首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
CZE for the speciation of arsenic in aqueous soil extracts   总被引:2,自引:0,他引:2  
We developed two separation methods using CZE with UV detection for the determination of the most common inorganic and methylated arsenic species and some phenylarsenic compounds. Based on the separation method for anions using hydrodynamic sample injection the detection limits were 0.52, 0.25, 0.27, 0.12, 0.37, 0.6, 0.6, 1.2 and 1.0 mg As/L for phenylarsine oxide (PAO), p-aminophenylarsonic acid (p-APAA), o-aminophenylarsonic (o-APAA), phenylarsonic acid (PAA), 4-hydroxy-3-nitrobenzenearsonic acid (roxarsone), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenite or arsenious acid (As(III)) and arsenate (As(V)), respectively. These detection limits were improved by large-volume sample stacking with polarity switching to 32, 28, 14, 42, 22, 27, 26 and 27 microg As/L for p-APAA, o-APAA, PAA, roxarsone, MMA, DMA, As(III) and As(V), respectively. We have applied both methods to the analysis of the arsenic species distribution in aqueous soil extracts. The identification of the arsenic species was validated by means of both standard addition and comparison with standard UV spectra. The comparison of the arsenic species concentrations in the extracts determined by CZE with the total arsenic concentrations measured by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) indicated that CZE is suited for the speciation of arsenic in environmental samples with a high arsenic content. The extraction yield of phenylarsenic compounds from soil was derived from the arsenic concentrations of the aqueous soil extracts and the total arsenic content of the soil determined by ICP-AES after microwave digestion. We found that 6-32% of the total amount of arsenic in the soil was extractable by a one-step extraction with water in dependence on the type of arsenic species.  相似文献   

2.
An on-line method capable of the separation of arsenic species was developed for the speciation of arsenite As(III), arsenate As(V), monomethylarsenic (MMA) and dimethylarsenic acid (DMA) in biological samples. The method is based on the combination of high-performance liquid chromatograph (HPLC) for separation, UV photo oxidation for sample digestion and hydride generation atomic fluorescence spectrometry (HGAFS) for sensitive detection. The best separation results were obtained with an anion-exchange AS11 column protected by an AG11 guard column, and gradient elution with NaH2PO4 and water as mobile phase. The on-line UV photo oxidation with 1.5% K2S2O8 in 0.2 mol L(-1) NaOH in an 8 m PTFE coil for 40 s ensures the digestion of organoarsenic compounds. Detection limits for the four species were in the range of 0.11-0.15 ng (20 microL injected). Procedures were validated by analysis of the certified reference materials GBW09103 freeze-dried human urine and the results were in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of blood arsenic species with no need of sample pretreatment. Speciation of arsenic in blood samples collected from two patients after the ingestion of realgar-containing drug reveals slight increase of arsenite and DMA, resulting from the digestion of realgar.  相似文献   

3.
Arsenic compounds including arsenous acid (As(III)), arsenic acid (As(V)), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were separated by high-performance liquid chromatography (HPLC) and detected by inductively coupled plasma mass spectrometry (ICP-MS). A Hamilton PRX-100 anionic-exchange column and a pH 8.5 K2HPO4/KH2PO4 5.0 × 10−3 mol L−1 mobile phase were used to achieve arsenic speciation. The separation of arsenic species provided peaks of As(III) at 2.75 min, DMA at 3.33 min, MMA at 5.17 min and As(V) at 12.5 min. The detection limits, defined as three times the standard deviation of the lowest standard measurements, were found to be 0.2, 0.2, 0.3 and 0.5 ng mL−1 for As(III), DMA, MMA and As(V), respectively. The relative standard deviation values for a solution containing 5.0 μg L−1 of As(III), DMA, MMA and As(V) were 1.2, 2.1, 2.5 and 3.0%, respectively. This analytical procedure was applied to the speciation of arsenic compounds in drinking (soft drink, beer, juice) samples. The validation of the procedure was achieved through the analysis of arsenic compounds in water and sediment certified reference materials.  相似文献   

4.
A high performance liquid chromatography-microwave digestion-hydride generation-atomic absorption spectrometry (HPLC-MW-HG-AAS) coupled method is described for As(III), As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB) and arsenocholine (AsC) determination. A Hamilton PRP-X100 anion-exchange column is used for carrying out the arsenic species separation. As mobile phase 17 mM phosphate buffer (pH 6.0) is used for As(III), As(V), MMA and DMA separation, and ultrapure water (pH 6.0) for AsB and AsC separation. Prior to injection into the HPLC system AsB and AsC are isolated from the other arsenic species using a Waters Accell Plus QMA cartridge. A microwave digestion with K(2)S(2)O(8) as oxidizing agent is used for enhancing the efficiency of conversion of AsB and AsC into arsenate. Detection limits achieved were between 0.3 and 1.1 ng for all species. The method was applied to arsenic speciation in fish samples.  相似文献   

5.
The performance of microHPLC-microconcentric nebulizer-inductively coupled plasma-mass spectrometry (ICP-MS) coupling for the simultaneous determination of As(III), As(V), monomethylarsenic acid (MMA), dimethylarsinic acid (DMA), selenite (SeIV) and selenate (SeVI) in water was evaluated. The accurate reduction of the off-column dead volume, specially the capillary of the micronebulizer, as well as the optimization of chromatographic conditions led to the claimed advantages expected for microbore columns: a significant diminution of sample and solvent consumption without sacrificing sensitivity and the overall resolution in faster analysis time (less than 5 min). Detection limits are in the range 0.03-0.04 microg L(-1) for arsenic species and 0.35 microg L(-1) for selenium species. The developed method was validated by analysing different spiked environmental water samples. Linearity, tested up to 50 microg L(-1), showed correlation coefficients above 0.999 and no matrix effect for high saline water samples. Good accuracy and repeatability was obtained for spiked influent and effluent water treatment plant.  相似文献   

6.
We describe a method for continuously monitoring both hydride- and nonhydride-forming arsenic species in 10-microL microdialysate samples by coupling together on-line high-performance liquid chromatography (HPLC), a post-column UV/TiO2 film reactor, and hydride generation (HG) inductively coupled plasma mass spectrometry (ICP-MS). To maximize the signal intensities of the desired arsenic species, we optimized the photocatalytic oxidation efficiency of the analyte species and used a rapid on-line pre-reduction process to convert the oxidized species into As(III) prior to HG-ICP-MS determination. The UV/nano-TiO2 film reactor was manufactured by coating nano-TiO2 onto the interior of a glass tube. Impregnation and sol-gel methods were employed to deposit the TiO2 films, and their effectiveness for the oxidation of organic arsenicals was compared. To enhance the decomposition efficiency of organic arsenicals, we investigated the effects of the acidity and the composition of the column effluent. Because of the improved HG efficiency toward the tested arsenicals and the adoption of a segmented flow technique to retain the peak resolution in our on-line LC-UV/nano-TiO2 film reactor-HG-ICP-MS instrument, the detection limits for arseneous acid [As(III)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenic acid [As(V)], and arsenobetaine (AsB) were all in the submicrogram-per-liter range (based on 3 sigma) for 10-microL injections. A series of validation experiments--analyses of certified reference urine and rabbit serum samples--indicated that these methods can be applied satisfactorily to the continuous determination of As(III), MMA, DMA, As(V), and AsB in blood and in the extracellular space of target organs.  相似文献   

7.
A method using high-performance liquid chromatography/inductively coupled plasma mass spectrometry (HPLC/ICP-MS) has been developed to determine inorganic arsenic (arsenite, arsenate) along with organic arsenic compounds (monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, arsenocholine, trimethylarsine oxide, tetramethylarsonium ion and several arsenosugars) in fish, mussel, oyster and marine algae samples. The species were extracted by means of a methanol/water mixture and a dispersion unit in 2 min, with extraction efficiencies ranging from 83 to 107% in the different organisms. Up to 17 different species were determined within 15 min on an anion-exchange column, using a nitric acid gradient and an ion-pairing reagent. As all species are shown in one chromatogram, a clear overview of arsenic distribution patterns in different marine organisms is given. Arsenobetaine is the major compound in marine animals whereas arsenosugars and arsenate are dominant in marine algae. The method was validated with CRM DORM-2 (dogfish muscle). Concentrations were within the certified limits and low detection limits of 8 ng g(-1) (arsenite) to 50 ng g(-1) (arsenate) were obtained.  相似文献   

8.
An on-line method capable of the separation of arsenic species was developed for the speciation of arsenite As(III), arsenate As(V), monomethylarsenic (MMA) and dimethylarsenic acid (DMA) in biological samples. The method is based on the combination of high-performance liquid chromatograph (HPLC) for separation, UV photo oxidation for sample digestion and hydride generation atomic fluorescence spectrometry (HGAFS) for sensitive detection. The best separation results were obtained with an anion-exchange AS11 column protected by an AG11 guard column, and gradient elution with NaH2PO4 and water as mobile phase. The on-line UV photo oxidation with 1.5% K2S2O8 in 0.2 mol L–1 NaOH in an 8 m PTFE coil for 40 s ensures the digestion of organoarsenic compounds. Detection limits for the four species were in the range of 0.11–0.15 ng (20 μL injected). Procedures were validated by analysis of the certified reference materials GBW09103 freeze-dried human urine and the results were in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of blood arsenic species with no need of sample pretreatment. Speciation of arsenic in blood samples collected from two patients after the ingestion of realgar-containing drug reveals slight increase of arsenite and DMA, resulting from the digestion of realgar.  相似文献   

9.
Kitagawa F  Shiomi K  Otsuka K 《Electrophoresis》2006,27(11):2233-2239
CE with indirect UV and mass-spectrometric detection was used for the simultaneous determination of arsenic acid (As(V)), arsenous acid (As(III)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), trimethylarsine oxide (TMAO), tetramethylarsonium ion (TMA(+)), arsenobetaine (AB), and arsenocholine (AC). In the CE-indirect UV analysis, a baseline separation of arsenic species was successfully achieved by using a basic background solution (BGS) for anions and an acidic BGS for cations, respectively. The LOD values in CE-indirect UV for the individual analytes were 7.8, 12.5, 7.8, 12.5, 62.5, 125, 250, and 62.5 ppm, respectively. To achieve sensitive and selective analysis, CE coupled with ESI-MS was applied to the determination of arsenic compounds. The organic arsenic species were successfully separated with a higher sensitivity by CE-MS using the acidic BGS. The LODs in CE-MS for MMA, DMA, TMAO, TMA(+), AB, and AC were 1.0, 0.1, 0.01, 0.1, 0.01, and 0.01 ppm, respectively. In contrast, the analysis of inorganic arsenic species (As(V) and As(III)) resulted in a lower detectability in CE-MS compared to that obtained with the CE-indirect UV analysis. However, the speciation of eight arsenics by CE-MS was successfully achieved in a single run by switching the ESI polarity during MS detection.  相似文献   

10.
Enzymatic hydrolysis of seafood materials for isolating arsenic species (As(III), As(V), DMA and AsB) has been successfully performed by assisting the procedure with ultrasound energy (35 kHz) supplied by an ultrasound water-bath. The use of pepsin, as a proteolytic enzyme, under optimized operating conditions (pH 3.0, temperature 40 °C, enzyme to sample ratio of 0.3) led to an efficient assistance of the enzymatic process in a short period of time (from 4.0 to 30 min). The enzymatic extract was then subjected to a clean-up procedure based on ENVI-Carb™ solid phase extraction (SPE). An optimized anion exchange high performance liquid chromatography (HPLC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS) permitted the fast separation (less than 15 min) of six different arsenic species (arsenite, As(III); arsenate, As(V); dimethylarsinic acid, DMA; and arsenobetaine, AsB; as well as monomethylarsonic acid, MMA; and arsenocholine, AsC) in a single run. Relative standard deviations (n = 11) of the over-all procedure were 7% for AsB and DMA, 11% for As(III) and 9% for MMA. HPLC–ICP-MS determinations were performed using aqueous calibrations covering arsenic concentrations of 0, 5, 10, 25, 100 and 200 μg L−1 (expressed as arsenic) for As(III), As(V), MMA, DMA and AsC; and 0, 125, 250, 500, 750, 1000 and 2000 μg L−1 (expressed as arsenic) for AsB. Germanium (5 μg L−1) was used as an internal standard. Analytical recoveries from the anion exchange column varied from 96 to 105% (enzymatic digests spiked with low target concentrations), from 97 to 104% (enzymatic digests spiked with intermediate target concentrations), and from 98 to 103% (enzymatic digests spiked with high target concentrations). The developed method was successfully applied to two certified reference materials (CRMs), DORM-2 and BCR 627, which offer certified AsB and DMA contents, and also to different seafood samples (mollusks, white fish and cold water fish). Good agreement between certified and found AsB concentrations was achieved when analyzing both CRMs; and also, between certified and found DMA concentrations in BCR 627. In addition, the sum of the different arsenic species concentrations found in most of the analyzed samples was statistically similar to the assessed total arsenic concentrations after a total sample matrix decomposition treatment.  相似文献   

11.
建立了微波酸提取/液相色谱-电感耦合等离子体质谱联用(LC-ICP-MS)测定动物源性中药中6种砷形态(亚砷酸盐As(Ⅲ),砷酸盐As(V),一甲基砷MMA,二甲基砷DMA,砷甜菜碱As B和砷胆碱As C)的分析方法。采用1%HNO_3溶液在80℃微波提取10 min,经离心分层,过固相萃取SEP C18柱和0.45μm滤膜,以25 mmol/L NH_4H_2PO_4溶液(p H 6.7)-乙醇(99∶1,体积比)为流动相进行等度洗脱,各砷形态在10 min内实现基线分离。结果显示,6种砷形态在1.0~100.0μg/L范围内线性关系良好,相关系数为0.999 5~0.999 7,方法检出限(LOD)为0.24~1.0μg/kg,相对标准偏差(RSD)为0.96%~2.0%。将方法应用于地龙、水蛭、海螵蛸、桑螵蛸、石决明和鸡内金中6种砷形态的测定,加标回收率为94.2%~103.8%,提取效率为95.5%~102.8%,优于热提取法。方法快速、准确、重现性好,适用于动物源性中药及类似样品中的砷元素形态分析及质量监控。  相似文献   

12.
The stability of arsenic, selenium, antimony and tellurium species in water and urine (NIST SRM 2670n) as well as in extracts of fish and soil certified reference materials (DORM-2 and NIST SRM 2710) has been investigated. Stability studies were carried out with As(III), As(V), arsenobetaine, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), phenylarsonic acid (PAA), Se(IV), Se(VI), selenomethionine, Sb(III), Sb(V) and Te(VI). Speciation analysis was performed by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Best storage of aqueous mixtures of the examined species was achieved at 3 degrees C whereas at -20 degrees C species transformation especially of selenomethionine and Sb(V) took place and a new selenium species appeared within a period of 30 days. Losses and species transformations during extraction processes were investigated. Extraction of the spiked fish material with methanol/water led to partial conversion of Sb(III), Sb(V) and selenomethionine to two new antimony and one new selenium species. The other arsenic, selenium and tellurium species were almost quantitatively extracted. For soil spiked with MMA, PAA, Se(IV) and Sb(III), recoveries after extraction with water and sulfuric acid (0.01 mol/L) were below 20%.  相似文献   

13.
This study aimed to establish complementary high performance liquid chromatography (HPLC) methods including three modes of separation: ion pairing, cation exchange, and anion exchange chromatography, with detection by inductively coupled plasma mass spectrometry (ICPMS). The ion pairing mode enabled the separation of inorganic arsenate (As(V)), monomethylarsonic acid (MMA(V)), and dimethylarsinic acid (DMA(V)). However, the ion pair mode was unable to differentiate inorganic arsenite (As(III)) from arsenobetaine (AsB); instead, cation exchange chromatography was used to isolate and quantify AsB. Anion exchange chromatography was able to speciate all of the aforementioned arsenic species. Potential inaccurate quantification problem with urine sample containing elevated concentration of AsB, which eluted immediately after As(III) in anion exchange or ion pairing mode, was overcame by introducing a post-column hydride generation (HG) derivatization step. Incorporating HG between HPLC and ICPMS improved sensitivity and specificity by differentiating AsB from hydride-forming arsenic species. This paper emphasizes the usefulness of complementary chromatographic separations in combination with HG-ICPMS to quantitatively determine concentrations of As(III), DMA(V), MMA(V), As(V), and AsB in the sub-microgram per liter range in human urine.  相似文献   

14.
Arsenic-speciation analysis in marine samples was performed by high-pressure liquid chromatography (HPLC) with ICP–MS detection. Separation of eight arsenic species—AsIII, MMA, DMA, AsV, AB, TMAO, AC and TeMAs+—was achieved on a C18 column with isocratic elution (pH 3.0), under which conditions AsIII and MMA co-eluted. The entire separation was accomplished in 15 min. The HPLC–ICP–MS detection limits for the eight arsenic species were in the range 0.03–0.23 μg L−1 based on 3σ for the blank response (n=5). The precision was calculated to be 2.4–8.0% (RSD) for the eight species. The method was successfully applied to several marine samples, e.g. oysters, fish, shrimps, and marine algae. Low-power microwave digestion was employed for extraction of arsenic from seafood products; ultrasonic extraction was employed for the extraction of arsenic from seaweeds. Separation of arsenosugars was achieved on an anion-exchange column. Concentrations of arsenosugars 2, 3, and 4 in marine algae were in the range 0.18–9.59 μg g−1. This paper was presented at the European Winter Conference 2005  相似文献   

15.
An improved analytical procedure is presented for the separation and simultaneous determination of hydride-forming (toxic) and not hydride-forming (non-toxic) arsenic species in human urine. Separation was performed by cation-exchange chromatography using a new solid phase type based on the continuous bed chromatography (CBC) technology. This column permits by a factor of 4 higher flow rates than conventional columns resulting in a drastical reduction of retention times without any loss of resolution. Using this type of column, arsenobetaine (AsBet), arsenocholine (AsChol), and dimethylarsinic acid (DMA) were separated from the more toxic arsenic species arsenous acid (As(III)), arsenic acid (As(V)), and methylarsonic acid (MA) within only 4 min. The HPLC system was coupled via a flow injection system and either a UV or a microwave (MW) reactor to the HG-AAS instrument. UV photolysis and MW digestion were used to transform AsBet and AsChol to hydride-forming species and to make them accessible to HG-AAS. UV photolysis turned out to be more suitable for this application than MW digestion, because the latter technique led to peak broadening and poorer performance. The described procedure was applied to the determination of arsenic species in urine samples of non-occupationally exposed persons before and 12 h after seafood consumption. Detection limits were about 1 μg/L for each arsenic species. After consumption, the AsBet and DMA excretion increased by at least a factor of 150 for AsBet and by a factor of 6 for DMA, respectively, while the excretion of the other species did not increase significantly. This invalidates the use of total urinary arsenic as well as total hydride-forming arsenic as an indicator for exposure to inorganic arsenic. Received: 12 August 1998 / Revised: 30 October 1998 / Accepted: 24 November 1998  相似文献   

16.
Le XC  Cullen WR  Reimer KJ 《Talanta》1993,40(2):185-193
An analytical method based on microwave decomposition and flow injection analysis (FIA) coupled to hydride generation atomic absorption spectrometry (HGAAS) is described. This is used to differentiate arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA) from organoarsenic compounds usually present in seafood. Without microwave digestion, direct analysis of urine by HGAAS gives the total concentration of As(III), As(V), MMA and DMA because organoarsenic compounds such as arsenobetaine, usually found in most seafood, are not reducible upon treatment with borohydride and therefore cannot be determined by using the hydride generation technique. The microwave oven digestion procedure with potassium persulfate and sodium hydroxide as decomposition reagents completely decomposes all arsenicals to arsenate and this can be measured by HGASS. Microwave decomposition parameters were studied to achieve efficient decomposition and quantitative recovery of arsenobetaine spiked into urine samples. The method is applied to the determination of urinary arsenic and is useful for the assessment of occupational exposure to arsenic without intereference from excess organoarsenicals due to the consumption of seafood. Analysis of urine samples collected from an individual who ingested some seafood revealed that organoarsenicals were rapidly excreted in urine. After the ingestion of a 500-g crab, a 10-fold increase of total urinary arsenic was observed, due to the excretion of organoarsenicals. The maximum arsenic concentration was found in the urine samples collected approximately between 4 to 17 hr after eating seafood. However, the ingestion of organoarsenic-containing seafoods such as crab, shrimp and salmon showed no effect on the urinary excretion of inorganic arsenic, MMA and DMA.  相似文献   

17.
Arsenic speciation analysis in marine samples was performed using ion chromatography (IC) with inductively coupled plasma mass spectrometry (ICP‐MS) detection. The separation of eight arsenic species, viz. arsenite, monomethyl arsonic acid, dimethylarsinic acid, arsenate, arsenobetaine, tetramethylarsine oxide, arsenocholine and tetramethylarsonium ion was achieved on a Dionex AS4A (weaker anion exchange column) by using a nitric acid pH gradient eluent (pH 3.3 to 1.3). The entire separation was accomplished in 12 min. The detection limits for the eight arsenic species by IC–ICP‐MS were in the range 0.03–1.6 µ g l?1, based on 3σ of the blank response (n = 6). The repeatability and day‐to‐day reproducibility were calculated to be less than 10% (residual standard deviation) for all eight species. The method was validated by analyzing a certified reference material (DORM‐2, dogfish muscle) and then successfully applied to several marine samples, e.g. oyster, fish muscle, shrimp and marine algae. The low power microwave digestion was employed for the extraction of arsenic from seafood products. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.
The determination of seven arsenic species in seafood was performed using ion exchange chromatography on an IonPac AS7 column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The effect of five parameters on arsenic extraction recoveries was evaluated in certified reference materials. The recoveries of total arsenic and of arsenic species with the two best extraction media (100% H2O and 80% aqueous MeOH) were generally similar in the five seafood certified reference materials considered. However, because MeOH co-elutes with arsenite, which would result in a positively biased arsenite concentration, the 100% H2O extraction conditions were selected for validation of the method. Figures of merit (linearity, LOQs (0.019-0.075 mg As kg−1), specificity, trueness (with recoveries between 82% (As(III)) and 104% (As(V) based on spikes or certified concentrations), repeatability (3-14%), and intermediate precision reproducibility (9-16%) of the proposed method were satisfactory for the determination of arsenite, monomethylarsonic acid, dimethylarsinic acid, arsenate, arsenobetaine and arsenocholine in fish and shellfish. The performance criteria for trimethylarsine oxide, however, were less satisfactory. The method was then applied to 65 different seafood samples. Arsenobetaine was the main species in all samples. The percentage of inorganic arsenic varied between 0.4-15.8% in shellfish and 0.5-1.9% at the utmost in fish. The main advantage of this method that uses only H2O as an extractant and nitric acid as gradient eluent is its great compatibility with the long-term stability of both IEC separation and ICP-MS detection.  相似文献   

19.
The extraction of arsenic from freeze-dried apples and subsequent determination of individual arsenic species by HPLC-ICP-MS is described. Solvent extraction with sonication using various aqueous and aqueous/solvent mixtures was initially evaluated by measuring total arsenic extracted by ICP-MS. A two step procedure using overnight treatment with alpha-amylase enzyme followed by sonication for 6 h with 40:60 acetonitrile-water was found to provide good extraction efficiency. The concentration of arsenic extracted was compared with the concentration of total arsenic in the samples determined using ICP-MS after microwave digestion in order to calculate extraction efficiency. Individual arsenic species in the extracts were measured using HPLC-ICP-MS. The three most abundant arsenic species found were arsenite, arsenate and dimethylarsinic acid. Total arsenic concentrations in the freeze-dried apple samples ranged from 8.2 to 80.9 micrograms kg-1 As, dry mass. By HPLC-ICP-MS, the relative amount of inorganic arsenic in the samples ranged from 73 to 90% of the sum of the arsenic species detected in each sample.  相似文献   

20.
Vela NP  Heitkemper DT  Stewart KR 《The Analyst》2001,126(7):1011-1017
Arsenic present in freeze-dried carrots was extracted using accelerated solvent extraction (ASE). Several parameters, including selection of the dispersing agent, extraction time, number of extraction cycles, particle size and extraction temperature, were evaluated to optimize the ASE method. Filtering and treatment with C-18 SPE cartridges were also evaluated as part of the sample preparation procedure before speciation analysis. The method was validated by spiking single arsenical and mixed arsenical standards on the dispersing agent and on portions of freeze-dried carrot prior to extraction. LC-ICP-MS was used to determine individual arsenic species in the carrot extracts. A weak anion-exchange column was used for the separation of As(III), As(v), monomethylarsonic acid (MMA), dimethylarsinic acid and arsenobetaine. Optimized sample preparation conditions were applied to the extraction of arsenic in nine freeze-dried carrot samples. Total arsenic concentration in the carrot samples ranged from less than 20 ng g(-1) to 18.7 microg g(-1), dry mass. Extraction efficiency, defined as the ratio of the sum of individual arsenic species concentrations to total arsenic, ranged from 80 to 102% for freeze-dried carrots with arsenic concentrations greater than the limit of quantitation. Inorganic As(III) and As(v) were the only species found in samples that contained less than 400 ng g(-1) total arsenic. MMA and an unidentified arsenic compound were present in some of the samples with higher total arsenic content.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号