首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for 35Cl+ to more than 6 × 105 cps for 238U+ for 1 μg of trace element per gram of coal sample. Detection limits vary from 450 ng g−1 for chlorine and 18 ng g−1 for sulfur to 9.5 pg g−1 for mercury and 0.3 pg g−1 for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. Figure LA-ICP-IDMS allows direct multi-element determination in powdered coal samples  相似文献   

2.
Epithermal instrumental neutron activation analysis (EINAA) technique in conjunction with anti-coincidence gamma-ray spectrometry (AC) has been applied for the determination of ppm to ppb levels of iodine in biological materials containing high levels of Al, Br, Cl, K, Mn, and Na. Both conventional EINAA-AC and pseudo-cyclic EINAA-AC (PC-EINAA-AC) methods using a combination of Cd and B filters have been developed using Dalhousie University SLOWPOKE-2 reactor (DUSR) facility. The expanded uncertainties (EU), at about 95% confidence level, for iodine in biological materials by EINAA-AC varied between 6 and 10%. The advantages of the non-destructive PC-EINAA-AC method has been successfully demonstrated by analyzing the NIST Pine Needles (SRM 1575) containing a low amount of iodine in presence of high quantities of Mn and other interfering elements where an iodine content of 92.8 μg kg−1 with an EU of 6.1 μg kg−1 and a detection limit of 40 μg kg−1 has been obtained at the end of fourth cycle.  相似文献   

3.
An inductively coupled plasma quadrupole mass spectrometer equipped with an octopole collision/reaction cell was used for the determination of cadmium in oyster tissue samples using isotope dilution inductively coupled plasma mass spectrometry. The oyster samples in question were found to contain Mo and Zr. In our feasibility study on a Cd standard solution (10 μg L−1) containing a matrix of Mo (1000 μg L−1) or Zr (250 μg L−1), the potentially interfering species (MoO+ or ZrO+) present at the analytical mass of cadmium concerned (m/z 111, 112 or 114) was reduced effectively through the use of a mixture of He and H2 as cell gases. The accuracy of the method was validated by the analysis of a matrix-matched certified reference material (CRM) of NIST SRM 1566b. The CRM was analyzed under the standard and He/H2 cell modes. Two isotopic pairs of 114Cd/111Cd and 112Cd/111Cd were selected for quantification purposes. The recoveries of cadmium obtained in the two cell modes were compared with each other. The validated method was applied successfully to the APMP.QM-P5 pilot study for international comparability purposes.  相似文献   

4.
Summary The determination of the antibiotic oxytetracycline (OTC), in pig tissues was investigated by capillary zone electrophoresis (CZE) with a prior solid-phase extraction (SPE) using alkyl-bonded silica and polymeric cartridges. The methodology developed allows determination of OTC in pig kidney, liver and muscle samples with detection limits below maximum residue limit values, and the procedures to extract OTC and clean-up the matrix are simple and reliable. The limit of detection for OTC was 160, 120 and 85 μg kg−1 for kidney, liver and muscle samples, respectively. The average recoveries from spiked samples (200 μg kg−1 and 1600 μg kg−1) were in excess of 63% with coefficients of variation between 2.0 and 9.8%. This method would be useful for routine monitoring of oxytetracycline residues in pig tissues.  相似文献   

5.
A multiresidue method has been developed for the simultaneous determination of sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethoxydiazine, sulfamethylthiazole, sulfamethazine, sulfamonomethoxine, sulfamethoxypyridazine, sulfisoxazole, sulfamethoxazole, sulfadimethoxine and sulfaquinoxaline in natural animal casings by HPLC after solid-phase extraction. The sulfonamides were extracted with acetonitrile and the extract cleaned up with an Oasis MCX SPE cartridge prior to analysis. Separation was on a ZOBAX Eclipse XDB-C8 column using gradient elution with acetonitrile/methanol/0.1% acetic acid. The effect of separation conditions on chromatographic behavior and recovery has been studied. Calibration graphs were linear with very good correlation coefficients (r = 0.9983−0.9996) in the concentration range from 0.02 to 1 μg mL−1. The limits of quantitation (LOQ) for the 13 sulfonamides were in the range of 1.5–2.2 μg kg−1. Decision limits (CCα) and detection capabilities (CCβ) were in the range of 105.2–111.0 and 113.0–120.2 μg kg−1, respectively. The recovery for casings spiked with 1.5–100 μg kg−1 ranged from 65.2 to 85.9%. The relative standard deviations (RSDs) of the sulfonamides for six measurements at 100 μg kg−1 were from 2.2 to 7.7%. The applicability of the method to the analysis of salted swine casings, salted sheep casings and dry casing samples was demonstrated.  相似文献   

6.
An optimized extraction and cleanup method for the analysis of chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC) and tetracycline (TC) in soil is presented. Soil extraction in a pressurized liquid extraction system, followed by extract clean up using solid-phase extraction (SPE) and tetracycline determination by liquid chromatography tandem mass spectrometry (LC-MS/MS) provided appropriate efficiency and reproducibility. Different dispersing agents and solvents for soil extraction and several SPE cartridges for cleanup were compared. The best extraction results were obtained using ethylenediamine tetraacetic acid-treated sand as dispersing agent, and water at 70 °C. The most effective cleanup was obtained using Strata-XTM sorbent in combination with a strong anion exchange cartridge. Recoveries ranged from 71% to 96% and precision, as indicated by the relative standard deviations, was within the range of 8–15%. The limits of quantification (LOQs) by using LC-MS/MS, based on signal-to-noise ratio (S/N) of 10, ranged from 1 μg kg−1 for TC to 5 μg kg−1 for CTC. These results pointed out that this technique is appropriate to determine tetracyclines in soils. Analysis of 100 samples taken in the Valencian Community revealed that, in soil, up to 5 μg kg−1 CTC, 15 μg kg−1 OTC, 18 μg kg−1 TC, and 12 μg kg−1 DC could be detected. Detection of the analytes in several samples, which typify great part of the Spanish agricultural soils, should be outlined as most important result of this study. Electronic supplementary material  The online version of this article (doi: ) contains supplementary material, which is available to authorized users.  相似文献   

7.
The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 μg L−1 depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below μg L−1 level in natural water. It is based on solid-phase extraction using TiO2 nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 ± 2.8 ng kg−1 (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3–4% k = 2 for a cadmium content of around 100 ng kg−1). We applied the developed method to the groundwater and wastewater samples ERM-CA615 and BCR-713, respectively, and results agreed with certificate values within uncertainty statements.  相似文献   

8.
This study describes the development and validation of a time-resolved fluoroimmunoassay (TR-FIA) for screening ractopamine (RAC) in swine tissue. The method is based on the direct competitive-type immunoassay using europium-labeled anti-RAC monoclonal antibody as a tracer and RAC–ovalbumin as a solid-phase antigen. When RAC was spiked at levels of 1–10 μg kg−1, recoveries ranged from 88.2 to 118.5% for swine liver and muscle with coefficients of variation from 7.1 to 20.5%. The detection limit was 0.1 μg kg−1. The proposed TR-FIA method was applied to the determination of RAC in an actual residue study and the applicability was confirmed by liquid chromatography–tandem mass spectrometry.  相似文献   

9.
Fumonisins B1 (FB1) and fumonisin B2 (FB2) are the main members of a family of mycotoxins produced by Fusarium verticillioides, Fusarium proliferatum, and other fungi species of the section Liseola. The present work shows the results of comparative studies using two different procedures for the analysis of fumonisins in maize and maize-based samples. The studied analytical methods involve extraction with methanol/water, dilution with PBS, and clean-up through immunoaffinity columns. Two reagents (o-phthaldialdehyde and naphthalene-2,3-dicarboxaldehyde) were studied for formation of fluorescent derivatives. The separation and identification were carried out by high-performance liquid chromatography with fluorescence detection. The optimized method for analysis of fumonisins in maize involved extraction with methanol/water (80:20), clean-up with an immunoaffinity column, and derivatization with naphthalene-2,3-dicarboxaldehyde (NDA). The limit of detection was 20 μg kg−1 for FB1 and 15 μg kg−1 for FB2. Recoveries of FB1 and FB2 ranged from 79% to 99.6% for maize fortified at 150 μg kg−1 and 200 μg kg−1, respectively, with within-day RSDs of 3.0 and 2.7%. The proposed method was applied to 31 samples, and the presence of fumonisins was found in 14 samples at concentrations ranging from 113 to 2,026 μg kg−1. The estimated daily intake of fumonisins was 0.14 μg kg−1 body weight per day.  相似文献   

10.
An online analytical system using ion chromatography (IC) followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the separate determination of I and IO3 in aqueous solutions with a detection limit 0.1–1 μg 1/1. The total iodine concentration was also directly determined by ICP-MS. Iodine in several environmental samples (i.e., rain, river water, brine, and soil solution) was successfully determined with information on its chemical form. The release of I into soil solution with decreasing Eh was observed in an incubation experiment with flooded soil. An iodine form other than I and IO3 was observed in several environmental samples.  相似文献   

11.
Summary The fluorogenic reagent 2-naphthyloxycarbonyl chloride (NOC-Cl) has been used for the automated precolumn derivatization of biogenic amines (BAs) at ambient followed by liquid-chromatographic separation of the derivatives formed. For optimized derivatization samples in 0.5 M borate buffer (pH 9.0) were derivatized with 5 mM NOC-Cl in acetonitrile (MeCN) for 3 minutes. Excess of reagent was scavenged by addition of 20 mM glycine in water. For HPLC a Superspher? RP-18e column and gradient elution using 0.1 M sodium acetate buffer (pH 4.4) and MeCN were used. The NOC-derivatives were detected by fluorescence at an emission wavelength of 335 nm at an excitation wavelength of 274 nm. This method allows the detection of BAs (2-phenylethylamine, putrescine, histamine, cadaverine, tyramine, spermidine, spermine) found in food and beverages (fruit juices, wines, various vinegars, fermented cabbage juice, and salmon). Detection limit of BAs are approximately 49–113 μg kg−1 with the exception of histamine (747 μg kg−1) (injected amounts: 18–41 pg histamine 267 pg), at a signalto-noise ratio of 3:1. The limits of determination are approximately 82–189 μg kg−1 (histamine 1245 μg kg−1) at a signal-to-noise ratio of 5:1. The correlation coefficients of linearity are 0.9910–0.9976. Recoveries from different matrices range from 65 to 109%, depending on the sample investigated. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996.  相似文献   

12.
Summary A high-performance thin-layer chromatographic method based on solid-phase extraction has been developed for the qualitative determination of seven quinolones (enrofloxacin, ciprofloxacin, danofloxacin, norfloxacin, flumequine, oxolinic acid and nalidixic acid) in pork muscle. After preparation of the samples by extraction and clean-up by solid-phase extraction on reversed-phase cartridges, extracts were spotted and eluted on silica gel plates. The plate is first inspected under UV illumination at 312 nm, then sprayed with terbium chloride solution and again monitored under 312 nm UV. The method has been validated to a level of 15 μg kg−1 for enrofloxacin, ciprofloxacin, danofloxacin, norfloxacin and 5 μg kg−1 for flumequin, oxolinic acid and nalidixic acid.  相似文献   

13.
Lead concentration in soils has been measured in Vetagrande, an old mining town located at the state of Zacatecas in México. Eighty nine soils samples were analyzed using Energy Dispersive X-ray Fluorescence. The lead concentrations were treated with the Kriging method in order to estimate the lead concentration distribution in the studied area. Pb levels in soils were from 8 to 7730 μg kg−1, where 28.1% of soil samples have less than 400 μg kg−1, 71.9% is above 400 μg kg−1 which is the maximum level recommended by the EPA for residential use of soil. Lead concentration measured around public sites represent a risk of lead intake in the population.  相似文献   

14.
The National Institute of Standards and Technology, the U.S. Food and Drug Administration, Center for Drug Evaluation and Research and Center for Food Safety and Applied Nutrition, and the National Institutes of Health, Office of Dietary Supplements, are collaborating to produce a series of Standard Reference Materials (SRMs) for dietary supplements. A suite of ephedra materials is the first in the series, and this paper describes the acquisition, preparation, and value assignment of these materials: SRMs 3240 Ephedra sinica Stapf Aerial Parts, 3241 E. sinica Stapf Native Extract, 3242 E. sinica Stapf Commercial Extract, 3243 Ephedra-Containing Solid Oral Dosage Form, and 3244 Ephedra-Containing Protein Powder. Values are assigned for ephedrine alkaloids and toxic elements in all 5 materials. Values are assigned for other analytes (e.g., caffeine, nutrient elements, proximates, etc.) in some of the materials, as appropriate. Materials in this suite of SRMs are intended for use as primary control materials when values are assigned to in-house (secondary) control materials and for validation of analytical methods for the measurement of alkaloids, toxic elements, and, in the case of SRM 3244, nutrients in similar materials.  相似文献   

15.
Two independent liquid chromatography inductively coupled plasma-mass spectrometry (LC/ICP-MS) methods for the separation of arsenic species in urine have been developed with quantification by standard additions. Seven arsenic species have been quantified in a new NIST frozen human urine Standard Reference Material (SRM) 2669 Arsenic Species in Frozen Human Urine, Levels 1 and 2. The species measured were: arsenite (As(III)), arsenate (As(V)), monomethylarsonate (MMA), dimethylarsinate (DMA), arsenobetaine (AB), arsenocholine (AC), and trimethylarsine oxide (TMAO). The purity of each arsenic standard used for quantification was measured as well as the arsenic species impurities determined in each standard. Analytical method limits of detection (L D) for the various species in both methods ranged from 0.2 to 0.8 μg L−1 as arsenic. The results demonstrate that LC/ICP-MS is a sensitive, reproducible, and accurate technique for the determination of low-level arsenic species in urine. Measurements of the arsenic species 3 years after initial production of the SRM demonstrate the stability of the arsenic species in the urine reference material.  相似文献   

16.
The determination of total deoxyribonucleic acid (DNA) concentration is of great importance in many biological and bio-medical analyses. The quantification of DNA is traditionally performed by UV spectroscopy; however the results can be affected greatly by the sample matrix. The proposed method quantifies phosphorus in digested calf thymus DNA and human DNA by high performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICP-MS). The method presented showed excellent baseline separation between all four DNA mono-nucleotides and 5′UMP. The ability of LC-ICP-MS to provide an internal check that only DNA derived phosphorus was counted in the assay was demonstrated by establishing a mass balance between the total phosphorous signal from undigested DNA and that from the speciated DNA. Column recoveries ranging from 95% to 99% for phosphorus resulted in a mass balance of 95% ± 0.5% for standard nucleotides, determined by LC-ICP-MS, compared to total DNA determined by flow injection coupled to ICP-MS (FI-ICP-MS). The method for quantification was validated by analysis of NIST SRM 2,372; a total speciated DNA recovery of 52.1 ng/μL, compared with an expected value of 53.6 ng/μL, was determined by external calibration. From repeat measurements, a mass balance of 97% ± 0.5% for NIST DNA was achieved. The method limits of detection for individual nucleotides were determined between 0.8 and 1.7 μg L−1 (31P) for individual nucleotides by LC-ICP-MS, and 360 ng L−1 for 5′AMP by direct nebulisation.  相似文献   

17.
The formation of a complex with 2-(5-brom-2-pyridylazo)-5-(diethylamino)-phenol (5-Br-PADAP) and cloud point extraction have been applied to the preconcentration of cadmium followed by its determination by graphite furnace atomic absorption spectrometry (GFAAS) using octylphenoxypolyethoxyethanol (TritonX-114) as surfactant. The chemical variables affecting the separation were optimized. At pH 7.0, preconcentration of only 10 mL of sample in the presence of 0.05% TritonX-114 and 2.5 × 10−6 M 5-Br-PADAP enabled the detection of 0.04 μg/L cadmium. The enrichment factor was 21 for cadmium. The regression equation was A = 0.0439C(μg/L) + 7.2 × 10−3. The correlation coefficient was 0.9995. The precision for 10 replicate determinations at 10 μg/L Cd was 2.7% relative standard deviation (RSD). The proposed method has been applied to the determination of cadmium in water samples. The text was submitted by the authors in English.  相似文献   

18.
A sensitive and effective method for simultaneous determination of triazolopyrimidine sulfonamide herbicide residues in soil, water, and wheat was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry. The four herbicides (pyroxsulam, flumetsulam, metosulam, and diclosulam) were cleaned up with an off-line C18 SPE cartridge and detected by tandem mass spectrometry using an electrospray ionization source in positive mode (ESI+). The determination of the target compounds was achieved in <2.0 min. The limits of detection were below 1 μg kg−1, while the limits of quantification did not exceed 3 μg kg−1 in different matrices. Quantitation was determined from calibration curves of standards containing 0.05–100 μg L−1 with r 2 > 0.997. Recovery studies were conducted at three spiked levels (0.2, 1, and 5 μg kg−1 for water; 5, 10, and 100 μg kg−1 for soil and wheat). The overall average recoveries for this method in water, soil, wheat plants, and seeds at three levels ranged from 75.4% to 106.0%, with relative standard deviations in the range of 2.1–12.5% (n = 5) for all analytes.  相似文献   

19.
Summary An ion-chromatographic procedure is described for the determination of selenium (VI) at μg L−1 level in the presence of anions and heavy metal ions. Maximum permissible concentrations and effects from each interfering substance were investigated for the Se concentration range 12.5–1,000 μg L−1. The method, optimized for the detection of SeO 4 2− , gives results suitable for speciation analysis. Total selenium can be determined after complete conversion to selenate ion by oxidation with KMnO4. The detection limit of selenium is 4.8 μg L−1 (0.96 ng for 200 μL sample). Paper presented at the 41st Pittsburgh Conference, New York, March 5–9, 1990.  相似文献   

20.
A liquid chromatographic method for the determination of meloxicam in serum has been developed. The technique includes a solid phase extraction of the serum samples on [poly (divinylbenzeneco-N-vinylpyrrolidone)] as a solid phase extraction sorbent. After conditioning, the cartridge was loaded with 1 mL of acidified serum containing an internal standard. Elution was carried out using 1 mL of water-acetonitrile (φ r = 1: 1) mixture. After evaporation of the eluate to dryness and reconstitution of the residue with 0.1 mL of methanol, the samples were analyzed on a Symmetry C18 column. Mobile phase consisted of 1 % aqueous acetic acid/THF/acetonitrile (φ r = 60: 30: 10) + 0.1 mL of 1-octane sulfonic acid. Detection was carried out using a photodiode array detector. Full validation of the proposed method is provided. Linearity of the method was proven over the range of 0.01–10 φg mL−1 of meloxicam. Meloxicam assay was accurate and reliable with average intra- and inter-day precisions lower than 5.0 % and the intra- and inter-day accuracy higher than 97 %. Limits of detection (LOD) and quantitation (LOQ) found were 0.003 μg mL−1 and 0.01 μg mL−1, respectively. The proposed method was successfully utilized to quantify meloxicam in serum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏