deteriorate, the capillary ends can clog or break off. To prevent swelling of the polyimide coating, fused-silica capillaries used in CE or CEC were heated at 300 degrees C for a longer period of time which improved their long-term stability in comparison to raw fused-silica tubing.  相似文献   

5.
介绍了一种在毛细管柱上原位腐蚀而成的多孔膜接口的制作方法,并用该接口构建了一类毛细管电泳二维分离技术平台。柱上原位腐蚀刻成的多孔膜接口具有零死体积、制作过程简易、成本低廉、耐用、柱间切换便捷等优点,特别适合作为基于毛细管柱的二维及多维电泳联用中的接口,是目前二维及多维毛细管柱联用中一类较为新型、实用、理想的接口。以鹿茸冻干粉可溶物样品为例,验证了该接口在二维毛细管电泳联用系统中的可行性和分离效能。实验结果表明:鹿茸冻干粉可溶物整个二维分离分析的时间在1 h内完成,二维分离系统的分辨率和总峰容量都比一维的高。  相似文献   

6.
Wu CH  Scampavia L  Ruzicka J 《The Analyst》2003,128(9):1123-1130
Automated sampling and fluorogenic derivatization of islet proteins (insulin, proinsulin, c-peptide) are separated and analyzed by a novel lab-on-valve capillary electrophoresis (LOV-CE) system. This fully integrated device is based on a micro sequential injection instrument that uses a lab-on-valve manifold to integrate capillary electrophoresis. The lab-on-valve manifold is used to perform all microfluidic tasks such as sampling, fluorogenic labeling, and CE capillary rejuvenation providing a very reliable system for reproducible CE separations. Fluorescence detection was coupled to an epiluminescence fluorescence microscope using a customized capillary positioning plate. This customized plate incorporated two fused-silica fiber optic probes that allow for simultaneous absorbance and fluorescence detection, extending the utility of this device. Derivatization conditions with respect to the sequence of addition, timing, injection position, and volumes were optimized through iterative series of experiments that are executed automatically by software control. Reproducibility in fluorogenic labeling was tested with repetitive injections of 3.45 mM insulin, yielding 1.3% RSD for peak area, 0.5% RSD for electromigration time, and 2.8% RSD for peak height. Fluorescence detection demonstrated a linear dynamic range of 3.43 to 6.87 microM for insulin (r2 = 0.99999), 0.39 to 1.96 pM for proinsulin (r2 = 0.99195) and 260 to 781 nM for c-peptide (r2 = 0.99983). By including hydrodynamic flushing immediately after the detection of the last analyte, the sampling frequency for islet protein analysis was increased. Finally, an in vitro insulin assay using rat pancreatic islet excretions was tested using this lab-on-valve capillary electrophoresis system.  相似文献   

7.
Short-chain organic acid contents in serum of natural latex are interesting to measure and capillary electrophoresis (CE) has proved to be a good tool for their study. In the present work a method has been developed to identify the short-chain organic acids present in sera of natural rubber latex (oxalic, formic, fumaric, aconitic, succinic, malic, glutaric, citric, acetic, glycollic, propionic and quinic acids), the separation was optimised and the quantification method validated. The separation was performed on a CE system with UV detection at 200 nm. The separation was carried out with an uncoated fused-silica capillary (57 cm x 50 microm I.D.) and was operated at -10 kV potential. The separation buffers were prepared with 0.5 M H3PO4, 0.5 mM cetyltrimethylammonium bromide and pH adjusted by adding NaOH to 6.25 except for propionic acid which was better measured at pH 7.00. Validation parameters are adequate and limits of detection range from 0.005 mM to 1.6 mM. Short-chain organic acids were measured with this method in sera of three different types of latex.  相似文献   

8.
A novel and convenient protocol for the preparation of an open-tubular column coated with chitosan-silica hybrid using chitosan and silane-coupling agent (γ-glycidoxy-propyltrimethoxysilane) was developed for CEC, in which, chitosan was covalently bonded to the inner wall of a fused-silica capillary using γ-glycidoxy-propyltrimethoxysilane as a cross-linking agent. The stationary phase was hydrophilic due to the chitosan-silica hybrid with abundant amine and hydroxyl functional groups. The chromatographic characteristics of the column were evaluated by the separation of some organic acids and inorganic anions. The column showed good selectivity for nucleotides, aromatic acids, and inorganic anions. The mechanism for the separation of these compounds was primarily based on the hydrophilic and electrostatic interactions combined with the electrophoretic mechanism. The CEC method on the column for the separation of these compounds was compared with CE method in a bare capillary.  相似文献   

9.
Qu Q  Liu Y  Tang X  Wang C  Yang G  Hu X  Yan C 《Electrophoresis》2006,27(22):4500-4507
An online preconcentration method based on electrostatic interaction between the analytes and inner surface of the capillary column was developed for the determination of zwitterionic analytes such as amino acids in CE coupled with a DAD. The amino acids possessed positive charges when they were dissolved in an acidic solvent. When they were injected into the column, they were attracted by the negatively charged inner surface of the fused-silica capillary column. An etched column was used to increase the area of the capillary's inner surface and, consequently increase the electrostatic interaction between the amino acids and the inner surface of the capillary column. It was found that when the sample was injected at 10 psi for 1 min and the pH value of the sample was 4, the amount of amino acids attracted to the inner surface of the capillary was maximum. Under these optimized experimental conditions, the detection sensitivity of CE-DAD was enhanced by 5200, 2800, and 3100 times for asparagine, tryptophan and phenylalanine, respectively, compared with normal CE separation. The method provided good reproducibility in terms of both migration time and peak height. It can be successfully used for the preconcentration zwitterion.  相似文献   

10.
高效毛细管电泳法同时测定多种神经肽物质的研究   总被引:3,自引:1,他引:2  
傅世江  才丽平  李艳杰 《色谱》1997,15(3):261-262
用0.1mol/LpH2.7磷酸缓冲液,在50μm×60cm熔融石英毛细管柱中、12kV电位下对SP、NKA、NT、SS及SP-片段等神经肽物质进行分离测定,对缓冲液及其pH值的选择进行研究。结果表明,高效毛细管电泳法是分析肽物质较为理想的方法。  相似文献   

11.
Whiting CE  Arriaga EA 《Electrophoresis》2006,27(22):4523-4531
This report is the first demonstration of the use of uncoated and dynamically coated capillaries for the separation of individual mitochondria via CE. Currently, the analysis of individual mitochondria relies upon fused-silica capillaries coated with a hydrophilic polymer (e.g. poly(acryloylaminopropanol)), which is used to minimize adsorption to the capillary surface. Both uncoated fused-silica capillaries and 0.2% w/w poly(vinyl alcohol) dynamic coating solutions are used to successfully analyze isolated individual mitochondrial particles using CE-LIF. While it was possible to separate mouse liver mitochondria on an uncoated capillary, rat liver mitochondria proved to have strong adsorption characteristics that only allowed them to be adequately separated with a PVA dynamic coating or a poly(acryloylaminopropanol) (AAP) capillary. The possible causes for this adsorption are analyzed and discussed. This study shows that uncoated and dynamically coated capillaries can be used in place of AAP-coated capillaries to analyze mitochondria and suggests the use of these capillaries for the analysis of other organelles, offering a greatly simplified method for the analysis of individual organelles.  相似文献   

12.
Wang Z  Wang J  Hu Z  Kang J 《Electrophoresis》2007,28(6):938-943
An approach for improving the separation performance of the enantioseparation by CE with vancomycin as chiral selector is described. In the present method, a solution of poly(dimethylacrylamide) (PDMA) was used for dynamic coating of the capillary wall to minimize the adsorption of vancomycin onto the capillary wall, and to depress the EOF. Compared with the bare fused-silica capillaries and the capillaries coated with the polycationic polymer hexadimethrine bromide (HDB), the PDMA-coated capillary displayed the best separation performance. The resulting coating could withstand hundreds of runs without losing its function. Moreover, a partial filling technique was applied to avoid interference in detection caused by the presence of vancomycin in the buffer. The separation time was shortened when a short-end-injection technique was applied. Several parameters such as buffer pH, vancomycin concentration and plug length of the vancomycin solution for the separation were optimized. Under the optimal conditions, all tested enantiomers, including FMOC amino acids derivatives, ketoprofen and fenoprofen, were baseline-separated in less than 4.2 min.  相似文献   

13.
虞科  林中营  程翼宇 《分析化学》2006,34(7):963-966
建立了一种基于粒子群优化算法的毛细管电泳条件辅助优化方法。以丹参为研究对象,将改良的色谱指数方程用于评价酚酸类成分的电泳分离性能,用粒子群优化算法对分离条件进行全局寻优,获得最佳的区带电泳分离条件(5.0 mmol/L硼砂,18.5 mmol/L磷酸二氢钠,6.1%乙腈,运行电压18.2 kV)。为进一步改善分离,在所获优化条件下添加50.0 mmol/L SDS,在胶束电动毛细管色谱分离模式下使酚酸类成分(原儿茶醛、丹参素、丹酚酸B等)得到更好分离。本方法准确可靠,可推广应用于其他复杂化学体系的毛细管电泳分离条件优化。  相似文献   

14.
Zhang Y  Gomez FA 《Electrophoresis》2000,21(15):3305-3310
This work demonstrates the use of an in-capillary procedure for derivatization of amino acids, peptides, and alkylamines by anhydrides using capillary electrophoresis (CE). Migrating in an uncoated fused-silica capillary, plugs of substrate and anhydride are injected separately and electrophoresed. Differential transport velocities permit the separate zones to penetrate each other under an applied field, thereby facilitating reaction. In initial experiments the extent of reaction between tryptophan and acetic anhydride was examined and product amounts quantitated by CE. In separate experiments a series of amino acids and peptides were injected into the capillary and reacted with phthalic anhydride on-column to yield the phthalic derivatized species. Finally, on-column derivatization of alkylamines with phthalic anhydride was investigated and electrophoretic mobility related to molecular weight of the derivatized amines. These procedures illustrate the use of the capillary as a microreactor in the facile synthesis of derivatized molecules and ease of quantitation of reaction products under conditions of electrophoresis.  相似文献   

15.
A fused-silica capillary that is wall-modified via chemically bonding a sulfonated polymer to the capillary wall has a uniform negative charge density on its surface and produces an electroosmotic flow (EOF) greater than 4 x 10(-4) cm2 V(-1) s(-1) The EOF is nearly independent of buffer pH over the pH range of 2 to 10 and is lower than the EOF obtained for the bare fused-silica capillary at the more basic pH but is higher at the more acidic buffer pH. Optimization of buffer pH can be based on analyte pKa values to improve the overall quality of the capillary zone electrophoresis (CZE) separation of complex mixtures of weak acid and base analytes. Because of the high EOF in an acidic buffer, the capillary is useful for the separation of weak organic bases which are in their cation forms in the acidic buffer. EOF for the sulfonic acid bonded phase capillary can be adjusted via buffer additives such as organic solvent, tetraalkylammonium salts, multivalent cations and alkylsulfonic acids. The advantages of utilizing buffer pH and the EOF buffer modifiers to enhance migration time, selectivity, and resolution in CZE separations with this capillary are illustrated using a series of test analyte mixtures of inorganic anions, carboxylic acids, alkylsulfonic acids, benzenesulfonic acids, sulfas, pyridines, anilines or small-chain peptides.  相似文献   

16.
We describe a highly sensitive CE with laser-induced fluorescence (LIF) detection for the analysis of N-linked oligosaccharides in glycoproteins using rhodamine 110 as a fluorescence derivatization reagent. One CE separation is performed using a fused-silica capillary and neutral pH buffer conditions and allows for the separation of sialo-oligosaccharides according to the number of sialic acids. An alternate separation is performed using the same capillary and acidic pH buffer conditions, enabling the separation of asialo-oligosaccharides according to their sizes. The derivatization and separation conditions for the analysis of sialo- and asialo-oligosaccharides were optimized. Furthermore, we applied the proposed method for the analyses of N-linked sialo- and asialo-oligosaccharides in glycoproteins (ribonuclease B, fetuin, and recombinant human erythropoietin).  相似文献   

17.
The application of chemometric techniques to the resolution of overlapped peaks in capillary electrophoresis (CE) is described. When a physical separation can not be completely accomplished, chemometrics might still resolve the determination of the analytes mathematically. CE with diode array detection can provide a large amount of data consisting of spectra registered over time. In this study, the capillary electrophoretic separation of 1,2-naphthoquinone-4-sulfonate derivatives of amino acids is studied. Most of the common amino acid derivatives can be separated at 30 kV in a fused-silica capillary by using a 40 mM sodium tetraborate + isopropanol (3:1 v/v) solution as background electrolyte. However, peaks of certain derivatives (Phe, His, Leu and Ile) still overlap. A multivariate curve resolution method based on an alternating least squares optimization procedure is used for the resolution of the overlapped electrophoretic peaks. The method takes advantage of spectral and electrophoretic differences of analytes to recover their pure electrophoretic and spectral profiles. In addition, each analyte in the mixture can be quantified using the corresponding standards.  相似文献   

18.
A method for coupling an electrophoretic driven separation to a liquid flow, using conventional fused-silica capillaries and a soft polymeric interface is presented. A novel design of the electrode providing high voltage to the electrophoretic separation was also developed. The electrode consisted of a conductive polyimide/graphite imbedded coating immobilized onto the capillary electrophoresis (CE) column inlet. This integrated electrode gave the same separation performance as a commonly used platinum electrode. The on-column electrode also showed good electrochemical stability in chronoamperometric experiments. In addition, with this electrode design, the electrode position relative to the inlet end of the CE column will always be constant and well defined. The on-line flow injection analysis (FIA)-CE system was used with electrospray ionization (ESI)-time of flight (TOF)-mass spectrometry detection. The preparation of the PDMS (poly(dimethylsiloxane)) interface for FIA-CE is described in detail and used for initial tests of the on-column polymer-imbedded graphite inlet electrode. In this interface, a pressure-driven liquid flow, a make up CE electrolyte and a CE column inlet meet in a two-level cross (95 microm ID) in the PDMS structure, enabling independent flow characterization.  相似文献   

19.
A miniaturized post-column fluorimetric detection cell for capillary separation methods based on optical fibers and liquid core waveguides (LCWs) is described. The main part of the detection cell is a fused-silica capillary coated with Teflon AF serving as an LCW. The optical fibers are used both for coupling the excitation source with the detection domain in the LCW and for the axial fluorescence collection from the LCW end. The latter fiber is connected with a compact CCD spectrometer that serves for the rejection of the scattered excitation light and for the fluorescence signal detection. The proposed design offers a compact fluorescence detector for various microcolumn separation techniques without optical elements such as filters or objectives. Moreover, its construction and optical adjustment are very simple and the whole system is highly miniaturized. The function of the detection cell is demonstrated by CE of amino acids labelled by fluorescein-based tags. Separations of different standard amino acid mixtures and plasma samples are presented. The comparison of plasma amino acid levels of individuals being in good health with those of patients with inherited metabolic disorders is also shown.  相似文献   

20.
A competitive immunoassay based on capillary electrophoresis (CE) with laser-induced fluorescence (LIF) has been developed for the determination of recombinant hirudin (r-hirudin) in biological mixtures. Hirudin, a thrombin inhibitor, is a polypeptide of 65 amino acids. To check purity levels and perform pharmacokinetic studies of (r-hirudin), specific and reproducible analysis methods are demanded. The work involved the development of separation conditions allowing for routine analysis of plasma samples. In this study, r-hirudin was labeled with fluorescein isothiocyanate (FITC), and FITC-labeled r-hirudin was purified using high-performance liquid chromatography. The purified product was then mixed with the sample followed with the addition of anti-hirudin antibody. Free, antibody-bound, and tagged r-hirudin could be separated within 5 min by CE analysis using uncoated fused-silica capillary with high reproducibility. The developed method can be used to determine r-hirudin with good precision and a detection limit lower than 20 nM. This result demonstrates the feasibility of the CE-LIF immunoassay method for the determination of r-hirudin in plasma samples.  相似文献   