首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A 3D-immunosensor based on simple and efficient trapping platform (foam Ni) combining with adsorption of gold nanoparticles and specific recognition of biological/chemical molecular has been reported for detection of sulfate-reducing bacteria (SRB) using electrochemical impedance spectroscopy (EIS). The impedance spectra were also used to characterize the successful construct and stepwise modification of the impedimetric immunosensors. This results show that a linear relationship between electron-transfer resistance (Rct) values and the logarithm of the SRB concentrations was obtained for the SRB concentration range of 2.1 × 101–2.1 × 107 cfu/ml. Additionally, the fabricated immunosensor shows a high selectivity against other bacteria.  相似文献   

2.
An amplified electrochemical impedimetric aptasensor for ochratoxin A (OTA) was developed with picomolar sensitivity. A facile route to fabricate gold nanoparticles covalently bound reduced graphene oxide (AuNPs–rGO) resulted in a large number of well-dispersed AuNPs on graphene sheets with tremendous binding sites for DNA, since the single rGO sheet and each AuNP can be loaded with hundreds of DNA strands. An aptasensor with sandwich model was fabricated which involved thiolated capture DNA immobilized on a gold electrode to capture the aptamer, then the sensing interface was incubated with OTA at a desired concentration, followed by AuNPs–rGO functionalized reporter DNA hybridized with the residual aptamers. By exploiting the AuNPs–rGO as an excellent signal amplified platform, a single hybridization event between aptamer and reporter DNA was translated into more than 107 redox events, leading to a substantial increase in charge-transfer resistance (Rct) by 7∼ orders of magnitude compared with that of the free aptamer modified electrode. Such designed aptasensor showed a decreased response of Rct to the increase of OTA concentrations over a wide range of 1 pg mL−1–50 ng mL−1 and could detect extremely low OTA concentration, namely, 0.3 pg mL−1 or 0.74 pM, which was much lower than that of most other existed impedimetric aptasensors. The signal amplification platform presented here would provide a promising model for the aptamer-based detection with a direct impedimetric method.  相似文献   

3.
This paper describes the characterization of the gold-catalyzed deposition of silver on graphite screen-printed electrodes (SPEs) using electrochemical impedance spectroscopy (EIS) and the application of this approach to the development of impedimetric immunosensors. After applying −0.1 V for 45 s, the amount of electrodeposited silver quantitatively changes the magnitude of two elements of the electrical equivalent circuit: the interface capacitance, Ci, and the charge-transfer resistance, RCT. Better correlations have been found when considering the RCT since this parameter is almost exclusively dependent on the amount of deposited silver under these experimental conditions. This approach has been successfully applied to the development of an impedimetric immunosensor for aflatoxin M1. The RCT magnitude shows good correlation with the amount of gold immobilized on the electrode surface after a competitive assay and thus, with the toxin concentration. This approach has been found sensitive in a wide range of concentrations, from 15 to 1000 free-AFM1 ppt with a limit of detection of 12 ppt.  相似文献   

4.
A highly sensitive impedimetric immunosensor based on a gold nanoparticles/multiwall carbon nanotube-ionic liquid electrode (AuNPs/MW-CILE) was developed for the determination of human epidermal growth factor receptor 2 (HER2). Gold nanoparticles were used to enhance the extent of immobilization and to retain the immunoactivity of the antibody Herceptin on the electrode. Cyclic voltammetry and electrochemical impedance spectroscopy were employed for characterization of various layers coated onto the AuNPs/MW-CILE. The impedance measurements at different steps were based on the charge transfer kinetics of the [Fe(CN)6]3−/4− redox pair. The immobilization of antibody and the corresponding antigen–antibody interaction at the electrode surface altered the interfacial electron transfer. The interactions of antibody with various concentrations of antigen were also monitored via the change of impedance response. The results showed that the charge transfer resistance increases linearly with increasing concentrations of HER2 antigen. The linear range and limit of detection were found as 10–110 ng mL−1 and 7.4 ng mL−1, respectively. The sensitivity and specificity of the immunosensor were validated. The results showed that the prepared immunosensor is a useful tool for screening of trace amounts of HER2 in serum samples of breast cancer patients.  相似文献   

5.
A sensitive and label-free electrochemical impedance immunosensor via covalent coupling the antibody with functionalized gold nanoparticles (FAuNP) for probing apolipoprotein A-I was presented. The hybrid gold nanoparticles were prepared with a two-in-one strategy, i.e. via the stepwise employment of self-assembled monolayer (SAM) and sol-gel techniques, to improve the performance of such a label-free immunosensor, which was investigated by electrochemical impedance spectroscopy. It was found that this novel FAuNP immunosensor showed higher protein-loading capacity and better response properties (6-17 times) than that fabricated by normal SAM technique did. The remarkably improved properties of the immunosensor were ascribed to FAuNP with the larger surface-to-volume ratio, more free amino linkage groups, and the lower nonspecific protein adsorption. As a result, the thus-prepared antibody-modified immunosensor showed reproducible (R.S.D. = ±3.2%, n = 10) linear response to apolipoprotein A-I (Apo A-I) antigens in the range of 0.1-10 ng mL−1. The detection limit of this immunosensor was 50 pg mL−1 (corresponding to 1.8 pmol L−1), which was two orders of magnitude lower than that of the traditional methods. These results exhibited the novel immunosensor had a high sensitivity, stability and selectivity for the determination of Apo A-I, especially in clinic microanalysis.  相似文献   

6.
The development of a faradic impedimetric immunosensor based on electropolymerized polytyramine (Ptyr) films for the detection of S. typhimurium in milk is described for the first time. Polyclonal anti-Salmonella was cross-linked, in the presence of glutaraldehyde vapors, on Ptyr-modified gold electrodes. The dielectric behaviour of Ptyr films was evaluated with capacitance measurements, while their stability in neutral aqueous solutions was examined with impedimetric measurements. The effect of the concentration of tyramine in the forming solution on both the sensitivity and the dynamic range of the resulted immunosensors was also investigated. The alteration of the interfacial features of the electrodes due to different modification or recognition steps, was measured by faradic electrochemical impedance spectroscopy in the presence of a hexacyanoferrate(II)/(III) redox couple. At samples containing a low initial concentration of 10 cfu mL−1S. typhimurium, that actually defines the LOD of the immunosensors, signal changes of 33% and 88% were achieved after 3 and 10 h incubation, respectively. To achieve the working simplicity expected by a biosensor, immunoreaction was performed directly in cultures. This resulted in the elimination of various centrifugation and washing steps, which are used for the isolation of bacteria cells from the culture, thus making the proposed immunosensors promising candidates for on-site applications. Finally, the proposed immunosensors were successfully used for the detection of S. typhimurium in experimentally inoculated milk samples.  相似文献   

7.
A new method for the pretreatment of screen-printed carbon electrodes (SPCEs) by two successive steps was proposed. In step one, fresh SPCEs were soaked into NaOH with high concentration (e.g. 3 M) for tens to hundreds of minutes, and the resulted electrodes were called as SPCE-I. In step two, SPCE-I were pre-anodized in low concentration of NaOH, which were designated as SPCE-II. The pretreated electrodes showed remarkable enhancement in heterogeneous electron transfer rate constant (k0) increased from 1.6 × 10−4 cm s−1 at the fresh SPCE to 1.1 × 10−2 cm s−1 at SPCE-I for Fe(CN)63−/4− couple. The peak to peak separation (ΔEp) in cyclic voltammetry was reduced from ca. 480 to 84 mV, indicating that the electrochemical reversibility was greatly promoted, possibly due to the removing of polymers/oil binder from the electrode surfaces. The electroactive area (Aea) of the electrode was increased by a factor of 17 after pretreatment in step one. Further analysis by the electrochemical impedance method showed that the electron transfer resistance (Rct) decreased from ca. 2100 to 1.4 Ω. These pretreated electrodes, especially SPCE-II, exhibited excellent electrocatalytic behavior for the redox of dopamine (DA). Interference from ascorbic acid (AA) in the detection of DA at SPCE-II could be effectively eliminated due to the anodic peak separation (190 mV) between DA and AA, which resulted from the functionalization of the electrode surface in the pretreatment of step two. Under optimum conditions, current responses to DA were linearly changed in two concentration intervals, one was from 3.0 × 10−7 to 9.8 × 10−6 M, and the other was from 9.8 × 10−6 to 3.3 × 10−4 M. The detection limit for DA was down to 1.0 × 10−7 M.  相似文献   

8.
In the presented work, a disposable immunosensor for the detection of testosterone, an endogenous steroid hormone, in bovine urine has been developed using screen-printed electrodes (SPEs). Due to concerns over the use of steroid hormones as growth promoters, the EU prohibits their use in food producing animals. Consequently, rigorous screening procedures have been implemented in all member states to detect the illegal administration of such compounds. Competitive immunoassays were developed, initially by enzyme linked immunosorbent assay (ELISA), and subsequently transferred to an electrochemical immunosensor format using disposable screen-printed carbon electrodes. Horseradish peroxidase (HRP) was the enzyme label of choice and chronoamperometric detection was carried out using a tetramethylbenzidine/hydrogen peroxide (TMB/H2O2) substrate system, at +100 mV. The EC50 values obtained for the assay in buffer and urine gave relatively comparable results, 710 pg mL−1 and 960 pg mL−1, respectively. The linear range obtained for the assay in buffer extended from 0.03 ng mL−1 to 40 ng mL−1; while that in urine ranged from 0.03 ng mL−1 to 1.6 ng mL−1. The corresponding limits of detection (LOD) in buffer and urine were 26 pg mL−1 and 1.8 pg mL−1. Cross reactivity profiles of the antibody have been examined, with notable cross reactivities with 19-nortestosterone (11.6%) and boldenone (9.86%). Precision studies for the sensor demonstrated adequate reproducibility (CV < 13%, n = 3) and repeatability (CV < 9%, n = 3). Recovery data obtained showed good agreement between spiking studies and known concentrations of analyte. Sensors showed stability for 4 days at +4 °C. A sensitive, highly specific, inexpensive, disposable immunosensor, showing excellent overall performance for the detection of testosterone in bovine urine, has been developed.  相似文献   

9.
Fabrication of a novel capacitive immunosensor based on grafted ethylene diamine and self-assembled gold nanoparticle monolayer on glassy carbon electrode for the detection of Salmonella spp. is described for the first time. In the present study, the Salmonella spp. monoclonal antibodies (denoted as McAbs) was immobilized on gold nanoparticles. Interaction of McAbs and Salmonella spp. was detected directly using the electrochemical impedance spectroscopy (EIS) technique. The experimental results showed that the concentration of antigen was measured through the relative change in capacitance in the corresponding specific binding of Salmonella spp. and McAbs. Under the optimized conditions, the relative changes in capacitance were proportional to the logarithmic values of Salmonella spp. concentrations in the range of 1.0 × 102 to 1.0 × 105 CFU mL−1 (r = 0.991) with the detection limit of 1.0 × 102 CFU mL−1. The stability of proposed immunosensor could be estimated by determining the relative change in capacitance, which remained almost the same in two months and decreased gradually to 85.3% of initial value after four months’ storage. The used immunosensor could be regenerated repeatedly by immersing in glycine-HCl buffer solution (pH 2.8). Finally, the proposed immunosensor was successfully used for the detection of Salmonella spp. in lab-processed commercial pork samples.  相似文献   

10.
A novel cobalt-tetraphenylporphyrin/reduced graphene oxide (CoTPP/RGO) nanocomposite was prepared by a π–π stacking interaction and characterized by ultraviolet–visible absorption spectroscopy (UV–vis), Fourier transform infrared spectroscopy (FTIR) and electrochemical impedance spectroscopy (EIS). The CoTPP/RGO nanocomposite exhibited high electrocatalytic activity both for oxidation and reduction of H2O2. The current response was linear to H2O2 concentration with the concentration range from 1.0 × 10−7 to 2.4 × 10−3 mol L−1 (R = 0.998) at the reductive potential of −0.20 V and from 1.0 × 10−7 to 4.6 × 10−4 mol L−1 (R = 0.996) at the oxidative potential of +0.50 V. The H2O2 biosensor showed good anti-interfering ability towards oxidative interferences at the oxidative potential of +0.50 V and good anti-interfering ability towards reductive interferences at the reductive potential of −0.20 V.  相似文献   

11.
In this work we report the fabrication and characterization of a label-free impedimetric immunosensor based on a silicon nitride (Si3N4) surface for the specific detection of human serum albumin (HSA) proteins. Silicon nitride provides several advantages compared with other materials commonly used, such as gold, and in particular in solid-state physics for electronic-based biosensors. However, few Si3N4-based biosensors have been developed; the lack of an efficient and direct protocol for the integration of biological elements with silicon-based substrates is still one of its the main drawbacks. Here, we use a direct functionalization method for the direct covalent binding of monoclonal anti-HSA antibodies on an aldehyde-functionalized Si-p/SiO2/Si3N4 structure. This methodology, in contrast with most of the protocols reported in literature, requires less chemical reagents, it is less time-consuming and it does not need any chemical activation. The detection capability of the immunosensor was tested by performing non-faradaic electrochemical impedance spectroscopy (EIS) measurements for the specific detection of HSA proteins. Protein concentrations within the linear range of 10−13–10−7 M were detected, showing a sensitivity of 0.128 Ω μM−1 and a limit of detection of 10−14 M. The specificity of the sensor was also addressed by studying the interferences with a similar protein, bovine serum albumin. The results obtained show that the antibodies were efficiently immobilized and the proteins detected specifically, thus, establishing the basis and the potential applicability of the developed silicon nitride-based immunosensor for the detection of proteins in real and more complex samples.  相似文献   

12.
Development of a chemiluminescent immunosensor for chloramphenicol   总被引:3,自引:0,他引:3  
A direct competitive chemiluminescent immunosensor system that exploits the competition between chloramphenicol (CAP) as an analyte and CAP-horseradish peroxidase conjugate as a tracer for binding to an anti-CAP antibody on a solid support was devised by installing a flow-through cell which was connected to an injector and a peristaltic pump inside a dark box, followed by positioning a photomultiplier tube as light detector in front of it. The anti-CAP antibody was immobilized onto positively charged Biodyne B membrane pieces by a dipping procedure. The operating conditions for the immunosensor were selected with respect to substrate composition (0.25, 13.3 and 0.66 mM for luminol, H2O2 and p-iodophenol, respectively), injection volume of the substrate solution (200 μL) and the concentrations of antibody for immobilization (0.10 mg mL−1) and tracer (0.030 mg mL−1). At these conditions, sensor response according to analyte concentration was well fitted to a linear equation when plotted in semi-logarithmic scale, with the limit of detection for CAP of 10−8 M. By using the immunosensor, CAP measurement in the model samples prepared from five food materials was conducted.  相似文献   

13.
A double electrochemical covalent coupling method based on click chemistry and diazonium chemistry for the fabrication of sensitive amperometric immunosensor was developed. As a proof-of-concept, a designed alkyne functionalized human IgG was used as a capture antibody and a HRP-labeled rabbit anti-goat IgG was used as signal antibody for the determination of the anti-human IgG using the sandwich model. The immunosensor was fabricated by electrochemically grafting a phenylazide on the surface of a glassy carbon electrode, and then, by coupling the alkyne functionalized human IgG with the phenylazide group through an electro-click chemistry in the presence of Cu(II). The amperometric measurement for the determination of the anti-human IgG was performed after the fabricated immunosensor was incubated with the target anti-human IgG and then with the HRP-labeled anti-goat IgG at −0.25 V in 0.10 M PBS (pH 7.0) containing 0.1 mM hydroquinone and 2.0 mM H2O2. The results showed that the increased current was linear with the logarithm of the concentration of the anti-human IgG in the range from 1.0 × 10−10 g mL−1 to 1.0 × 10−8 g mL−1 with a detection limit of 3 × 10−11 g mL−1. Furthermore, the feasibility of the double electrochemical covalent coupling method proposed in this work for fabricating the amperometric immunosensor array was explored. This work demonstrates that the double electrochemical covalent coupling method is a promising approach for the fabrication of the immunosensor and immunosensor array.  相似文献   

14.
An early on time detection of breast cancer significantly affects the treatment process and outcome. Herein, a new label-free impedimetric biosensor is developed to determine the lowest change in the level of calreticulin (CALR), which is a new biomarker of breast carcinoma. The proposed immunosensor is fabricated by using reduced graphene oxide/amino substituted polypyrrole polymer (rGO-PPyNH2) nanocomposite modified disposable electrode. The anti-CALR antibodies are first attached on the rGO-PPyNH2 nanocomposite coated electrode through glutaraldehyde crosslinking; the CALR antigens are then immobilized with the addition of CALR antigens to form an immunocomplex on the sensing surface. This immunocomplex induces considerably larger interfacial electron transport resistance (Rct). The variation in the Rct has a linear relationship with CALR level in the detection range of 0.025 to 75 pg mL−1, with a detection limit of 10.4 fg mL−1. The suggested biosensor shows high selectivity to CALR, good storage stability (at least 5 weeks) and suitable reproducibility results as shown in quality control chart. The designed immunosensor is utilized to analyze CALR levels in human sera with satisfying results. This immunosensor provides a novel way for the clinical determination of CALR and other cancer biological markers.  相似文献   

15.
A capacitive immunosensor for detection of cholera toxin   总被引:2,自引:0,他引:2  
Contamination of food with biological toxins as well as their potential use as weapons of mass destruction has created an urge for rapid and cost effective analytical techniques capable of detecting trace amounts of these toxins. This paper describes the development of a sensitive method for detection of cholera toxin (CT) using a flow-injection capacitive immunosensor based on self-assembled monolayers. The sensing surface consists of monoclonal antibodies against the B subunit of CT (anti-CT), immobilized on a gold transducer. Experimental results show that the immunosensor responded linearly to CT concentrations in the range from 1.0 × 10−13 to 1.0 × 10−10 M under optimized conditions. The limit of detection (LOD) was 1.0 × 10−14 M. Two more analytical methods were employed for detection of CT using the same antibody namely, sandwich ELISA and surface plasmon resonance (SPR)-based immunosensor. The former had an LOD of 1.2 × 10−12 M and a working range from 3.7 × 10−11 to 2.9 × 10−10 M whereas, the later had an LOD of 1.0 × 10−11 M and a linearity ranging from 1.0 × 10−9 to 1.0 × 10−6 M. These results demonstrate that the developed capacitive immunosensor system has a higher sensitivity than the other two techniques. The binding affinity of CT to the immobilized anti-CT was determined using the SPR-based immunosensor and an association constant (KA) of 1.4 × 109 M−1 was estimated.  相似文献   

16.
Caifeng Ding  Fei Zhao  Jin-Ming Lin 《Talanta》2009,78(3):1148-4751
A novel and effective electrochemical immunosensor for the rapid determination of α-fetoprotein (AFP) based on carbon paste electrode (CPE) consisting of room temperature ionic liquid (RTIL) N-butylpyridinium hexafluorophosphate (BPPF6) and graphite. The surface of the CPE was modified with gold nanoparticles for the immobilization of the α-fetoprotein antibody (anti-AFP). By sandwiching the antigen between anti-AFP on the CPE modified with gold nanoparticles and the secondary antibody, polyclonal anti-human-AFP labeled with horseradish peroxidase (HRP-labeled anti-AFP), the immunoassay was established. The concentration of AFP was determined based on differential pulse voltammetry (DPV) signal, which was generated in the reaction between O-aminophenol (OAP) and H2O2 catalyzed by HRP labeled on the sandwich immunosensor. AFP concentration could be measured in a linear range of 0.50-80.00 ng mL−1 with a detection limit of 0.25 ng mL−1. The immunosensor exhibited high sensitivity and good stability, and would be valuable for clinical assay of AFP.  相似文献   

17.
Despite the wide applicability and specificity of lectins to carbohydrate moieties, there are few lectin specific biosensors. This is attributed to the difficulty in defining the relevant experimental parameters to measure for sensing. We hereby describe the development of direct and indirect electrochemical sensors to determine the exact trace amounts of probarley lectin (ProBL) and its conversion product wheat germ agglutinin (WGA). In addition to WGA, the antigens (ProBL) employed in this study were over expressed in bacteria, isolated from protein bodies, and purified using immobilized N-acetylglusamine in order to obtain correctly folded active lectins. The amperometric immunosensor uses cell lines producing monoclonal antibody (mAB) to the pro-region of ProBL over expressed from Escherichia coli. The efficacy and sensing characteristics of the lectin were optimized using monoclonal antibody to WGA and the resulting sensor was found to detect only ProBL in the linear range 10−3-102 μg mL−1 and a detection limit of 10−3 μg mL−1.  相似文献   

18.
A new electrochemical immunosensor for sensitive determination of thyroid-stimulating hormone (TSH) was designed by using redox-active nanogold-functionalized magnetic beads (GoldMag) as signal tags on the nanogold–graphene interface. To construct such GoldMag nanostructures, polyethyleneimine-functionalized magnetic beads (PEI-MBs) were initially prepared by using a wet chemical method, and the electroactive thionine molecules and gold nanoparticles were then alternately immobilized on the surface of PEI-MBs by using an opposite-charged adsorption technique and an in situ synthesis method, respectively. The synthesized GoldMag nanostructures were utilized as signal tags for the label of horseradish peroxidase-anti-TSH conjugates (HRP-anti-TSH). With a sandwich-type immunoassay format, the conjugated signal tags on the transducer were increased with the increasing TSH concentration in the sample, thus enhancing the signal of the electrochemical immunosensor due to the labeled HRP toward the catalytic reduction of H2O2. Under optimal conditions, the current was proportional to the logarithm of TSH concentration ranging from 0.01 to 20 μIU mL−1 in pH 6.0 HAc–NaAc containing 6 mM H2O2. The detection limit (LOD) was 0.005 μIU mL−1 TSH at 3sB. The immunosensor displayed an acceptable reproducibility, stability and selectivity. In addition, the methodology was evaluated with human serum specimens, receiving good correlation with results from commercially available electrochemiluminescent analyzer.  相似文献   

19.
Electrochemical characterization of gold cysteamine self-assembled monolayer, in situ functionalized with ethylenediaminetetraacetic acid (Au-CA-EDTA SAM), is described by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and Osteryoung square wave voltammetry (OSWV). The results obtained by EIS and CV, in the presence of [Fe(CN)6]3−/4− redox probe, show that EDTA is successfully grafted to the surface of Au-CA electrode. Reproducible and reversible variation of the Rct and ΔEp as a function of solution pH show that Au-CA-EDTA SAM is stable in a wide range of pH and potentials. Accumulation of the Pb2+ and Cu2+ ions on the Au-CA-EDTA SAM electrode is investigated using faradaic currents or impedimetric effects measured by OSWV and EIS, respectively. These results reveal the presence of active complexing functional groups of EDTA on the surface, and thus, the formation of Au-CA-EDTA SAM electrode. The new sensor responds to the Pb2+ and Cu2+ separately and simultaneously in a wide linear range of concentrations.  相似文献   

20.
Yi Wan  Dun Zhang  Baorong Hou 《Talanta》2010,82(4):1608-1611
A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB), Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of −1.3 V, deposition time of 250 s, ionic strength of 0.2 mol L−1 and oxidant mercury (II) concentration of 40 mg L−1). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 × 10 to 2.3 × 107 cfu mL−1. In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号