首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The current study aims to develop a specific and sensitive LC-MS/MS method for determination of bis(7)-tacrine (B7T) in rat plasma. A 100 microL plasma sample was extracted with ethyl acetate. B7T and the internal standard (IS), pimozide, in the samples were then analyzed with LC-MS/MS in positive electrospray ionization condition. Chromatographic separation of B7T and IS was achieved in a C(18) reversed-phase HPLC column (150 x 2.1 mm i.d.) by isocratic elution with a mobile phase consisting of 0.05% formic acid in water and acetonitrile (1:1, v/v) at a flow rate of 0.35 mL/min. Multiple-reaction monitoring (MRM) mode was employed to measure the ion transitions: m/z 247 to 197 for B7T and m/z 462 to m/z 328 for IS, respectively. The method was linear over the studied ranges of 100-5000 and 10-100 ng/mL. The intra-day and inter-day variations of the analysis were less than 6.8% with standard errors less than 9.0%. The detection limit of B7T in rat plasma was 1 ng/mL. The developed method was successfully applied to the pharmacokinetic study of B7T after intravenous administration of 1 mg/kg B7T and further proved to be readily utilized for determination of B7T in rat plasma samples.  相似文献   

2.
We developed a method for determining pravastatin or pitavastatin, 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors, in plasma using liquid chromatography and tandem mass spectrometry (LC-MS/MS). Pravastatin, pitavastatin and the internal standard fluvastatin were extracted from plasma with solid-phase extraction columns and eluted with methanol. After drying the organic layer, the residue was reconstituted in mobile phase (acetonitrile:water, 90:10, v/v) and injected onto a reversed-phase C(18) column. The isocratic mobile phase was eluted at 0.2 mL/min. The ion transitions recorded in multiple reaction monitoring mode were m/z 423 --> 101, 420 --> 290 and 410 --> 348 for pravastatin, pitavastatin and fluvastatin, respectively. The coefficient of variation of the assay precision was less than 12.4%, the accuracy exceeded 89%. The limit of detection was 1 ng/mL for all analytes. This method was used to measure the plasma concentration of pitavastatin or pravastatin from healthy subjects after a single 4 mg oral dose of pitavastatin or 40 mg oral dose of pravastatin. This is a very simple, sensitive and accurate analytic method to determine the pharmacokinetic profiles of pitavastatin or pravastatiny.  相似文献   

3.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

4.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

5.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of zafirlukast (ZFK) with 500 microL human plasma using valdecoxib as an internal standard (IS). The API-4,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of ZFK and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with 10 mm ammonium acetate (pH 6.4):acetonitrile (20:80, v/v) on a Hypersil BDS C(18) column. The total chromatographic run time was 2.0 min and the elution of ZFK and IS occurred at approximately 1.11 and 1.58 min, respectively. The MS/MS ion transitions monitored were 574.2 --> 462.1 for ZFK and 313.3 --> 118.1 for IS. The method was proved to be accurate and precise at a linearity range of 0.15-600 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 0.15 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 20 mg ZFK tablet.  相似文献   

6.
A rapid, sensitive, and simple ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) method for the determination of udenafil and its active metabolite, DA-8164, in human plasma and urine using sildenafil as an internal standard (IS) was developed and validated. Udenafil, DA-8164 and IS from a 100 microL aliquot of biological samples were extracted by protein precipitation using acetonitrile. Chromatographic separation was carried on an Acquity UPLC BEH C(18) column (50 x 2.1 mm, i.d., 1.7 microm) with an isocratic mobile phase consisting of acetonitrile and containing 0.1% formic acid (75:25, v/v) at flow rate of 0.4 mL/min, and total run time was within 1 min. Detection and quantification was performed by the mass spectrometer using multiple reaction-monitoring mode at m/z 517 --> 283 for udenafil, m/z 406 --> 364 for DA-8164 and m/z 475 --> 100 for IS. The assay was linear over a concentration range of 1-600 ng/mL with a lower limit of quantification of 1 ng/mL in both human plasma and urine. The coefficient of variation of this assay precision was less than 13.7%, and the accuracy exceeded 92.0%. This method was successfully applied for pharmacokinetic study after oral administration of udenafil 100 mg to healthy Korean male volunteers.  相似文献   

7.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of ziprasidone (ZIP) in human plasma was developed. ZIP and N-methyl ziprasidone as internal standard (IS) were extracted from alkalinized plasma using tert- butyl methyl ether. Separation was performed isocratically on a C8 column with 90% acetonitrile containing 2 mmol/L ammonium acetate as a mobile phase with a total run time of 2.5 min. MS/MS transitions of m/z 413 --> 194 and m/z 427 --> 177 of the analyte and internal standard were used for quantification. Confirmatory ions of m/z 413 --> 177 and m/z 427 --> 180 were collected as well. The calibration curve based on peak-area ratio was linear up to at least 200 ng/mL with a detection limit of 0.1 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 5%. The method was successfully applied to the analysis of ZIP in spiked human plasma.  相似文献   

8.
Hu W  Xu Y  Liu F  Liu A  Guo Q 《Biomedical chromatography : BMC》2008,22(10):1108-1114
A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers.  相似文献   

9.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of torcetrapib (TTB) with 100 microL hamster/dog plasma using DRL-16126 as an internal standard (IS). The API-4000 Q Trap LC-MS/MS was operated under multiple-reaction monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of TTB and IS from plasma with acetonitrile, which yielded consistent recoveries of 65.73 and 94.01% for TTB and 79.68 and 90.70% for IS in hamster and dog plasma, respectively. The total chromatographic run time was 3.0 min and the elution of TTB and IS occurred at approximately 2.25 and 2.20 min, respectively. The resolution of peaks was achieved with 0.01 m ammonium acetate:acetonitrile (15:85, v/v) at a flow rate of 0.40 mL/min on an Inertsil ODS-3 column. The method was proved to be accurate and precise at linearity range of 1.00-200 ng/mL with a correlation coefficient (r) of > or = 0.993. The method was rugged with 1.00 ng/mL as the lower limit of quantitation. TTB was stable in the battery of stability studies. The application of the assay to preclinical pharmacokinetic studies confirmed the utility of the assay to derive hamster/dog pharmacokinetic parameters.  相似文献   

10.
A sensitive validated liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for gabapentin (GB) in human plasma has been developed and applied to pharmacokinetic (PK) and bioequivalence (BE) studies in human. In a randomized crossover design with a 1-week period, each subject received a 300 mg GB capsule. The procedure involves a simple protein precipitation with acetonitrile and separated by LC with a Gemini C(18) column using acetonitrile-10 mm ammonium acetate (20:80, v/v, pH 3.2) as mobile phase. The GB and internal standard [(S)-(+)-alpha-aminocyclohexanepropionic acid hydrate] were analyzed using an LC-API 2000 MS/MS in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 172.0 --> 154.0 and m/z 172.0 --> 126.0 for GB and IS, respectively. The assay exhibited good linearity over a working range of 20-5000 ng/mL for GB in human plasma with a lower limit of quantitation of 20 ng/mL. No endogenous compounds were found to interfere with the analysis. The accuracy and precision were shown for concentrations over the standard ranges. This method was successfully applied for the PK and BE studies by analysis of blood samples taken up to 36 h after an oral dose of 300 mg of GB in 24 healthy volunteers.  相似文献   

11.
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel.  相似文献   

12.
A rapid, simple and validated liquid chromatography coupled to tandem mass spectrometric method (LC-MS/MS) for topiramate analysis in human plasma has been applied to pharmacokinetic and bioequivalence studies in 24 healthy male Korean volunteers. The procedure involves a simple liquid extraction of topiramate and prednisone (internal standard) with acetonitrile and separation by HPLC equipped with a Capcell Pak C18 column using acetonitrile-0.1% triethylamine (80:20, v/v) as a mobile phase. Detection was carried out on an API 2000 MS system by multiple reactions monitoring mode. The ionization was optimized using ESI(-) and selectivity was achieved by MS/MS analysis, m/z 338.0 --> 77.5 and m/z 357.1 --> 327.2 for topiramate and prednisone, respectively. The method had a total run time of 2.5 min and showed good linearity over a working range of 20-5000 ng/mL in human plasma with a lower limit of quantification of 20 ng/mL. No metabolic compounds were found to interfere with the analysis. The inter-day and intra-day accuracy were in the ranges of 99.24-116.63 and 93.45-108.68%, respectively, and inter-day and intra-day precisions were below 6.24 and 5.25%, respectively. This method was successfully applied for pharmacokinetic and bioequivalence studies by analysis of blood samples taken up to 96 h after an oral administration of 100 mg of topiramate in 24 healthy Korean volunteers.  相似文献   

13.
A sensitive and specific LC–MS/MS assay for determination of β ‐eudesmol in rat plasma was developed and validated. After liquid–liquid extraction with ethyl ether , the analyte and IS were separated on a Capcell Pak C18 column (50 × 2.0 mm, 5 μm) by isocratic elution with acetonitrile—water–formic acid (77.5:22.5:0.1, v /v/v) as the mobile phase at a flow rate of 0.4 mL/min. An ESI source was applied and operated in positive ion mode; a selected reaction monitoring scan was used for quantification by monitoring the precursor–product ion transitions of m/z 245.1 → 163.1 for β ‐eudesmol and m/z 273.4 → 81.2 for IS. Good linearity was observed in the concentration range of 3–900 ng/mL for β ‐eudesmol in rat plasma. Intra‐ and inter‐day precision and accuracy were both within ±14.3%. This method was applied for pharmacokinetic studies after intravenous bolus of 2.0 mg/kg or intragastric administration of 50 mg/kg β ‐eudesmol in rats.  相似文献   

14.
This study aims to develop and validate a simple and sensitive liquid chromatography with tandem mass spectrometry (LC–MS/MS) method for investigating the pharmacokinetic characteristics of bavachalcone. Liquid–liquid extraction was used to prepare plasma sample. Chromatographic separation of bavachalcone and IS was achieved using a Venusil ASB C18 (2.1 × 50 mm, 5 μm) column with a mobile phase of methanol (A)–water (B) (70:30, v /v). The detection and quantification of analytes was performed in selected‐reaction monitoring mode using precursor → product ion combinations of m/z 323.1 → 203.2 for bavachalcone, and m/z 373.0 → 179.0 for IS. Linear calibration plots were achieved in the range of 1–1000 ng/mL for bavachalcone (r 2 > 0.99) in rat plasma. The recovery of bavachalcone ranged from 84.1 to 87.0%. The method was precise, accurate and reliable. It was fully validated and successfully applied to pharmacokinetic study of bavachalcone.  相似文献   

15.
黄晓兰  吴惠勤  黄芳  林晓珊  朱志鑫 《色谱》2009,27(3):279-282
采用电喷雾质谱(ESI/MS)技术建立了脂肪醇聚氧乙烯醚硫酸钠(AES)的烷基碳链分布、乙氧基分布及平均EO数、平均相对分子质量的测定方法;采用液相色谱-电喷雾质谱(LC-ESI/MS)测定了AES中的游离十二烷基硫酸钠(SDS)的含量。将本方法应用于实际样品的测定,并与核磁共振法测得的平均EO数进行比较,二者的测定结果相当吻合,从而验证了本法的可靠性。  相似文献   

16.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of doxofylline (DFL) with 300 microL human serum using imipramine as the internal standard (IS). The API-3,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved direct precipitation of DFL and IS from human serum with acetonitrile. The resolution of peaks was achieved with formic acid (pH 2.5): acetonitrile (10:90, v/v) on an Amazon C(18) column. The total chromatographic run time was 3.0 min and the elution of DFL and IS occurred at approximately 1.46 and 2.15 min, respectively. The MS/MS ion transitions monitored were 267.5 --> 181.1 for DFL and 281.1 --> 86.2 for IS. The method was proved to be accurate and precise at linearity range of 1.00-5,000 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 1.00 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of DFL tablet.  相似文献   

17.
A rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method has been developed to determine 1, 2-[bis(1,2-benzisoselenazolone-3(2H)-ketone)]-ethane (BBSKE), a novel antineoplastic agent, in rat plasma. The analytes were separated on a C18 column with a mobile phase of methanol-water (75:25, v/v) and detected using a triple-quadrupole mass spectrometer in positive mode with the selective reaction monitoring. The characteristic ion dissociation transitions were m/z 603.0 --> 448.9 for derivatized BBSKE and m/z 631.0 --> 476.8 for derivatized internal standard. The assay was linear over a range of 1-1000 ng/mL with a lower limit of quantification of 1 ng/mL. Intra- and inter-day precisions were less than 9.6 and 5.0%, respectively, and the accuracy ranged from -5.2 to 4.0%. The validated method was successfully applied to the characterization of pharmacokinetic profile of BBSKE after oral administration in rats. Cop  相似文献   

18.
Guo N  Hu Z  Fan X  Zheng J  Zhang D  Xu T  Yu T  Wang Y  Li H 《Molecules (Basel, Switzerland)》2012,17(4):4733-4754
Salidroside and its aglycone p-tyrosol are two major phenols in the genus Rhodiola and have been confirmed to possess various pharmacological properties. In our present study, p-tyrosol was identified as the deglycosylation metabolite of salidroside after intravenous (i.v.) administration to rats at a dose of 50 mg/kg, but was not detectable after intragastric gavage (i.g.) administration through HPLC-photodiode array detection (PDA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Next, an accurate and precise LC-MS/MS method was developed to quantitatively determine salidroside and p-tyrosol in rat plasma samples. Samples were analyzed by LC-MS/MS on a reverse-phase xTerra MS C18 column which was equilibrated and eluted with an isocratic mixture of acetonitrile-water (1:9, v/v) at a flow rate of 0.3 mL/min. The analytes were monitored by multiple reaction monitoring (MRM) under the negative electrospray ionization mode. The precursor/product transitions (m/z) were 299.0 → 118.8 for salidroside, 137.0 → 118.9 for p-tyrosol and 150.1 → 106.9 for the internal standard (IS), paracetamol, respectively. The calibration curve was linear over the concentration ranges of 50-2,000 ng/mL for salidroside and 20-200 ng/mL for p-tyrosol. The inter- and intra-day accuracy and precision were within ± 15%. The method has been successfully applied to the pharmacokinetic study and the oral bioavailability was calculated.  相似文献   

19.
A high-throughput bioanalytical method for simultaneous quantitation of pravastatin and its metabolite (M1) in human serum was developed and validated using on-line extraction following liquid chromatography tandem mass spectrometry (LC-MS/MS). The on-line extraction was accomplished by the direct injection of a 50 microL serum sample, mixed 4:1 with an aqueous internal standard solution, into one of the extraction columns with aqueous 1 mm formic acid at flow rate of 3 mL/min. The separation and analysis were achieved by back-eluting the analytes from the extraction column and the analytical column to the mass spectrometer with an isocratic mobile phase consisting of 62% aqueous 1 mm formic acid and 38% acetonitrile at a flow rate of 0.8 mL/min. The second extraction column was being equilibrated while the first column was being used for analysis, and vice versa. The standard curve range was 0.500-100 ng/mL for pravastatin and M1. The lower limit of quantitation, 0.500 ng/mL for all the analytes, was achieved when 50 microL of human serum was used. The intra- and inter-day precisions were within 7.4%, and the accuracy was between 95 and 103%. The on-line extraction was finished in 0.5 min and total analysis time was 2.5 min per sample.  相似文献   

20.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 microL human plasma using memantine as an internal standard (IS). The API-4000 was operated under multiple-reaction monitoring mode (MRM) using the electrospray ionization technique. Solid-phase extraction was used to extract PPX and IS from human plasma. The resolution of peaks was achieved with 0.01 m ammonium acetate buffer (pH 4.4):acetonitrile (30:70, v/v) on a Discovery CN column. The total chromatographic run time was 3.0 min and the elution of PPX and IS occurred at approximately 2.32 and 2.52, respectively. The MS/MS ion transitions monitored were 212.10 --> 153.10 for PPX and 180.20 --> 107.30 for IS. The method was proved to be accurate and precise at linearity range of 20-3540 pg/mL with a correlation coefficient (r) of > or =0.999. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 0.25 mg PPX tablet.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号