首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
Differential pulse voltammetry (DPV) at a carbon fibre rod electrode (CFRE) and a capillary carbon paste electrode (CPE) have been used for the determination of pesticides cymoxanil and famoxadone, respectively. In the cathodic potential range, optimum conditions were found for the determination of cymoxanil by DPV at CFRE at pH 4 with limit of quantification (LQ) of 5.9×10?7 mol L?1. In the anodic area, determination of famoxadone by DPV at CPE was performed at optimum pH 2 with LQ=1.4×10?7 mol L?1. Practical applicability of the newly developed methods was verified on spiked samples of river water and soil.  相似文献   

2.
This study investigates a new approach for the amperometric determination of sulfide using a hematoxylin multiwalled carbon nanotubes modified carbon paste electrode (HM‐MWCNTs/CPE). The experimental results show that HM‐MWCNTs/CPE significantly enhances the electrocatalytic activity towards sulfide oxidation. Cyclic voltammetric studies show that the peak potential of sulfide shifted from +400 mV at unmodified CPE to +175 mV at HM‐MWCNTs/CPE. The currents obtained from amperometric measurements at optimum conditions were linearly correlated with the concentration of sulfide. The calibration curve was obtained for sulfide concentrations in the range of 0.5–150×10?6 mol L?1. The detection limit was found to be 0.2×10?6 mol L?1 for the amperometric method. The proposed method was successfully applied to a river water sample in Pardubice, Czech Republic.  相似文献   

3.
A novel potentiometric sensor, based on carbon paste electrode (CPE), modified with ion-imprinted polymer (IIP) and multi-walled carbon nanotubes (MWCNTs), is introduced for detection of chromium (III). The IIP nanomaterial was synthesised and characterised by using scanning electron microscopy and Fourier Transform Infrared. The modification of the CPE with the IIP (as a ionophore) resulted in an all-solid-state Cr(III)-selective sensor. However, the presence of appropriate amount of MWCNTs in the electrode composition was found to be necessary to observe Nernstian response. The optimised electrode composition was 76.7% graphite, 14.3% binder, 5% IIP, and 4% CNT. The proposed sensor exhibited Nernstian slope of 20.2 ± 0.2 mV decade?1 in the working concentration range of 1.0 × 10?6?1.0 × 10?1 mol L?1 (52 µg L?1–5.2 g L?1), with a detection limit of 5.9 × 10?7 mol L?1 (30.68 µg L?1) and a fast response time of less than 40 s. It displayed a stable potential response in the pH range of 2–5. It exhibited also high selectivity over some interfering ions. The proposed sensor was successfully applied for the determination of Cr(III) in real samples (sea, river water and soil).  相似文献   

4.
5.
A simple and fast voltammetric method based on a new electrode composed of carbon paste electrode/bifunctional hybrid ion imprinted polymer (CPE/IIP) was developed for the quantification of Cd2+ in water samples. The voltammetric measurements by Differential Pulse Voltammetry were performed by using CPE containing 11.0 mg of IIP under phosphate buffer solution at concentration 0.1 mol L?1 and pH 6.5. The electrochemical method was carried out by Cd2+ preconcentration at ?1.2 V during 210 s, followed by anodic stripping. The performance of IIP towards Cd2+ determination was evaluated by comparison to non-imprinted polymer, whose detectability of IIP was much higher (45%). The sensitivity of the sensor was found to be 0.0105 µA/µg L?1. The limits of detection and limits of quantification were found to be 4.95 μg L?1 and 16.4 μg L?1, respectively. The developed method was successfully applied to Cd2+ determination in mineral, tap and lake water samples, whose results are in agreement with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) used as reference analytical technique. According to achieved results, the developed method can be used for routine analysis of quality control of water samples from different sources.  相似文献   

6.
The voltammetric behavior of two genotoxic nitro compounds (4‐nitrophenol and 5‐nitrobenzimidazole) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p‐AgSAE), a mercury meniscus modified silver solid amalgam electrode (m‐AgSAE), and a mercury film modified silver solid amalgam electrode (MF‐AgSAE). The optimum conditions have been evaluated for their determination in Britton‐Robinson buffer solutions. The limit of quantification (LQ) for 5‐nitrobenzimidazole at p‐AgSAE was 0.77 µmol L?1 (DCV) and 0.47 µmol L?1 (DPV), at m‐AgSAE it was 0.32 µmol L?1 (DCV) and 0.16 µmol L?1 (DPV), and at MF‐AgSAE it was 0.97 µmol L?1 (DCV) and 0.70 µmol L?1 (DPV). For 4‐nitrophenol at p‐AgSAE, LQ was 0.37 µmol L?1 (DCV) and 0.32 µmol L?1 (DPV), at m‐AgSAE it was 0.14 µmol L?1 (DCV) and 0.1 µmol L?1 (DPV), and at MF‐AgSAE, it was 0.87 µmol L?1 (DCV) and 0.37 µmol L?1 (DPV). Thorough comparative studies have shown that m‐AgSAE is the best sensor for voltammetric determination of the two model genotoxic compounds because it gives the lowest LQ, is easier to prepare, and its surface can be easily renewed both chemically (by new amalgamation) and/or electrochemically (by imposition of cleaning pulses). The practical applicability of the newly developed methods was verified on model samples of drinking water.  相似文献   

7.
Determination of cysteamine and tryptophan is described by electrochemical methods using p‐aminophenol‐multiwall carbon nanotubes paste electrode. Cysteamine and tryptophan in mixture can each be measured independently from each other with a potential difference of 600 mV. The results showed that the electrocatalytic currents increased linearly with cysteamine and tryptophan concentrations over the ranges 0.5–300 µmol L?1 and 10.0–650 µmol L?1, respectively. The detection limits for cysteamine and tryptophan are found to be 0.14 and 5.9 µmol L?1, respectively. The proposed method is successfully employed for the determination of cysteamine in both capsule and urine samples.  相似文献   

8.
This paper describes the development a novel ruthenium(II) complex‐ZnO/CNTs modified carbon paste electrode (Ru(II)/ZnO/CNTs/CPE) for the electrocatalytic determination of ascorbic acid (AA). The objective of this novel electrode modification was to seek new electrochemical performances for the detection of AA, nicotinamide adenine dinucleotide (NADH) and folic acid (FA). The peak potentials recorded were 170, 500 and 830 mV vs. Ag/AgCl/KClsat for AA, NADH and FA, respectively. The peak currents were linearly dependent on AA, NADH and FA concentrations using square wave voltammetry (SWV) method at the ranges of 0.008–251, 1.0–650, and 3.0–700 µmol L?1, with detection limits of 0.005, 0.5, and 1.0 µmol L?1, respectively.  相似文献   

9.
An array of carbon composite electrodes embedded in a 96 well microtitration plate was fabricated and applied for DPV determination of the environmental pollutant triclosan (5‐chloro‐2‐(2,4‐dichlorophenoxy)‐phenol). For the preparation of composite electrodes, graphite and glassy carbon conductive microparticles were tested in combination with several types of polymers as nonconductive binders. For the measurements, combinations of graphitic carbon particles with polystyrene (C‐PS) and with polycarbonate (C‐PC) were selected. The achieved limit of detection was 0.49 µmol L?1 for C‐PS electrodes and 0.25 µmol L?1 for C‐PC electrodes in the selected optimum medium. The method was successfully applied for practical samples of river water and toothpaste.  相似文献   

10.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

11.
In the present research, the electro oxidation of methanol was investigated by different electrochemical methods at a carbon paste electrode (CPE) modified with bis(salicylaldehyde)‐nickel(II)‐dihydrate complex (Ni(II)‐BS) and reduced graphene oxide (RGO) (which named Ni(II)‐BS/RGO/CPE) in an alkaline solution. This modified electrode showed very efficient activity for oxidation of methanol. It was found that methanol was oxidized by NiOOH groups generated by further electrochemical oxidation of nickel (II) hydroxide on the surface of the modified electrode. The rate constant and electron transfer coefficient were calculated to be 2.18 s?1 and 0.4, respectively. The anodic peak currents revealed a linear dependency with the square root of scan rate. This behaviour is the characteristic of a diffusion controlled process, so the diffusion coefficient of methanol was found to be 1.16×10?5 cm2 s?1 and the number of transferred electron was calculated to be 1. Moreover, differential pulse voltammetry (DPV) investigations showed that the peak current values were proportional to the concentration of methanol in two linear ranges. The obtained linear ranges were from 0.5 to 100.0 µM (R2=0.991) and 400.0 to 1300.0 µM (R2=0.992), and the detection limit was found to be 0.19 µM for methanol determination. Generally, the Ni(II)‐BS/RGO/CPE sensor was used for determination of methanol in an industrial ethanol solution containing 4.0 % methanol.  相似文献   

12.
Composites of gold nanoparticles (Au) electrochemically deposited and different metal phthalocyanines (Co, Ni, Cu, and Fe) were chemically prepared. The composites were used as modifiers for carbon paste electrodes and were used for the determination of morphine in presence of ascorbic acid and uric acid. Central metal atoms of phthalocyanine moiety affected the rate of electron transfer. Thus, the electroactivity of different modifiers were evaluated towards morphine oxidation. Au‐CoPcM‐CPE possessed the highest rate for charge transfer rate in all studied pH electrolytes. Limit of detection was 5.48×10?9 mol L?1 in the range of 4.0×10?7 to 9.0×10?4 mol L?1.  相似文献   

13.
N‐(3,4‐dihydroxyphenethyl)‐3,5‐dinitrobenzamide modified multiwall carbon nanotubes paste electrode was used as a voltammetric sensor for oxidation of penicillamine (PA), uric acid (UA) and tryptophan (TP). In a mixture of PA, UA and TP, those voltammograms were well separated from each other with potential differences of 300, 610, and 310 mV, respectively. The peak currents were linearly dependent on PA, UA and TP concentrations in the range of 0.05–300, 5–420, and 1.0–400 µmol L?1, with detection limits of 0.021, 2.0, and 0.82 µmol L?1, respectively. The modified electrode was used for the determination of those compounds in real samples.  相似文献   

14.
A simple procedure for the simultaneous determination of acetaminophen (AC) and ascorbic acid (AA) by differential pulse voltammetry (DPV) using a carbon nanotube paste electrode exploiting measures in cetylpyridinium bromide (CPB) medium is described. Under the best instrumental parameters of DPV, optimized by means of factorial design, the calibration plots in the range 100.0–700.0 µmol L?1 (r=0.993) and 39.4–146.3 µmol L?1 (r=0.995) with limits of detection of 7.1 and 2.1 µmol L?1, were achieved for AA and AC, respectively. The developed method was successfully applied for the AC and AA determination in pharmaceutical formulations, whose accuracy was attested by comparison with HPLC method.  相似文献   

15.
Mesoporous carbon ceramic SiO2/50 wt % C (SBET=170 m2 g?1), where C is graphite, were prepared by the sol‐gel method. The materials were characterized using N2 sorption isotherms, scanning electron microscopy, and conductivity measurements. The matrix was used as support for the in situ immobilization of Mn(II) phthalocyanine (MnPc) on their surface. XPS was used to determine the Mn/Si atomic ratios of the MnPc‐modified materials. Pressed disk electrodes were prepared with the MnPc‐modified matrix, and tested as an electrochemical sensor for nitrite oxidation. The linear response range, sensitivity, detection limit and quantification limit were 0.79–15.74 µmol L?1, 17.31 µA L µmol?1, 0.02 µmol L?1 and 0.79 µmol L?1, respectively, obtained using cyclic voltammetry. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.7 % for 10 measurements of a solution of 12.63 µmol L?1 nitrite. The sensor employed to determine nitrite in sausage meat, river and lake water samples showed to be a promising tool for this purpose.  相似文献   

16.
《Electroanalysis》2005,17(4):343-347
The adsorptive voltammetric behavior of the gallium‐alizarin red S (ARS) complex in NH4OAc‐HCl buffer at a carbon paste electrode(CPE) was investigated. The results showed that the complex can be adsorbed on the surface of the CPE, yielding one reduction peak at ?0.52 V(vs. SCE), corresponding to the irreversible reduction of the ligand, ARS, bonded in the complex. The optimal experimental conditions include the use of 0.10 mol L?1 ammonium acetate buffer(pH 4.5), 1.0×10?5 mol L?1 ARS, an accumulation potential of ?0.05 V, an accumulation time of 180 s ,a rest time of 10 s, a scan rate of 200 mV s?1and a second‐order derivative linear scan mode. The peak current is proportional to the concentration of gallium(III) over the range 0.02–6.0 μg L?1, with the detection limit of 0.01 μg L?1 for an accumulation time of 180 s. The method was applied to the determination of gallium in food samples with satisfactory results.  相似文献   

17.
Three types of ion‐selective electrodes: PVC membrane, modified carbon paste (CPE), and coated graphite electrodes (CGE) have been constructed for determining paroxetine hydrochloride (Prx). The electrodes are based on the ion pair of paroxetine with sodium tetraphenylborate (NaTPB) using dibutyl phthalate as plasticizing solvent. Fast, stable and potentiometric response was obtained over the concentration range of 1.1×10?5–1×10?2 mol L?1 with low detection limit of 6.9×10?6 mol L?1 and slope of a 56.7±0.3mV decade?1 for PVC membrane electrode, the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 1.2×10?5 mol L?1 and slope of a 57.7±0.6 mV decade?1 for CPE, and the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 8.9×10?6 mol L?1 and slope of a 56.1±0.1 mV decade?1 for CGE. The proposed electrodes display good selectivity for paroxetine with respect to a number of common inorganic and organic species. The electrodes were successfully applied to the potentiometric determination of paroxetine hydrochloride in its pure state, its pharmaceutical preparation, human urine and plasma.  相似文献   

18.
A new composite electrode based on multiwall carbon nanotubes (MWCNT) and silicone‐rubber (SR) was developed and applied to the determination of propranolol in pharmaceutical formulations. The effect of using MWCNT/graphite mixtures in different proportions was also investigated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for electrochemical characterization of different electrode compositions. Propranolol was determined using MWCNT/SR 70 % (m/m) electrodes with linear dynamic ranges up to 7.0 µmol L?1 by differential pulse and up to 5.4 µmol L?1 by square wave voltammetry, with LODs of 0.12 and 0.078 µmol L?1, respectively. Analysis of commercial samples agreed with that obtained by the official spectrophotometric method. The electrode is mechanically robust and presented reproducible results and a long useful life.  相似文献   

19.
Modified screen printed (SPE) and carbon paste electrodes (CPE) with phenanthroline–tetraphenyl borate ionophore [Phen:TPB] were fabricated for the determination of copper(II). The modified electrodes have linear responses over a wide concentration range (1 × 10?6–1 × 10?2 mol·L?1) of copper(II) ion at 25 °C with divalent cationic slopes of 29.85 ± 0.58 and 29.45 ± 0.81 mV·decade?1 and exhibit a detection limit of 1 × 10?6 mol·L?1 for SPE and CPE. The selectivity coefficient was measured using the match potential method in acetate buffer of pH = 4.2. The modified SPE and CPE sensors show high selectivity and sensitivity for determination of copper(II) and also show stable and reproducible response over a period of five and three months for SPE and CPE sensors, respectively. This method can be used for determination of copper(II) in water, soil, plant and fish tissue samples and the results obtained agreed with those obtained with atomic absorption spectrometer (AAS).  相似文献   

20.
The electroanalytical performance of bare glassy carbon electrodes (GCE) for the determination of 1‐aminonaphthalene (1‐AN) and 2‐aminonaphthalene (2‐AN) was compared with GCE modified by a Nafion permselective membrane or multiwalled carbon nanotubes and with other types of carbon‐based materials, carbon film and boron doped diamond. Nafion‐modified GCE gave the highest sensitivity and lowest detection limit (0.4 µmol L?1) for differential pulse voltammetric determination of 1‐AN. Electrochemical impedance spectroscopy gave information about the processes at the electrode surface. Simultaneous determination of 1‐AN and 2‐AN in a mixture at GCE and their determination in model samples of river water is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号