首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Purpose

In vivo magnetic resonance (MR) tracking of magnetically labeled bone marrow mesenchymal stem cells (BMSCs) administered via the mesenteric vein to rats with liver fibrosis.

Materials and Methods

Rat BMSCs were labeled with superparamagnetic iron oxide (SPIO) and the characteristics of the BMSCs after labeling were investigated. Eighteen rats with CCL4-induced liver fibrosis were randomized to three groups to receive SPIO-labeled BMSCs (BMSC-labeled group), cell-free SPIO (SPIO group), or unlabeled BMSCs (control group). MR imaging of the liver was performed at different time points, and signal-to-noise ratio (SNR) of the liver was measured. In vivo distribution of delivered BMSCs was assessed by histological analysis.

Results

Labeling of BMSCs with SPIO did not significantly alter cell viability and proliferation activity. In BMSC-labeled group, the liver SNR immediately decreased from 8.56±0.26 to 3.53±0.41 at 1 h post injection and remained at a significantly lower level till 12 days (P<.05 versus the level before). By contrast, the liver SNR of the SPIO group almost recovered to the preinjection level (P=.125) at 3 days after a transient decrease. In control group, the liver SNR demonstrated no significant difference at the tested time points. Additionally, Prussian blue-positive cells were mainly distributed in the liver parenchyma, especially in injured areas.

Conclusion

The magnetically labeled BMSCs infused through the mesenteric vein can be detected in the fibrotic liver of rats using in vivo MR imaging up to 12 days after injection.  相似文献   

2.

Object

Although three-dimensional (3D), high-spatial resolution susceptibility-weighted imaging (SWI) appears to be valuable in the evaluation of central nervous system gliomas, several evaluation methods are proposed in the literature. The purpose of this study was to evaluate the use of 3D SWI for grading intracranial gliomas with various analysis methods.

Materials and Methods

Twenty-three patients suspected of having gliomas participated in this study. SWI was performed in addition to conventional MR sequences. In 15 cases, post-gadolinium enhanced SWI was also obtained. Imaging evaluation criteria were conventional grade, hypointensity ratio in the tumor-dominant structure of hypointensity on SWI (hemorrhage or vascular structure) and presence of abnormal enhancement surrounding the tumor.

Results

Mean grading scores of conventional grade showed no statistically significant difference among WHO grades. Mean grading scores of hypointensity ratios in the tumor were higher for WHO Grades 3 and 4 than for lower grade tumors (P=.05, Mann–Whitney U test). Hemorrhagic foci were more frequently seen in the higher grade tumor. Post-contrast susceptibility-weighted images of five of 11 WHO Grade 3 and 4 cases showed bright enhancement surrounding the tumor, suggesting a breakdown of the blood–brain barrier.

Conclusions

SWI at 3 T may be a useful method to analyze the structural characteristics of gliomas and to evaluate pathology in vivo. Assessment of hypointensity ratios in the glioma was the most preferable method in grading glioma. However, more studies, specifically concerning a suitable method for image analysis, are needed to establish SWI at 3 T as a useful tool in clinical routine.  相似文献   

3.

Background and Aims

Diagnosis of liver disease has improved because of progress in imaging technology. Among the imaging methods, magnetic resonance imaging (MRI) has the advantage of a lack of radiation exposure, but the basis of the method (imaging of hydrogen atoms in water molecules) makes it hard to detect changes in tissue or the location of the diseased tissue in the liver. The aims of this study are to develop new contrast media for visualization of functional changes in the liver and to check the effectiveness of the media.

Methods

We developed a new molecular imaging contrast media that targets the asialoglycoprotein receptor (ASGP-R), a membrane protein that is specific to hepatocytes. We first checked the contrast media diameter and the cytotoxicity. Next, we examined the interaction of the media with ASGP-R through observation of fluorescein isothiocyanate (FITC)-labeled molecular imaging contrast media bound to normal hepatocellular ASGP-R using confocal laser scanning microscopy. Finally, we used MRI to observe hepatocyte interactions with the molecular imaging contrast media.

Results

The contrast media forms a nanoparticle of about 30 nm diameter in aqueous solution and the cytotoxicity is low. In vitro, the media has high specificity for ASGP-R in normal rat hepatocyte RLN-8 cells and this interaction was blocked by lactose (which has a similar molecular structure to that of galactose) and by an anti-ASGP-R antibody. The contrast media markedly enhanced T1-weighted images in MRI of normal rat hepatocytes compared to the signal strength for rat liver cancer cells.

Conclusions

We have shown that our new contrast media for molecular imaging of hepatocytes by MRI is effective in vitro.  相似文献   

4.

Objective

Development of a fast 3D high-resolution magnetic resonance imaging (MRI) protocol for improved carotid artery plaque imaging.

Methods

Two patients with carotid atherosclerosis disease underwent 3D high-resolution MRI which included time-of-flight and T1-weighted variable flip angle, fast-spin-echo (FSE) imaging, pre- and post-intravenous gadolinium-based contrast agent administration.

Results

Good quality images with intrinsic blood suppression were obtained pre- and post-contrast administration using a 3D FSE sequence. The plaque burden, lipid core volume, hemorrhage volume and fibrous cap thickness were well determined.

Conclusions

3D high-resolution MR imaging of carotid plaque using TOF and 3D FSE can achieve high isotropic resolution, large coverage, and excellent image quality within a short acquisition time.  相似文献   

5.

Purpose

Quantitative imaging of the rat skin was performed using magnetic resonance imaging (MRI) at 900 MHz.

Materials and methods

A number of imaging techniques utilized for multiple contrast included magnetization transfer contrast, spin-lattice relaxation constant (T1-weighting), combination of T2-weighting with magnetic field inhomogeneity (T2*-weighting), magnetization transfer weighting and diffusion tensor weighting. These were used to obtain 2D slices and 3D multislice-multiecho images with high magnetic resonance contrast. These 2D and 3D imaging techniques were combined to achieve high-resolution MRI.

Results

Oil–water phantom showed distinct fat-water contrast. The dermis and epidermis, including the stratum corneum remnants, of nude rat skin were distinct due to their proton magnetic resonance as a result of proton interactions with the skin interstitial tissue. Combined details obtained from high-resolution, high-quality ex vivo skin images with different multicontrast characteristics generated better differentiation of skin layers, sublayers and significant correlation (r2=0.4927 for MRI area, r2=0.3068 for histology area; P<.0148) of MR data with co-registered histological areas of the epidermis as well as the hair follicle.

Conclusion

The multiple contrast approach provided a noninvasive ex vivo MRI visualization with semi-quantitative assessment of the major skin structures including the stratum corneum remnants, epidermis, hair, papillary dermis, reticular dermis and hypodermis.  相似文献   

6.

Purpose

To remove the partial volume averaging effect of free water in MR diffusion imaging of neural tissues by use of the fluid attenuated inversion recovery (FLAIR) without the penalty of an extended scan time.

Materials and methods

The magnetic resonance images were obtained from a normal volunteer in a coronal slice orientation at 3 T with the 20-channel rf coil. In diffusion imaging only the b0 images were obtained with the FLAIR contrast while the diffusion weighted images were obtained without the FLAIR contrast. A composition of FLAIR b0 and non-FLAIR diffusion weighted images was used in calculating the diffusion tensor and fractional anisotropy after compensating the reduced signal amplitude due to the inversion recovery in the FLAIR b0 images. The fractional anisotropy of the non-FLAIR, FLAIR, and the composite methods were analyzed for the mean and histogram in the corpus callosum, cervical spine, and the fornix tracts.

Results

The partial volume averaging effect was observed in the corpus callosum, the cervical spine, and the fornix tracts in the non-FLAIR b0 and diffusion images. The partial volume averaging effect was removed in the FLAIR diffusion images which took more than twice the scan time than the non-FLAIR diffusion imaging. The proposed composite FLAIR diffusion imaging removed the partial volume averaging effect as in the FLAIR diffusion imaging. The distribution of the FA histogram was very different between the non-FLAIR and FLAIR diffusion images, while it was very similar between the FLAIR and the composite FLAIR after correcting the white matter signal in the FLAIR b0 images.

Conclusions

The proposed composite FLAIR diffusion imaging method was equally effective in removing the partial volume averaging effect as the FLAIR diffusion imaging at a limited increase of the scan time since only a small number of b0 images needed to be obtained with the FLAIR contrast.  相似文献   

7.

Objective

The purpose of this study is to determine the feasibility of measuring total uterine blood flow in pregnancy using magnetic resonance imaging (MRI) technique.

Methods

Uterine blood flow was determined in pregnant women in whom MRI was being carried out to assess a fetal anomaly. A two-dimensional time-of-flight magnetic resonance (MR) angiogram sequence was performed. Scout images and a peripherally gated phase contrast MR sequence were planned to study simultaneous blood flow in the uterine and ovarian arteries.

Results

The MR pelvic angiogram sequence was completed in 13 women. The uterine arteries were visualized and their cross-sectional area determined. The complexity of the pelvic blood supply prevented the calculation of blood flow velocity and, thus, total uterine blood flow.

Conclusion

The measurement of total uterine blood flow during pregnancy was not possible using our MR technique. The ovarian vessels were not consistently visualized. Doppler ultrasonography remains the best modality by which to estimate total uterine blood flow in pregnancy.  相似文献   

8.

Purpose

To optimize the navigator-gating technique for the acquisition of high-quality three-dimensional spoiled gradient-recalled echo (3D SPGR) images of the liver during free breathing.

Materials and methods

Ten healthy volunteers underwent 3D SPGR magnetic resonance imaging of the liver using a conventional navigator-gated 3D SPGR (cNAV-3D-SPGR) sequence or an enhanced navigator-gated 3D SPGR (eNAV-3D-SPGR) sequence. No exogenous contrast agent was used. A 20-ms wait period was inserted between the 3D SPGR acquisition component and navigator component of the eNAV-3D-SPGR sequence to allow T1 recovery. Visual evaluation and calculation of the signal-to-noise ratio were performed to compare image quality between the imaging techniques.

Result

The eNAV-3D-SPGR sequence provided better noise properties than the cNAV-3D-SPGR sequence visually and quantitatively. Navigator gating with an acceptance window of 2 mm effectively inhibited respiratory motion artifacts. The widening of the window to 6 mm shortened the acquisition time but increased motion artifacts, resulting in degradation of overall image quality. Neither slice tracking nor incorporation of short breath holding successfully compensated for the widening of the window.

Conclusion

The eNAV-3D-SPGR sequence with an acceptance window of 2 mm provides high-quality 3D SPGR images of the liver.  相似文献   

9.

Purpose

To investigate the influence of dual-source parallel radiofrequency (RF) excitation on clinical breast MR images.

Methods

A 3 T MR system with both dual-source and conventional single-source RF excitations was used to examine 22 patients. Axial TSE-T2WI with fat suppression, TSE-T1WI without fat suppression, THRIVE (3D field echo) and DWI (SE-EPI) were obtained by using both excitation techniques. Image homogeneity, image contrast and lesion conspicuity were measured or independently scored by two radiologists and were compared by paired-sample t test or Wilcoxon test.

Results

Both excitations revealed 24 lesions. For SE sequences using dual-source mode, image homogeneity was improved (P = 0.00), scan time was reduced, and ghost artifacts on DWI were significantly reduced (P = 0.00). However, image contrast was not increased and lesion conspicuity had no significant difference between two modes, except DWI on which lesion conspicuity was significantly improved (P = 0.00), due to less ghost artifacts. For field-echo sequence, image homogeneity, acquisition time, image contrast and lesion conspicuity had no significant difference between the two modes.

Conclusions

Dual-source parallel RF transmission has some added value for improving breast image quality. However, its value is limited in terms of improving lesion detection and characterization.  相似文献   

10.

Purpose

To investigate the feasibility of combining GESFIDE with PROPELLER sampling approaches for simultaneous abdominal R2 and R2* mapping.

Materials and Methods

R2 and R2* measurements were performed in 9 healthy volunteers and phantoms using the GESFIDE-PROPELLER and the conventional Cartesian-sampling GESFIDE approaches.

Results

Images acquired with the GESFIDE-PROPELLER sequence effectively mitigated the respiratory motion artifacts, which were clearly evident in the images acquired using the conventional GESFIDE approach. There was no significant difference between GESFIDE-PROPELLER and reference MGRE R2* measurements (p = 0.162) whereas the Cartesian-sampling based GESFIDE methods significantly overestimated R2* values compared to MGRE measurements (p < 0.001).

Conclusion

The GESFIDE-PROPELLER sequence provided high quality images and accurate abdominal R2 and R2* maps while avoiding the motion artifacts common to the conventional Cartesian-sampling GESFIDE approaches.  相似文献   

11.

Background

Using magnetic resonance (MR) imaging for navigating catheters has several advantages when compared with the current “gold standard” modality of X-ray imaging. A significant drawback to interventional MR is inferior temporal and spatial resolutions, as high spatial resolution images cannot be collected and displayed at rates equal to X-ray imaging. In particular, passive MR catheter tracking experiments that use positive contrast mechanisms have poor temporal imaging rates and signal-to-noise ratio. As a result, with passive methods, it is often difficult to reconstruct motion artifact-free tracking images from areas with motion, such as the thoracic cavity.

Methods

In this study, several accelerated MR acquisition strategies, including parallel imaging and compressed sensing (CS), were evaluated to determine which method is most effective at improving the frame rate and passive detection of catheters in regions of physiological motion. Device navigation was performed both in vitro, through the aortic arch of an anthropomorphic chest phantom, and in vivo from the femoral artery, up the descending aorta into the supra-aortic branching vessels in canines.

Results and Discussion

The different parallel imaging methods produced images of low quality. CS with a two-fold acceleration was found to be the most effective method for generating tracking images, improving the image frame rate to 5.2 Hz, while maintaining a relatively high in-plane resolution. Using CS, motion artifact was decreased and the catheters were visualized with good conspicuity near the heart.

Conclusions

The improvement in the imaging frame rate by image acceleration was sufficient to overcome motion artifacts and to better visualize catheters in the thoracic cavity with passive tracking. CS preformed best at tracking. Navigation with passive MR catheter tracking was demonstrated from the femoral artery to the carotid artery in canines.  相似文献   

12.

Objectives

To evaluate the performance of region-of-interest (ROI)-based MRI R2* measurements by using the first-moment noise-corrected model (M1NCM) to correct the non-central Chi noise in magnitude images from phased arrays for hepatic iron content (HIC) assessment.

Methods

R2* values were quantified using the M1NCM model. Three approaches were employed to determine the representative R2*: fitting of the ROI-averaged signal (average-then-fit, ATF); outputting the median and mean of R2*s from the pixel-wise fitting of decay signals within the ROI (denoted as PWFmed and PWFmea, respectively). The accuracy and precision of the three approaches were evaluated on synthesized data. The agreement among these approaches and their intra- and inter-observer reproducibility were assessed on 105 thalassaemia major patients.

Results

Simulations showed that ATF consistently yielded the highest accuracy and precision at varying noise levels. By contrast, PWFmed and PWFmea slightly and significantly overestimated high R2* at poor signal-to-noise ratios, respectively. Patient study showed that ATF agreed well with PWFmed, whereas PWFmea produced high R2* measurements for patients with severe HIC. No significant difference was observed in the reproducibility of the three approaches.

Conclusions

PWFmea tends to overestimate high R2*, whereas ATF and PWFmed can produce more accurate R2* measurements for HIC assessment.  相似文献   

13.

Purpose

To visualize liver uptake function using the uptake contrast-enhanced ratio in hepatobiliary phase (uptake CERH) magnetic resonance imaging.

Materials and methods

Thirty-seven patients with hepatocellular carcinoma (HCC) and 23 with metastatic liver cancer were evaluated. Hepatobiliary phase images were acquired 20 min after an intravenous bolus injection of gadoxetic acid disodium. We assumed that the contrast-enhanced ratio in the hepatobiliary phase (CERH) in the spleen was similar to the contrast-enhanced ratio in the extracellular matrix (CEREM). The Uptake CERH value was defined as the percentage signal gain between the precontrast and hepatobiliary phase images (without CEREM). The Uptake CERH value measured the tumor-free liver parenchyma. The association of the uptake CERH value with the biochemical liver function test results, and hepatocellular density in the liver parenchyma was assessed. Correlations were examined using Pearson correlation coefficient and the Mann–Whitney test.

Results

The uptake CERH value was correlated with albumin, bilirubin, indocyanine green retention rate at 15 min, prothrombin activity(%), platelet count, and cellular density in the liver parenchyma (p < 0.01).

Conclusions

Uptake CERH images are useful for visualizing liver uptake function.  相似文献   

14.

Purpose

The regional uptake of glucose in rat brain in vivo was measured at high resolution using spin-lock magnetic resonance imaging after infusion of the glucose analogue 2-deoxy-d-glucose (2DG). Previous studies of glucose metabolism have used 13C-labeled 2DG and NMR spectroscopy, 18F-labeled fluorodeoxyglucose (FDG) and PET, or chemical exchange saturation transfer (CEST) MRI, all of which have practical limitations. Our goal was to explore the ability of spin-lock sequences to detect specific chemically-exchanging species in vivo and to compare the effects of 2DG in brain tissue on CEST images.

Methods

Numerical simulations of R1p and CEST contrasts for a variety of sample parameters were performed to evaluate the potential specificity of each method for detecting the exchange contributions of 2DG. Experimental measurements were made in tissue phantoms and in rat brain in vivo which demonstrated the ability of spin-lock sequences for detecting 2DG.

Results

R1p contrast acquired with appropriate spin-lock sequences can isolate the contribution of exchanging protons in 2DG in vivo and appears to have better sensitivity and more specificity to 2DG–water exchange effects than CEST.

Conclusion

Spin-lock imaging provides a novel approach to the detection and measurement of glucose uptake in brain in vivo.  相似文献   

15.

Purpose

The aim of this study is to investigate whether subserosal enhancement on the delayed-phase dynamic magnetic resonance (MR) study (SED) can differentiate T2 from T1 gallbladder carcinoma (GBC).

Methods

The institutional research board approved this retrospective study. Between 1997 and 2006, there were surgically proven 11 T1 and 21 T2 GBC in 30 patients, all of whom had undergone preoperative contrast enhanced dynamic MR study, either with a 2D sequence (n=17) or 3D sequences (n=15). All images were reviewed by two radiologists for the presence of SED, and receiver operating characteristic (ROC) curve analysis was performed. Sensitivity, specificity, positive and negative predictive values were calculated by consensus.

Results

The areas under the ROC curves of the two readers were 0.91 and 0.86, and the kappa value was 0.78. Of the 21 T2 GBC, 18 and 3 showed positive and negative SED, respectively. Of the 11 T1 GBC, 1 and 10 showed positive and negative SED, respectively. The sensitivity, specificity, positive and negative predictive values of SED for diagnosing T2 lesions were 86%, 88%, 91% and 77%, respectively.

Conclusions

In conclusion, SED may be a useful sign to differentiate T2 from T1 GBC, which would affect the preoperative surgical planning of the patients.  相似文献   

16.

Purpose

Magnetic resonance images of biological media based on chemical exchange saturation transfer (CEST) show contrast that depends on chemical exchange between water and other protons. In addition, spin–lattice relaxation rates in the rotating frame (R1ρ) are also affected by exchange, especially at high fields, and can be exploited to provide novel, exchange-dependent contrast. Here, we evaluate and compare the factors that modulate the exchange contrast for these methods using simulations and experiments on simple, biologically relevant samples.

Methods

Simulations and experimental measurements at 9.4 T of rotating frame relaxation rate dispersion and CEST contrast were performed on solutions of macromolecules containing amide and hydroxyl exchanging protons.

Results

The simulations and experimental measurements confirm that both CEST and R1ρ measurements depend on similar exchange parameters, but they manifest themselves differently in their effects on contrast. CEST contrast may be larger in the slow and intermediate exchange regimes for protons with large resonant frequency offsets (e.g. > 2 ppm). Spin-locking techniques can produce larger contrast enhancement when resonant frequency offsets are small (< 2 ppm) and exchange is in the intermediate-to-fast regime. The image contrasts scale differently with field strength, exchange rate and concentration.

Conclusion

CEST and R1ρ measurements provide different and somewhat complementary information about exchange in tissues. Whereas CEST can depict exchange of protons with specific chemical shifts, appropriate R1ρ-dependent acquisitions can be employed to selectively portray protons of specific exchange rates.  相似文献   

17.

Purpose

To investigate the image quality and detection rate of focal liver lesions by comparing a T2-weighted breath-hold single-shot sequence and a T2-weighted high spatial resolution fast spin-echo sequence with respiratory triggering via unenhanced and superparamagnetic iron oxide (SPIO)-enhanced liver imaging.

Materials and Methods

The study was approved by the local ethical review board; informed consent was waived. Liver-lesion contrast was measured and a qualitative consensus evaluation of image quality and lesion detection was performed in 42 consecutive patients using a 1.5-T MR system.

Results

The liver-lesion contrast was significantly higher (P<.05) for the respiratory-triggered sequence compared to the breath-hold sequence regarding unenhanced and SPIO-enhanced imaging. The respiratory-triggered sequences revealed significantly higher image quality scores as well as higher numbers of detected liver lesions compared to the breath-hold sequence on unenhanced and SPIO-enhanced imaging. The SPIO contrast did not significantly improve the number of detected lesions on the respective sequences (P>.05).

Conclusion

We find that respiratory-triggered fast spin-echo sequences produce a higher image quality and a more precise liver-lesion detection rate thereby justifying the increased acquisition time necessary for this method.  相似文献   

18.

Objective

The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI).

Methods

Seventeen patients with PD and 15 age-matched healthy controls underwent DKI with a 3-T MR imager. Diffusion tensor tractography images of the anterior and posterior cingulum were generated. The mean kurtosis (MK) and conventional diffusion tensor parameters measured along the images in the anterior and posterior cingulum were compared between the groups. Receiver operating characteristic (ROC) analysis was also performed to compare the diagnostic abilities of the MK and conventional diffusion tensor parameters.

Results

The MK and fractional anisotropy (FA) in the anterior cingulum were significantly lower in PD patients than in healthy controls. The area under the ROC curve was 0.912 for MK and 0.747 for FA in the anterior cingulum. MK in the anterior cingulum had the best diagnostic performance (mean cutoff, 0.967; sensitivity, 0.87; specificity, 0.94).

Conclusions

DKI can detect alterations of the anterior cingulum in PD patients more sensitively than can conventional diffusion tensor imaging. Use of DKI can be expected to improve the ability to diagnose PD.  相似文献   

19.

Purpose

To investigate intracranial microvascular images with transceiver radio-frequency (RF) coils at ultra-high field 7 T magnetic resonance imaging (MRI).

Materials and methods

We designed several types of RF coils for the study of 7 T magnetic resonance angiography and analyzed quantitatively each coil's performance in terms of the signal-to-noise ratio (SNR) profiles to evaluate the usefulness of RF coils for microvascular imaging applications. We also obtained the microvascular images with different resolutions and parallel imaging technique.

Results

The overlapped 6-channel (ch) transceiver coil exhibited the highest performance for angiographic imaging. Although other multi-channel coils, such as 4- or 8-ch, were also suitable for fast imaging, these coils performed poorly in homogeneity or SNR for angiographic imaging. Furthermore, the 8-ch coil was poor in SNR at the center of the brain, while it had the highest SNR at the periphery.

Conclusion

The present study has demonstrated that the overlapped 6-ch coil with large-size loop coils provided the best performance for microvascular imaging or angiography with the ultra-high-field 7 T MRI, mainly because of its long penetration depth together with high SNR.  相似文献   

20.

Purpose

The purpose of this study was to evaluate enhancement characteristics of histopathologically confirmed focal nodular hyperplasia (FNHs) with gadoxetic acid-enhanced MRI.

Materials and Methods

Twenty-seven patients with all histopathologically proven FNHs were retrospectively identified. MRI consisted of T1- and T2-weighted (w) sequences with and without fat saturation (FS), multiphase dynamic T1-w images, and FS T1-w images during the hepatobiliary phase. Standard of reference was surgical resection (n = 24) or biopsy (n = 3). Images were analyzed for morphology and contrast behavior including signal intensity (SI) measurement on T1-w images normalized to the pre-contrast base line.

Results

In total 36 FNHs were evaluated. All FNHs showed enhancement in the arterial phase, significant reduction contrast enhancement (“wash-out”) in the late dynamic phases was not present. In the hepatobiliary phase, all FNHs (100%) showed enhancement (overall SI increase, 118% (± 91%), P < 0.001) with at least partial hyperintensity to the liver. Upon visual comparison, 3 of 36 FNHs appeared with heterogeneous/partial enhancement (8%) and 7 (19%) showed rim-accentuated enhancement.

Conclusion

The typical enhancement pattern of FNH with gadoxetic acid consists of arterial hyperperfusion, no wash-out during the venous phase, and at least partial hyperintensity compared to the liver in the hepatobiliary phase. Partial hypointensity or rim-accentuated enhancement rarely occurs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号