首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An on-line method capable of the separation of arsenic species was developed for the speciation of arsenite As(III), arsenate As(V), monomethylarsenic (MMA) and dimethylarsenic acid (DMA) in biological samples. The method is based on the combination of high-performance liquid chromatograph (HPLC) for separation, UV photo oxidation for sample digestion and hydride generation atomic fluorescence spectrometry (HGAFS) for sensitive detection. The best separation results were obtained with an anion-exchange AS11 column protected by an AG11 guard column, and gradient elution with NaH2PO4 and water as mobile phase. The on-line UV photo oxidation with 1.5% K2S2O8 in 0.2 mol L–1 NaOH in an 8 m PTFE coil for 40 s ensures the digestion of organoarsenic compounds. Detection limits for the four species were in the range of 0.11–0.15 ng (20 μL injected). Procedures were validated by analysis of the certified reference materials GBW09103 freeze-dried human urine and the results were in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of blood arsenic species with no need of sample pretreatment. Speciation of arsenic in blood samples collected from two patients after the ingestion of realgar-containing drug reveals slight increase of arsenite and DMA, resulting from the digestion of realgar.  相似文献   

2.
CZE for the speciation of arsenic in aqueous soil extracts   总被引:2,自引:0,他引:2  
We developed two separation methods using CZE with UV detection for the determination of the most common inorganic and methylated arsenic species and some phenylarsenic compounds. Based on the separation method for anions using hydrodynamic sample injection the detection limits were 0.52, 0.25, 0.27, 0.12, 0.37, 0.6, 0.6, 1.2 and 1.0 mg As/L for phenylarsine oxide (PAO), p-aminophenylarsonic acid (p-APAA), o-aminophenylarsonic (o-APAA), phenylarsonic acid (PAA), 4-hydroxy-3-nitrobenzenearsonic acid (roxarsone), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenite or arsenious acid (As(III)) and arsenate (As(V)), respectively. These detection limits were improved by large-volume sample stacking with polarity switching to 32, 28, 14, 42, 22, 27, 26 and 27 microg As/L for p-APAA, o-APAA, PAA, roxarsone, MMA, DMA, As(III) and As(V), respectively. We have applied both methods to the analysis of the arsenic species distribution in aqueous soil extracts. The identification of the arsenic species was validated by means of both standard addition and comparison with standard UV spectra. The comparison of the arsenic species concentrations in the extracts determined by CZE with the total arsenic concentrations measured by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) indicated that CZE is suited for the speciation of arsenic in environmental samples with a high arsenic content. The extraction yield of phenylarsenic compounds from soil was derived from the arsenic concentrations of the aqueous soil extracts and the total arsenic content of the soil determined by ICP-AES after microwave digestion. We found that 6-32% of the total amount of arsenic in the soil was extractable by a one-step extraction with water in dependence on the type of arsenic species.  相似文献   

3.
Le XC  Cullen WR  Reimer KJ 《Talanta》1994,41(4):495-502
An arsenic specific detection system utilizing on-line microwave digestion and hydride generation atomic absorption spectrometry (MD/HGAAS) is described for arsenic speciation by using high performance liquid chromatography (HPLC). Both ion exchange chromatography and ion pair chromatography have been studied for the separation of arsenite, arsenate, monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), and arsenobetaine (AB). When the commonly used mobile phases, phosphate and carbonate buffers at pH 7.5, are used on an anion exchange column, arsenite and AB co-elute. However, selective determination of these two arsenic compounds can be achieved by using the new detection system. Partial separation between arsenite and AB can be achieved by increasing the mobile phase pH to 10.3 and by using a polymer based anion exchange column. The detection limit obtained by using anion exchange chromatography with MD/HGAAS detection is approximately 10 ng/ml (or 200 pg for a 20-mul sample injection) for arsenite, DMAA and AB, 15 ng/ml (or 300 pg) for MMAA, and 20 ng/ml (or 400 pg) for arsenate. Complete separation of the five arsenic compounds is achieved on a reversed phase C18 column by using sodium heptanesulfonate as ion pair reagent. Comparable resolution between chromatographic peaks is obtained by using MD/HGAAS detection and inductively coupled plasma mass spectrometry (ICPMS) detection.  相似文献   

4.
Determination of arsenic species in marine samples by HPLC-ICP-MS.   总被引:1,自引:0,他引:1  
Arsenic speciation analysis in marine samples was performed using high performance liquid chromatography (HPLC) with ICP-MS detection. The separation of eight arsenic species viz. arsenite (As(III)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenate (As(V)), arsenobetaine, trimethylarsine oxide (TMAO), arsenocholine and tetramethylarsonium ion (TeMAs) was achieved on a Shiseido Capcell Pak C18 column by using an isocratic eluent (pH 3.0), in which condition As(III) and MMA were co-eluted. The entire separation was accomplished in 15 min. The detection limits for 8 arsenic species by HPLC/ICP-MS were in the range of 0.02 - 0.10 microg L(-1) based on 3sigma of blank response (n=9). The precision was calculated to be 3.1-7.3% (RSD) for all eight species. The method then successfully applied to several marine samples e.g., oyster, scallop, fish, and shrimps. For the extraction of arsenic species from seafood products, the low power microwave digestion was employed. The extraction efficiency was in the range of 52.9 - 112.3%. Total arsenic concentrations were analyzed by using the microwave acid digestion. The total arsenics in the certified reference materials (DORM-2 and TORT-2) were analyzed and agreed with the certified values. The concentrations of arsenics in marine samples were in the range 6.6 - 35.1 microg g(-1).  相似文献   

5.
A coupling between column liquid chromatography (LC) and atomic fluorescence spectrometry was developed for arsenic speciation. After separation, the compounds are oxidised on-line by UV irradiation, volatilised by hydride-generation and carried to the detector by a stream of argon. A combination of anion-exchange and hydrophobic interactions in a single column (Dionex AS7) was found suitable for the simultaneous separation of organic and inorganic species. Twelve compounds (arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, arsenocholine, trimethylarsine oxide, tetramethylarsonium ion and four arsenosugars) were separated using an acetate buffer and a nitric acid solution as mobile phases. Limits of detection are 4-22 pg. The technique was applied to three marine samples. Arsenobetaine was detected as the main species in all samples, with concentrations varying from 59 to 1947 ng(As) g(-1) of fresh mass.  相似文献   

6.
A sequential arsenic extraction method was developed that yielded extraction efficiencies (EE) that were approximately double those using current methods for terrestrial plants. The method was applied to plants from two arsenic contaminated sites and showed potential for risk assessment studies. In the method, plants were extracted first by 1:1 water-methanol followed by 0.1 M hydrochloric (HCl) acid. Total arsenic in plant and soil samples collected from contaminated sites was mineralized by acid digestion and detected by inductively coupled plasma-atomic emission spectrometry (ICP-AES) and hydride generation-atomic absorption spectrometry (HG-AAS). Arsenic speciation was done by high performance liquid chromatography coupled with HG-AAS (HPLC-HGAAS) and by HPLC coupled with ICP-mass spectrometry (HPLC-ICP-MS). Spike recovery experiments with arsenite (As(III)), arsenate (As(V)), methylarsonic acid (MA) and dimethylarsinic acid (DMA) showed stability of the species in the extraction processes. Speciation analysis by X-ray absorption near edge spectroscopy (XANES) demonstrated that no transformation of As(III) and As(V) occurred due to sample handling. Dilute HCl was efficient in extracting arsenic from plants; however, extraction and determination of organic species were difficult in this medium. Sequential extraction with 1:1 water-methanol followed by 0.1 M-HCl was most useful in extracting and speciating both organic and inorganic arsenic from plants. Trace amounts of MA and DMA in plants could be detected by HPLC-HGAAS aided by the process of separation and preconcentration of the sequential extraction method. Both organic and inorganic arsenic compounds could be detected simultaneously in synthetic gastric fluid extracts (GFE) but EEs by this method were lower than those of the sequential method. The developed sequential method was shown to be reliable and applicable to various terrestrial plants for arsenic extraction and speciation.  相似文献   

7.
High-performance liquid chromatography (h.p.l.c.) is used for separation of arsenite, arsenate, monomethylarsinate (MMA) and dimethylarsonate (DMA) followed by continuous sodium tetrahydroborate reduction and atomic absorption spectrometric detection. Sample preconcentration, offering improved detection limits for the individual species and the removal of matrix interferences, is achieved with a pellicular anion-exchange column. The arsenic species are then separated on a strong anion-exchange column placed in series with the preconcentration column. Detection limits of 2 ng (as arsenic) for arsenite, arsenate and MMA, and 1 ng for DMA. Results for arsenic species in soil waters and commercial bottle waters are given.  相似文献   

8.
A high performance liquid chromatography-microwave digestion-hydride generation-atomic absorption spectrometry (HPLC-MW-HG-AAS) coupled method is described for As(III), As(V), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB) and arsenocholine (AsC) determination. A Hamilton PRP-X100 anion-exchange column is used for carrying out the arsenic species separation. As mobile phase 17 mM phosphate buffer (pH 6.0) is used for As(III), As(V), MMA and DMA separation, and ultrapure water (pH 6.0) for AsB and AsC separation. Prior to injection into the HPLC system AsB and AsC are isolated from the other arsenic species using a Waters Accell Plus QMA cartridge. A microwave digestion with K(2)S(2)O(8) as oxidizing agent is used for enhancing the efficiency of conversion of AsB and AsC into arsenate. Detection limits achieved were between 0.3 and 1.1 ng for all species. The method was applied to arsenic speciation in fish samples.  相似文献   

9.
The potential of coupling anion-exchange high-performance liquid chromatography, hydride generation and atomic fluorescence spectrometry (HPLC–HG–AFS) for arsenic speciation is considered. The effects of hydrochloric acid and sodium tetrahydroborate concentrations on signal-to-background ratio, as well as argon and hydrogen flow rates, were investigated. Detection limits for arsenite, dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate were 0.17, 0.45, 0.30 and 0.38 μg l−1, respectively, using a 20-μl loop. Linearity ranges were 0.1–500 ng for As(III) and MMA (as arsenic), and 0.1–800 ng for DMA and As(V) (as arsenic). Arsenobetaine (AsB) was also determined by introducing an on-line photo-oxidation step after the chromatographic separation. In this case the limits of detection and linear ranges for the different species studied were similar to the values obtained previously for As(V). The technique was tested with a human urine reference material and a volunteer's sample. © 1998 John Wiley & Sons, Ltd.  相似文献   

10.
Tseng WC  Yang MH  Chen TP  Huang YL 《The Analyst》2002,127(4):560-564
An on-line and fully automated method was developed for the continuous and dynamic in vivo monitoring of four arsenic species [arsenite (AsIII), arsenate (AsV), monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA)] in urine of living organisms. In this method a microdialysis sampling technique was employed to couple on-line with high performance liquid chromatography (HPLC) and hydride generation atomic absorption spectrometry (HGAAS). Dialysates perfused through implanted microdialysis probes were collected with a sample loop of an on-line injector for direct and automated injection into HPLC system hyphenated with HGAAS. The saline (0.9% NaCl) solution was perfused at the rate of 1 microl min(-1) through the microdialysis probe and the dialysate was loaded into 50 microl of sample loop. The separation conditions were optimally selected to be in phosphate buffer solution at a pH 5.2 with a flow rate of 1.2 ml min(-1). The effluent from the HPLC was first mixed on-line at the exit of the column with HCl (1 M) solution and then mixed with a NaBH4 (0.2% m/v) solution. Based on the optimal conditions obtained, linear ranges of 2.5-50 ng ml(-1) for AsIII and 6.75-100 ng ml(-1) for the other three arsenic species were obtained. Detection limits of 1.00, 2.18, 1.03 and 2.17 ng ml(-1) were obtained for AsIII, DMA, MMA and AsV, respectively. Typical precision values of 3.4% (AsIII), 5.4% (DMA), 3.6% (MMA) and 7.5% (AsV) were obtained, respectively, at a 25 ng ml(-1) level. Recoveries close to 100%, relative to an aqueous standard, were observed for each species. The average in vivo recoveries of AsIII, DMA, MMA and AsV in rat bladder urine were 56+/-5%, 60+/-9%, 49+/-3% and 55+/-7%, respectively. The use of an on-line microdialysis-HPLC-HGAAS system permitted the determination of four urinary arsenic species in the bladder of an anesthetized rat with a temporal resolution of 50 min sampling.  相似文献   

11.
A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO(2)(2-), AsO(4)(2-), and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L(-1) sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 micromol L(-1) of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water.  相似文献   

12.
A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, whereas a bypass leads the flow directly to the HG-AFS system, performing inorganic arsenic determination. DMA concentration is calculated by the difference of total inorganic arsenic and measurement of the photo-oxidation step. The detection limits for DMA and inorganic arsenic were 0.09 and 0.47 μg L(-1), respectively. The repeatability values accomplished were of 2.4 and 1.8%, whereas the injection frequencies were 24 and 28 injections per hour for DMA and inorganic arsenic, respectively. This method was validated by means of a solid reference material BCR-627 (muscle of tuna) with good agreement with the certified values. Satisfactory results for DMA and inorganic arsenic determination were obtained in several water matrices. The proposed method offers several advantages, such as increasing the sampling frequency, low detection limits and decreasing reagents and sample consumption, which leads to lower waste generation.  相似文献   

13.
An improved analytical procedure is presented for the separation and simultaneous determination of hydride-forming (toxic) and not hydride-forming (non-toxic) arsenic species in human urine. Separation was performed by cation-exchange chromatography using a new solid phase type based on the continuous bed chromatography (CBC) technology. This column permits by a factor of 4 higher flow rates than conventional columns resulting in a drastical reduction of retention times without any loss of resolution. Using this type of column, arsenobetaine (AsBet), arsenocholine (AsChol), and dimethylarsinic acid (DMA) were separated from the more toxic arsenic species arsenous acid (As(III)), arsenic acid (As(V)), and methylarsonic acid (MA) within only 4 min. The HPLC system was coupled via a flow injection system and either a UV or a microwave (MW) reactor to the HG-AAS instrument. UV photolysis and MW digestion were used to transform AsBet and AsChol to hydride-forming species and to make them accessible to HG-AAS. UV photolysis turned out to be more suitable for this application than MW digestion, because the latter technique led to peak broadening and poorer performance. The described procedure was applied to the determination of arsenic species in urine samples of non-occupationally exposed persons before and 12 h after seafood consumption. Detection limits were about 1 μg/L for each arsenic species. After consumption, the AsBet and DMA excretion increased by at least a factor of 150 for AsBet and by a factor of 6 for DMA, respectively, while the excretion of the other species did not increase significantly. This invalidates the use of total urinary arsenic as well as total hydride-forming arsenic as an indicator for exposure to inorganic arsenic. Received: 12 August 1998 / Revised: 30 October 1998 / Accepted: 24 November 1998  相似文献   

14.
We describe a method for continuously monitoring both hydride- and nonhydride-forming arsenic species in 10-microL microdialysate samples by coupling together on-line high-performance liquid chromatography (HPLC), a post-column UV/TiO2 film reactor, and hydride generation (HG) inductively coupled plasma mass spectrometry (ICP-MS). To maximize the signal intensities of the desired arsenic species, we optimized the photocatalytic oxidation efficiency of the analyte species and used a rapid on-line pre-reduction process to convert the oxidized species into As(III) prior to HG-ICP-MS determination. The UV/nano-TiO2 film reactor was manufactured by coating nano-TiO2 onto the interior of a glass tube. Impregnation and sol-gel methods were employed to deposit the TiO2 films, and their effectiveness for the oxidation of organic arsenicals was compared. To enhance the decomposition efficiency of organic arsenicals, we investigated the effects of the acidity and the composition of the column effluent. Because of the improved HG efficiency toward the tested arsenicals and the adoption of a segmented flow technique to retain the peak resolution in our on-line LC-UV/nano-TiO2 film reactor-HG-ICP-MS instrument, the detection limits for arseneous acid [As(III)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenic acid [As(V)], and arsenobetaine (AsB) were all in the submicrogram-per-liter range (based on 3 sigma) for 10-microL injections. A series of validation experiments--analyses of certified reference urine and rabbit serum samples--indicated that these methods can be applied satisfactorily to the continuous determination of As(III), MMA, DMA, As(V), and AsB in blood and in the extracellular space of target organs.  相似文献   

15.
Arsenic speciation in freshwater organisms from the river Danube in Hungary   总被引:1,自引:0,他引:1  
Total arsenic and arsenic species were determined in a range of freshwater samples (sediment, water, algae, plants, sponge, mussels, frog and fish species), collected in June 2004 from the river Danube in Hungary. Total arsenic concentrations were measured by ICPMS and arsenic species were measured in aqueous extracts of the samples by ion-exchange HPLC-ICPMS. In order to separately determine the efficiency of the extraction method and the column recovery, total arsenic concentrations in the extracts were obtained in three ways: (i) ICPMS determination after acid digestion; (ii) flow injection analysis performed directly on the extract; (iii) the sum of arsenic species eluting from the HPLC column. Extraction efficiencies were low (range 10-64%, mean 36%), but column recovery was acceptable (generally >80%) except for the fish samples, where substantial, currently unexplained, losses were observed. The dominating arsenic species in the extracts of freshwater algae were arsenosugars, whereas arsenate [As(V)] was present only as a minor constituent. On the other hand, plant extracts contained only inorganic arsenic, except for two samples which contained trace amounts of dimethylarsinate (DMA) and the tetramethylarsonium cation (TETRA). The oxo-arsenosugar-phosphate (ca. 35% of extractable arsenic) and the oxo-arsenosugar-glycerol (ca. 20%) as well as their thio-analogues (1-10%) were found in the mussel extracts, while arsenobetaine (AB) was present as a minor species only. In general, fish extracts contained only traces of arsenobetaine, and the oxo-arsenosugar-phosphate was the major arsenic compound. In addition, samples of white bream contained thio-arsenosugar-phosphate; this is the first report of a thio-arsenical in a fish sample. The frog presented an interesting arsenic speciation pattern because in addition to the major species, arsenite [As(III)] (30%) and the tetramethylarsonium cation (35%), all three intermediate methylation products, methylarsonate (MA), dimethylarsinate and trimethylarsine oxide (TMAO), and arsenate were also present. Collectively, the data indicate that arsenobetaine, the major arsenical in marine animals, is virtually absent in the freshwater animals investigated, and this represents the major difference in arsenic speciation between the two groups of organisms.  相似文献   

16.
Flow injection analysis (FIA) and high-performance liquid chromatography double-focusing sector field inductively coupled plasma mass spectrometry (HPLC-DF-ICP-MS) were used for total arsenic determination and arsenic speciation of xylem sap of cucumber plants (Cucumis sativus L.) grown in hydroponics containing 2 μmol dm−3 arsenate or arsenite, respectively. Arsenite [As(III)], arsenate [As(V)] and dimethylarsinic acid (DMA) were identified in the sap of the plants. Arsenite was the predominant arsenic species in the xylem saps regardless of the type of arsenic treatment, and the following concentration order was determined: As(III) > As(V) > DMA. The amount of total As, calculated taking into consideration the mass of xylem sap collected, was almost equal for both treatments. Arsenite was taken up more easily by cucumber than arsenate. Partial oxidation of arsenite to arsenate (<10% in 48 h) was observed in the case of arsenite-containing nutrient solutions, which may explain the detection of arsenate in the saps of plants treated with arsenite.  相似文献   

17.
刘华琳  赵蕊  韦超  邢志  闫继仁  张新荣 《分析化学》2005,33(11):1522-1526
运用自行设计的接口,实现了高效液相色谱与原子吸收光谱的联用。通过对常见砷化合物进行形态分忻,考察了自行设计的高效液相色谱+紫外在线消解-氢化物发生原子吸收光谱联用(HPLC—UV—HGAAS)接口的性能。实现了将分离后不能直接用于氢化物发生的大分子,通过紫外“在线”消解成小分子砷化合物的目的。确定了仪器的最优化分析条件。建立了快速、直接、连续、在线的HPLC-UV-HGAAS元素形态分析方法。  相似文献   

18.
Changjin Wei 《Talanta》2007,73(3):540-545
A novel procedure was developed for the determination of arsenite (As(III)), arsenate (As(V)), monomethylarsonic (MMA) and dimethylarsinic acid (DMA) with ion chromatography-hydride generation-atomic fluorescence spectrometry (IC-HG-AFS) by employing a new gas-liquid separator (GLS). The effective separation of the four arsenic species was achieved in about 12 min. With a sample loading volume of 20 μl, the measurable minimum for As(III), DMA, MMA and As(V) were 0.02, 0.045, 0.043 and 0.166 ng, respectively, along with relative standard deviations of 1.1, 1.1, 1.7 and 2.2% at the 100 μg l−1 level (n = 6) for As(III), DMA, MMA and As(V), respectively. The present procedure was applied for the speciation of arsenic in underground water and in urine samples, and the sum of the four arsenic species by IC-HG-AFS was in good agreement with the total value by HG-AFS.  相似文献   

19.
Urinary arsenic speciation is considered to be an effective procedure to differentiate between toxic inorganic and less toxic organic arsenic exposure. The aim of the present work was to develop a new method for the simultaneous determination of the main arsenic species so far detected in urine: arsenite (As(III)), arsenate (As(V)), methylarsonic acid (MA), dimethylarsinic acid (DMA), and arsenobetaine (AsB). The method is based on anion exchange HPLC coupled on-line to an inductively coupled plasma mass spectrometer (ICP-MS) for element specific detection. Experimental parameters, such as column type and composition of the mobile phases were optimized in order to get best separation, little matrix interferences, lowest detection limits, and short total times of analyses. Best chromatographic conditions were obtained by using a Dionex AS14 anion exchange column and a gradient elution with tetramethylammonium hydroxide and ammonium carbonate as eluting compounds. The detection limits (3 σ) were found to be in the sub μg L–1 range. The method was applied to analyze different urine samples from persons with and without consumption of seafood. To avoid significant matrix influences, samples (24 h urine) had to be diluted 1 : 5 with water and were filtered through a 0.45 μm filter prior to analyses. Special attention was focused on the validation of the method according to the regulations of the “Deutsche Forschungsgemeinschaft” (DFG) for the analyses of hazardous substances in biological materials. Received: 22 December 1997 / Revised: 18 February 1998 / Accepted: 22 February 1998  相似文献   

20.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic (IC) detector for the speciation analysis of arsenic in edible oil. The arsenic species studied include arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine and arsenocholine. Gradient elution using (NH(4))(2)CO(3) and methanol at pH 8.5 allowed the chromatographic separation of all species in less than 8 min. Effluents from the IC column were delivered to the nebulizer of ICP-MS for the determination of arsenic. The concentrations of arsenic species have been determined in several used and fresh vegetable oil samples. In this study, a microwave-assisted extraction method was used for the extraction of arsenic species from oil samples. The extraction efficiency was better than 92% and the recoveries from spiked samples were in the range of 90-105%. The precision between sample replicates was better than 8% for all determinations. The limits of detection were in the range of 0.008-0.024 ng mL(-1) for various arsenic species based on peak height, which corresponded to 0.08-0.24 ng g(-1) in the original oil sample. The major arsenic species in the used oil samples varied based on the food items cooked.  相似文献   