1.
A highly sensitive and relatively interference-free spectrophotometric method for determination of calcium is described. The method is based on the reaction between calcium ions and carboxyazo-p-CH3 in aqueous citrate medium of pH 7, to form a blue complex with maximum absorption at 716 nm. The calibration is linear up to 0.12 μg ml−1 calcium with a repeatability (R.S.D.) of 1.0% at a concentration of 0.04 μg ml−1 (n=5). The molar absorptivity of the complex and Sandell’s sensitivity are 3.5×105 l mol−1 cm−1 and 0.11 ng cm−2, its 10σ limit of quantification and the 3σ limit of detection were found to be 0.3 ng ml−1 and 0.09 ng ml−1 respectively. The influence of reaction variables and the effect of interfering ions are studied; no interference was observed in clinical samples. The proposed method has been applied directly to the determination of calcium in clinical samples without the need for pre-concentration, masking metal ions and digesting samples.  相似文献   

2.
A simpler UV-vis spectrophotometric method was investigated for hydroquinone (HQ) determination using KMnO4 as oxidizing agent for conversion of HQ to p-benzoquinone (BQ) as well as signal enhancer. Various parameters such as analytical wavelength, stability time, temperature, pH, solvent effect and interference of chemicals were checked and parameters optimized by using 1 μg ml−1 standard solution of HQ. Beer's Law was applicable in the range of 0.07-2 μg ml−1 and 0.005-0.05 μg ml−1 at 245.5 nm and at 262 nm for aqueous standard solutions of HQ with linear regression coefficient value of 0.9978 and 0.9843 and detection limit of 0.021 μg ml−1 and 0.0016 μg ml−1 HQ, respectively. Standard deviation of 1.7% and 2.4% was true for 1 μg ml−1 and 0.03 μg ml−1 HQ solution (n = 11) run at respective wavelengths. The method was successfully applied to dilute waste photographic developer samples for free HQ determination.  相似文献   

3.
Tagitinin C, an antiplasmodial compound, identified as one major compound of the subtropical medicinal plant, Tithonia diversifolia, was determined by FT-IR spectroscopy method. The crude ether extracts from aerial parts of the plant were evaporated to dryness and re-dissolved in tetrachloroethylene (C2Cl4) before analysis.The magnitude of the absorbance of the very specific CO stretching vibration (νCO) at 1664.8 cm−1 was exploited in order to quantify tagitinin C. The determination coefficient (r2) of the calibration scale was 0.9994, the detection limit was lower than 3 μg ml−1 and the quantification limit was lower than 10 μg ml−1.Recovery values from 100.5 to 101.7% were found for spiked concentration levels from 19.91 to 89.95 μg ml−1. The main characteristics of the curves obtained from the calibration standards and from the standard addition technique were not statistically different (Student t-test) suggesting that matrix effects were negligible.The results obtained for the determination of tagitinin C in the crude ether extract from aerial parts of T. diversifolia by LC and FT-IR spectroscopic method agreed well: 0.76±0.02 and 0.773±0.009, of tagitinin C in dried plant respectively.  相似文献   

4.
Fenitrooxon [O,O-dimethyl-O-(4-nitro-m-tolyl)phosphate] is the major metabolite of the organophosphorus insecticide fenitrothion, and 3-methyl-4-nitrophenol is its major degradation product. In the present study, we describe the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of these compounds in water samples based on a group-specific polyclonal antiserum generated with a “bifunctional hapten”, which has two functions: the conventional function of producing an antibody against an antigen and a unique function of promoting the production of the antibodies in rabbit. For application to water samples, the influence of several factors such as organic solvent, pH, and detergent was studied. Under optimized conditions, the quantitative working range of the fenitrooxon ELISA was 0.71-27 ng ml−1 with a limit of detection (LOD) of 0.32 ng ml−1, and the fenitrooxon concentration giving 50% reduction of the maximum signal (IC50) was 4.2 ng ml−1. The quantitative working range of the 3-methyl-4-nitrophenol ELISA was 0.67-27 ng ml−1 with a LOD of 0.38 ng ml−1 and an IC50 of 3.7 ng ml−1. No significant matrix effect originating from the water sample (river water, tap water, purified water, and bottled water) was shown by addition of Tween 20 to the assay buffer. Water samples spiked with each of these compounds at 1, 5, 10, and 20 ng ml−1 were directly analyzed without extraction and clean-up by the proposed ELISA. The mean recovery was 100.9%, and the mean coefficient of variation (CV) was 7.7% for the fenitrooxon ELISA and for the 3-methyl-4-nitrophenol ELISA, the mean recovery was 97.6%, and the mean CV was 7.2%. The proposed ELISA allows precise and accurate determination of these compounds in water at such low levels.  相似文献   

5.
A novel kinetic chemiluminescent method using the stopped-flow mixing technique has been investigated for the rapid and sensitive determination of citrate and pyruvate. The method is based on a tris(2,2′-bipyridiyl)ruthenium(III) (Ru(bpy)33+) chemiluminescence (CL) reaction. Ru(bpy)33+ was generated in the mixing chamber by oxidising tris(2,2′-bipyridyl)ruthenium(II) with cerium(IV). After selecting the best operating parameters, calibration graphs were obtained over the concentration ranges 0.38-38 μg ml−1 and 8.7-1300 ng ml−1 for citrate and pyruvate, respectively. The limits of detection were 0.1 μg ml−1 for citrate and 0.3 ng ml−1 for pyruvate. Based on the differential rate of the chemiluminescent reaction corresponding to citrate and pyruvate, a very simple kinetic procedure was developed for the simultaneous determination of both compounds. Mixtures of citrate and pyruvate in ratios between 15:1 and 1.5:1 were satisfactorily resolved. The proposed method was successfully applied to the determination of citrate in pharmaceutical formulations, pyruvate in animal blood serum and both compounds in human urine.  相似文献   

6.
Jiang H  Hu B  Jiang Z  Qin Y 《Talanta》2006,70(1):7-13
A new method using a microcolumn packed with YPA4 chelating resin as solid-phase extractor has been developed for the separation and preconcentration of trace Hg prior to its measurement by GFAAS with Pd as a permanent modifier. Various parameters such as the amount of the modifier, pH, sample flow rate, the concentration and volume of eluent have been studied in order to find the best conditions for the determination of mercury. The detection limit of the method (3σ) for Hg based on an enrichment factor of 100 was 0.2 ng ml−1. A characteristic mass of 114 pg was obtained for mercury using Pd as a permanent modifier. The relative standard deviation was 2.8% at the 10 ng ml−1 level (n = 5). The method has been applied to the determination of trace mercury in environmental water samples and the recoveries for the spiked samples are in the range of 91-105%.  相似文献   

7.
A new capillary electrophoresis (CE) method for the determination of quinolizidine alkaloids in Sophora medicinal plants was developed. A total of seven alkaloid components (cytisine, sophocarpine, matrine, lehmannine, sophoranol, oxymatrine and oxysophocarpine) were separated within 15 min. The running buffer was a 50 mM phosphate buffer containing 1%HP-β-CD and 3.3% isopropanol. The linear calibration ranges were 5.50-88.0 μg ml−1 for cytisine and lehmannine, 5.00-88.0 μg ml−1 for sophocarpine and sophoranol, 5.60-89.6 μg ml−1 for matrine and oxysophocarpine, and 24.0-384 μg ml−1 for oxymatrine. The recoveries of the seven alkaloids were 96.0-102.9% with relative standard deviations from 1.50 to 3.00% (n = 5). The method was successfully applied to different Sophora medicinal plants including Sophora flavescens, Sophora tonkinensis and Sophora alopecuroides.  相似文献   

8.
The inhibitory effects of five hydroxyanthraquinones (HAQs) from root and rhizoma of Rheum officinale Baill, a traditional Chinese medicinal (TCM) herb, on Staphylococcus aureus growth were investigated by calorimetry. The power-time curves of S.aureus with and without HAQ were acquired and the extent and duration of inhibitory effects on the metabolism evaluated by growth rate constants (k1, k2), half inhibitory ratio (IC50), maximum heat output (Pmax) and peak time (tp). The value of k1 and k2 of S. aureus in the presence of the five HAQs decreased with the increasing concentrations of HAQs. Moreover, Pmax was reduced and the value of tp increased with increasing concentrations of the five drugs. The inhibitory activity varied for different drugs. IC50 of the five HAQs was 4 μg ml−1 for emodin, 3.5 μg ml−1 for rhein, 10 μg ml−1 for aloe-emodin, 1000 μg ml−1 for chrysophanol, 1600 μg ml−1 for physcion. The sequence of antimicrobial activity of the five HAQs: rhein > emodin > aloe-emodin > chrysophanol > physicion.  相似文献   

9.
《Analytica chimica acta》2003,476(1):141-148
A flow injection (FI) system combined with two photochemical processes is developed for the sensitive and rapid determination of carbaryl. It is based on the on-line photo-conversion of carbaryl into methylamine which subsequently reacts with Ru(bpy)33+ generated through the on-line photo-oxidation of Ru(bpy)32+ with peroxydisulphate. The linear concentration range of application was 0.04-4.0 μg ml−1 of carbaryl, with an R.S.D. of 1.2% (for a level of 0.50 μg ml−1) and a detection limit of 0.012 μg ml−1. The sample throughput was 200 injections per hour. The applicability of the method was demonstrated by determining carbaryl in commercial formulations, water, soil, grain and blood serum.  相似文献   

10.
A simple and sensitive indirect spectrophotometric method is described for the determination of mimosine based on its reaction with diazotized sulfanilamide (DZSAM). DZSAM couples with N-(1-naphthyl)ethylenediamine (NEDA) forming a pink colored azodye, absorbing maximally at 540 nm (εmax=27 mM−1 cm−1). In the present method, mimosine was first reacted with known excess of DZSAM and the unreacted DZSAM was determined by coupling with NEDA. The reaction of mimosine with DZSAM proceeded optimally at neutral pH. The decrease in absorbance of the DZSAM-NEDA-coupled product obeyed Beer’s law in the concentration range of 0.005-0.15 μg ml−1 of mimosine. The present method was applied to estimate mimosine in plant extracts containing lesser than 0.05 μg ml−1 with recovery at 99±0.41%. The method described is superior to other reported methods in terms of ease of adaptability and sensitivity.  相似文献   

11.
The intra- and the inter-chain magnetic interactions in [Ni(chxn)2Br]Br2, which is one of the typical one-dimensional (1-D) MX complexes are examined by using an unrestricted hybrid DFT (UB3LYP) method. Calculated effective exchange integral (J) value along the 1-D chain is 2JIntra = −4016 K and is close to an experimental result (−3600 K). On the other hand, a very weak anti-ferromagnetic inter-chain interaction through Br ions is observed. The value is estimated to be 2JInter = −2 to −6 K. In addition to the J values, transfer integral (t), on-site Coulomb repulsion (U) and charge transfer energy (ECT) values along the 1-D chain are also estimated to be 0.46, 2.46 and 0.6 eV, respectively.  相似文献   

12.
Wang Z  Zhang Z  Fu Z  Luo W  Zhang X 《Talanta》2004,62(3):611-617
A novel and sensitive chemiluminescence (CL) method for the determination of aminomethylbenzoic acid and aminophylline coupled with flow-injection analysis (FIA) technique is developed in this paper. It is based on the inhibition effect of the studied drugs on the chemiluminescence emission of N-bromosuccinimide-luminol (NBS-luminol) system. Under the optimum conditions, the decreased CL intensity is linear with the concentration of aminomethylbenzoic acid in the range of 2×10−8 to 1.0×10−6 g ml−1 and with the concentration of aminophylline in the range of 1×10−7 to 7.0×10−6 g ml−1, respectively. The detection limit is 7.0×10−9 g ml−1 for aminomethylbenzoic acid (3σ) and 3.4×10−8 g ml−1 for aminophylline (3σ). The relative standard deviations (R.S.D.) for 11 parallel measurements of 2.0×10−7 g ml−1 aminomethylbenzoic acid and 1.0×10−6 g ml−1 aminophylline are 2.6 and 3.0%, respectively. The proposed methods have been applied for the determination of the studied drugs in their pharmaceutical formulations with satisfactory results. The possible use of the proposed system for the determination of aminomethylbenzoic acid in plasma sample was also tested. The possible inhibition mechanism of aminomethylbenzoic acid and aminophylline on luminol-NBS system was discussed briefly.  相似文献   

13.
Based on direct hapten coated format a competitive indirect enzyme-linked immunosorbent assay (ciELISA) for bisphenol A (BPA) was developed. Polystyrene surface was modified by 3-Aminopropyltriethoxysilane (APTES) to produce amino groups after H2SO4/HNO3-pre-treatment. 4,4-bis (4-hydroxyphenyl) valeric acid (BVA) which is analogue of BPA, was successfully immobilized on the surface of microtiter plates by N,N′-dicyclohexylcarbodiimide (DCC) method. The essential steps of the assay were optimized, especially blocking procedure which is key step to prevent unspecific binding of antibody. The results indicated that compared with hapten-protein coated format (IC50 = 176.67 ng ml−1, LOD = 15.90 ng ml−1), the direct hapten coated format (IC50 = 23.50 ng ml−1, LOD = 0.27 ng ml−1) could improve assay sensitivity and the detection ranges were 2.30 ng∼157.60 ng ml−1 with good signal reproducibility (P value > 0.05) after careful optimization of assay conditions. Tap water samples and seawater samples were spiked with a known amount of BPA and measured by ciELISA. The average recoveries were between 70 and 142%. As far as we are aware this is the most sensitive ELISA for BPA yet reported.  相似文献   

14.
Li Zaijun  Wang Zhongyun  Fang Yinjun 《Talanta》2010,80(5):1632-1027
The paper describes a sensitive and highly stable label-free electrochemical impedance immunosensor for the determination of aflatoxin B1 (AFB1), which is based on the formation of silica gel-ionic liquid biocompatible film on the glassy carbon electrode. The electrochemical performances of the sensor were investigated by electrochemical impedance spectroscopy using a Fe(CN)63−/4− phosphate buffer solution as base solution for test. As new ionic liquid, 1-amyl-2,3-dimethylimidazolium hexafluorophosphate, offers a very biocompatible microenvironment for AFB1 antibody, the sensor exhibits good repeatability (RSD = 1.2%), sensitive electrochemical impedance response to AFB1 in the range of 0.1-10 ng ml−1 and lowers the detection limit of AFB1 (0.01 ng ml−1). The electron-transfer resistance change of the sensor after and before incubation with AFB1 of 2.0 ng ml−1 can retain 95% over a 180-day storage period at 4 °C. The results present a remarkable improvement of sensitivity (2-fold) and long-term stability (190-fold) when compared to classical silica gel sensor. Moreover, proposed sensor has a high selectivity to AFB1 alone with no significant response to AFB2, AFG1, AFG2 and AFM1 as single substrates, it has been successfully applied to the determination of trace AFB1 in bee pollen samples with a spiked recovery in the range of 96.0-102.5%.  相似文献   

15.
Zhang H  Tang B  Wang Y 《Talanta》2004,63(4):825-831
A supramolecular catalytic kinetic spectrofluorimetric method was developed for the determination of osmium(IV) and the possible mechanism of catalytic reaction was discussed. The method is based on the fluorescence enhancing reaction of o-vanillin furfuralhydrazone (OVFH) with potassium bromate, which was catalysed by osmium(IV) in water medium. Beta-cyclodextrin (beta-CD) obviously sensibilized the determination at pH 6.10 and 55 °C. Under optimum conditions, beta-CD-osmium(IV)-KBrO3-OVFH supramolecular kinetic catalytic reaction system had excitation and emission maxima at 337 and 490 nm, respectively. The linear range of this method was 0-120 ng ml−1 with a R.S.D. of 1.1%, and the detection limit was 0.38 ng ml−1. The effect of interferences was studied. Distillation was used to separate osmium from interfering elements in the samples. The proposed method was applied successfully to determine osmium(IV) in synthetic mixture and mineral samples, the results were well consistent with the reference standard values.  相似文献   

16.
An electrochemiluminescence (ECL)-based method for rapid and sensitive detection of acridinium ester in neutral solution was described. Strong ECL emission was observed when a positive voltage over 2.0 V (versus Ag/AgCl) was applied to the working electrode (Pt) immersed in the acridinium ester solution of 2.0 mol l−1 KNO3 (pH 7.0). The possible ECL mechanism was discussed. It was proposed that the ECL emission came out of N-methylacridone, the oxidization product of acridinium ester by the nascent oxygen generated on the surface of working electrode in the course of oxidization of water. Other influenced factors including the electrochemical parameters, the ECL reaction medium and pH value, were investigated in detail. Under the optimal conditions, ECL intensity has a linear relationship with the concentration of acridinium ester in the range of 0.24-96 ng ml−1 (r=0.9999). The relative standard deviation for 24 ng ml−1 acridinium ester was 4.6% (n=11). The limit of detection was 0.16 ng ml−1.  相似文献   

17.
Baytak S  Zereen F  Arslan Z 《Talanta》2011,84(2):319-323
A trace element preconcentration procedure is described utilizing a minicolumn of yeast (Yamadazyma spartinae) immobilized TiO2 nanoparticles for determination of Cr, Cu, Fe, Mn, Ni and Zn from water samples by inductively coupled plasma atomic emission spectrometry. The elements were quantitatively retained on the column between pH 6 and 8. Elution was made with 5% (v/v) HNO3 solution. Recoveries ranged from 98 ± 2 (Cr) to 100 ± 4 (Zn) for preconcentration of 50 mL multielement solution (50 μg L−1). The column made up of 100 mg sorbent (yeast immobilized TiO2 NP) offers a capacity to preconcentrate up to 500 mL of sample solution to achieve an enrichment factor of 250 with 2 mL of 5% (v/v) HNO3 eluent. The detection limits obtained from preconcentration of 50 mL blank solutions (5%, v/v, HNO3, n = 11) were 0.17, 0.45, 0.25, 0.15, 0.33 and 0.10 μg L−1 for Cr, Cu, Fe, Mn, Ni and Zn, respectively. Relative standard deviation (RSD) for five replicate analyses was better than 5%. The retention of the elements was not affected from up to 500 μg L−1 Na+ and K+ (as chlorides), 100 μg L−1 Ca2+ (as nitrate) and 50 μg L−1 Mg2+ (as sulfate). The method was validated by analysis of freshwater standard reference material (SRM 1643e) and applied to the determination of the elements from tap water and lake water samples.  相似文献   

18.
A series of spinel-type CoxNi1−xFe2O4 (x = 0, 0.2, 0.4, 0.5, 0.6, 0.8, 1.0) magnetic nanomaterials were solvothermally synthesized as enzyme mimics for the eletroctrocatalytic oxidation of H2O2. X-ray diffraction and scanning electron microscope were employed to characterize the composition, structure and morphology of the material. The electrochemical properties of spinel-type CoxNi1−xFe2O4 with different (Co/Ni) molar ratio toward H2O2 oxidation were investigated, and the results demonstrated that Co0.5Ni0.5Fe2O4 modified carbon paste electrode (Co0.5Ni0.5Fe2O4/CPE) possessed the best electrocatalytic activity for H2O2 oxidation. Under optimum conditions, the calibration curve for H2O2 determination on Co0.5Ni0.5Fe2O4/CPE was linear in a wide range of 1.0 × 10−8–1.0 × 10−3 M with low detection limit of 3.0 × 10−9 M (S/N = 3). The proposed Co0.5Ni0.5Fe2O4/CPE was also applied to the determination of H2O2 in commercial toothpastes with satisfactory results, indicating that CoxNi1−xFe2O4 is a promising hydrogen peroxidase mimics for the detection of H2O2.  相似文献   

19.
A novel flow-injection spectrophotometry has been developed for the determination of molybdenum(VI) at nanograms per milliliter levels. The method is based on the catalytic effect of molybdenum(VI) on the bromate oxidative coupling of p-hydrazinobenzenesulfonic acid with N-(1-naphthyl)ethylenediamine to form an azo dye (λmax = 530 nm). Chromotropic acid (4,5-dihydroxy-2,7-naphthalenedisulfonic acid) acted as an effective activator for the molybdenum(VI)-catalyzed reaction and increased the sensitivity of the method. The reaction was monitored by measuring the change in absorbance of the dye produced. The proposed method allowed the determination of molybdenum(VI) in the range 1.0-20 ng mL−1 with sample throughput of 15 h−1. The limit of detection was 0.5 ng mL−1 and a relative standard deviation for 10 ng mL−1 molybdenum(VI) (n = 10) was 2.5%. The interfering ions were eliminated by using the combination of a masking agent and on-line minicolumn packed with cation exchanger. The present method was successfully applied to the determination of molybdenum(VI) in plant foodstuffs.  相似文献   

20.
A systematic thermodynamic and kinetic study of the entire SFxCl (x = 0-5) series has been carried out. High-level quantum chemical composite methods have been employed to derive enthalpy of formation values from calculated atomization and isodesmic energies. The resulting values for the SCl, SFCl, SF2Cl(C1), SF3Cl(Cs), SF4Cl(Cs) and SF5Cl molecules are 28.0, −36.0, −64.2, −134.3, −158.2 and −237.1 kcal mol−1. A comparison with previous experimental and theoretical values is presented. Statistical adiabatic channel model/classical trajectory, SACM/CT, calculations of selected complex-forming and recombination reactions of F and Cl atoms with radicals of the series have been performed between 200 and 500 K. The reported rate coefficients span over the normal range of about 6 × 10−12 and 5 × 10−11 cm3 molecule−1 s−1 expected for this type of barrierless reactions.  相似文献   