首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
刘忠  杨文博  金永杰  白钢 《色谱》2004,22(3):231-233
以5,5′-二硫硝基苯甲酸(DTNB)为柱前衍生试剂对酶促反应液进行衍生化,用C18色谱柱在室温下采用二元梯度洗脱,于330 nm波长下检测,同时以2-巯基乙醇和二硫苏糖醇(DTT)为对照,对L-半胱氨酸的分离峰进行确认,并对酶促反应液中的L-半胱氨酸进行分离测定。L-半胱氨酸浓度为5~950 μmol/L时,其浓度与峰面积呈显著的线性关系。高、中、低浓度水平的L-半胱氨酸加标回收率为99.7%~100.5%,相对标准偏差小于1.3%,检测限为0.8 μmol/L。方法简便、快速、可靠。用于样品分析,结果  相似文献   

2.
固相萃取-高效液相色谱法测定人血浆中的川芎嗪   总被引:7,自引:0,他引:7  
建立了高效液相色谱测定人血浆中川芎嗪浓度的方法。色谱条件:分析柱为Luna C18(150 mm×4.6 mm i.d.,5 μ m),流动相为甲醇-乙腈-醋酸盐缓冲液(pH 5.0)(体积比为50∶8∶42),流速1.0 mL/min,柱温40 ℃,检测波长280 nm。 血浆样品预处理采用C8固相小柱萃取法。方法的线性范围为25~5000 μg/L,线性相关系数为0.9999。高、中、低浓度 的川芎嗪在标准血浆样品中的平均提取回收率为96.72%~100.90%,日内和日间相对标准偏差(RSD)小于8.64%,准确度 为99.59%~103.26%,检测限为10 μg/L。该方法的各项效能指标符合生物样品的分析要求,可用于川芎嗪制剂的人体药 代动力学研究。  相似文献   

3.
Orejuela E  Silva M 《The Analyst》2002,127(11):1433-1439
A rapid, reliable method for the routine determination of phenol and 4-methylphenol in urine samples by liquid chromatography with peroxyoxalate chemiluminescence detection was developed. Phenols were first cleaned up by passing the sample through a LiChrolut EN sorbent column and then derivatized straightforwardly with dansyl chloride (15 min at room temperature) thanks to the micellar catalytic effect provided by Triton X-100 micelles. The derivatives were successfully separated in 15 min on a C18 analytical column and determined using an integrated derivatization chemiluminescence detection unit based on the bis(2,4,6-trichlorophenyl) oxalate-hydrogen peroxide system. Linear ranges from 3 to 500 microg L(-1), limits of detection at a signal-to-noise ratio of 3 from 0.3 to 0.5 microg L(-1) and relative standard deviations from 2.8 to 4.7% were obtained. The proposed method was applied to the assay of different human urine samples (healthy, smoker and petrol station worker volunteers) and free and total phenol and 4-methylphenol were determined. The proposed method surpasses other chromatographic alternatives for the determination of these phenols in terms of limit of detection and sample requirements for the analysis.  相似文献   

4.
抑制型电导检测离子色谱法测定饮用水中的痕量溴酸盐   总被引:4,自引:1,他引:3  
应波  李淑敏  岳银玲  鄂学礼 《色谱》2006,24(3):302-304
建立一种直接进样测定饮用水中痕量溴酸盐的电导检测离子色谱法。选用Metrosep A Supp 5阴离子交换分离柱,碳酸盐淋洗液。抑制型电导检测采用化学抑制器和CO2抑制器顺序双抑制系统。实验结果显示,溴酸根阴离子与常见共存阴离子完全分离,溴酸盐含量在5~100 μg/L范围内具有良好的线性(r=0.9999),精密度高(相对标准偏差(RSD)<4%),方法的检出限为0.50 μg/L,样品加标平均回收率为96.1%~107%。该方法操作简单,分离效果好,可与常见阴离子实现同时分析,灵敏度高,重现性好,可作为饮用水中溴酸盐的标准测定方法。  相似文献   

5.
An innovative reversed-phase high-performance liquid chromatographic method is validated for the simultaneous determination of rofecoxib and celecoxib in human plasma. The internal standard is 4-n-pentyl-phenyl-acetic acid. Good chromatographic separation is achieved using a Zorbax SB-CN (5 microm) analytical column operated at room temperature and mobile phase consisting of acetonitrile and water containing 0.1M potassium dihydrogen orthophosphate buffer adjusted to pH 2.4 with 85% orthophosphoric acid (42:58, v/v). UV detection is performed at 254 nm, and the flow rate is maintained at 1.0 mL/min. Plasma samples are extracted into an organic solvent (1-chlorobutane) and evaporated under an air flow. The calibration curve for rofecoxib is linear over the range of 10 to 500 microg/L, and the celecoxib calibration curve is linear over the range of 20 to 2000 microg/L. The lower limit of quantitation for rofecoxib and celecoxib is 10 and 20 microg/L, respectively, using 1.0 mL of human plasma. The validation data show that the assay is sensitive, accurate, specific, and reproducible for the determination of rofecoxib and celecoxib. This method is therefore appropriate for pharmacokinetic studies to quantitate these therapeutic agents in patients with arthritis conditions.  相似文献   

6.
高效液相色谱-荧光检测法测定牛奶中氯霉素的残留量   总被引:12,自引:0,他引:12  
潘莹宇  许茜  康学军  张建新 《色谱》2005,23(6):577-580
建立了对牛奶中氯霉素的残留量进行检测的高效液相色谱-荧光检测方法。氯霉素还原后在温和条件下与荧光胺发生衍生化反应,采用十八烷基键合硅胶固定相,以乙腈/四氢呋喃/0.02 mol/L醋酸钠-醋酸缓冲液(pH 6.0)(体积比为16∶8∶76)为流动相,流速1.0 mL/min,柱温40 ℃,荧光检测激发波长为410 nm,发射波长为508 nm。在上述实验条件下,氯霉素检测的线性范围为0.4~800 μg/L (r2=0.9999),检出限为0.2 μg/L。当空白样品中氯霉素添加水平为2~40 μg/L时,该方法的回收率为66.6%~92.8%,相对标准偏差为4.5%~9.4%。该方法适用于牛奶中氯霉素痕量残留的监测,具有干扰小、选择性好、灵敏度高等优点。  相似文献   

7.
A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase Supelcosil LC-18 (250 x 4.6 mm, 5 microm) column. The mobile phase consisted of acetonitrile:water (40:60 v/v) at a fl ow rate of 0.8 mL/min. The UV-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 0.125 to 12.5 microg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quanti fi cation were 0.091 and 0.181 microg/mL, respectively.  相似文献   

8.
Hydroethanolic extracts of C. langsdorffii leaves have therapeutic potential. This work reports a validated chromatographic method for the quantification of polar compounds in the hydroethanolic extract of C. langsdorffii leaves. A reliable HPLC method was developed using two monolithic columns linked in series (100 x 4.6 mm - C18), with nonlinear gradient elution, and UV detection set at 257 nm. A procedure for the extraction of flavonols was also developed, which involved the use of 70% aqueous ethanol and the addition of benzophenone as the internal standard. The developed method led to a good detection response as the values for linearity were between 10.3 and 1000 microg/mL, and those for recovery between 84.2 and 111.1%. The detection limit ranged from 0.02 to 1.70 microg/mL and the quantitation limit from 0.07 to 5.1 microg/mL, with a maximum RSD of 5.24%. Five compounds, rutin, quercetin-3-O-alpha-L-rhamnopyranoside, kaempferol-3-O-alpha-L-rhamnopyranoside, quercetin and kaempferol, were quantified. This method could, therefore, be used for the quality control of hydroethanolic extracts of Copaifera leaves and their cosmetic and pharmaceutical products.  相似文献   

9.
A simple and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the determination of fingolimod in human blood. The analyte and internal standard fingolimod-d4 were extracted from 300 μl of human blood using protein precipitation coupled with solid-phase extraction method. The chromatographic separation was achieved with a Kinetex biphenyl column (100 × 4.6 mm, 2.6 μm) under isocratic conditions at the flow rate of 0.8 ml/min and column temperature was maintained at 45°C. The detection of analyte and internal standard was carried out by tandem mass spectrometry, operated in positive ion and multiple reaction monitoring acquisition mode. The method was fully validated for its selectivity, precision, accuracy, linearity, stability, detection and quantification limit. The extraction recovery of fingolimod in human blood ranged from 98.39 to 99.54%. The developed method was linear over the concentration range of 5–2500 pg/ml with a detection limit of 1 pg/ml. The developed method was validated and successfully applied for pharmacokinetic study after oral administration of fingolimod capsules.  相似文献   

10.
A simple and selective HPLC assay was developed and utilized for determination of human plasma protein binding of baicalin. The method involved solid-phase extraction and reversed-phase chromatographic separation with a mobile phase of acetonitrile-0.02 mol/L phosphate buffer (pH 2.5; 25:75, v/v) and UV detection at 276 nm. The standard curve for baicalin was linear over the concentration range 0.1-20 microg/mL and the limit of detection was 0.02 microg/mL. The absolute recovery was greater than 76%. The intra-day and inter-day variations were less than 10%. Ultrafiltration technique was applied to determining the plasma protein binding of baicalin in human plasma. Results show the plasma protein binding of baicalin was in the range 86-92% over all the concentrations studied and the protein binding association constant was determined to be 1.21 x 10(5) L/mol at 4 degrees C.  相似文献   

11.
Transplant patients receiving the immunosuppressive drug cyclosporin A require regular monitoring to maintain levels within a narrow therapeutic range. A stable, accurate and reproducible high-performance liquid chromatographic method for analysis of cyclosporin A in whole blood has been developed using the Varian Advanced Automated Sample Processor. Starting with 200 microliters of blood, absolute recovery of both cyclosporin A and the internal standard was 81% with a detection limit of 12.5 ng/ml. The assay is perfectly linear over the range 0-1000 ng/ml (r2 = 1.0). At a concentration of 250 ng/ml, the coefficient of variation, both between samples and between assays, is 1.87%. Chromatographic cycle time is 10.2 min per sample. Up to eighty samples can be processed by one person in a working day, with final results within 16 h.  相似文献   

12.
A sensitive and precise high-performance liquid chromatographic procedure has been developed for the measurement of tiagabine concentrations in human plasma. Isolation of tiagabine and the internal standard was achieved using solid-phase extraction on disposable C8 columns. Separation was performed on a C18 analytical column using a mobile phase containing sodium octanesulfonate. The effluent was monitored with coulometric electrochemical detection at ca. + 0.76 V. The workup procedure recovered more than 95% of tiagabine from plasma. Standard curves were linear over the concentration range 0-500 ng/ml. The precision of the method was good: coefficients of variation were typically less than 5% for concentrations as low as 8 ng/ml and although they were higher at concentrations less than 8 ng/ml, they remained within acceptable limits (less than 17%) for concentrations as low as the limit of quantitation (2 ng/ml using a l-ml plasma sample). The stability of tiagabine in plasma was excellent, with no evidence of degradation after 23 h at room temperature or 2 months at -20 degrees C.  相似文献   

13.
微波萃取-气相色谱法测定血液中的甲基苯丙胺   总被引:2,自引:0,他引:2  
建立了人体血液中甲基苯丙胺的微波萃取-气相色谱测定方法。分别考察了萃取溶剂种类、用量、样品pH值以及萃取温度、时间等因素对萃取率的影响,并与液-液萃取法进行比较。结果表明,在相同条件下,微波萃取率高于液-液萃取。血液中甲基苯丙胺的最佳提取条件为:调节血样pH为13,以乙酸乙酯为萃取溶剂,于30 ℃下微波提取 8 min。在此条件下平均萃取率达到81.4%,相对标准偏差为6.4%(n=5)。提取液经气相色谱-氢火焰离子化检测器检测,甲基苯丙胺和基体之间得到了很好的分离,对血液中甲基苯丙胺的最低检测限为220 μg/L。该方法是一种快速、准确、灵敏的测定血液中甲基苯丙胺的方法。  相似文献   

14.
A liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay was developed and validated to determine valproic acid in human plasma. The method involved a solid-phase extraction of valproic acid and betamethasone valerate, an internal standard, from plasma and detection using an LC-MS/MS system with electrospray ionization source in negative ion mode. Separation was achieved within 3 min on a non-porous silica column with mobile phase containing ammonium acetate and methanol. Multiple reaction monitoring was utilized for detection monitoring at 142.89-142.89 for valproic acid and 457.21-457.21 for the internal standard. The calibration curve for valproic acid was linear over the range of 0.5-150 microg/mL. The limit of detection was 0.17 microg/mL and the lower limit of quantification was 0.5 microg/mL, when 0.2 mL plasma was used for extraction. The percentage coefficient of validation for accuracy and precision (inter- and intra-day) for this method was less than 9.5% with recovery ranging from 82.3 to 86.9% for valproic acid.  相似文献   

15.
An isocratic reversed-phase high-performance liquid chromatographic method has been developed for separation and simultaneous determination of COX-2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4-chloro-2-nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed-phase Inertsil C(18) column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0--20 microg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX-2 inhibitors with a detection limit of 0.127--1.040 microg/mL simultaneously.  相似文献   

16.
人血清中地尔硫高效液相色谱法测定及药代动力学参数   总被引:2,自引:0,他引:2  
李克  张昕  袁倚盛  罗楠  谭力 《色谱》1997,15(5):451-453
 建立了反相高效液相色谱法监测人口服地尔硫艹卓缓释片后血药浓度。血样用正己烷-氯仿-异丙醇混合溶剂(60405)提取后,以C18化学键合硅胶为固定相,甲醇-水-三乙胺为流动相,安定为内标,在239nm波长处定量检测。血药浓度在15~300μg/L范围内线性关系良好,最低检测浓度为3μg/L。批内(n=7)及批间(n=5)测定相对标准偏差分别小于6.8%和8.4%,回收率为91%~104%。监测了8名健康人口服盐酸地尔硫艹卓缓释片后的不同时间的血药浓度变化,计算了有关的药代动力学参数。  相似文献   

17.
Wang Y  Yang J  Cai Y  Lin X  Li H 《色谱》2011,29(12):1230-1235
以4-氯-7-硝基苯并-2-氧杂-1,3-二唑(NBD-Cl)为柱前衍生试剂,建立了胶束电动色谱-激光诱导荧光检测法测定肌松弛药巴氯芬(BAL)的新方法。经过实验条件的优化,采用15 mmol/L硼砂、20 mmol/L十二烷基硫酸钠、10%(v/v)乙腈、pH 9.75的缓冲体系,在分离电压为17.5 kV、柱温为25 ℃的条件下,压力进样3.45 kPa(0.5 psi)×3 s,巴氯芬及其内标物的衍生产物在7 min内实现较好的基线分离,线性范围为0.025~25 mg/L,相关系数为0.9999,检出限(S/N=3)和定量限(S/N=10)分别为0.90 μg/L和6.25 μg/L。该方法被应用于巴氯芬制剂及加入巴氯芬对照品的尿液样品分析,回收率范围分别为101.6%~107.9%和107.0%~109.6%。该方法有望应用于巴氯芬药物制剂的质量监控以及为巴氯芬药物代谢的研究提供辅助手段。  相似文献   

18.
A method was developed for the determination of rare earth elements (REEs) in urine with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICPMS). The undiluted sample was directly injected into the graphite tube and trifluoromethane (Freon-23) was used as chemical modifier in order to reduce the vaporization temperature and the memory effect of most of the lanthanides. The detection limits were in the range 1-10 ng/L with relative standard deviation of 3-5% at concentration levels of 1microg/L, and less than 10-15% at 100 ng/L. Two different procedures, external calibration and a standard additions method, were evaluated to measure the concentration levels of lanthanides in the urine samples and the second procedure was considered to be the best choice for calibration in this work. The level of REEs in urine of 50 healthy volunteers was in the range 5-20 ng/L, above the detection limit of ETV-ICPMS.  相似文献   

19.
建立了以固相萃取技术进行富集 ,高效液相色谱进行分离和检测邻甲苯胺和邻硝基甲苯的方法。污染水中的邻甲苯胺和邻硝基甲苯采用Sep pakC1 8萃取柱进行固相萃取。色谱分离条件是 :Shim PackCLCODS(1 5 0mm× 4 .6mmid ,5 μm)柱为分析柱 ,甲醇 水 =60∶4 0 (V V)为流动相 ,流速为 1 .0mL min,邻甲苯胺和邻硝基甲苯的紫外检测波长分别为 2 3 0nm和 2 5 4nm ,本法具有良好的灵敏度和重现性。  相似文献   

20.
A high-performance liquid chromatographic method has been developed for the quantification of 1-hydroxypyrene (1-OHP) in human urine using deuterated 1-hydroxypyrene ([2H9]1-OHP) as an internal standard with fluorescence detection. [2H9]1-OHP was prepared enzymatically from deuterated pyrene ([2H10]Pyr) with cytochrome P450 1A1. It eluted immediately prior to non-deuterated 1-OHP on alkylamide-type reversed-phase columns and had nearly the same fluorescence characteristics as non-deuterated 1-OHP. The detection limit was 0.1 microg/L and the calibration range was from 1 to 100 nmol/L. Urine sample treatment involved enzymatic hydrolysis followed by solid-phase extraction using Sep-Pak C18 cartridges. The proposed method was used to determine urinary 1-OHP in smokers and non-smokers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号