首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A highly sensitive and stable amperometric tyrosinase biosensor has been developed based on multiwalled carbon nanotube (MWCNT) dispersed in mesoporous composite films of sol–gel‐derived titania and perfluorosulfonated ionomer (Nafion). Tyrosinase was immobilized within a thin film of MWCNT–titania–Nafion composite film coated on a glassy carbon electrode. Phenolic compounds were determined by the direct reduction of biocatalytically‐liberated quinone species at ?100 mV versus Ag/AgCl (3 M NaCl) without a mediator. The present tyrosinase biosensor showed good analytical performances in terms of response time, sensitivity, and stability compared to those obtained with other biosensors based on different sol–gel matrices. Due to the large pore size of the MWCNT–titania–Nafion composite, the present biosensor showed remarkably fast response time with less than 3 s. The present biosensor responds linearly to phenol from 1.0×10?7 M to 5.0×10?5 M with an excellent sensitivity of 417 mA/M and a detection limit of 9.5×10?8 M (S/N=3). The enzyme electrode retained 89% of its initial activity after 2 weeks of storage in 50 mM phosphate buffer at pH 7.0.  相似文献   

2.
Composite solution of sol–gel‐derived titania and perfluorosulfonated ionomer (Nafion) was used as a solubilizing agent for multiwalled carbon nanotubes (CNT) as well as an encapsulation matrix for alcohol dehydrogenase (ADH) for the fabrication of a highly sensitive and stable amperometric ethanol biosensor. ADH was immobilized within a thin film of CNT–titania–Nafion composite film coated on a glassy carbon electrode. Because of the mesoporous nature of the CNT–titania–Nafion composite film, the present biosensor exhibited remarkably fast response time within 2 s. The presence of CNT in the composite film increases not only the sensitivity of the ethanol biosensor but also the long‐term stability of the biosensor. The present biosensor responds linearly to ethanol in the wide concentration ranges from 1.0×10?5 M to 3.0×10?3 M with the sensitivity of 51.6 mA M?1cm?2. The present biosensor showed good long‐term stability with 75% of its activity retained after 4 weeks of storage in 50 mM phosphate buffer at pH 7.0.  相似文献   

3.
A highly sensitive electrochemical biosensor for the detection of trace amounts of 8‐azaguanine has been designed. Double stranded (ds)DNA molecules are immobilized onto a glassy carbon electrode surface with Langmuir–Blodgett technique. The adsorptive voltammetric behaviors of 8‐azaguanine at DNA‐modified electrode were explored by means of cyclic voltammetry and square wave voltammetry. Compared with bare glassy carbon electrode (GCE), the Langmuir–Blodgett film modified electrode can greatly improve the measuring sensitivity of 8‐azaguanine. Under the optimum experimental conditions, the Langmuir–Blodgett film modified electrode in pH 3.0 Britton–Robinson buffer solutions shows a linear voltammetric response in the range of 5.0×10?8 to 1.0×10?5 mol L?1 with detection limit 9.0×10?9 mol L?1. The method proposed was applied successfully for the determination of 8‐azaguanine in diluted human urine with wonderful satisfactory.  相似文献   

4.
Mesoporous titania‐Nafion composite doped with carbon nanotube (CNT) has been used for the immobilization of tris(2,2′‐bipyridyl)ruthenium(II) (Ru(bpy)32+) and alcohol dehydrogenase on an electrode surface to yield a highly sensitive and stable electrogenerated chemiluminescence (ECL) ethanol biosensor. The presence of CNT in the composite film increases not only the sensitivity of the ECL biosensor but also the long‐term stability of the biosensor. The present biosensor responds linearly to ethanol in the wide concentration ranges from 1.0×10?5 M to 1.0×10?1 M with a detection limit of 5.0×10?6 M (S/N=3). The present ECL ethanol biosensor exhibited higher ECL response compared to that obtained with the ECL biosensor based on the corresponding composite without CNT. The present CNT‐based ECL biosensor showed good long‐term stability with 75% of its initial activity retained after 2 weeks of storage in 50 mM phosphate buffer at pH 7.0.  相似文献   

5.
A new H2O2 enzymeless sensor has been fabricated by incorporation of thionin onto multiwall carbon nanotubes (MWCNTs) modified glassy carbon electrode. First 50 μL of acetone solution containing dispersed MWCNTs was pipetted onto the surface of GC electrode, then, after solvent evaporations, the MWCNTs modified GC electrode was immersed into an aqueous solution of thionin (electroless deposition) for a short period of time <5–50 s. The adsorbed thin film of thionin was found to facilitate the reduction of hydrogen peroxide in the absence of peroxidase enzyme. Also the modified electrode shows excellent catalytic activity for oxygen reduction at reduced overpotential. The rotating modified electrode shows excellent analytical performance for amperometric determination of hydrogen peroxide, at reduced overpotentials. Typical calibration at ?0.3 V vs. reference electrode, Ag/AgCl/3 M KCl, shows a detection limit of 0.38 μM, a sensitivity of 11.5 nA/μM and a liner range from 20 μM to 3.0 mM of hydrogen peroxide. The glucose biosensor was fabricated by covering a thin film of sol–gel composite containing glucose oxides on the surface of thionin/MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 1 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. In addition biosensor can reach 90% of steady currents in about 3.0 s and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) is eliminated. The usefulness of biosensor for direct glucose quantification in human blood serum matrix is also discussed. This sensor can be used as an amperometric detector for monitoring oxidase based biosensors.  相似文献   

6.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

7.
《Electroanalysis》2005,17(1):89-96
Iron‐phthalocyanines (FePc) are functionalized at multi‐walled carbon nanotubes (MWNTs) to remarkably improve the sensitivity toward hydrogen peroxide. We constructed a highly sensitive and selective glucose sensor on FePc‐MWNTs electrode based on the immobilization of glucose oxidase (GOD) on poly‐o‐aminophenol (POAP)‐electropolymerized electrode surface. SEM images indicate that GOD enzymes trapped in POAP film tend to deposit primarily on the curved tips and evenly disperse along the sidewalls. The resulting GOD@POAP/FePc‐MWNTs biosensor exhibits excellent performance for glucose with a rapid response (less than 8 s), a wide linear range (up to 4.0×10?3 M), low detection limits (2.0×10?7 M with a signal‐to‐noise of 3), a highly reproducible response (RSD of 2.6%), and long‐term stability (120 days). Such characteristics may be attributed to the catalytic activity of FePc and carbon nanotube, permselectivity of POAP film, as well as the large surface area of carbon nanotube materials.  相似文献   

8.
A sensitive amperometric glucose biosensor based on platinum nanoparticles (PtNPs) combined aligned carbon nanotubes (ACNTs) electrode was investigated. PtNPs which can enhance the electrocatalytic activity of the electrode for electrooxidating hydrogen peroxide by enzymatic reaction were electrocrystallized on 4‐aminobenzene monolayer‐grafted ACNTs electrode by potential‐step method. These PtNPs combined ACNTs' (PtNPs/ACNTs) surfaces were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The highly dispersed PtNPs on ACNTs can be obtained. The enzyme electrode exhibits excellent response performance to glucose with linear range from 1×10?5–7×10?3 mol L?1 and fast response time within 5 s. Furthermore, this glucose biosensor also has good reproducibility. It is demonstrated that the PtNPs/ACNTs electrode with high electrocatalytic activity is a suitable basic electrode for preparing enzyme electrodes.  相似文献   

9.
《Analytical letters》2012,45(12):2373-2389
ABSTRACT

The performance of a first generation glucose amperometric biosensor based on the entrapment of glucose oxidase (GOx) within a net of copper electrodeposited onto activated glassy carbon electrode, is described. The copper electrodeposited offers an efficient electrocatalytic activity towards the reduction of enzymatically-liberated hydrogen peroxide, allowing for a fast and sensitive glucose quantification. The influence of the electrodeposition conditions (pH, potential, time, copper salt and enzyme concentrations) on the response of the bioelectrode was evaluated from the amperometric signals of hydrogen peroxide and glucose. The combination of copper electrodeposition with a nation membrane allows an excellent selectivity towards easily oxidizable compounds such as uric and ascorbic acids at an operating potential of -0.050 V. The response is linear up to 2.0 × 10?2 M glucose, the detection limit being 1.2 × 10?3 M.  相似文献   

10.
A simple method was developed to prepare a cobalt(II) Schiff base (Co(salen))/large mesoporous carbon (LMC) composite film. The structure and electrocatalytic performance of the Co(salen)/LMC film were investigated by scanning electron microscopy (SEM) and cyclic voltammetry (CV). The Co(salen)/LMC film exhibits high electrocatalytic activity toward H2O2, such as low detection limit (8.5×10?7 M) and wide linear concentration range (2.0×10?6–8.9×10?3 M). Furthermore, glucose oxidase (GOD) was self‐assembled on the surface of the Co(salen)/LMC film modified electrode. Determination of glucose in human blood serum with satisfying result was investigated by the resulting biosensor.  相似文献   

11.
Glucose oxidase(GOD) was encapsulated in the Graphene/Nafion film modified glassy carbon electrode(GCE) and used as an ECL sensor for glucose. The GOD retains its bioactivity after being immobilized into the composite film. The sensor gives a linear response for glucose in the range of 2.0×10?6–1.0×10?4 mol/L with a detection limit of 1.0×10?6 mol/L. The sensor showed good stability, the RSD for continuous scanning for 5.0×10?5 mol/L glucose was 4.21 % (n=5). After being stored in 0.05 mol/L pH 7.4 PBS in 4 °C for two weeks, the modified electrode maintains 80 % of its initial activity. The glucose sensor provides new opportunity for clinical diagnosis applications.  相似文献   

12.
A highly sensitive amperometric galactose biosensor was developed by encapsulating galactose oxidase within the graphene-doped sol-gel titania-Nafion composite film on platinized glassy carbon electrode. Due to the combined electrocatalytic activity of graphene and Pt NPs on the electrode towards hydrogen peroxide as well as the mesoporous nature of the titania-Nafion composite, the present galactose biosensor exhibited relatively fast response time under 2 s, high sensitivity of 40.6 mAM−1cm−2, and wide dynamic range over three orders of magnitude with a detection limit of 3.78×10−6 M (S/N=3). In addition, the biocompatible composite in the biosensor secures excellent long-term stability.  相似文献   

13.
A cationic quinine‐imide dye brilliant cresyl blue (BCB) and horseradish peroxidase (HRP) were co‐immobilized within ormosil on multiwalled carbon nanotubes modified glassy carbon electrode for the fabrication of highly sensitive and selective hydrogen peroxide biosensor. The presence of epoxy group in ormosil as organic moiety improves the mechanical strength and transparency of the film and amino group provides biocompatible microenvironment for the immobilization of enzyme. The presence of MWCNTs improved the conductivity of the nanocomposite film. The surface characterization of MWCNT modified ormosil nanocomposite film was performed with scanning electron microscopy (SEM) and atomic force microscopy (AFM). Cyclic voltammetry and amperometry measurements were used to study and optimize the performance of the resulting peroxide biosensor. The apparent Michaelis–Menten constant was determined to be 1.5 mM. The proposed H2O2 biosensor exhibited wide linear range from 3×10?7 to 1×10?4 M, and low detection limit 1×10?7 M (S/N=3) with fast response time <5 s. The probable interferences in bio‐matrix were selected to test the selectivity and no significant response was observed in the biosensor. This biosensor possessed good analytical performance and long term storage stability.  相似文献   

14.
This work reports on the performance of new glucose biosensors based on the combination of the electrocatalytic properties of metals and carbon nanotubes towards the reduction of hydrogen peroxide with the biocatalytic activity of glucose oxidase (GOx). The bioelectrodes were obtained by dispersing the metal particles, enzyme and multi-wall carbon nanotubes within a mineral oil binder. The strong electrocatalytic activity of copper and iridium towards the reduction of hydrogen peroxide has made possible an important improvement in the sensitivity for the determination of glucose compared to the carbon nanotube composite without metals. A highly sensitive and selective amperometric detection of glucose becomes possible at very low potentials (−0.100 V). The presence of the protein enables a better dispersion of the metals within the composite matrix, thus allowing an additional enhancement in the response to hydrogen peroxide. The influence of the amount of copper in the composite on the analytical performance of the bioelectrode is discussed. A biosensor containing 0.77% w/w Cu and 10.0% w/w GOx gave a fast response (10.0 s), a linear relationship between current and glucose concentration up to 1.20 × 10−2 M, and a detection limit of 2.0 × 10−5 M. A similar behavior was found for a carbon nanotube-composite electrode containing iridium.  相似文献   

15.
Chuanyin Liu  Jiming Hu 《Electroanalysis》2008,20(10):1067-1072
Hemoglobin was entrapped in composite electrodeposited chitosan‐multiwall carbon nanotubes (MCNTs) film by assembling gold nanoparticles and hemoglobin step by step. In phosphate buffer solution (pH 7), a pair of well‐defined and quasireversible redox peaks appeared with formal potential at ?0.289 V and peak separation of 100 mV. The redox peaks respected for the direct electrochemistry of hemoglobin at the surface of chitosan‐MCNTs‐gold nanoparticles modified electrode. The parameters of experiments have also been optimized. The composite electrode showed excellent electrocatalysis to peroxide hydrogen and oxygen, the peak current was linearly proportional to H2O2 concentration in the range from 1×10?6 mol/L to 4.7×10?4 mol/L with a detection limit of 5.0×10?7 mol/L, and this biosensor exhibited high stability, good reproducibility and better selectivity. The biosensor showed a Michaelis–Menten kinetic response as H2O2 concentration is larger than 5.0×10?4 mol/L, the apparent Michaelis–Menten constant for hydrogen peroxide was calculated to be 1.61 μmol/L.  相似文献   

16.
IntroductionThelevelofglucoseinbloodorurineindicateshyper andhypoglycaemia ,bothofwhichcanresultfromavarietyofendocrinedisorders .1 4 Therapidandreliabledetermi nationofglucoselevelisaroutineprojectinclinicchem istry.Urinesamplesaresaferandmoreconvenientthanbloodones .Meanwhile ,theconcentrationofglucoseinserumiscloselyassociatedwiththatinurine .2 4 Eventhoughglucoseelectrodeshavebeensuccessfullyusedinseruminclinicalapplication ,thequestionstillremainedofhowtodetecttheglucoselevelinurine ,wh…  相似文献   

17.
徐琴  刘妮娜  朱俊杰 《中国化学》2005,23(11):1510-1514
A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nation was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb^2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nation film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0× 10^-9-2.0× 10^-8 mol/L and high concentration of 2.5× 10^-8-5.0× 10^-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb^2+ ions.  相似文献   

18.
We developed a novel iron‐tetrasulfophthalocyanine‐graphene‐Nafion (FeTSPc‐GR‐Nafion) modified screen‐printed electrode to determine hydrogen peroxide (H2O2) with high sensitivity and selectivity. The nanocomposite film (FeTSPc‐GR‐Nafion) exhibits an excellent electrocatalytic activity towards oxidation of H2O2 at a potential of +0.35 V in the absence of enzyme. A comparative study reveals that the FeTSPc‐GR complexes play a dual amplification role. Amperometric experiment indicates that the sensors possess good sensitivity and selectivity, with a linear range from 2.0×10?7 M to 5.0×10?3 M and a detection limit of 8.0×10?8 M. This sensor has been successfully used to develop the glucose biosensor and has also been applied to determine H2O2 in sterile water.  相似文献   

19.
《Electroanalysis》2006,18(15):1499-1504
An amperometric method for the determination of glucose using a screen printed carbon electrode is reported. The electrode material was bulk modified with rhodium dioxide and the enzyme glucose oxidase immobilized in a Nafion‐film on the electrode surface and investigated for its ability to serve as a detector of glucose in flow injection analysis. The sensor exhibited a linear increase of the amperometric signal with the concentration of glucose in the range of 1–250 mg L?1 with a detection limit (evaluated as 3σ) of 0.2 mg L?1 under optimized flow rate of 0.4 mL min?1 in 0.1 M phosphate buffer (pH 7.5) carrier. At the potential applied (?0.2 V vs. Ag/AgCl), interferences from redox species present in the sample matrix were negligible. The biosensor reported here retained its activity for more than 40 injections or 4 months of storage at 6 °C. The RSD was determined as 1.8% for a glucose concentration of 25 mg L?1 (n=5) with a typical response time of about 28 s.  相似文献   

20.
《Electroanalysis》2005,17(7):607-612
Based on the inhibition effect of dopamine and epinephrine on Ru(bpy) ‐tripropylamine electrogenerated chemiluminescence system, the excellent properties of carbon nanotube, and the cation permselectivity of Nafion film, an electrogenerated chemiluminescence inhibition method for determination of dopamine and epinephrine in the presence of ascorbic acid at carbon nanotube/Nafion‐Ru(bpy) composite film modified glassy carbon electrode was described. The results showed that the proposed method was sensitive and selective for the determination of dopamine and epinephine. The linear calibration range was from 1.6×10?9 M to 3.2×10?5 M and 5×10?8 M to 6×10?5 M for dopamine and epinephrine, respectively. 200‐fold excess of ascorbic acid did not interfere with the determination of 1 μM dopamine and epinephrine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号