首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
The layout of radio-frequency received coils is related to signal-to-noise ratio (SNR) in magnetic resonance imaging (MRI). In this paper, different structures of four-channel received coil arrays for vertical-field MRI are constructed and optimized by establishing the relationship between coil geometry and SNR to achieve a high SNR and a uniform SNR distribution in the region of interest (ROI). Then, the SNR distributions of three optimized configurations, including rectangular loops, non-definite shape surface coils, and solenoid loops as the main unit, are simulated and compared. The four-channel coil of solenoid loops as the main unit has been found to have the best performance with the highest mean SNR in the ROI when imaging without acceleration. In addition, g-factor and 2D SENSE SNR in yoz-plane are simply analyzed, which show a sharp decrease in SNR for all the coils. Finally, all the coils are manufactured and operated at a 0.5 T permanent magnet MRI system with phantom and joint imaging experiments. Using pixel-by-pixel manner to evaluate SNR map, the experimental results are consistent with the simulation results, while parallel imaging experiment results show that the major consideration in low field MRI is the improvement of SNR value and uniformity rather than that of the imaging speed. As different constructions of four-channel received coils are investigated, we have found the most effective configuration with high and uniform SNR for vertical-field MRI.  相似文献   

2.
The purpose of this study was to analyse the relationship between the radio frequency (RF) coil performance and conductor surface shape for ultra-high field (UHF) magnetic resonance imaging. Twelve different leg-shaped quadrature birdcage coils were modeled and built, e.g., 4 mm-width-leg conventional birdcage coil, 7 mm-width-leg conventional birdcage, 10 mm-width-leg conventional birdcage coil, 13 mm-width-leg conventional birdcage coil, inside arc-shape-leg birdcage coil, outward arc-shape-leg birdcage coil, inside right angle-shape-leg birdcage coil, outward right angle-shape-leg birdcage coil, vertical 4 mm-width-leg vertical birdcage, 6 mm-width-leg vertical birdcage, 8 mm-width-leg vertical birdcage and 10 mm-width-leg vertical birdcage. Studies were carried out in both electromagnetic simulations with finite element method as well as in vitro saline phantom experiments at 9.4 T. Both the results of simulation and experiment showed that conventional birdcage coil produces the highest signal-to-noise ratio (SNR) while the vertical birdcage coil produces the most homogeneous RF magnetic (B 1) field at UHF. For conventional birdcage coils, as well as the vertical birdcage coils, only the proper width of legs results in the best performance (e.g., B 1 homogeneous and SNR). For vertical birdcage coils, the wider the leg size, the higher RF magnetic (B 1) field intensity distribution.  相似文献   

3.
Copper foil has been widely employed in conventional radio frequency (RF) birdcage coils for magnetic resonance imaging (MRI). However, for ultrahigh-field (UHF) MRI, current density distribution on the copper foil is concentrated on the surface and the edge due to proximity effect. This increases the effective resistance and distorts the circumferential sinusoidal current distribution on the birdcage coils, resulting in low signal-to-noise ratio (SNR) and inhomogeneous distribution of RF magnetic (B1) field. In this context, multiple parallel round wires were proposed as legs of a birdcage coil to optimize current density distribution and to improve the SNR and the B1 field homogeneity. The design was compared with three conventional birdcage coils with different width flat strip surface legs for a 9.4 T (T) MRI system, e.g., narrow-leg birdcage coil (NL), medium-leg birdcage coil (ML), broad-leg birdcage coil (BL) and the multiple parallel round wire-leg birdcage coil (WL). Studies were carried out in in vitro saline phantom as well as in vivo mouse brain. WL showed higher coil quality factor Q and more homogeneous B1 field distribution compared to the other three conventional birdcage coils. Furthermore, WL showed 12, 10 and 13% SNR increase, respectively, compared to NL, ML and BL. It was proposed that conductor’s shape optimization could be an effective approach to improve RF coil performance for UHF MRI.  相似文献   

4.
Applications of low-field magnetic resonance imaging (MRI) systems (<0.3 T) are limited due to the signal-to-noise ratio (SNR) being lower than that provided by systems based on superconductive magnets (≥1.5 T). Therefore, the design of radiofrequency (RF) coils for low-field MRI requires careful consideration as significant gains in SNR can be achieved with the proper design of the RF coil. This article describes an analytical method for the optimization of solenoidal coils. Coil and sample losses are analyzed to provide maximum SNR and optimum B1 field homogeneity. The calculations are performed for solenoidal coils optimized for the human head at 0.2 T, but the method could also be applied to any solenoidal coil for imaging other anatomical regions at low field. Several coils were constructed to compare experimental and theoretical results. A head magnetic resonance image obtained at 0.2 T with the optimum design is presented.  相似文献   

5.

Purpose

To investigate intracranial microvascular images with transceiver radio-frequency (RF) coils at ultra-high field 7 T magnetic resonance imaging (MRI).

Materials and methods

We designed several types of RF coils for the study of 7 T magnetic resonance angiography and analyzed quantitatively each coil's performance in terms of the signal-to-noise ratio (SNR) profiles to evaluate the usefulness of RF coils for microvascular imaging applications. We also obtained the microvascular images with different resolutions and parallel imaging technique.

Results

The overlapped 6-channel (ch) transceiver coil exhibited the highest performance for angiographic imaging. Although other multi-channel coils, such as 4- or 8-ch, were also suitable for fast imaging, these coils performed poorly in homogeneity or SNR for angiographic imaging. Furthermore, the 8-ch coil was poor in SNR at the center of the brain, while it had the highest SNR at the periphery.

Conclusion

The present study has demonstrated that the overlapped 6-ch coil with large-size loop coils provided the best performance for microvascular imaging or angiography with the ultra-high-field 7 T MRI, mainly because of its long penetration depth together with high SNR.  相似文献   

6.
在临床磁共振成像(MRI)应用中,射频线圈的设计是非常关键的,针对不同的应用目的,合适的线圈能获得质量更好的图像. 有的应用需要线圈提供均匀性较好的射频场,而有的应用则需要线圈在特定区域内提供高的信噪比(SNR). 但是线圈很难同时得到好的射频场(B1场)、空间均匀性和高的SNR,需要根据实际应用情况进行折衷设计. 针对MRI在脑外科手术中的应用特点,设计并制作了一种新颖的、适用于脑外科手术的MRI接收和发射共用射频线圈. 该线圈采用可分拆式结构,在脑外科手术支架上可以进行反复组装和拆卸,减少了MRI对医生手术的影响. 仿真结果和人体成像实验表明,该线圈能产生均匀的射频场、有较高的SNR和较大的成像范围,满足脑外科手术的需要.  相似文献   

7.
Magnetic resonance imaging (MRI) technique is widely used to capture the images of the liquid items inside the human body. The radio-frequency (RF) coil is one of the important modules present inside an MRI system, which plays a major role in image quality. In this work, a microstrip-based high-pass RF birdcage coil is proposed for 1.5 T MRI. The cylindrical-shaped birdcage coil consists of 12 microstrip radiating elements and tuning capacitors to achieve a resonance at 63.85 MHz. The coil is made up of 10 mm polytetrafluoroethylene substrate coated by a conducting transmission line of desired length and width. A finite difference time domain simulation is carried out to analyze the return loss (S11), magnetic field homogeneity and Specific Absorption Rate (SAR) parameters of the RF coil. The SAR values of the proposed microstrip-based 1.5 T birdcage coil was compared with 3 T RF birdcage coil. The simulation results indicate the proposed birdcage coil structure gives optimal values of S11, magnetic field homogeneity and SAR.  相似文献   

8.
A 16-channel transceiver radiofrequency (RF) array using Helmholtz coils was designed to improve the RF transmission |B 1 + |-field homogeneity for human brain magnetic resonance imaging (MRI) at 7 T. A numerical simulation of the proposed Helmholtz transceiver array was performed using the finite-difference time-domain method—the subset of the finite-element method simulation. The simulation results of proposed 16-channel Helmholtz transceiver array were compared with the generally used rectangular transceiver array in term of their |B 1 + |-field and specific absorption rate (SAR). The simulation of each single element in 16-channel Helmholtz and rectangular transceiver arrays was compared using water phantom in term of their magnetic flux |B 1| homogeneity for the full width at half maximum. From the simulation results, the proposed 16-channel Helmholtz transceiver array configuration offers superior |B 1 + |-field homogeneity and low SAR at 7 T. These modifications to the coil geometries of the transceiver array coil could be applied to a 7-T MRI, and also extended to increase the homogenous coverage on |B 1 + |field with low SAR.  相似文献   

9.
Quantitative magnetic resonance imaging (MRI) studies of small samples such as a single cell or cell clusters require application of radiofrequency (RF) coils that provide homogenous B1 field distribution and high signal-to-noise ratio (SNR).We present a novel design of an MRI RF volume microcoil based on a microstrip structure. The coil consists of two parallel microstrip elements conducting RF currents in the opposite directions, thus creating homogenous RF field within the space between the microstrips. The construction of the microcoil is simple, efficient and cost-effective.Theoretical calculations and finite element method simulations were used to optimize the coil geometry to achieve optimal B1 and SNR distributions within the sample and predict parameters of the coil. The theoretical calculations were confirmed with MR images of a 1-mm-diameter capillary and a plant obtained with the double microstrip RF microcoil at 11.7 T. The in-plane resolution of MR images was 24 μm×24 μm.  相似文献   

10.
The monopole coil and loop coil have orthogonal radiofrequency (RF) fields and thus are intrinsically decoupled electromagnetically if they are laid out appropriately. In this study, we proposed a hybrid monopole/loop technique which could combine the advantages of both loop arrays and monopole arrays. To investigate this technique, a hybrid RF coil array containing four monopole channels and four loop channels was developed for human head magnetic resonance (MR) imaging at 7 T. In vivo MR imaging and g-factor results using monopole-only channels, loop-only channels and all channels of the hybrid array were acquired and evaluated. Compared with the monopole-only and loop-only channels, the proposed hybrid array has the higher signal-to-noise ratio (SNR) and better parallel imaging performance. Sufficient electromagnetic decoupling and diverse RF magnetic field (B1) distributions of monopole channels and loop channels may contribute to this performance improvement. From experimental results, the hybrid monopole/loop array has low g-factor and excellent SNR at both periphery and center of the brain, which is valuable for human head imaging at ultrahigh fields.  相似文献   

11.
The conventional magnetic resonance imaging(MRI) equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure. In order to realize the mobile MRI, this study focuses on the design of gradient coil of unilateral magnet. The unilateral MRI system is used to image the local area above the magnet. The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils, because the region of interest(ROI) and the wiring area of the unilateral magnet are both cylindrical side arc surfaces. Therefore, the equivalent magnetic dipole method is used to design the gradient coil, and the algorithm is improved for the special case of the wiring area and the ROI, so the X and Y gradient coils are designed.Finally, a flexible printed circuit board(PCB) is used to fabricate the gradient coil, and the magnetic field distribution of the ROI is measured by a Gauss meter, and the measured results match with the simulation results. The gradient linearities of x and y coils are 2.82% and 3.56%, respectively, less than 5% of the commercial gradient coil requirement.  相似文献   

12.
In clinical magnetic resonance imaging(MRI),the design of the radiofrequency(RF) coil is very important.For certain applications,the appropriate coil can produce an improved image quality.However,it is difficult to achieve a uniform B1 field and a high signal-to-noise ratio(SNR) simultaneously.In this article,we design an interventional transmitter-and-receiver RF coil for cerebral surgery.This coil adopts a disassembly structure that can be assembled and disassembled repeatedly on the cerebral surgery gantry to reduce the amount of interference from the MRI during surgery.The simulation results and the imaging experiments demonstrate that this coil can produce a uniform RF field,a high SNR,and a large imaging range to meet the requirements of the cerebral surgery.  相似文献   

13.
We describe the design and operation of an open-access, very-low-field, magnetic resonance imaging (MRI) system for in vivo hyperpolarized 3He imaging of the human lungs. This system permits the study of lung function in both horizontal and upright postures, a capability with important implications in pulmonary physiology and clinical medicine, including asthma and obesity. The imager uses a bi-planar B0 coil design that produces an optimized 65 G (6.5 mT) magnetic field for 3He MRI at 210 kHz. Three sets of bi-planar coils produce the x, y, and z magnetic field gradients while providing a 79-cm inter-coil gap for the imaging subject. We use solenoidal Q-spoiled RF coils for operation at low frequencies, and are able to exploit insignificant sample loading to allow for pre-tuning/matching schemes and for accurate pre-calibration of flip angles. We obtain sufficient SNR to acquire 2D 3He images with up to 2.8 mm resolution, and present initial 2D and 3D 3He images of human lungs in both supine and upright orientations. 1H MRI can also be performed for diagnostic and calibration reasons.  相似文献   

14.
介绍了一种用于开放式MRI系统的射频发射线圈. 此发射线圈为上下2个相同的线圈,分别安装在磁体的2极,两线圈采用非对称的正交方式放置. 线圈为矩形螺线管结构,通过电磁场数值计算的方法对线圈的匝间距进行了优化,使线圈在300 mm的球形区域内达到偏差不超过3 dB的均匀性要求. 根据优化结果制作了一套用于0.23 T开放式MRI系统的发射线圈,并对线圈的均匀性及射频发射的效率进行了测试. 测试结果表明,线圈具有较高的发射效率和较好的均匀性,由此验证了设计方案的可行性.  相似文献   

15.
The signal-to-noise ratio (SNR) performance and practicality issues of a four-element phased-array coil and an implantable coil system were compared for rat spinal cord magnetic resonance imaging (MRI) at 7 T. MRI scans of the rat spinal cord at T10 were acquired from eight rats over a 3 week period using both coil systems, with and without laminectomy. The results demonstrate that both the phased array and the implantable coil systems are feasible options for rat spinal cord imaging at 7 T, with both systems providing adequate SNR for 100-mum spatial resolution at reasonable imaging times. The implantable coils provided significantly higher SNR, as compared to the phased array (average SNR gain of 5.3x between the laminectomy groups and 2.5x between the nonlaminectomy groups). The implantable coil system should be used if maximal SNR is critical, whereas the phased array is a good choice for its ease of use and lesser invasiveness.  相似文献   

16.
Non-human primates (NHPs) are vital models for neuroscience research. These animals have been widely used in behavioral, electrophysiological, molecular, and more recently, multimodal neuroimaging and neuro-engineering studies. Several RF coil arrays have been designed for functional, high-resolution brain magnetic resonance imaging (MRI), but few have been designed to accommodate multimodal devices. In the present study, a 16-channel array coil was constructed for brain imaging of macaques at 3 Tesla (3 T). To construct this coil, a close-fitting helmet-shaped form was designed to host 16 coil loops for whole-brain coverage. This assembly is mountable onto stereotaxic head frame bars, and the coil functions while the monkey is in the sphinx position with a clear line of vision of stimuli presented from outside of the MRI system. In addition, 4 openings were allocated in the coil housing, allowing multimodal devices to directly access visual cortical regions such as V1-V4 and MT. Coil performance was evaluated in an anesthetized macaque by quantifying and comparing signal-to-noise ratios (SNRs), noise correlations, and g-factor maps to a vendor-supplied human pediatric coil frequently used for NHP MRI. The result from in vivo experiments showed that the NHP coil was well-decoupled, had higher SNRs in cortical regions, and improved data acquisition acceleration capability compared with a vendor-supplied human pediatric coil that has been frequently used in macaque MRI studies. Furthermore, whole-brain anatomic imaging, diffusion tensor imaging and functional brain imaging have also been conducted: the details of brain anatomical structure, such as cerebellum and brainstem, can be clearly visualized in T2-SPACE images; b0 SNR calculated from b0 maps was higher than the human pediatric coil in all regions of interest (ROIs); the time-course SNR (tSNR) map calculated for GRE-EPI images demonstrates that the presented coil can be used for high-resolution functional imaging at 3 T.  相似文献   

17.
Parallel magnetic resonance imaging (pMRI) and compressed sensing (CS) have been recently used to accelerate data acquisition process in MRI. Matrix inversion (for rectangular matrices) is required to reconstruct images from the acquired under-sampled data in various pMRI algorithms (e.g., SENSE, GRAPPA) and CS. Singular value decomposition (SVD) provides a mechanism to accurately estimate pseudo-inverse of a rectangular matrix. This work proposes the use of Jacobi SVD algorithm to reconstruct MR images from the acquired under-sampled data both in pMRI and in CS. The use of Jacobi SVD algorithm is proposed in advance MRI reconstruction algorithms, including SENSE, GRAPPA, and low-rank matrix estimation in L + S model for matrix inversion and estimation of singular values. Experiments are performed on 1.5T human head MRI data and 3T cardiac perfusion MRI data for different acceleration factors. The reconstructed images are analyzed using artifact power and central line profiles. The results show that the Jacobi SVD algorithm successfully reconstructs the images in SENSE, GRAPPA, and L + S algorithms. The benefit of using Jacobi SVD algorithm for MRI image reconstruction is its suitability for parallel computation on GPUs, which may be a great help in reducing the image reconstruction time.  相似文献   

18.
Typically 31P in vivo magnetic resonance spectroscopic studies are limited by SNR considerations. Although phased arrays can improve the SNR; to date 31P phased arrays for high-field systems have not been combined with 31P volume transmit coils. Additionally, to provide anatomical reference for the 31P studies, without removal of the coil or patient from the magnet, double-tuning (31P/1H) of the volume coil is required. In this work we describe a series of methods for active detuning and decoupling enabling use of phased arrays with double-tuned volume coils. To demonstrate these principles we have built and characterized an actively detuneable 31P/1H TEM volume transmit/four-channel 31P phased array for 4 T magnetic resonance spectroscopic imaging (MRSI) of the human brain. The coil can be used either in volume-transmit/array-receive mode or in TEM transmit/receive mode with the array detuned. Threefold SNR improvement was obtained at the periphery of the brain using the phased array as compared to the volume coil.  相似文献   

19.
Sodium magnetic resonance (MR) imaging is a promising technique for detecting changes of proteoglycan (PG) content in cartilage associated with knee osteoarthritis. Despite its potential clinical benefit, sodium MR imaging in vivo is challenging because of intrinsically low sodium concentration and low MR signal sensitivity. Some of the challenges in sodium MR imaging may be eliminated by the use of a high-sensitivity radiofrequency (RF) coil, specifically, a dual-tuned (DT) proton/sodium RF coil which facilitates the co-registration of sodium and proton MR images and the evaluation of both physiochemical and structural properties of knee cartilage. Nevertheless, implementation of a DT proton/sodium RF coil is technically difficult because of the coupling effect between the coil elements (particularly at high field) and the required compact design with improved coil sensitivity. In this study, we applied a multitransceiver RF coil design to develop a DT proton/sodium coil for knee cartilage imaging at 3 T. With the new design, the size of the coil was minimized, and a high signal-to-noise ratio (SNR) was achieved. DT coil exhibited high levels of reflection S11 (~-21 dB) and transmission coefficient S12 (~-19 dB) for both the proton and sodium coils. High SNR (range 27-38) and contrast-to-noise ratio (CNR) (range 15-21) were achieved in sodium MR imaging of knee cartilage in vivo at 3-mm(3) isotropic resolution. This DT coil performance was comparable to that measured using a sodium-only birdcage coil (SNR of 28 and CNR of 20). Clinical evaluation of the DT coil on four normal subjects demonstrated a consistent acquisition of high-resolution proton images and measurement of relative sodium concentrations of knee cartilages without repositioning of the subjects during the same MR scanning session.  相似文献   

20.
A surface coil for MRI was designed and built based on the principles of the petal resonator proposed by Mansfield [J Phys D Appl Phys 21 (1988) 1643]. This resonator coil design was named the petal resonator surface (PERES) coil and is composed of an eight-petal coil array and a central circular coil. A minimum separation of three times the petal coil radius is necessary to significantly decrease the mutual inductance. An analytical function for the PERES Signal-to-noise ratio (SNR) is obtained based on the quasistatic method. Theoretical plots of SNR enhancement yielded 26% and 35% more SNR over the circular coil and phased-array coils. Imaging experiments were first performed using a spectroscopy phantom on a 1.5-T commercial imager. Subsequently, brain images of healthy volunteers were obtained. Clinical MR imager compatibility allows this resonator coil to be used with conventional pulse sequences and imaging protocols. This coil design offers a new alternative to existing surface coils because it significantly increases the SNR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号