首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nafion solution as a binder,the Gr/CeO2 /Nafion/GCE modified electrode was prepared based on graphene (Gr)-nano cerium oxide (CeO2 )composite materials. The electrochemical behavior of Pb(II)on the modified electrode was investigated using differential pulse anodic stripping voltammetry (DPASV). Subsequently,a determination method for Pb(II)was established. The concentrations and ratio of composite materials,buffer solution pH,modification amount,enrichment potential and time were optimized. Under the optimal conditions ,the peak current of Gr/CeO2 /Nafion/GCE showed good linearity in the range of 0.24-48.31 μµmol/L of Pb(II),and the detection limit was 4.3 nmol/L. Interference experiments showed that the other common anions and cations in water samples caused little interference to Pb(II)detection. Furthermore,the interference of Cu(II)within 10 times is acceptable. The modified electrode was used to the detection of Pb(II) in four complex water samples,and the recovery rates of the spiked assays were from 89.5% to 107.7%. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

2.
A one-step electrochemical approach for synthesis of Pt nanoparticles/reduced graphene oxide(Pt/RGO) was demonstrated.Graphene oxide(GO) and chloroplatinic acid were reduced to RGO and Pt nanoparticles(Pt NPs) simultaneously,and Pt/RGO composite was deposited on the fluorine doped SnO 2 glass during the electrochemical reduction.The Pt/RGO composite was characterized by field emission-scanning electron microscopy,Raman spectroscopy and X-ray photoelectron spectroscopy,which confirmed the reduction of GO and chloroplatinic acid and the formation of Pt/RGO composite.In comparison with Pt NPs and RGO electrodes obtained by the same method,results of cyclic voltammetry and electrochemical impedance spectroscopy measurements showed that the composite electrode had higher catalytic activity and charge transfer rate.In addition,the composite electrode had proved to have better performance in DSSCs than the Pt NPs electrode,which showed the potential application in energy conversion.  相似文献   

3.
A simple and rapid protocol for the synthesis of polystyrene-graphene oxide nanocomposite(PS/GONC)was achieved for first time using an in situ polymerization method.PS/GONC modified glassy carbon electrode(PS/GONC/GCE) has been employed as an efficient nanosensor for the electrooxidation of histamine.The PS/GONC/GCE is used as an electrochemical nanosensors for monitoring histamine using differential pulse voltammetry techniques(detection limit 0.03 μmol/L).In addition,the prepared nanosensor was successfully applied to determine histamine in fish samples,yielding satisfactory results.The spiked recoveries were in the range of 98.2%-103.1%.  相似文献   

4.
Copper-nickel bimetallic nanoparticles decorated on carboxylated multi-walled carbon nanotubes (Cu/Ni/CMWCNTs)were prepared by using a simple one-pot solvothermal method,which was then employed to construct a highly sensitive non-enzymatic glucose sensor. The modified electrode showed high sensitivity and stability in glucose detection,which was mainly attributed to the synergistic effect of the compact copper-nickel nanocomposite and carboxylated multi-walled carbon nanotubes that possessing high specific surface area to increase the number of active sites and to improve the electrocatalytic activity of the modified electrode. The phase structure and morphology of the material were characterized by X-ray diffraction and scanning electron microscope; the electrochemical performance of the sensor was studied by cyclic voltammetry and chronoamperometry. The sensor had a sensitivity of 1949.1 μµA·L/(mmol·cm2)for glucose detection in the linear range of 1.0-8000 μµmol/L at a potential of 0.55 V,and the detection limit was 0.2 μµmol/L. The sensor was also applied to measure the concentration of glucose in serum samples. The developed nanocomposites sensor has the potential prospect to monitor blood glucose. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

5.
An electrochemical sensor for doxycycline hyclate(DC)detection with high sensitivity and good selectivity is reported.The sensor was fabricated by electro-polymerization of molecularly imprinted polymers(MIPs)in the presence of DC onto multi-walled carbon nanotubes modified glassy carbon electrode(MWCNTs/GCE).The MWCNTs can significantly increase the current response of the sensor,leading to enhanced sensitivity.The MIPs provide selective recognition sites for DC detection.The experimental parameters,such as the polymer monomer concentration,supporting electrolyte pH,the time for electro-polymerization and the incubation time of the sensor with DC were optimized.Under optimized experimental conditions,the sensor displayed a linear range of 0.05μmol/L-0.5μmol/L towards DC detection,with the detection limit of 1.3×10^-2μmol/L.The sensor was successfully applied for recovery test of DC in human serum samples.  相似文献   

6.
The toxicities of cyanide and tetramethylene disulfotetramine (tetramine) were evaluated by two methods of luminescent bacteria and PbO2 electrochemical sensor. Vibrio-qinghaiensis, a kind of luminescent bacteria, can produce bioluminescence and the bioluminescence was decreased with the addition of toxicants. The toxicities of cyanide and tetrarnine were expressed as 10 min-EC50 value, which was the concentration of chemical that reduces the light output by 50% after contact for 10 min. Nano PbO2 modified electrode, a rapid toxicity determination method was also described in this work. By the PbO2 modified electrode, the current responses of Escherichia coli (E. coli) were changed with the addition of toxicants. The value of 10 min-EC50 was also provided with the PbO2 electrochemical sensor. Compared with the 10 min-EC50 and detection limits (38.38 and 0.60 μg/mL for cyanide, 0.24 and 0.02 μg/mL for tetramine) with luminescent bacteria, the PbO2 sensor provided a simple and convenient method with lower 10 min-EC50 and detection limits (26.37 and 0.52 μg/mL for cyanide, 0.21 and 0.01 μg/mL for tetramine) and fast response time.  相似文献   

7.
卢丽敏  徐景坤 《高分子科学》2014,32(8):1019-1031
A novel graphene oxide doped poly(hydroxymethylated-3,4-ethylenedioxythiophene)(PEDOT-MeOH/GO) composite film was synthesized and utilized as an efficient electrode material for simultaneous detection of rutin and ascorbic acid(AA). PEDOT-MeOH/GO films were synthesized on glassy carbon electrode(GCE) by a facile one-step electrochemical approach and were characterized by scanning electron microscopy, UV-Vis spectroscopy, FTIR spectra and electrochemical methods. Then the PEDOT-MeOH/GO/GCE was applied successfully in the simultaneous detection of rutin and AA. The results showed that the oxidation peak currents of rutin and AA obtained at the PEDOT-MeOH/GO/GCE were much higher than those at the traditional conducting polymer PEDOT/GO/GCE, PEDOT-MeOH/GCE, PEDOT/GCE and bare GCE. Under optimized conditions, the linear ranges for rutin and AA are 20 nmol/L-10 μmol/L and 8 μmol/L-1 mmol/L, respectively. The detection limit is 6 nmol/L for rutin and 2 μmol/L for AA(S/N = 3), which are lower than those of the reported electrochemical sensors.  相似文献   

8.
Copper hydroxyphosphate@metal-organic frameworks/multi-wall carbon nanotube composites (CHP@Cu3 (BTC)2 /MWCNTs)were prepared by a new in-situ template method and then an electrochemical sensor was developed based on the composites. The crystal structure and morphology of the material were characterized by X-ray diffraction and scanning electron microscope. Cyclic voltammetry and linear sweep voltammetry were used to study the electrochemical catalytic performance,and the determination conditions were optimized. The rapid and sensitive detection of chlorphenamine maleate was realized. There was a good linear relationship between the oxidation peak current and concentration of chlorphenamine maleate in the ranges from 5 to 100 µμmol/L and from 150 to 800 µμmol/L,and the linear equations were as Ipa (µμA)=0.1559c(µμmol/L)-0.3533 (R2 =0.9973)and Ipa (µμA)=0.02328c(µμmol/L)+16.63(R2 =0.9594),and the detection limit was 1.67 µμmol/L. The recoveries of the actual drug ranged from 91.0% to 109.1%. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

9.
A carbon paste electrode that was chemically modified with multiwall carbon nanotubes and p-aminophenol was used as a selective electrochemical sensor for the simultaneous detection of hydroxylamine (HX) and phenol. Cyclic voltammetry, double potential-step chronoamperometry, square wave voltammetry (SWV), and electrochemical impedance spectroscopy were used to investigate the use of p-aminophenol in the carbon nanotubes paste matrixes as a mediator for the electrocatalytic oxidation of HX and phenol in aqueous solution. The coefficient of electron transfer and catalytic reaction rate constant were determined using the electrochemical methods. Under optimized conditions, the electrocatalytic oxidation current peaks for HX and phenol increased linearly with concentration in the range of 0.5-180.0 and 10.0-650.0 μmol/L for HX and phenol, respectively. The detection limits for HX and phenol were 0.15 and 7.1 μmol/L, respectively. The anodic potential peaks of HX and phenol were separated by 0.65 V in SWV. Because of good selectivity and sensitivity, the present method provides a simple method for the selective detection of HX and phenol in practical samples such as water samples.  相似文献   

10.
A simple and fast "non-hole" bacteria surface imprinted (SPBIP) impedance sensor was constructed for ultrasensitive detection of Salmonella. The SPBIP sensor was prepared by one step electropolymerization of pyrrole (functional monomer), single-walled carbon nanotube (SWNT, nano-modulator), and Salmonella(template) onto a glassy carbon electrode. After removing the bacterial template, "non-hole" imprinted sites were formed on the surface of the polymer matrix, allowing the target bacteria to be specifically recognized. The resulting changes in the electrode surface impedance could be used to detect the target bacteria. The effects of the amount of SWNT, polymerization cycles, eluents, elution time and recognition time on the recognition ability of the sensor were investigated. Under the optimal conditions, the sensor could be used to detect 10~1×107 CFU/mLSalmonella with the limit of detection of 3.5 CFU/mL. The sensor could be used for the detection of salmonella in drinking water and orange juice samples with the recoveries ranging from 95.4% to 109.5%. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

11.
Redox graphene-MXene(rGO-MXene) nanocomposites were prepared by ion polymerization and used to construct a highly sensitive electrochemical sensor for baicalin(BA) detection. The synergistic effect of rGO and MXene increased the specific surface area and electron transport capacity of the electrode, and significantly enhanced the electrochemical response of BA. The cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical behavior of BA on the sensor. Under the optimal conditions, the peak current exhibited a good linear relationship with BA concentration in the range of 0. 05-10 μmol / L, and the limit of detection was as low as 28 nmol / L. The method was applied to analyze traditional Chinese medicine preparations containing baicalin, such as Qingkailing Capsule and Sanhuang Tablets with good accuracy and spiked recovery. The results were highly consistent with those of high performance liquid chromatography, providing a technical means for the rapid and sensitive detection of traditional Chinese medicine preparations. © 2022, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

12.
Molecularly imprinted polymer(MIP) films for hemoglobin detection were prepared onto the Au/Cr coated surface plasmon resonance(SPR) sensor chips by the in situ electropolymerization of 3-aminophenylboronic acid(3-APBA).The formation of the films and rebinding processes of hemoglobin were monitored by in situ electrochemical-SPR(EC-SPR) spectroscopy,with allowed real-time observation of the simultaneous changes in electrochemical and optical properties of the films.Scanning electron microscopy(SEM) and atomic force microscopy(AFM)were used to characterize the surface morphologies of the MIP films.The effects of pH,ion strength,different metal ions on rebinding Hb,the specific binding and the selective recognition were investigated.The results obtained with the molecular imprinted SPR chips indicate a good adsorption of Hb in a range of 0.0005-5 mg/mL in 0.05 mol/L sodium phosphate buffer at pH=7.0.A linear calibration curve(R2=0.94) of the SPR sensor for Hb detection was obtained in a range of 0.05-5 mg/mL.The detection limit for hemoglobin by this method was 0.000435 mg/mL(S/N=3).Interference studies indicate that the MIP films have a good selectivity compared with the referenced proteins.The stability of the sensor was also established.Results indicate that the SPR sensor chip keeps 87.6% of its original response after 14 d of storage under dry and ambient conditions.  相似文献   

13.
In this work, we have reported the influence of the addition of base (KOH) on the physicochemical property of ceria synthesized by alcohothermal process, and the alcohothermal mechanism was also put forward. Furthermore, the prepared CeO2 was used as the support to prepare CuO/CeO2 catalysts via the wet impregnation method. The samples were characterized by N2 adsorption-desorption, X-ray powder diffraction (XRD), high resolution transmission electron microscopy (HRTEM), and temperature-programmed reduction by H2 (H2-TPR). The catalytic properties of the CuO/CeO2 catalysts for low-temperature CO oxidation were studied using a microreactor-GC system. The crystal size of CeO2-A was much smaller than that of CeO2-B, and the corresponding copper oxide catalysts exhibited higher catalytic activity than that of the CeO2-B-supported catalysts under the same reaction conditions. The alcohothermal mechanism indicated that KOH plays a key role in determining the physicochemical and catalytic properties of ceria-based materials.  相似文献   

14.
Gold nanoparticles (AuNPs)/chitosan (CS)/reduced graphene oxide (RGO) modified electrode was prepared. The electrochemical behaviors of bergenin on this modified electrode was investigated by cyclic voltammetry. The results showed that the proposed electrode exhibited an obvious electrocatalytic ability to the oxidation of bergenin. The differential pulse voltammetry was employed to detect bergenin in 0.1 mol/L phosphate buffer solution (pH 6.0). A good linear relationship between the oxidation peak current and the concentration of bergenin was found in the range of 2.0×10-7-1.2×10-6 mol/L with the detection limit of 6.0×10-8 mol/L (S/N=3).The prepared electrode had good anti-interference ability and potential application in the actual detection of bergenin. © 2023, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

15.
A nonenzymatic electrochemical sensor for glucose and fructose was fabricated that contained a glassy carbon electrode modified with a copper oxide (CuO)/multiwalled carbon nanotube (MWCNT) nanocomposite. The electrochemical properties of the CuO/MWCNT‐modified glassy carbon electrode were investigated. Two distinguishable anodic peaks were observed around 0.30 and 0.44 V corresponding to the oxidation of glucose and fructose, respectively, at the surface of the modified electrode. The detection limits for glucose and fructose were both 0.04 mmol/L. The sensor was used to simultaneously determine the concentrations of glucose and fructose in hydrolyzed sucrose samples, and to measure glucose in blood serum samples, demonstrating its potential as a nonenzymatic carbohydrate sensor.  相似文献   

16.
In this study,nano-polyanline and manganese oxide nanometer tubular composites(nano-PANI@MnO2)were prepared by a surface initiated polymerization method and used as electrochemical capacitor electrode materials; and the effect of aniline amount on the microstructure and electrochemical performance was investigated. The microstructures and surface morphologies of nano-PANI@MnO2 were characterized by X-ray diffraction,scanning electron microscopy and fourier transformation infrared spectroscope. The electrochemical performance of these composite materials was performed with cyclic voltammetry,charge–discharge test and electrochemical impedance spectroscopy,respectively. The results demonstrate that the feed ratio of aniline to MnO2 played a very important role in constructing the hierarchically nano-structure,which would,hence,determine the electrochemical performance of the materials. Using the templateassisted strategy and controlling the feed ratio of aniline to MnO2,the nanometer tubular structure of nanoPANI@MnO2 was obtained. A maximum specific capacitance of 386 F/g was achieved in aqueous 1 mol/L Na NO3 electrolyte with the potential range from 0 to 0.6 V(vs. SCE).  相似文献   

17.
The recognition interaction of rhodamine B (RB) with DNA was studied in pH 7.5 Britton-Robinson (B-R) buffer solution by electrochemical techniques. An irreversible oxidation peak at glassy carbon electrode was obtained at 0.92V (vs. SCE). After the addition of DNA into the RB solution, the peak current of RB decreased apparently without the shift of peak potential. The electrochemical parameters such as the charge transfer coefficient α and the electrode reaction standard rate constant ks of RB in the absence and presence of DNA were determined, which did not change, indicating that a non-electroactive complex was formed, so the concentration of RB in the solution decreased and the peak current decreased correspondingly.  相似文献   

18.
The methods for preparing the H2O2 generating air (oxygen) electrode and the composite electrode of photocatalyst-TiO2/C loading on the surface of the air (oxygen) electrode were introduced.In the case of the composite electrode,the current efficiency of electro-generated H2O2 is higher than 80%(J≤15mA/cm^2).The degradation of aniline was used as an example to measure the influence of the composite electrode and compared with the system in which the air (oxygen) electrode and the photocatalyst-TiO2 were sqparated.The results confirmed that the composite electrode played an active role on accelerating the degradation rate of aniline.According to the measurement of the polarization curves of composite electrode and TiO2 photo anode,and of the adsorbing amount of aniline on the surface of the composite electrode,the principle of descending the recombination reta of photo-generated electron and hole and of enhancing the oxidation rate of organic molecule was described.The mechanism about the degradation of aniline was also discussed.  相似文献   

19.
Li  Kun  Su  Min  Yang  Qian  Li  Yueqi  Yu  Hao 《分析试验室》2022,(7):808-814
A nickel-iron hydroxide/multi-walled carbon nanotubes MWCNTscomposite film electrode was prepared by electrochemical derivation of metal hexacyanoferrate in alkaline solution. MWCNTs film modified electrode was prepared by dropping methodthen Ni-Fe bimetal hexacyanoferrateNi-FeHCFnanoparticles were deposited on the surface of MWCNTs by cyclic voltammetry. This Ni-FeHCF/MWCNTs electrode was electrochemically derived in alkaline solution and a MWCNTs composite film electrodeNiOH2-FeOH3 /MWCNTs/ CCEwas obtained. The surface morphology and the electrochemical behavior of this modified electrode were characterized by scanning electron microscopeSEMand cyclic voltammetryCV. This electrode exhibited high catalytic activity for the electrochemical oxidation of urea under the synergistic action of each component. Based on thisthe non-enzymatic electrochemical sensing of urea was established. In 1.0 mol/L KOH solution the linear range of urea by amperometry was between 5.0×10−3 and 2.8 mmol/Land the detection limit was 3.6 μµmol/L. The sensitivity to urea was 54.3 μµA/mmol/L. This electrode could be used for the determination of urea in river water and human urine samples. © 2022, Youke Publishing Co.,Ltd. All rights reserved.  相似文献   

20.
尉艳  李茂国方宾 《中国化学》2007,25(11):1622-1626
The preparation of a glassy carbon electrode modified by CeO2 nanoparticles was described, which was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. In pH 6.0 buffer, the CeO2 nanoparticle modified electrode (CeO2 NP/GC) gave an excellent electrocatalytic activity for the oxidation of uric acid (UA). The catalytic current of UA versus its concentration had a good linear relation in the range of 2.0 × 10^-7-5.0 × 10^- 4 mol/L, with the correlation coefficient of 0.9986 and detection limit of 1.0 ×10^-7 mol/L. The modified electrode can be used for the determination of UA in urine, which can tolerate the interference of ascorbic acid up to 1000-fold. The method was simple, quick and sensitive.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号