首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report here an efficient and comprehensive analytical methodology based on gas chromatography with high resolution mass spectrometry (GC–HRMS) to simultaneously determine PBDEs from mono to deca brominated and hydroxy (OH-) and methoxy (MeO-) PBDE metabolites in environmental samples, particularly, sediment, fish tissue and milk. Among a number of extraction and clean-up methods tested, pressurized liquid extraction followed by gel permeation chromatography and florisil clean-up proved to be simple, robust and optimized so that all target analytes (parent compounds and metabolites) were collected in a single fraction. Extracts were analyzed by GC–HRMS to identify PBDEs. Following, the same extracts were derivatized and re-analyzed by GC–HRMS to determine 11 target and 35 non-target OH- and MeO-PBDEs. Monitoring of the M+ for MeO-PBDEs and the [M−CH2CO]+ ions for derivatized OH-PBDEs at 10,000 resolution permitted unequivocal identification of the PBDE metabolites in the environmental matrices examined. The method was validated in terms of accuracy, precision, detection limits and long-term stability. The analytical precision obtained with this method was between 0.3 and 17%, and the limits of quantification were lower than 3.28 pg/g dry weight, 20.5 and 41.4 pg/g lipid weight in sediment, milk and fish, respectively. The method was applied to determine PBDEs and target and non-target metabolites in all three matrices.  相似文献   

2.
A methodology for the simultaneous analysis of eight polybrominated diphenyl ethers (PBDEs); eight methoxylated PBDEs (MeO-PBDEs); and three emerging flame retardants, hexabromobenzene (HBB), pentabromoethyl benzene (PBEB), and decabromodiphenyl ethane (DBDPE) by gas chromatography coupled to tandem mass spectrometry (GC-MS-MS) was developed for two environmental matrices (sediment and sludge) and three biological matrices (fish, dolphin blubber, and bird eggs). The use of selective reaction monitoring (SRM) allows a high selectivity, which is critical in the analysis of complex samples like blubber. Analytical parameters such as linearity, reproducibility, or accuracy were evaluated. Method limits of detection and quantification were evaluated and compared with GC-EI-MS and GC-NCI-MS. Method detection limits were valid for the environmental analysis in all cases, with values between 0.01 and 1.65 ng/g dw for sediment, 0.05 and 2.78 ng/g dw for sludge, 0.04 and 10.6 ng/g lw for fish, 0.01 and 1.11 ng/g lw for dolphin blubber, and 0.03 and 3.20 ng/g lw for bird eggs. The developed method was applied to five samples of each matrix. PBDEs were detected in all samples, while MeO-PBDEs were only detected in dolphin blubber. DBDPE was detected in sediment and sludge.  相似文献   

3.
Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).  相似文献   

4.
Gas chromatography coupled to ion trap tandem mass spectrometry (GC–ITMS-MS) is proposed for the analysis of methoxylated polybrominated diphenyl ethers (MeO-PBDEs) in fish and shellfish. MS–MS operating parameters related to the isolation and fragmentation of the precursor ions were optimized to achieve maximum sensitivity and selectivity. This new method allows the determination of both MeO-PBDEs and PBDEs in a single run. Low limits of detection (0.4–2.5 pg injected) and high precision (RSD < 13%) were achieved. A sample treatment based on a selective pressurized liquid extraction (PLE) using Florisil as fat retainer was applied for the analysis of these compounds in fish samples. Method limits of quantification ranged from 0.11 to 0.95 ng g−1 lipid weight for MeO-PBDEs and between 0.18 and 0.50 ng g−1 lipid weight for PBDEs. In addition, good repeatability of the whole method was achieved (RSD < 15%). The suitability of the method was evaluated by analyzing a certified reference material (SRM 1945, whale blubber) with satisfactory results. The developed method was applied to the simultaneous analysis of MeO-PBDEs and PBDEs in fish and shellfish samples from the Mediterranean Sea.  相似文献   

5.
Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003–2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed.  相似文献   

6.
Y Wen  L Chen  J Li  Y Ma  S Xu  Z Zhang  Z Niu  J Choo 《Electrophoresis》2012,33(15):2454-2463
A simple and sensitive method for the simultaneous determination of four triazines from soil, strawberry, and tomato samples was developed by selective molecularly imprinted matrix solid-phase dispersion (MI-MSPD) coupled to micellar electrokinetic chromatography (MEKC). Using atrazine as template, the synthesized molecularly imprinted polymers (MIPs) were employed as the dispersion sorbent of MSPD to successfully extract atrazine and its analogs of simazine, ametryn, and propazine from the three different real samples, while matrix interferences were effectively eliminated simultaneously under the optimum extraction conditions. Excellent separation was achieved within 7 min by using an optimized buffer system composed of 30 mmol/L ammonium acetate, 20 mmol/L SDS, and 15% ACN at pH 9.45, obtained by orthogonal design. Good linearity was obtained in a range of 0.5-25 μg/g with the correlation coefficients R(2) ≥0.9991 except for strawberry sample within 1-25 μg/g, and limits of detection were between 12.9-31.5 ng/g in all the three samples. The average recoveries of the four triazines at three different spiked levels were ranged from 53.5 to 98.4% with the relative standard deviations of 1.28-4.89%. This method was proved convenient, costeffective, and environmental benign and could be used as an alternative tool to the existing methods for analyzing the residues of triazines in soil, fruit, and vegetable samples.  相似文献   

7.
建立了同时测定土壤中7种多溴联苯醚(PBDEs)的超声微波协同萃取/气相色谱测定方法.考察了萃取溶剂的种类和用量、微波功率、萃取时间等因素对模拟土壤中PBDEs回收率的影响,得到了最佳萃取条件:萃取剂为50 mL正己烷-丙酮(1:1),微波辐射功率为90W,萃取时间为10 min.在最佳条件下,PB-DEs在10~40...  相似文献   

8.
建立了磁性聚亚苯基共轭微孔聚合物富集/表面增强拉曼光谱法测定水样和土壤中4种多环芳烃的分析方法。待测物经磁性聚亚苯基共轭微孔聚合物吸附萃取,甲醇洗脱后进行SERS检测。结果表明,蒽、芘、荧蒽和苯[α]芘在0.1~10μg/L范围内与其SERS特征峰峰强呈良好的线性关系,检出限为0.03μg/L,回收率为71.6%~115.8%,相对标准偏差不大于13.7%。该分析方法灵敏度高,能够满足实际水样和土壤中4种多环芳烃同时检测的要求。  相似文献   

9.
Cai Z  Jiang G 《Talanta》2006,70(1):88-90
Soil samples collected from an electronic waste recycling site were prepared by using Soxhlet extraction and multiple-step column chromatographic clean-up. Gas chromatography/ion trap mass spectrometry method was developed to determine polybrominated diphenyl ethers (PBDEs) in the sample extracts. The method performance was evaluated by the recovery of 13C-labeled internal standards and by analyzing quality assurance and quality control samples. Relative error and relative standard deviation obtained from the analysis of duplicated samples and spiked matrix were better than 10%. PBDEs were detected in the field soil samples collected from an e-wastes disposal site at levels from low parts-per-billions to 600 parts-per-billions.  相似文献   

10.
Polybrominated diphenyl ethers (PBDEs) are a group of persistent organic pollutants. They are used as flame retardants in plastics, paints, varnishes and textile materials. PBDEs pose great risk to the environment because of their high persistence and ability to get into the environment easily due to the lack of chemical bonds with the matrix of materials, to which they are added. Global research studies confirmed the occurrence of those compounds in the majority of elements of water and land environment. Analysis of PBDEs in environmental samples is one of the specific analytical methods of criteria that comprise low detection limits and high selectivity. The analysis of PBDEs in environmental samples is one of the specific analytical methods, in which the main criteria are low detection limits and high selectivity. In this article, a literature review of methods for environmental sample preparation and analysis of the PBDE content was presented. The article discusses the potential of modern extraction techniques such as: solid-phase microextraction, single-drop microextraction, dispersive liquid-liquid microextraction, microwave-assisted extraction, cloud point extraction, hollow fibre-liquid phase microextraction and others for the separation of PBDEs from environmental samples with a complex matrix. Among the methods for qualitative and quantitative determination of PBDEs, a particular focus was put on gas chromatography/mass spectrometry with various injection techniques and different types of sample ionisation.  相似文献   

11.
A gas chromatography/ion trap mass spectrometry (GC/ITMS) method was developed for the determination of polybrominated diphenyl ethers (PBDEs). ITMS parameters were optimized in order to achieve the best sensitivity for the PBDE analysis. Tandem mass spectrometry, along with an isotope dilution internal standard method, was used for the quantitation. Chromatographic windows were developed for mono- to hepta-BDEs, depending on the retention times when a 30-m GC column was used. A different 15-m column was used to analyze deca-BDE. Environmental soil samples collected from an electronic waste recycling site were prepared by using Soxhlet extraction and column chromatographic cleanup. Average recoveries of 61-118% were obtained for the 13C-labeled PBDE internal standards spiked in the samples prior to sample preparation. The accuracy represented by relative analytical errors was -24% to 18%, and the precision (relative standard deviation) was 11-26% (n=8). The method detection limits ranged from 0.013-0.25 ng/g for the PBDEs in soil.  相似文献   

12.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction (SBSE) for the analysis of 51 persistent organic pollutants including organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and polybrominated diphenylethers (PBDEs) in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, solvent volume, mass of soil, and extraction time, and the partitioning from the solvent/water mixture to the PDMS were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of SBSE for 14 h at 900 rpm. The stir bars were analyzed by thermal desorption-GC-mass spectometry (TD-GC-MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials (CRMs). The main advantage of this method resides in the fact that a small amount of a nontoxic solvent (methanol) is needed for the extraction of only 1 g of solid sample allowing LODs ranging from 0.01 to 2.0 microg/kg. Repeatability and reproducibility variations were lower than 20% for all investigated compounds. Results of the CRMs verify the high accuracy of this method.  相似文献   

13.
A viable approach for the analysis of polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in sewage sludge samples is presented in this paper. The proposed method combines ultrasound-assisted extraction (UAE) of the solid sample and headspace solid-phase microextraction (HS-SPME) of the obtained extract, followed by gas chromatography coupled to tandem mass spectrometry (GC-MS-MS) analysis. Different parameters affecting the extraction process are evaluated and optimized. The addition of a small amount of Florisil to the sample during UAE provides a significant improvement of the chromatographic background and, at the same time, a much more efficient HS-SPME. Extensive method validation is performed using real sewage sludge samples. The proposed method exhibits good performance in terms of linearity and precision, with recoveries exceeding 92% and limits of detection in the sub ng g(-1) level. Practical applicability is demonstrated through the analysis of real contaminated sewage sludge and sediment samples in which some of the target PBDEs are detected and quantified. This proposed combined methodology represents a large time-saving when compared to other classic multi-step solvent extraction methods and it constitutes a suitable approach for the analysis of the target compounds in environmental complex solid samples.  相似文献   

14.
The performance of matrix solid-phase dispersion (MSPD) for the extraction of polycyclic aromatic hydrocarbons (PAHs) in fish tissue is described. The suitability of different solid supports was tested as well as the influence on the extraction efficiency of the natural fat content in samples. Under optimal conditions 0.6-0.8 g of tissue sample, are dispersed with 2 g of octadecylsiloxane (C18) and 0.5 g of anhydrous sodium sulphate and transferred to the top of a polyethylene solid-phase extraction cartridge which already contains 2 g of florisil and 1 g of C18. Cartridges were eluted with acetonitrile. The analysis of the extracts was carried out by high-performance liquid chromatography (HPLC) coupled with fluorescence detection. The proposed method provides detection limits between 0.04 and 0.32 ng/g for the different considered PAHs, below the maximum levels established by the some regulatory bodies for the six PAHs after recent oil spill episodes and European Union regulations. Recoveries over 80% were obtained for all compounds. Accuracy validation was carried out using the US National Institute of Standards and Technology (NIST) SRM 2977 reference material.  相似文献   

15.
母乳中多种含卤持久性有机污染物的联合检测方法   总被引:1,自引:0,他引:1  
建立了母乳中多种含卤持久性有机污染物(POPs)的联合检测方法,目标化合物主要包括六溴环十二烷(HBCDs)、多溴联苯醚(PBDEs)、多氯联苯(PCBs)和有机氯农药(OCPs)等.样品的前处理采用液液萃取、凝胶渗透色谱(GPC)净化和固相萃取(SPE)等技术,目标化合物经气相色谱-质谱联用仪(GC-MS)、液相色谱-三重四极杆串联质谱联用仪(LC-MS/MS)和气相色谱-三重四极杆串联质谱联用仪(GC-MS/MS)等进行检测.样品通过GPC除去脂肪,然后经SPE柱进一步净化并进行多组分分离,极大程度地减小了生物样品中复杂基质的干扰,适合样品量相对较小的人体样本中多种超痕量POPs的分析.应用灵敏度高、选择性更好的GC-MS/MS对样品中的PCBs和OCPs等进行分析,进一步降低基质的干扰.方法经过小牛血清加标实验验证,稳定可靠.POPs的加标回收率分别为88.7%~98.8%(PBDEs), 88.5%~92.5%(HBCDs), 67.9%~82.3%(PCBs)和81.7%~116.1%(OCPs),方法检出限分别为0.13~1.8 pg/mL(PBDEs), 0.31~1.2 pg/mL(HBCDs), 0.22~1.4 pg/mL(PCBs)和0.20~1.5 pg/mL(OCPs).采用本方法对潍坊地区20例母乳样品进行分析,结果显示,潍坊市母乳中HBCDs, PBDEs, PCBs、HCHs和DDTs的中值浓度分别为2.86, 7.76, 8.84、140和503 ng/g 脂重,此浓度水平与国内其它地区人群相当.  相似文献   

16.
Su R  Wang X  Xu X  Wang Z  Li D  Zhao X  Li X  Zhang H  Yu A 《Journal of chromatography. A》2011,1218(31):5047-5054
The multiwall carbon nanotubes (MWCNTs)-based matrix solid phase dispersion (MSPD) was applied for the extraction of hormones, including 17-α-ethinylestradiol, 17-α-estradiol, estriol, 17-β-estradiol, estrone, medroxyprogesterone, progesterone and norethisterone acetate in butter samples. The method includes MSPD extraction of the target analytes from butter samples, derivatization of hormones with heptafluorobutyric acid anhydride-acetonitrile mixture, and determination by gas chromatography-mass spectrometry. The mixture containing 0.30 g graphitized MWCNTs and 0.10 g MWCNTs was selected as absorbent. Ethyl acetate was used as elution solvent. The elution solvent volume and flow rate were 12 mL and 0.9 mL min(-1), respectively. The recoveries of hormones obtained by analyzing the five spiked butter samples were from 84.5 to 111.2% and relative standard deviations from 1.9 to 8.9%. Limits of detection and quantification for determining the analytes were in the range of 0.2-1.3 and 0.8-4.5 μg kg(-1), respectively. Compared with other traditional methods, the proposed method is simpler in the operation and shorter in the sample pretreatment time.  相似文献   

17.
We propose an instrumental method based on liquid chromatography coupled to negative ion-spray ionization (ISP(-)) tandem mass spectrometry (MS/MS), for the simultaneous analysis of eight hydroxylated brominated diphenyl ethers (OH-PBDEs) in four different environmental matrices (soil, fish, sludge and particulate matter). The reversed-phase chromatographic separation was performed on a 50 mm Xbridge C18 column, and the compounds were well resolved with a gradient consisting of a ternary mixture of 5 mMammonium acetate, methanol and acetonitrile. Detection was performed in the multiple reaction monitoring (MRM) mode using the [M - H](-) ion as base peak. The fragmentation pathways of the OH-PBDEs varied according to the hydroxyl substitution in the benzene rings and produced characteristic MRM transitions needed for resolving isomeric compounds. The method is acceptable for quantification in the high picogram per gram dry weight (dw) level for all matrices analyzed. Repeatability and reproducibility tested at 75 pg microl(-1) were below 10% using internal standard quantification. The ISP (-) enhancement due to matrix effects was in the 76-132% range and the highest values corresponded to sludge samples. The use of the proposed method based on LC-ISP(-)-MS/MS opens a new way to directly determine OH-PBDEs without the need of derivatization.  相似文献   

18.
A novel method for the analysis of four polybrominated diphenyl ethers (PBDEs) in environmental and human serum samples based on hollow fiber-liquid phase microextraction (HF-LPME) followed by gas chromatography-inductively coupled plasma mass spectrometric (GC-ICP-MS) detection has been developed. The organic solvent in the porous hollow fiber was first dipped into the sample for extraction at a given time, and the retracted organic phase was introduced into the GC-ICP-MS for analysis. The addition of methanol has a strong effect on the HF-LPME extraction efficiency. Other significant parameters affecting the extraction efficiency of HF-LPME were also studied. HF-LPME was effective to isolate the analytes from the complex matrix. Under the optimized conditions, the detection limits of the proposed method varied from 15.2 to 40.5 ng/L. In general, the relative standard deviations (RSDs) were less than 10%. Good linearity was obtained with the correlation coefficients all better than 0.999. The proposed method is simple, quick, few microliters of organic solvent required, and is especially suitable for the analysis of the real sample with small amount available. The overall process of HF-LPME with GC-ICP-MS was applied successfully for the determination of polybrominated diphenyl ethers (PBDEs) in environmental and spiked human serum samples, and the results were satisfactory.  相似文献   

19.
20.
A fast sample pretreatment method was developed to determine polybrominated diphenyl ethers (PBDEs) in polymers from waste electrical and electronic equipment (WEEE). Polymers were firstly prepared into "polymer film" to facilitate a complete Soxtec extraction. Then, three extraction parameters (including hot plate temperature, boiling time, and rinsing time) were optimized based on the recovery of target in reference polymer samples. The proposed method was successfully applied to the analysis of PBDEs in standard plastic materials from WEEE and the extraction yields of PBDEs ranged from 78.9% to 91.3%. The detection limits of PBDEs were 0.05–0.10 µg/g, indicating this method can be used as a quality assurance and quality control procedure of PBDEs in the production of electrical and electronic equipment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号