首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Low-pressure gas chromatography-mass spectrometry (LP-GC-MS) using a quadrupole MS instrument was further optimized and evaluated for the fast analysis of multiple pesticide residues in food crops. Performance of two different LP-GC-MS column configurations was compared in various experiments, including ruggedness tests with repeated injections of pesticides in matrix extracts. The tested column configurations employed the same 3 m x 0.15 mm i.d. restriction capillary at the inlet end, but different analytical columns attached to the vacuum: (A) a 10 m x 0.53 mm i.d., 1 microm film thickness RTX-5 Sil MS column; and (B) a 10 m x 0.25 mm i.d., 0.25 microm film thickness DB-5MS column. Under the optimized conditions (compromise between speed and sensitivity), the narrower analytical column with a thinner film provided slightly (<1.1-fold) faster analysis of <5.5 min separation times and somewhat greater separation efficiency. However, lower detection limits for most of the tested pesticides in real extracts were achieved using the mega-bore configuration, which also provided significantly greater ruggedness of the analysis (long-term repeatability of analyte peak intensities, shapes, and retention times). Additionally, the effect of the increasing injection volume (1-5 microl) on analyte signal-to-noise ratios was evaluated. For the majority of the tested analyte-matrix combinations, the increase in sensitivity caused by a larger injection did not translate in the same gain in analyte detectability. Considering the costs and benefits, the injection volume of 2-3 microl was optimal for detectability of the majority of 57 selected pesticides in apple, carrot, lettuce, and wheat extracts.  相似文献   

2.
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 microm film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 microm film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 microg L(-1) for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 microg L(-1). The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled.  相似文献   

3.
Innovative features and technical improvements in modern bench-top quadrupole gas chromatograph-mass spectrometer (GC-MS) have prepared the way for faster and more cost-effective applications while still maintaining sufficient chromatographic resolution, speed of MS data acquisition and reliability of analytical methodology. In this paper, a short wide-bore capillary column with low film thickness (5 m x 0.32 mm i.d., 0.1 microm) was used a pre-fractionating column and only chosen heart-cuts were transferred to the second chromatographic dimension (15 m x 0.25 mm i.d., 0.25 microm) by means of a pressure-adjusted continual flow type switching device for quantification of five common amphetamine-type stimulant drugs. The instrumental setting used, in combination with carefully optimized operational fast GC and MS parameters, markedly decreased the retention times of the targeted analytes, e.g., amphetamine 0.891 min and methamphetamine 1.037 min, and the total chromatographic runtime (1.700 min), as well as reducing the need for continuous cleaning of the MS ion source and increasing column life compared with conventional GC-MS approaches. The performance of the instrumental configuration and analytical method was evaluated in validation experiments and the method was also applied to authentic samples. The method demonstrates the potential of fast GC-MS in combination with a gas-phase microfluidic Deans switch device for analysing of (semi)volatile compounds, such as amphetamine-type stimulant (ATS) drugs. This should be particularly useful in modern laboratories aiming at cost-efficient analysis as well as the optimum use of available laboratory capacity and instrumentation.  相似文献   

4.
外标归一化气相法测定天然气组成   总被引:2,自引:0,他引:2  
赵书云 《色谱》2002,20(6):587-590
 对SP 6000天然气分析仪的气路系统作了改进,实现了仪器自身标定。采用填充柱和毛细管柱分离,热导检测器和火焰电离检测器双检测器检测,外标 归一化法定量,简易、快速地测定了天然气组成。方法的准确度及精密度均符合气相法定量分析的要求。  相似文献   

5.
色谱与色谱/质谱法相结合分析热裂解汽油C9馏分   总被引:3,自引:0,他引:3  
王华  刘文民  徐媛  关亚风 《色谱》2006,24(6):615-618
采用毛细管气相色谱-氢火焰离子化检测器(CGC-FID)和气相色谱-质谱法(GC/MS)分析了热裂解汽油C9 馏分的组成。实验使用PONA毛细管气相色谱柱(100 m×0.25 mm i.d.×0.5 μm),根据烃类化合物在PONA柱上的保留规律,以正构烷烃标样保留值作为碳数分布依据,定量分析了裂解汽油C9 馏分中烃类化合物的碳数分布和单体烃含量;用GC/MS联用技术和CGC保留值定性法相结合对裂解汽油C9 馏分中相对含量大于0.2%的39种化合物进行了定性。  相似文献   

6.
In the present study, we developed a liquid chromatography-diode array detector-electrospray ionization/mass spectrometric (LC-DAD-ESI/MS) method for analysis of saikosaponins in Bupleurum falcatum. The LC method employed a ZORBAX SB-Aq analytical column (150 x 4.6 mm i.d., 5 μm) at a flow rate of 0.8 mL/min coupled with a diode array detector at 204 nm. A step gradient of acetonitrile-water (v/v) containing 0.5% formic acid from 30 to 70% was applied, leading to a sample analysis time of 30 min. The ESI-MS was carried out in positive and negative modes from 500 to 1,500 m/z. Saikosaponins c, a, and d gave strong sodium adducts at m/z 949.6, 803.5 and 803.6, respectively, in positive mode. The data indicate that the present LC-DAD-ESI/MS assay is an effective method for the determination of saikosaponins c, a and d from the roots of Bupleurum falcatum.  相似文献   

7.
Important parameters to consider when developing a liquid chromatography/mass spectrometry (LC/MS) method are buffer type and concentration, and column geometry. In the work presented here the choice of buffer for the analysis of basic compounds using a polar embedded phase (HyPURITYtrade mark ADVANCE) is illustrated for the analysis of tricyclic antidepressants. Method transfer from a 4.6 mm i.d. column to a 2.1 mm i.d. column is demonstrated for the analysis of triazines and anabolic steroids and their metabolites, with no change in selectivity and with added speed of analysis. Analysis of eight beta-blockers is achieved in 65 seconds by using a short 30 x 4.6 mm C18 column.  相似文献   

8.
魏泱  郭亮  丁明玉 《色谱》2001,19(6):520-522
采用二醇基柱分离、蒸发光散射检测法测定了饮料中的糖。比较了乙腈-水、二氯甲烷-甲醇两种流动相分析糖的特点。采用二氯甲烷-甲醇为流动相,果糖、葡萄糖、蔗糖、麦芽糖和棉子糖的峰面积与绝对进样量的标准曲线在绝对进样量为1.6μg-40μg时均具有良好的线性关系。该方法对上述5种糖的检测限分别为0.20μg,0.16μg,0.16μg,0.20μg和0.20μg。  相似文献   

9.
王晓春  王涵文  马继平  徐烨  关亚风 《色谱》2004,22(2):101-105
首次将填充毛细管高效液相色谱-毛细管气相色谱在线联用技术(μ-HPLC-CGC)用于分离分析八角茴香果实的挥发油成分。液相色谱选用氰基分析柱(250 mm×0.32 mm i.d.),正己烷-乙腈-二氯甲烷(体积比为80∶8∶12)为流动相,对挥发油样品做族组分分离,得到的5个族组分被依次存放在多位储存接口内,然后不分流分别转入毛细管气相色谱仪做详细分析。气相色谱柱由10 m×0.53 mm i.d.保留间隔柱和30 m×0.53 mm i.d.×1.0 μm SE-54分析柱组成。采用了不分流柱内进样模  相似文献   

10.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

11.
12.
New improved types of analytical columns Zorbax Eclipse XDB-C18 (75 mm x 4.6 mm i.d., 3.5 microm) and Zorbax Eclipse XDB-C18 (50 mm x 4.6 mm i.d., 1.8 microm) have been tested for determination of estradiol (active substance), methylparaben, propylparaben (preservatives) and estrone (degradation product) and compared with the conventional C18 columns (250 mm x 3.0 mm i.d., 5.0 microm). The Zorbax columns differ with their particle size, column length and ODS (octadecylsilica) type as well. Higher flow-rates (up to about 2.5 ml min(-1)) could be applied regardless to back-pressure. The analysis - previously done at 40 degrees C - could be performed even at ambient temperature. Analytical run was shortened to 3.5 min (from 12 min used for the conventional C18 column) with the same or better retention characteristics. System suitability data for all Zorbax columns show the advantages of these columns for the practical use in routine quality control of pharmaceuticals, particularly from the point of view of speed of analysis and solvent consumption.  相似文献   

13.
Ketoconazole, an imidazole-piperazine compound, is an orally active antimycotic agent. In addition, ketoconazole is a specific inhibitor of cytochrome P450 3A4. As about 60% of oxidized drugs are biotransformed by this isoform, the potential effect of a concomitant administration of ketoconazole on drug disposition may be of interest during drug development. The present paper describes three different approaches (methods A, B, and C) to attain high-throughput sample preparation and analysis in the quantification of ketoconazole in human plasma. Method A consisted of acetonitrile precipitation in a 96-well plate, transfer of the supernatant via a Tomtec Quadra 96 Model 320, and subsequent injection onto a 50 x 4.6 mm (i.d.) Develosil Combi-RP-5 column (packed with C30 bonded silica particles). Method B consisted of an identical sample preparation to method A with the exception that a Michrom Magic Bullet(trade mark) column, 2.0 --> 0.50 mm (i.d., tapered bore) x25 mm length, was used. Lastly, in method C, a turbulent-flow chromatography (TurboFlow LC/APCI-MS/MS) module was used for the direct analysis of ketoconazole in human plasma. A Sciex API 3000 was used in methods A and B, while a Micromass Quattro LC was employed in method C. Based on the values obtained for the calibrator (standard) and quality control samples, all three protocols yielded satisfactory accuracy, precision, and reduced manual sample preparation time.  相似文献   

14.
A fast method of analysis for 20 representative pesticides was developed using low-pressure gas chromatography-mass spectrometry (LP-GC-MS). No special techniques for injection or detection with a common quadrupole GC-MS instrument were required to use this approach. The LP-GC-MS approach used an analytical column of 10 m x 0.53 mm I.D., 1 microm film thickness coupled with a 3 m x 0.15 mm I.D. restriction capillary at the inlet end. Thus, the conditions at the injector were similar to conventional GC methods, but sub-atmospheric pressure conditions occurred throughout the analytical column (MS provided the vacuum source). Optimal LP-GC-MS conditions were determined which achieved the fastest separation with the highest signal/noise ratio in MS detection (selected ion monitoring mode). Due to faster flow-rate, thicker film, and low pressure in the analytical column, this distinctive approach provided several benefits in the analysis of the representative pesticides versus a conventional GC-MS method, which included: (i) threefold gain in the speed of chromatographic analysis; (ii) substantially increased injection volume capacity in toluene; (iii) heightened peaks with 2 s peak widths for normal MS operation; (iv) reduced thermal degradation of thermally labile analytes, such as carbamates; and (v) due to larger sample loadability lower detection limits for compounds not limited by matrix interferences. The optimized LP-GC-MS conditions were evaluated in ruggedness testing experiments involving repetitive analyses of the 20 diverse pesticides fortified in a representative food extract (carrot), and the results were compared with the conventional GC-MS approach. The matrix interferences for the quantitation ions were worse for a few pesticides (acephate, methiocarb, dimethoate, and thiabendazole) in LP-GC-MS, but similar or better results were achieved for the 16 other analytes, and sample throughput was more than doubled with the approach.  相似文献   

15.
We developed and evaluated a new method of low-pressure gas chromatography-tandem mass spectrometry (LP-GC/MS-MS) using a triple quadrupole instrument for fast analysis of 150 relevant pesticides in four representative fruits and vegetables. This LP-GC (vacuum outlet) approach entails coupling a 10 m, 0.53 mm i.d., 1 μm film analytical column between the MS transfer line and a 3 m, 0.15 mm i.d. capillary at the inlet. The MS creates a vacuum in the 10 m analytical column, which reduces the viscosity of the He carrier gas and thereby shifts the optimal flow rate to greater velocity. By taking advantage of the H(2)-like properties of He under vacuum, the short analytical column, a rapid oven temperature ramp rate, and the high selectivity and sensitivity of MS/MS, 150 pesticides were separated in <6.5 min. The 2.5 ms dwell time and 1 ms interscan delay of the MS/MS instrument were critical for achieving >8 data points across the 2-3 s wide peaks. To keep dwell and cycle times constant across all peaks, each segment consisted of 30 analytes (60 transitions). For assessment, we injected extracts of spiked broccoli, cantaloupe, lemon, and sweet potato from the updated QuEChERS sample preparation method. Average recoveries (n=72) were 70-120% for 144 of the pesticides, and reproducibilities were <20% RSD for all but 4 analytes. Also, detection limits were <5 ng/g for all but a few pesticides, depending on the matrix. In addition to high quality performance, the method gave excellent reliability and high sample throughput, including easy peak integration to obtain rapid results.  相似文献   

16.
A simple and sensitive LC-ESI/MS/MS method is developed and evaluated to determine the concentrations of roxithromycin in human serum. Serum proteins are precipitated with methanol with clarithromycin as the internal standard. In order to reduce the pollution of sample, after vortex mixing and centrifugation, the supernatants are diluted with mobile phase before analysis on a Phenomenex Luna CN column (100 mm × 2.0mm i.d., 3 μm). The mobile phase composes of methanol, acetonitrile and 0.1% formic acid and 0.1% ammonium acetate in water (3: 3: 4, v/v/v) at a flow rate of 0.2 mL/min. The linearity ranges from 10 to 20480 ng/mL. The extraction recoveries of roxithromycin range from 97 to 101%. The method is successfully used to pharmacokinetic study of roxithromycin after an oral administration dose of 300 mg roxithromycin tablets to 20 healthy volunteers.  相似文献   

17.
Ma S  Chen L  Luo G  Ren K  Wu J  Wang Y 《Journal of chromatography. A》2006,1127(1-2):207-213
A comprehensive two-dimensional liquid chromatography system was constructed on the combination of size exclusion chromatography (SEC) and reverse phase liquid chromatography (RPLC). The first dimension used a SEC column with 300 mm x 8mm i.d., packed with Toyopearl HW-40S. The column was eluted with 0.05 mol/l Tris-HCl (pH 6.9) at a flow rate of 0.4 ml/min. The second dimension used a RPLC column with 100 mm x 4.6mm i.d., which was operated in gradient form at a flow rate of 1.0 ml/min. An automatic switching valve was used to collect the effluent of the SEC column every 3 min, and the effluent was automatically injected into the RPLC column. Mass spectrometer was used for peak identification. This system was used to separate Qingkailing injection, a traditional Chinese medicine (TCM). The result showed that the total peak capacity of this system could reach 1134 and the qualitative analysis of seven chemical components of the Qingkailing injection was accomplished by this system. The results show that comprehensive two-dimensional liquid chromatography system is of great importance and high value in the separation of complex TCM.  相似文献   

18.
对一种分离测定氨基酸方法的改进   总被引:21,自引:4,他引:17  
陈永波  程群  饶斌  覃兰 《色谱》2001,19(6):560-563
 对Waters公司采用 6 氨基喹啉 N 羟基琥珀酰亚胺基 氨基甲酸酯 (AccQ Tag)柱前衍生化测定氨基酸的方法进行了改进。将流动相流速由原来的 1 0mL/min改变为 2 0mL/min ,用AccQ Tag专用柱 (3 9mmi.d .× 15 0mm ,4μm)在 17 5min(原为 35min) (运行周期为 2 2 5min ,原为 45min)内快速分离测定了 18种氨基酸和牛磺酸。用Nova PakC18柱 (3 9mmi.d .× 15 0mm ,4μm) ,Nova PakC18柱 (4 6mmi.d .× 15 0mm ,4μm) ,SymmetryC18柱 (3 9mmi.d .× 15 0mm ,4μm)和WatersXterraRP 18柱等反相C18柱代替AccQ Tag专用柱 ,均可对氨基酸进行快速分离。  相似文献   

19.
丙烯腈中微量杂质的毛细管色谱法分析   总被引:3,自引:0,他引:3  
孙云鹏  孙传经 《色谱》1997,15(1):83-84
提出了一种分析丙烯腈中微量杂质的大孔径OV-101和OV-17SCOT串联柱及毛细管进样系统。结果表明串联柱具有寿命长和分离效率高的特点,定量分析误差小于4%。  相似文献   

20.
高效液相色谱/四极杆-飞行时间质谱测定神经性贝毒   总被引:3,自引:0,他引:3  
方晓明  唐毅锋  刘俊平 《色谱》2004,22(1):20-23
采用高效液相色谱/四极杆 飞行时间质谱(HPLC/Q TOFMS)联用技术对贝类样品中的短裸甲藻毒素 PbTx-2 进行了检测研究。样品经丙酮提取、C18小柱净化后,用Zorbax XDB C18色谱柱(2.1 mm i.d.×150 mm,3.5 μ m)进行分离,流动相为甲醇 水(体积比为85∶15)溶液(含0.5 mmol/L NH4Ac),流速0.20 mL/min 。电喷雾正离子模式,选择质子化PbTx 2分子离子 [M+H] +作为前体离子进行TOFMS扫描、测定。结果表明,样品的平均加标  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号