首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe a DNA microarray system using a bipolar integrated circuit photodiode array (PDA) chip as a new platform for DNA analysis. The PDA chip comprises an 8 × 6 array of photodiodes each with a diameter of 600 μm. Each photodiode element acts both as a support for an immobilizing probe DNA and as a two-dimensional photodetector. The usefulness of the PDA microarray platform is demonstrated by the detection of high-risk subtypes of human papilloma virus (HPV). The polymerase chain reaction (PCR)-amplified biotinylated HPV target DNA was hybridized with the immobilized probe DNA on the photodiode surface, and the chip was incubated in an anti-biotin antibody-conjugated gold nanoparticle solution. The silver enhancement by the gold nanoparticles bound to the biotin of the HPV target DNA precipitates silver metal particles at the chip surfaces, which block light irradiated from above. The resulting drop in output voltage depends on the amount of target DNA present in the sample solution, which allows the specific detection and the quantitative analysis of the complementary target DNA. The PDA chip showed high relative signal ratios of HPV probe DNA hybridized with complementary target DNA, indicating an excellent capability in discriminating HPV subtypes. The detection limit for the HPV target DNA analysis improved from 1.2 nM to 30 pM by changing the silver development time from 5 to 10 min. Moreover, the enhanced silver development promoted by the gold nanoparticles could be applied to a broader range of target DNA concentration by controlling the silver development time. Figure An optical image of the PDA chip and target DNA detection through silver enhancement Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

2.
An electrochemical DNA biosensor for human papillomavirus (HPV) 16 detection has been developed. For this proposed biosensor, l-cysteine was first electrodeposited on the gold electrode surface to form l-cysteine film (CYSFILM). Subsequently, HPV16-specific probe was immobilized on the electrode surface with CYSFILM. Electrochemistry measurement was studied by differential pulse voltammetry method (DPV). The measurement was based on the reduction signals of methylene blue (MB) before and after hybridization either between probe and synthetic target or extracted DNA from clinical samples. The effect of probe concentration was analyzed and the best results were seen at 1000 nM. The hybridization detection presented high sensitivity and broad linear response to the synthetic-target concentration comprised between 18.75 nM and 250 nM as well as to a detection limit of 18.13 nM. The performance of this biosensor was also investigated by checking probe-modified electrode hybridization with extracted DNA from samples. The results showed that the biosensor was successfully developed and exhibited high sensitivity and satisfactory selectivity to HPV16. These results allow for the possibility of developing a new portable detection system for HPVs and for providing help in making an effective diagnosis in the early stages of infection.  相似文献   

3.
A detection system for a human papillomavirus (HPV) DNA chip based on the light scattering of aggregated silica nanoparticle probes is presented. In the assay, a target HPV DNA is sandwiched between the capture DNA immobilized on the chip and the probe DNA immobilized on the plain silica nanoparticle. The spot where the sandwich reaction occurs appears bright white and is readily distinguishable to the naked eye. Scanning electron microscopy images clearly show the aggregation of the silica nanoparticle probes. When three different sized (55 nm, 137 nm, 286 nm) plain silica nanoparticles were compared, probes of the larger silica nanoparticles showed a higher scattering intensity. Using 286-nm silica nanoparticles, the spots obtained with 200 pM of target DNA were visually detectable. The demonstrated capability to detect a disease related target DNA with direct visualization without using a complex detection instrument provides the prerequisite for the development of portable testing kits for genotyping.  相似文献   

4.
An electrochemical DNA detection method for the phosphinothricin acetyltransferase (PAT) gene sequence from the transgenetic plants was established by using a microplate hybridization assay with cadmium sulfide (CdS) nanoparticles as oligonucleotides label. The experiment included the following procedures. Firstly target PAT ssDNA sequences were immobilized on the polystyrene microplate by physical adsorption. Then CdS nanoparticle labeled oligonucleotide probes were added into the microplate and the hybridization reaction with target ssDNA sequences took place in the microplate. After washing the microplate for three times, certain amounts of HNO3 were added into the microplate to dissolve the CdS nanoparticles anchored on the hybrids and a solution containing Cd2+ ion was obtained. At last differential pulse anodic stripping voltammetry (DPASV) was used for the sensitive detection of released Cd2+ ion. Based on this principle a sensitive electrochemical method for the PAT gene sequences detection was established. The voltammetric currents of Cd2+ were in linear range with the target ssDNA concentration from 5.0 × 10− 13 to 1.0 × 10− 10 mol/L and the detection limit was estimated to be 8.9 × 10− 14 mol/L (3σ). The proposed method showed a good promise for the sensitive detection of specific gene sequences with good selectivity for the discrimination of the mismatched sequences.  相似文献   

5.
This paper describes a disposable indicator-free electrochemical DNA biosensor applied to the detection of apolipoprotein E (apoE) sequences in PCR samples. In the indicator-free assays, the duplex formation was detected by measuring the electrochemical signal of the guanine base of nucleic acids. The biosensor format involved the immobilisation of an inosine-modified (guanine-free) probe onto a screen-printed electrode (SPE) transducer and the detection of the duplex formation in connection with the square-wave voltammetric measurement of the oxidation peak of the guanine of the target sequence.The indicator-free scheme has been characterised using 23-mer oligonucleotides as model: parameters affecting the hybridisation assay such as probe immobilisation conditions, hybridisation time, use of hybridisation accelerators were examined and optimised.The analysis of PCR samples (244 bp DNA fragments, obtained by amplification of DNA extracted from human blood) required a further optimisation of the experimental procedure. In particular, a lower steric hyndrance of the probe modified surface was essential to allow an efficient hybridisation of the target DNA fragment. Negative controls have been performed using the PCR blank and amplicons unrelated to the immobilised probe. A 10 min hybridisation time allowed a full characterisation of each sample.  相似文献   

6.
A highly sensitive and label-free impedimetric biosensor is achieved based on an adjunct probe attached nearby the capture probe. In this work, the adjunct probe was co-assembled on the surface of gold electrode with the capture probe hybridized with the reporter probe, and then 6-mercapto-1-hexanol was employed to block the nonspecific binding sites. When target DNA was added, the adjunct probe functioned as a fixer to immobilize the element of reporter probe displaced by the target DNA sequences and made the reporter probe approach the electrode surface, leading to effective inhibition of charge transfer. The increase in charge transfer resistance is related to the quantity of the target DNA in a wide range. The linear range for target DNA with specific sequences was from 0.1 nM to 0.5 μM with a good linearity (R = 0.9988) and a low detection limit of 6.3 pM. This impedimetric biosensor has the advantages of simplicity, sensitivity, good selectivity, and large dynamic range.  相似文献   

7.
An electrochemical DNA genosensor constructed by using rough gold as electrode support is reported in this work. The electrode surface nanopatterning was accomplished by repetitive square-wave perturbing potential (RSWPP). A synthetic 25-mer DNA capture probe, modified at the 5′ end with a hexaalkylthiol, able to hybridize with a specific sequence of lacZ gene from the Enterobacteriaceae bacterial family was assembled to the rough gold surface. A 25 bases synthetic sequence fully complementary to the thiolated DNA capture probe and a 326 bases fragment of lacZ containing a fully matched sequence with the capture probe, which was amplified by a specific asymmetric polymerase chain reaction (aPCR), were employed as target sequences. The hybridization event was electrochemically monitored by using two different indicators, hexaammineruthenium (III) chloride showing an electrostatic DNA binding mode, and pentaamineruthenium-[3-(2-phenanthren-9-yl-vinyl)-pyridine] (in brief RuL) which binds to double stranded DNA (dsDNA) following an intercalative mechanism. After optimization of the different variables involved in the hybridization and detection reactions, detection limits of 5.30 pg μL−1 and 10 pg μL−1 were obtained for the 25-mer synthetic target DNA and the aPCR amplicon, respectively. A RSD value of 6% was obtained for measurements carried out with 3 different genosensors prepared in the same manner.  相似文献   

8.
Taking advantage of exonuclease III (Exo III)-assisted signal attenuation strategy and the protection of DNA from Exo III-mediated digestion by specific DNA–protein interaction, a colorimetric method is proposed in this paper for protein assay. Specifically, in the absence of target protein, Exo III-assisted signal attenuation can be achieved by digesting the report DNA in a complex formed by the hybridization of a report DNA and a probe DNA. Nevertheless, in the presence of target protein, the binding of the analyte to the probe DNA will inhibit the Exo III-assisted nucleotides cleavage, so that cyclic signal attenuation is blocked. Therefore, a bridge can be established between the concentration of target protein and the degree of the attenuation of the obtained signal, and the relationship can be shown by the surface plasmon changes caused by the report DNA-induced aggregation of DNA-modified gold nanoparticles (AuNPs). Our method can also have considerable sensitivity and selectivity, which has been demonstrated by the assay of human α-thrombin. Furthermore, by simply changing the sequence of the probe DNA, we can expand the application of our method to not only aptamer binding proteins but also DNA binding proteins, thus we have also used this method to analyze a specific serological marker for systemic lupus erythematosus (SLE) in this study. With a broad detection range of 1.3–133 nM and a detection limit of 0.61 nM (S/N = 3), it may hold great promise for clinical application.  相似文献   

9.
Exploring graphene oxide (GO), DNA hybridization detection usually relies on either GO decoration or DNA sequences labeling. The former endows GO with desired chemical, optical, and biological properties. The latter adopts labeled molecules to indicate hybridization. In the present work, we propose a simple, label-free DNA assay using undecorated GO directly as the sensing platform. GO is anchored on diazonium functionalized electrode through electrostatic attraction, hydrogen bonding or epoxy ring-opening. The π–π stacking interaction between hexagonal cells of GO and DNA base rings facilitates DNA immobilization. The adsorbed DNA sequence is specially designed with two parts, including immobilization sequence and probe sequence. In the absence of target, the two sequences lie nearly flat on GO platform. In the presence of target, probe hybridizes with it to form double helix DNA, which ‘stands’ on GO. While the immobilization sequence part remains ‘lying’ on GO surface. Hence, DNA hybridization induces GO interfacial property changes, including negative charge and conformational transition from ‘lying’ ssDNA to ‘standing’ dsDNA. These changes are monitored by electrochemical impedance spectroscopy and adopted as the analytical signal. This strategy eliminates the requirement for GO decoration or DNA labeling, representing a comparatively simple and effective way. Finally, the principle is applied to the detection of conserved sequence of the human immunodeficiency virus 1 pol gene fragment. The dynamic detection range is from 1.0 × 10−12 to 1.0 × 10−6 M with detection limit of 1.1 × 10−13 M with 3σ. And the sequences with double- or four-base mismatched are readily distinguishable. In addition, this strategy may hold great promise for potential applications from DNA biosensing to nanostructure framework construction based on the versatile DNA self-assembly.  相似文献   

10.
This study describes a simple and label-free electrochemical impedance spectroscopic (EIS) method for sequence-specific detection of DNA by using single-walled carbon nanotubes (SWNTs) as the support for probe DNA. SWNTs are confined onto gold electrodes with mixed self-assembly monolayers of thioethanol and cysteamine. Single-stranded DNA (ssDNA) probe is anchored onto the SWNT support through covalent binding between carboxyl groups at the nanotubes and amino groups at 5′ ends of ssDNA. Hybridization of target DNA with the anchored probe DNA greatly increases the interfacial electron-transfer resistance (Ret) at the double-stranded DNA (dsDNA)-modified electrodes for the redox couple of Fe(CN)63−/4−, which could be used for label-free and sequence-specific DNA detection. EIS results demonstrate that the utilization of SWNTs as the support for probe DNA substantially increases the surface loading of probe DNA onto electrode surface and thus remarkably lowers the detection limit for target DNA. Under the conditions employed here, Ret is linear with the concentration of target DNA within a concentration range from 1 to 10 pM with a detection limit down to 0.8 pM (S/N = 3). This study may offer a novel and label-free electrochemical approach to sensitive sequence-specific DNA detection.  相似文献   

11.
Na Zhou 《Talanta》2009,77(3):1021-183
A polyaniline nanofibers (PANnano)/carbon paste electrode (CPE) was prepared via dopping PANnano in the carbon paste. The nanogold (Aunano) and carbon nanotubes (CNT) composite nanoparticles were bound on the surface of the PANnano/CPE. The immobilization and hybridization of the DNA probe on the Aunano-CNT/PANnano films were investigated with differential pulse voltammetry (DPV) and cyclic voltammetry (CV) using methylene blue (MB) as indicator, and electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/4− as redox probe. The voltammetric peak currents of MB increased dramatically owing to the immobilization of the probe DNA on the Aunano-CNT/PANnano films, and then decreased obviously owing to the hybridization of the DNA probe with the complementary single-stranded DNA (cDNA). The electron transfer resistance (Ret) of the electrode surface increased after the immobilization of the probe DNA on the Aunano-CNT/PANnano films and rose further after the hybridization of the probe DNA. The remarkable difference between the Ret value at the DNA-immobilized electrode and that at the hybridized electrode could be used for the label-free EIS detection of the target DNA. The loading of the DNA probe on Aunano-CNT/PANnano films was greatly enhanced and the sensitivity for the target DNA detection was markedly improved. The sequence-specific DNA of phosphinothricin acetyltransferase (PAT) gene and the polymerase chain reaction (PCR) amplification of nopaline synthase (NOS) gene from transgenically modified beans were determined with this label-free EIS DNA detection method. The dynamic range for detecting the PAT gene sequence was from 1.0 × 10−12 mol/L to 1.0 × 10−6 mol/L with a detection limit of 5.6 × 10−13 mol/L.  相似文献   

12.
Shen H  Fang Q 《Talanta》2008,77(1):269-272
An improved microfluidic chip-based sequential-injection trapped-droplet array liquid-liquid extraction system with chemiluminescence (CL) detection was developed in this work. Two recess arrays were fabricated on both sides of the extraction channel to produce droplet arrays of organic extractant. A chip integrated monolithic probe was fabricated at the inlet of the extraction channel on the glass chip instead of the capillary probe connected to the microchannel, in order to improve the system stability and reliability. A slotted-vial array system coupled with the monolithic probe was used to sequentially introduce sample and different solvents and reagents into the extraction channel for extraction and CL detection. The performance of the system was demonstrated in the determination of Al3+ using Al3+-dihydroxyazobenzene (DHAB) and tributyl phosphate (TBP) extraction system. The operation conditions, including extraction time, concentration and flow rate of the CL reagents, were optimized. Within one analysis cycle of 12 min, an enrichment factor of 85 was obtained in the extraction stage with a sample consumption of 1.8 μL. The consumption of CL reagent, bis(2-carbopentyloxy-3,5,6-trichlorophenyl)oxalate (CPPO), was 120 nL/cycle. The detection limit of the system for Al3+ was 1.6 × 10−6 mol/L with a precision of 4.5% (R.S.D., n = 6).  相似文献   

13.
In combination with abasic site (AP site)-containing DNAs, potential use of a biotic fluorescence compound, Vitamin B2 (riboflavin), is demonstrated for the fluorescence detection of the thymine (T)-related single-nucleotide polymorphisms. Our method is based on construction of the AP site in DNA duplexes, which allows small ligands to bind to target nucleotides accompanied by fluorescence signaling: an AP site-containing probe DNA is hybridized with a target DNA so as to place the AP site toward a target nucleobase, by which hydrophobic microenvironments are provided for ligands to recognize target nucleotides through stacking and hydrogen-bonding interactions. In 10 mM sodium cacodylate buffer solutions (pH 7.0) containing 100 mM NaCl and 1.0 mM EDTA, Vitamin B2 is found to selectively bind to T (K11 = 1.8 × 106 M−1 at 5 °C) over other nucleobases, and this is accompanied by significant quenching of its fluorescence. While the sensing functions depend on the flanking sequences to the AP site, Vitamin B2 is applicable to the detection of T/C (cytosine), T/G (guanine) and T/A (adenine) mutation sequences of the CYP2A6 gene, where the flanking nucleobases are guanines in both positions (-GXG-, X = AP site).  相似文献   

14.
A novel sensitive electrochemical biosensor based on magnetite nanoparticle for monitoring DNA hybridization by using MWNT-COOH/ppy-modified glassy carbon electrode is described. In this new detection system, mercapatoacetic acid (RSH)-coated magnetite nanoparticles, capped with 5′-(NH2) oligonucleotide, is used as DNA probe to complex 29-base polynucleotide target (a piece of human porphobilinogen deaminase PBGD promoter from 170 to 142). Target sequence hybridized with the probe results in the decrease of the reduction peak current of daunomycin connected with probe. The response of non-complementary sequence was almost the same as the blank, and the response of three-base mismatched sequence within 29-base polynucleotide was obviously distinguished from complementary sequence, which can easily identify point mutation of DNA. The equation of calibration plot is ip (μA) = 0.8255 − 0.0847ctarget oligonucleotide × 1013 in the range of 6.9 × 10−14 to 8.6 × 10−13 mol/L, and correlation coefficient is 0.9974. The detective limit is 2.3 × 10−14 mol/L of target oligonucleotide. This device can be optimized for the detection of complex sequence.  相似文献   

15.
In this report a novel wash-free method for multiplexed DNA detection is demonstrated employing target specific probe pairs and switchable lanthanide luminescence technology on a solid-phase array. Four oligonucleotide capture probes, conjugated at 3′ to non-luminescent lanthanide ion carrier chelate, were immobilized as a small array on the bottom of a microtiter plate well onto which a mix of corresponding detection probes, conjugated at 5′ to a light absorbing antenna ligand, were added. In the presence of complementary target nucleic acid both the spotted capture probe and the liquid-phase detection probe hybridize adjacently on the target. Consequently the two non-luminescent label molecules self-assemble and form a luminescent mixed lanthanide chelate complex. Lanthanide luminescence is thereafter measured without a wash step from the spots by scanning in time-resolved mode. The homogeneous solid-phase array-based method resulted in quantitative detection of synthetic target oligonucleotides with 0.32 nM and 0.60 nM detection limits in a single target and multiplexed assay, respectively, corresponding to 3× SD of the background. Also qualitative detection of PCR-amplified target from Escherichia coli is described.  相似文献   

16.
We developed a method to graft a tripeptide (glutathione) onto 5-hydroxy-1,4-naphthoquinone, an electropolymerizable molecule. The resulting thin conducting polymer presents a well-defined and stable electroactivity in neutral buffered solution, due to the embedded quinone group, and is able to covalently graft amino-modified DNA probe strands. It is shown that the bioelectrode presents positive current change following DNA hybridization. This makes a “signal-on” direct electrochemical DNA sensor. The results were obtained with low target concentration (50 nM) and the selectivity is excellent as a single-mismatch sequence can be discriminated from the full-complementary target.  相似文献   

17.
Hybridization behavior of 24-meric and 105-meric single stranded DNAs derived from CDH4 gene related to cadherin cell-adhesive protein was tested with 24-meric DNA probe in a ferrocenylnaphthalene diimide (FND)-based hybridization assay. Hybridization efficiency in this system was also clarified using chronocoulometric (CC) measurement with Hexaammineruthenium (III) probe (RuHx). This is first example to calculate hybridization efficiency of PCR product with a DNA probe immobilized on the electrode. Although hybridization efficiency was really small for the PCR product as expected (20% for 105-meric PCR product), PCR products carrying aberrant methylation were discriminated from the wild one due to the electrochemical signal of FND. It was possible since FND possessed high preference for double stranded DNA, especially on the electrode. When applied to aberrant methylation detection for the fragment of CDH4 gene, this system can discriminate over 0.5 ng μL−1 sample DNA, which is superior to bisulfite sequencing or MSP and COBRA assays.  相似文献   

18.
Detection of polymerase chain reaction (PCR) products obtained from cultured greenhouse fungal pathogens, Botrytis cinerea and Didymella bryoniae has been achieved using a previously developed microfluidic microarray assembly (MMA) device. The flexible probe construction and rapid DNA detection resulted from the use of centrifugal pumping in the steps of probe introduction and sample delivery, respectively. The line arrays of the oligonucleotide probes were “printed” on a CD-like glass chip using a polydimethylsiloxane (PDMS) polymer plate with radial microfluidic channels, and the sample hybridizations were conducted within the spiral channels on the second plate. The experimental conditions of probe immobilization and sample hybridization were optimized, and both complementary oligonucleotides and PCR products were tested. We were able to achieve adequate fluorescent signals with a sample load as small as 0.5 nM (1 μL) for oligonucleotide samples; for PCR products, we achieved detection at the level of 3 ng.  相似文献   

19.
Herein, fluorescent DNA-templated gold/silver nanoclusters (DNA-Au/Ag NCs) are presented as a novel probe for sensitive detection of deoxyribonuclease I (DNase I). The procedure is based on quenching fluorescence of DNA-Au/Ag NCs by DNase I digestion of the DNA (5′-CCCTTAATCCCC-3′) template. This decrease in fluorescence intensity permitted sensitive detection of DNase I in a linear range of 0.013–60 μg mL−1, with a detection limit of 3 ng mL−1 at a signal-to-noise ratio of 3. Furthermore, the practicality of this probe for detection of DNase I in human serum and saliva samples was validated, demonstrating its advantages of simplicity, selectivity, sensitivity and low cost. Importantly, satisfactory agreement between results obtained by the fluorescent method described here and high performance liquid chromatography (HPLC) further confirmed the reliability and accuracy of this approach.  相似文献   

20.
We presented a new strategy for ultrasensitive detection of DNA sequences based on the novel detection probe which was labeled with Ag+ using metallothionein (MT) as a bridge. The assay relied on a sandwich-type DNA hybridization in which the DNA targets were first hybridized to the captured oligonucleotide probes immobilized on Fe3O4@Au composite magnetic nanoparticles (MNPs), and then the Ag+-modified detection probes were used to monitor the presence of the specific DNA targets. After being anchored on the hybrids, Ag+ was released down through acidic treatment and sensitively determined by a coupling flow injection–chemiluminescent reaction system (Ag+–Mn2+–K2S2O8–H3PO4–luminol) (FI–CL). The experiment results showed that the CL intensities increased linearly with the concentrations of DNA targets in the range from 10 to 500 pmol L−1 with a detection limit of 3.3 pmol L−1. The high sensitivity in this work may be ascribed to the high molar ratio of Ag+–MT, the sensitive determination of Ag+ by the coupling FI–CL reaction system and the perfect magnetic separation based on Fe3O4@Au composite MNPs. Moreover, the proposed strategy exhibited excellent selectivity against the mismatched DNA sequences and could be applied to real samples analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号