首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A label-free electrochemical DNA biosensor was developed through the attachment of polystyrene-g-soya oil-g-imidazole graft copolymer (PS-PSyIm) onto modified graphene oxide (GO) electrodeposited on glassy carbon electrode (GC). GC/GO electrode was initially functionalised via electrochemical reduction of 4-nitrobenzene diazonium salt, followed by the electrochemical reduction of NO2 to NH2. Subsequent to the electrochemical deposition of gold nanoparticles on modified surface, the attachment of the PS-PSyIm graft copolymer on the resulting electrode was achieved. The interaction of PS-PSyIm with DNA at the bare glassy carbon electrode was studied by cyclic voltammetry technique, and it was found that interaction predominantly takes place through intercalation mode. The selectivity of developed DNA biosensor was also explored by DPV on the basis of considering hybridisation event with non-complementary, one-base mismatched DNA and complementary target DNA sequence. Large decrease in the peak current was found upon the addition of complementary target DNA. The sensitivity of the developed DNA biosensor was also investigated, and detection limit was found to be 1.20 nmol L?1.  相似文献   

2.
An accurate and robust method for quantifying the levels of circulating tumor DNA (ctDNA) is vital if this potential biomarker is to be used for the early diagnosis of cancer. The analysis of ctDNA presents unique challenges because of its short half-life and ultralow abundance in early stage cancers. Here we develop an ultrasensitive electrochemical biosensor for rapid detection of ctDNA in whole blood. The sensing of ctDNA is based on hybridization on a network of probe DNA modified gold-coated magnetic nanoparticles (DNA-Au@MNPs). This DNA-Au@MNPs biosensor can selectively detect short- and long-strand DNA targets. It has a broad dynamic range (2 aM to 20 nM) for 22 nucleotide DNA target with an ultralow detection limit of 3.3 aM. For 101 nucleotide ctDNA target, a dynamic range from 200 aM to 20 nM was achieved with a detection limit of 5 fM. This DNA-Au@MNPs based sensor provides a promising method to achieve 20 min response time and minimally invasive cancer early diagnosis.

This study introduces a new electrochemical sensing strategy for the rapid detection of circulating tumor DNA (ctDNA) from whole blood in combination with a network of DNA-Au@MNPs with high sensitivity and excellent selectivity.  相似文献   

3.
We describe a DNA microarray system using a bipolar integrated circuit photodiode array (PDA) chip as a new platform for DNA analysis. The PDA chip comprises an 8 × 6 array of photodiodes each with a diameter of 600 μm. Each photodiode element acts both as a support for an immobilizing probe DNA and as a two-dimensional photodetector. The usefulness of the PDA microarray platform is demonstrated by the detection of high-risk subtypes of human papilloma virus (HPV). The polymerase chain reaction (PCR)-amplified biotinylated HPV target DNA was hybridized with the immobilized probe DNA on the photodiode surface, and the chip was incubated in an anti-biotin antibody-conjugated gold nanoparticle solution. The silver enhancement by the gold nanoparticles bound to the biotin of the HPV target DNA precipitates silver metal particles at the chip surfaces, which block light irradiated from above. The resulting drop in output voltage depends on the amount of target DNA present in the sample solution, which allows the specific detection and the quantitative analysis of the complementary target DNA. The PDA chip showed high relative signal ratios of HPV probe DNA hybridized with complementary target DNA, indicating an excellent capability in discriminating HPV subtypes. The detection limit for the HPV target DNA analysis improved from 1.2 nM to 30 pM by changing the silver development time from 5 to 10 min. Moreover, the enhanced silver development promoted by the gold nanoparticles could be applied to a broader range of target DNA concentration by controlling the silver development time. Figure An optical image of the PDA chip and target DNA detection through silver enhancement Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

4.
This study describes a simple and label-free electrochemical impedance spectroscopic (EIS) method for sequence-specific detection of DNA by using single-walled carbon nanotubes (SWNTs) as the support for probe DNA. SWNTs are confined onto gold electrodes with mixed self-assembly monolayers of thioethanol and cysteamine. Single-stranded DNA (ssDNA) probe is anchored onto the SWNT support through covalent binding between carboxyl groups at the nanotubes and amino groups at 5′ ends of ssDNA. Hybridization of target DNA with the anchored probe DNA greatly increases the interfacial electron-transfer resistance (Ret) at the double-stranded DNA (dsDNA)-modified electrodes for the redox couple of Fe(CN)63−/4−, which could be used for label-free and sequence-specific DNA detection. EIS results demonstrate that the utilization of SWNTs as the support for probe DNA substantially increases the surface loading of probe DNA onto electrode surface and thus remarkably lowers the detection limit for target DNA. Under the conditions employed here, Ret is linear with the concentration of target DNA within a concentration range from 1 to 10 pM with a detection limit down to 0.8 pM (S/N = 3). This study may offer a novel and label-free electrochemical approach to sensitive sequence-specific DNA detection.  相似文献   

5.
A detection system for a human papillomavirus (HPV) DNA chip based on the light scattering of aggregated silica nanoparticle probes is presented. In the assay, a target HPV DNA is sandwiched between the capture DNA immobilized on the chip and the probe DNA immobilized on the plain silica nanoparticle. The spot where the sandwich reaction occurs appears bright white and is readily distinguishable to the naked eye. Scanning electron microscopy images clearly show the aggregation of the silica nanoparticle probes. When three different sized (55 nm, 137 nm, 286 nm) plain silica nanoparticles were compared, probes of the larger silica nanoparticles showed a higher scattering intensity. Using 286-nm silica nanoparticles, the spots obtained with 200 pM of target DNA were visually detectable. The demonstrated capability to detect a disease related target DNA with direct visualization without using a complex detection instrument provides the prerequisite for the development of portable testing kits for genotyping.  相似文献   

6.
The potential ability of atomic force microscopy (AFM) as a quantitative bioanalysis tool is demonstrated by using gold nanoparticles as a size enhancer in a DNA hybridization reaction. Two sets of probe DNA were functionalized on gold nanoparticles and sandwich hybridization occurred between two probe DNAs and target DNA, resulting in aggregation of the nanoparticles. At high concentrations of target DNA in the range from 100 nM to 10 μM, the aggregation of gold nanoparticles was determined by monitoring the color change with UV-vis spectroscopy. The absorption spectra broadened after the exposure of DNA–gold nanoparticles to target DNA and a new absorption band at wavelengths >600 nm was observed. However, no differences were observed in the absorption spectra of the gold nanoparticles at low concentrations of target DNA (10 pM to 10 nM) due to insufficient aggregation. AFM was used as a biosensing tool over this range of target DNA concentrations in order to monitor the aggregation of gold nanoparticles and to quantify the concentration of target DNA. Based on the AFM images, we successfully evaluated particle number and size at low concentrations of target DNA. The calibration curve obtained when mean particle aggregate diameter was plotted against concentration of target DNA showed good linearity over the range 10 pM to 10 nM, the working range for quantitative target DNA analysis. This AFM-based DNA detection technique was three orders of magnitude more sensitive than a DNA detection method based on UV-vis spectroscopy.  相似文献   

7.
Pulsed amperometric detection (PAD) of target DNA with platinum electrodes modified by single-stranded DNA (ssDNA) entrapped within polypyrrole (ssDNA/Ppy) is reported for the first time. Single-stranded DNA 20-mers complementary to the target DNA were used to construct the DNA biosensors. Polymerase chain reaction (PCR) amplified bovine leukaemia virus (BLV) provirus DNA was used as target DNA. Electrochemical impedance spectroscopic (EIS) investigation of ssDNA/Ppy before and after incubation in target DNA-containing sample revealed significant changes in terms of an imaginary (Z) vs. a real (Z) component. The PAD results were in good agreement with EIS investigations. The PAD method was selected, because it does not require such sophisticated equipment as it is used to perform EIS and the results obtained can be more easily estimated. Optimum conditions for performing PAD and evaluating an analytical signal were elaborated. No label-binding step was necessary for detection of target DNA in PCR-amplified amplicons and detection time was reduced by as much as 30–35 min. The changes of PAD signals were at least 6–7 times higher if ssDNA/Ppy-modified electrodes instead of blank Ppy-modified electrodes were incubated in the target DNA solutions. If ssDNA/Ppy modified electrodes were incubated in non-complementary (control) DNA solution changes in PAD signals were smaller than those detected after incubation in complementary (target) DNA-containing solution by a factor of at least 6–8.  相似文献   

8.
A highly sensitive and label-free impedimetric biosensor is achieved based on an adjunct probe attached nearby the capture probe. In this work, the adjunct probe was co-assembled on the surface of gold electrode with the capture probe hybridized with the reporter probe, and then 6-mercapto-1-hexanol was employed to block the nonspecific binding sites. When target DNA was added, the adjunct probe functioned as a fixer to immobilize the element of reporter probe displaced by the target DNA sequences and made the reporter probe approach the electrode surface, leading to effective inhibition of charge transfer. The increase in charge transfer resistance is related to the quantity of the target DNA in a wide range. The linear range for target DNA with specific sequences was from 0.1 nM to 0.5 μM with a good linearity (R = 0.9988) and a low detection limit of 6.3 pM. This impedimetric biosensor has the advantages of simplicity, sensitivity, good selectivity, and large dynamic range.  相似文献   

9.
In this work, a novel multiplex electrochemiluminescence (ECL) DNA sensor has been developed for determination of hepatitis B virus (HBV) and hepatitis C virus (HCV) based on multicolor CdTe quantum dots (CdTe QDs) and Au nanoparticles (Au NPs). The electrochemically synthesized graphene nanosheets (GNs) were selected as conducting bridge to anchor CdTe QDs551-capture DNAHBV and CdTe QDs607-capture DNAHCV on the glassy carbon electrode (GCE). Then, different concentrations of target DNAHBV and target DNAHCV were introduced to hybrid with complementary CdTe QDs-capture DNA. Au NPs-probe DNAHBV and Au NPs-probe DNAHCV were modified to the above composite film via hybrid with the unreacted complementary CdTe QDs-capture DNA. Au NPs could quench the electrochemiluminescence (ECL) intensity of CdTe QDs due to the inner filter effect. Therefore, the determination of target DNAHBV and target DNAHCV could be achieved by monitoring the ECL DNA sensor based on Au NPs-probe DNA/target DNA/CdTe QDs-capture DNA/GNs/GCE composite film. Under the optimum conditions, the ECL intensity of CdTe QDs551 and CdTe QDs607 and the concentration of target DNAHBV and target DNAHCV have good linear relationship in the range of 0.0005–0.5 nmol L−1 and 0.001–1.0 nmol L−1 respectively, and the limit of detection were 0.082 pmol L−1 and 0.34 pmol L−1 respectively (S/N = 3). The DNA sensor showed good sensitivity, selectivity, reproducibility and acceptable stability. The proposed DNA sensor has been employed for the determination of target DNAHBV and target DNAHCV in human serum samples with satisfactory results.  相似文献   

10.
In this paper, a novel colorimetric biosensor for Hg2+ and DNA molecules is presented based on Hg2+ stimulated oxidase-like activity of bovine serum albumin protected silver clusters (BSA-Ag NCs). Under mild conditions, Hg2+ activated BSA-Ag NCs to show high catalytic activity toward the oxidation of 3,3′,5, 5′-tetramethylbenzidine (TMB) using ambient dissolved oxygen as an oxidant. The oxidase-like activity of BSA-Ag NCs was “switched-on” selectively in the presence of Hg2+, which permitted a novel and facile colorimetric sensor for Hg2+. As low as 25 nmol L−1 Hg2+ could be detected with a linear range from 80 nmol L−1 to 50 mmol L−1. In addition, the sensing strategy was also employed to detect DNA molecules. Hg2+ is known to bind very strongly and specifically with two DNA thymine bases (T) to form thymine–Hg2+–thymine (T–Hg2+–T) base pairs. The hairpin-structure was disrupted and Hg2+ ions were released after hybridization with the DNA target. By coupling the Hg2+ switched-on the oxidase-mimicking activity of BSA-Ag NCs, we developed a novel label-free strategy for facile and fast colorimetric detection of DNA molecules. More important, target DNA can be detected as low as 10 nmol L−1 with a linear range from 30 to 225 nmol L−1. Compared with other methods, this method presents several advantages such as the independence of hydrogen peroxide, high sensitivity and good selectivity, avoiding any modification or immobilization of DNA, which holds a great potential of metal NCs for clinical application in biosensing and biotechnology.  相似文献   

11.
A competitive DNA hybridization assay based on the photoelectrochemistry of the semiconductor quantum dot-single stranded DNA conjugates (QD-ssDNA) was developed. Hybridization of QD-ssDNA with the capture probe DNA immobilized on the indium–tin oxide electrodes enables photocurrent generation when the electrochemical cell was illuminated with a light source. Upon the competition between QD-ssDNA and single-stranded target DNA, the photocurrent response decreased with the increase in the target DNA concentration. A linear relationship between the photocurrent and the target DNA concentration was obtained (R 2 = 0.991). The selectivity of system towards the target DNA was also demonstrated using non-complementary sample.  相似文献   

12.
A new DNA hybridization analytical method using a microfluidic channel and a molecular beacon-based probe (MB-probe) is described. A stem-loop DNA oligonucleotide labeled with two fluorophores at the 5′ and 3′ termini (a donor dye, TET, and an acceptor dye, TAMRA, respectively) was used to carry out a fast and sensitive DNA analysis. The MB-probe utilized the specificity and selectivity of the DNA hairpin-type probe DNA to detect a specific target DNA of interest. The quenching of the fluorescence resonance energy transfer (FRET) signal between the two fluorophores, caused by the sequence-specific hybridization of the MB-probe and the target DNA, was used to detect a DNA hybridization reaction in a poly(dimethylsiloxane) (PDMS) microfluidic channel. The azoospermia gene, DYS 209, was used as the target DNA to demonstrate the applicability of the method. A simple syringe pumping system was used for quick and accurate analysis. The laminar flow along the channel could be easily controlled by the 3-D channel structure and flow speed. By injecting the MB-probe and target DNA solutions into a zigzag-shaped PDMS microfluidic channel, it was possible to detect their sequence-specific hybridization. Surface-enhanced Raman spectroscopy (SERS) was also used to provide complementary evidence of the DNA hybridization. Our data show that this technique is a promising real-time detection method for label-free DNA targets in the solution phase. Figure FRET-based DNA hybridization detection using a molecular beacon in a zigzag-shaped PDMS microfluidic channel  相似文献   

13.
In this work, gold nanoparticles (AuNPs) assembled on the surface of iron based metal–organic frameworks (MOFs), Fe-MIL-88, are facilely prepared through electrostatic interactions using polyethyleneimine (PEI) molecules as linker. The resulting hybrid materials possess synergetic peroxidase-like activity. Because iron based metal–organic frameworks, Fe-MIL-88, exhibits highly peroxidase-like activity, and AuNPs has the distinct adsorption property to single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA). The peroxidase-like activity of Au@Fe-MIL-88 exhibit excellent switchable in response to specific DNA, ssDNA is easily adsorbed on the surface of the Au@Fe-MIL-88 hybrids, resulting in the reduce of the peroxidase-like activity of the hybrids. While it is recovered by the addition of target DNA, and the recovery degree is proportional to the target DNA concentration over the range of 30–150 nM with a detection limit of 11.4 nM. Based on these unique properties, we develop a label-free colorimetric method for DNA hybridization detection. In control experiment, base-mismatched DNA cannot induce recovery of the peroxidase-like activity. This detection method is simple, cheap, rapid and colorimetric.  相似文献   

14.
In the present study, an inductively-coupled plasma-mass spectrometry (ICP-MS)-based triple-amplification system, by combination of nicking–displacement, rolling circle amplification (RCA) and bio-bar-code probes, was fabricated for the detection of DNA target. By using this system, hepatitis B virus (HBV) DNA target down to 3.2 × 10−17 M was detected by DNA probes labeled with Au nanoparticles (AuNPs). Single nucleotide polymorphisms in genes can also be effectively discriminated. In addition, we proved that this strategy is capable of detecting the target in complicated biological samples and holds great potential application in biomedical research.  相似文献   

15.
Using a cascade signal amplification strategy, an ultrasensitive electrochemical biosensor for specific detection of DNA based on molecular beacon (MB) mediated circular strand displacement polymerization (CSDP) and hyperbranched rolling circle amplification (HRCA) was proposed. The hybridization of MB probe to target DNA resulted in a conformational change of the MB and triggered the CSDP in the presence of bio-primer and Klenow fragment (KF exo), leading to multiple biotin-tagged DNA duplex. Furthermore, the HRCA was implemented to product amounts of double-stranded DNA (ds-DNA) fragments using phi29 DNA polymerase via biotin-streptavidin interaction. After the product of HRCA binded numerous biotinylated detection probes, an ultrasensitive electrochemical readout by further employing the streptavidin-alkaline phosphatase. The proposed biosensor exhibited excellent detection sensitivity and specificity with a log-linear response to target DNA from 0.01 fM to 10 pM as low as 8.9 aM. The proposed method allowed DNA detection with simplicity, rapidness, low cost and high specificity, which might have the potential for application in clinical molecular diagnostics and environmental monitoring.  相似文献   

16.
Zhang H  Wang M  Gao Q  Qi H  Zhang C 《Talanta》2011,84(3):771-776
A novel fluorescent method for the detection of single nucleotide polymorphism (SNP) was developed using a hairpin DNA containing nucleotide base analog pyrrolo-deoxycytidine (P-dC) as a fluorescent probe. This fluorescent probe was designed by incorporating a fluorescent P-dC into a stem of the hairpin DNA, whose sequence of the loop moiety complemented the target single strand DNA (ss-DNA). In the absence of the target ss-DNA, the fluorescent probe stays a closed configuration in which the P-dC is located in the double strand stem of the fluorescent probe, such that there is weak fluorescence, attributed to a more efficient stacking and collisional quenching of neighboring bases. In the presence of target ss-DNA, upon hybridizing the ss-DNA to the loop moiety, a stem-loop of the fluorescent probe is opened and the P-dC is located in the ss-DNA, thus resulting in strong fluorescence. The effective discrimination of the SNP, including single base mismatch ss-DNA (A, T, G) and double mismatch DNA (C, C), against perfect complementary ss-DNA was achieved by increased fluorescence intensity, and verified by thermal denaturation and circular dichroism spectroscopy. Relative fluorescence intensity had a linear relationship with the concentration of perfect complementary ss-DNA and ranged from 50 nM to 3.0 μM. The linear regression equation was F/F0 = 2.73 C (μM) + 1.14 (R = 0.9961) and the detection limit of perfect complementary ss-DNA was 16 nM (S/N = 3). This study demonstrates that a hairpin DNA containing nucleotide base analog P-dC is a promising fluorescent probe for the effective discrimination of SNP and for highly sensitive detection of perfect complementary DNA.  相似文献   

17.
It was found that tripropylamine (TPA) could be used as a coreactant to initiate the electrochemiluminescence (ECL) of acridinium NHS ester (AE NHS) labels attached to DNA. The radicals generated in the electro-oxidation process of TPA reacted with AE NHS to form the excited N-methylacridone, giving rise to light emission. The AE/TPA ECL system was for the first time used as the detection system for developing an ECL-based DNA sensor. In the protocol, streptavidin-modified gold nanoparticles were firstly immobilized onto a thiol-treated gold electrode. The streptavidin could specifically interact with the biontinylated capture DNA. Afterwards, the target DNA and the AE-labeled report DNA were conjugated onto the electrode step by step due to the hybridization reactions, and a sandwich-type sensor was fabricated. The ECL signals of the sensor were obtained under pulse potential condition in alkaline solution containing 50.0 mmol L−1 TPA. Under optimized experimental conditions, the linear range of the DNA sensor for the determination of the target DNA was from 5.0 × 10−15 to 5.0 × 10−12 mol L−1. The detection limit (S/N = 3) was 3.0 × 10−15 mol L−1. Moreover, the sensor could specifically recognize the target DNA against one base-pair mismatched sequences, two base-pair mismatched sequences, and the noncomplementary sequences. It is of great application potential in clinic analysis.  相似文献   

18.
The development of simple and inexpensive DNA detection strategy is very significant for droplet-based microfluidic system. Here, a droplet-based biosensor for multiplexed DNA analysis is developed with a common imaging device by using fluorescence-based colorimetric method and a graphene nanoprobe. With the aid of droplet manipulation technique, droplet size adjustment, droplet fusion and droplet trap are realized accurately and precisely. Due to the high quenching efficiency of graphene oxide (GO), in the absence of target DNAs, the droplet containing two single-stranded DNA probes and GO shows dark color, in which the DNA probes are labeled carboxy fluorescein (FAM) and 6-carboxy-X-rhodamine (ROX), respectively. The droplet changes from dark to bright color when the DNA probes form double helix with the specific target DNAs leading to the dyes far away from GO. This colorimetric droplet biosensor exhibits a quantitative capability for simultaneous detection of two different target DNAs with the detection limits of 9.46 and 9.67 × 10−8 M, respectively. It is also demonstrated that this biosensor platform can become a promising detection tool in high throughput applications with low consumption of reagents. Moreover, the incorporation of graphene nanoprobe and droplet technique can drive the biosensor field one more step to some extent.  相似文献   

19.
We report preparation of a novel platform for effective DNA hybridization and its application to the detection of single mismatched DNA. Cone-shaped dendrimer molecules have been immobilized on the gold surface at equidistance, 3.1 nm, from each other with a probe DNA molecule attached to the top of each dendrimer so that enough space would be secured for effective hybridization. This arrangement allows each probe DNA molecule to form a natural DNA double helix upon hybridization with a target DNA molecule. The single nucleotide polymorphism at either the central or end position of the 25-mer target DNA has been shown to be effectively discriminated against on this platform from each other as well as from a complementary DNA by electrochemical impedance measurements. We also report adverse effects exerted by probe ions, Fe(CN)63−/4−, on DNA hybridization reactions. The significance of the results for the use in DNA analysis is discussed.  相似文献   

20.
Li J  Yao QH  Fu HE  Zhang XL  Yang HH 《Talanta》2011,85(1):91-96
Horseradish peroxidase mimicking DNAzyme (HRP-DNAzyme) attracts growing interest as an amplifying label for biorecognition and biosensing events, especially for DNA detection. However, in the traditional designs, one target molecule can only generate one HRP-DNAzyme, which limits the signal enhancement and thus its sensitivity. In this article, we propose an amplified and label-free colorimetric DNA detection strategy based on nicking endonuclease (NEase)-assisted activation of HRP-DNAzymes (NEAA-DNAzymes). This new strategy relies on the hairpin-DNAzyme probe and NEase-assisted target recycling. In the hairpin-DNAzyme probe, the HRP-DNAzyme sequence is protected in a “caged” inactive structure, whereas the loop region includes the target complementary sequence. Upon hybridization with target, the beacon is opened, resulting in the activation of the HRP-DNAzyme. Meanwhile, upon formation of the duplex, the NEase recognizes a specific nucleotide sequence and cleaves the hairpin-DNAzyme probe into two fragments. After nicking, the fragments of the hairpin-DNAzyme probe spontaneously dissociate from the target DNA. Amplification is accomplished by another hairpin-DNAzyme probe hybridizing to the released intact target to continue the strand-scission cycle, which results in activation of numerous DNAzymes. The activated HRP-DNAzymes generate colorimetric or chemiluminescence readout signals, thus providing the amplified detection of DNA. The detection limit of the colorimetric method is 10 pmol/L, which are three orders of magnitude lower than that without NEase. In addition, the detection limit of the chemiluminescence method is 0.2 pmol/L. Meanwhile, this strategy also exhibits high discrimination ability even against single-base mismatch.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号