首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An open tomograph to image volume regions near the surface of large objects is described. The central achievement in getting such a tomograph to work is the design of a fast two-dimensional pure phase encoding imaging method to produce a cross-sectional image in the presence of highly inhomogeneous fields. The method takes advantage of the multi-echo acquisition in a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence to significantly reduce the experimental time to obtain a 2D image or to spatially resolve relaxation times across the sensitive volume in a single imaging experiment. Depending on T(2) the imaging time can be reduced by a factor of up to two orders of magnitude compared to the one needed by the single-echo imaging technique. The complete echo train decay has been also used to produce T(2) contrast in the images and to spatially resolve the T(2) distribution of an inhomogeneous object, showing that variations of structural properties like the cross-link density of rubber samples can be distinguished by this method. The sequence has been implemented on a single-sided sensor equipped with an optimized magnet geometry and a suitable gradient coil system that provides two perpendicular pulsed gradient fields. The static magnetic field defines flat planes of constant frequency parallel to the surface of the scanner that can be selected by retuning the probe frequency to achieve slice selection into the object. Combining the slice selection obtained under the presence of the static gradient of the open magnet with the two perpendicular pulsed gradient fields, 3D spatial resolution is obtained.  相似文献   

2.
Eddy currents are inevitably induced when time-varying magnetic field gradients interact with the metallic structures of a magnetic resonance imaging (MRI) scanner. The secondary magnetic field produced by this induced current degrades the spatial and temporal performance of the primary field generated by the gradient coils. Although this undesired effect can be minimized by using actively and/or passively shielded gradient coils and current pre-emphasis techniques, a residual eddy current still remains in the MRI scanner structure. Accurate simulation of these eddy currents is important in the successful design of gradient coils and magnet cryostat vessels. Efficient methods for simulating eddy currents are currently restricted to cylindrical-symmetry. The approach presented in this paper divides thick conducting cylinders into thin layers (thinner than the skin depth) and expresses the current density on each as a Fourier series. The coupling between each mode of the Fourier series with every other is modeled with an inductive network method. In this way, the eddy currents induced in realistic cryostat surfaces by coils of arbitrary geometry can be simulated. The new method was validated by simulating a canonical problem and comparing the results against a commercially available software package. An accurate skin depth of 2.76 mm was calculated in 6 min with the new method. The currents induced by an actively shielded x-gradient coil were simulated assuming a finite length cylindrical cryostat consisting of three different conducting materials. Details of the temporal-spatial induced current diffusion process were simulated through all cryostat layers, which could not be efficiently simulated with any other method. With this data, all quantities that depend on the current density, such as the secondary magnetic field, are simply evaluated.  相似文献   

3.
A pulsed field gradient stimulated spin-echo NMR sequence is combined with imaging methods to spatially resolve velocity distributions and to measure 2D velocity maps ex situ. The implementation of these techniques in open sensors provides a powerful non-invasive tool to measure molecular displacement in a large number of applications inaccessible to conventional closed magnets. The method is implemented on an open tomograph that provides 3D spatial localization by combining slice selection in the presence of a uniform static magnetic field gradient along the depth direction with pulsed field gradients along the two lateral directions. Different pipe geometries are used to demonstrate that the sequence performs well even in the extremely inhomogeneous B0 and B1 fields of these sensors.  相似文献   

4.
A new, portable NMR magnet with a tailored magnetic field profile and a complementary radio frequency sensor have been designed and constructed for the purpose of probing in situ the sub-surface porosity of cement based materials in the built environment. The magnet is a one sided device akin to a large NMR-MOUSE with the additional design specification of planes of constant field strength /B0/ parallel to the surface. There is a strong gradient G in the field strength perpendicular to these planes. As with earlier GARField magnets, the ratio G//:B0/ is a system constant although the method of achieving this condition is substantially different. The new magnet as constructed is able to detect signals 50mm (1H NMR at 3.2 MHz) away from the surface of the magnet and can profile the surface layers of large samples to a depth of 35-40 mm by moving the magnet, and hence the resonant plane of the polarising field, relative to the sample surface. The matching radio frequency excitation/detector coil has been designed to complement the static magnetic field such that the polarising B0 and sensing B1 fields are, in principal, everywhere orthogonal. Preliminary spatially resolved measurements are presented of cement based materials, including two-dimensional T1-T2 relaxation correlation spectra.  相似文献   

5.
A new analytical approach is used in the design of disc-like gradient coils suitable for magnet geometries with main field direction perpendicular to the surface of the disc. An inverse procedure is used to optimize the coil's characteristics, subject to the restrictions imposed by the desired field behavior over a certain set of constraint points inside a predetermined imaging volume. Excellent agreement between the expected values of the gradient magnetic field and the numerical values generated by applying the Biot-Savart law to a discrete current pattern of the perspective disc coil was found. A Finite Element Analysis package was used to predict the fringe gradient field levels for a non-shielded axial disc coil and for a self-shielded transverse disc coil in the vicinity of the magnet poles. The numerical results indicate that for the self-shielded design the gradient fringe field is 1000 times smaller than the corresponding fringe field for the non-shielded disc case. Also no significant spatial dependence was noticed for the shielded coil's fringe field.  相似文献   

6.
In U-shaped, hand-size magnetic resonance surface scanners, imaging is performed along only one spatial direction, with the application of just one gradient (one-dimensional imaging). Lateral spatial resolution can be obtained by magnet displacement, but, in this case, resolution is very poor (on the order of some millimeters) and cannot be useful for high-resolution imaging applications. In this article, an innovative technique for acquisition and reconstruction of images produced by U-shaped, hand-size MRI surface scanners is presented. The proposed method is based on the acquisition of overlapping strips and an analytical reconstruction technique; it is capable of arbitrarily improving spatial lateral resolution without either using a second magnetic field gradient or making any assumptions about the imaged sample extension. Numerical simulations on synthetic images are reported demonstrating the method functionalities. The presented method also makes it possible to use U-shaped, hand-size MRI surface scanners for high-resolution biomedical applications, such as the imaging of skin lesions.  相似文献   

7.
The design and construction of a unilateral NMR (UMR) magnet assembly for near-surface 1D profiling is presented. The arrangement consists of a single permanent magnet topped with a shaped iron pole cap. The analytically determined profile of the pole cap shapes the field over the magnet, giving a constant gradient of 31 G/cm over a 8mm depth at a 1H frequency of 4.26 MHz in a spot approximately 5 mm wide. The moderate gradient allows 1D profiling of planar samples with a frequency encoded spin-echo experiment. The curvature of the magnetic field limits the available resolution to 100's of microm. The device is suitable for profiling planar samples in which a coarse resolution but large spatial extent is desired.  相似文献   

8.
叙述了一个L波段(1.05 GHz)用于ESR和ESR成像的装置,用这套自制装置实现了3D ESR成像. 该装置由L波段ESR谱仪、三组梯度场线圈及控制单元和PC机数据采集系统组成. 样品腔是一个3-环2-缝再进入式谐振腔,可放入直径为20 mm、 长30 mm的H2O样品,空谐振腔的频率是1.05 GHz. 微波振荡频率用自动频率控制(AFC)的方法自动锁在有载腔的频率上. 梯度场线圈沿X-,Y-和Z-轴产生线性梯度场,在中心40 mm球形范围内梯度场强度为2 mT/cm. 依照Lauterbur's方法进行3D ESR 图像重建. 用该系统检测了样品中TEMPO氮氧自由基的3D空间分布. 得到了TEMPO的2D、3D ESR图像、用像素灰度表示的自旋密度分布图及3D ESR-CT图像.  相似文献   

9.
We introduce a simple, efficient, low-SAR method for magnetic resonance imaging in the presence of a static field with a permanent, and possibly large gradient. The technique, which is called slant-slice imaging is essentially a spin-echo imaging sequence except that the imaging slice is oriented such that the static field gradient can be used in conjunction with applied gradients during readout. Data are collected for 2D slices. Unlike single point imaging techniques, entire lines of k-space are acquired with each readout. The slant-slice pulse sequence is used to obtain high quality images, using a clinical scanner to simulate a static field with a large permanent gradient. The effects of the inhomogeneity are quantified by two parameters nu and q, which are useful for assessing the utility of a magnet design for 3D-MR imaging.  相似文献   

10.
A new pulsed field gradient multi-echo imaging technique to encode position in the phase of every echo generated by a CPMG sequence in the presence of a strongly inhomogeneous static magnetic field is presented. It was applied to improve the sensitivity in an imaging experiment by adding the echo train acquired during the CPMG sequence and to spatially resolve relaxation times of inhomogeneous specimens using single-sided probes. The sequence was implemented in a new bar-magnet MOUSE equipped with a gradient coil system to apply a pulsed magnetic field with a constant gradient along one spatial coordinate. An important reduction by a factor larger than two orders of magnitude in the acquisition time was obtained compared to the previously published single-point imaging technique.  相似文献   

11.
分别研究了磁场线圈电流为115.2和137.7A以及137.7A并在加热台下加放SmCo永磁体的方法,来改变单磁场线圈分散场MWECR CVD系统等离子体室及沉积室磁场形貌.用洛伦兹拟合定量地得到了三种磁场形貌的磁场梯度.研究了磁场梯度对沉积a-Si:H薄膜性能的影响.研究表明:在衬底附近,高的磁场梯度可以获得高的沉积速率;在温度不很高时,高的磁场梯度可得到光敏性较好的a-Si:H薄膜. 关键词: 梯度磁场 洛伦兹拟合 a-Si:H薄膜 MWECR CVD系统  相似文献   

12.
报道了自行研制的L波段三维电子自旋共振成像(3D-ESRI)系统的整机结构及各部分性能指标. 该系统主要由L波段ESR谱仪、三维梯度磁场装置、数据处理及图像重建软件组成. 系统的微波频率为1.05 GHz;最大微波功率500 mW. 采用3-环2-缝再进入式谐振腔,无载Q值>1 000;最大测量体积为φ 20 mm, 高30 mm柱状水溶液样品. 接收系统采用100 kHz锁相放大电路,最大增益可达1×106;时间常数0.02 ms~1 s;磁场调制幅度>0.5 mT. 最大梯度磁场2 mT/cm;三维梯度线性度均优于5 %;稳定度可达10-5;主磁场可在1.6~96 mT范围内任意点选择扫场起始点;在0.2~16 mT范围选择磁场扫描宽度. 数据系统为12位A/D实现数据采集,三路8位D/A控制梯度磁场. 采用滤波反投影法实现图像重建, 成像功能包括:二维、三维自旋浓度成像;等浓度线2D图像显示;3D立体和断层图像显示等. 对水溶液和固体模型样品进行ESR成像的结果表明:本系统可以开展较大体积生物样品的ESRI研究.  相似文献   

13.
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries.  相似文献   

14.
高能质子照相系统由四极磁透镜和准直器组成,实际透镜的边缘场将影响成像系统的性能.本文将含边缘场的磁场梯度用贝尔函数近似,提出了一种含边缘场的成像系统优化方法.通过Geant 4程序模拟了能量为1.6 GeV的质子成像系统,并通过优化方法给出了考虑边缘场的优化后的系统参数.研究了考虑边缘场时的成像系统参数对准直器孔径的影响.通过对比理想成像系统和优化前后的成像系统在使用准直器时的客体通量分布,研究了边缘场对质子通过客体的通量影响.结果表明,优化后的成像系统可以减小质子通过客体后的通量误差,并且积分差值在10^–2量级时,准直器的孔径参数变化亦在10^–2量级.  相似文献   

15.
王龙庆  王为民 《中国物理 B》2014,23(2):28703-028703
Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils.  相似文献   

16.
A light-weight portable electron spin resonance (ESR) spectrometer with the permanent magnet of Nd-B-Fe (Neomax) and field sweep coils was used as a demonstration tool of ESR microscopy for student’s experiments. Educational experiments on one-and two-dimensional ESR imaging are made by inserting field gradient coils or field scanning wire arrays into the cavity using test samples of DPPH. A preliminary work on double frequency modulation is described for two-dimensional imaging using microwire arrays.  相似文献   

17.
A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from −5 °C to 45 °C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties.  相似文献   

18.
研究并实现了L波段电子自旋共振三维成像(3D-EPRI)专用的三维梯度磁场系统,主磁场及扫描磁场系统以及相应的驱动控制系统. 梯度场线圈采用在铜板上用电切割方法加工的 平板式线圈,避免了用铜导线绕制线圈体积较大的缺点,从而缩小了主磁场的体积和极间距 . 梯度场强度在三维方向上均达到200 mT/m,驱动电流为20 A. 三维空 间线性度均优于5%;线性区域大于直径42 mm的球形空间. 两磁极间距离为63 mm,可以容纳通常体积的L波段谐振腔. 主磁场和扫描场线圈固定在同一轭铁架上. 它们可分别产生1.6~ 96 mT和0.2~16 mT的线性变化磁场. 5组磁场线圈(包括主磁场, 扫描磁场和三维梯度磁场)分别由5台独立的恒流驱动电源控制驱动. 电源通过数据接口由计算机控制. 初步成像实 验证明本工作所建立的磁场和梯度磁场系统可以用于EPRI实验.  相似文献   

19.
A special focused magnet, designed for the use in the magnetic targeted drug delivery system, was constructed. The theoretical calculation of the adhesion condition for a magnetic fluid drop in magnetic field with obtained design showed that the constructed focused magnet generates a sufficient magnetic force for the capture of a magnetic drop on the vessel wall and can be used 1.5–2 cm deeper in an organism compared with the prism permanent magnet, which can enable non-invasivity of the magnetic drug targeting procedure. The maximal values for magnetic field and gradient of magnetic field are 0.38 T and 101 T/m, respectively.  相似文献   

20.
A simple and fast method of measuring self-diffusion coefficients of protonated systems with a mobile single-sided NMR sensor is discussed. The NMR sensor uses a magnet geometry that generates a highly flat sensitive volume where a strong and highly uniform static magnetic field gradient is defined. Self-diffusion coefficients were measured by Hahn- and stimulated echoes detected in the presence of the uniform magnetic field gradient of the static field. To improve the sensitivity of these experiments, a Carr-Purcell-Meiboom-Gill pulse sequence was applied after the main diffusion-encoding period. By adding the echo train the experimental time was strongly shortened, allowing the measurement of complete diffusion curves in less than 1min. This method has been tested by measuring the self-diffusion coefficients D of various organic solvents and poly(dimethylsiloxane) samples with different molar masses. Diffusion coefficients were also measured for n-hexane absorbed at saturation in natural rubber with different cross-link densities. The results show a dependence on the concentration that is in good agreement with the theoretical prediction. Moreover, the stimulated-echo sequence was successfully used to measure the diffusion coefficient as a function of the evolution time in systems with restricted diffusion. This type of experiment proves the pore geometry and gives access to the surface-to-volume ratio. It was applied to measure the diffusion of water in sandstones and sheep Achilles tendon. Thanks to the strong static gradient G(0), all diffusion coefficients could be measured without having to account for relaxation during the pulse sequence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号