共查询到20条相似文献,搜索用时 937 毫秒
1.
介绍了一种全正色散宽光谱被动锁模掺镱光纤激光器,利用非线性偏振旋转技术实现全正色散掺镱光纤激光器的被动锁模.当泵浦功率输出为500mW时,激光脉冲输出功率大于139mW,重复频率约为28.1MHz,脉冲宽度为3.8ps.为了进一步研究全正色散光纤激光器的宽光谱输出特性,在腔内熔接50m单模光纤,同时去除双折射滤波片,在泵浦功率为500mW时,观察到稳定锁模单脉冲耗散孤子,光谱范围为1 005~1 140nm,输出激光脉冲最大平均功率为90mW,重复频率为3.58MHz,脉冲宽度为519ps. 相似文献
2.
运用非线性偏振旋转效应实现了一种掺铥锁模多波长光纤激光器.采用环形腔结构,以1 565nm半导体光源为泵浦源,3m长掺铥光纤为增益介质.利用非线性偏振旋转效应进行滤波.当泵浦功率在800mW时,通过调节光纤偏振控制器,激光器出现了被动锁模状态的脉冲输出,脉冲重复频率为3.178MHz,脉冲宽度为617ps.进一步增加泵浦功率,激光器进入多波长输出的工作状态.调节偏振控制器在室温下得到1~5个稳定的波长激光输出,边摸抑制比为40~60dB. 相似文献
3.
在一种掺镱(Yb3+)光纤锁模激光器中。谐振腔采用近“8”字形环形结构,并巧妙地引入半导体可饱和吸收镜(SESAM),腔内引入起偏器和偏振控制器,利用非线性偏振旋转的被动锁模机理,结合SESAM慢可饱和吸收体的自启动作用,在极低的泵浦功率下,实现了稳定的调Q脉冲输出和锁模输出。当泵浦功率为18 mW时,调Q脉冲重复频率为16 kHz,脉冲宽度4 μs,光谱宽度为2.34 nm。当泵浦功率为60 mW时,实现了激光器连续锁模,输出功率8 mW,重复频率20 MHz,光谱宽度3.54 nm,脉宽在ps和亚ps量级,而且在调整偏振控制器的角度时,观察到了波长的调谐现象,调谐范围为1 028~1 530 nm。 相似文献
4.
设计了基于多模干涉效应锁模的掺铒光纤激光器,利用渐变折射率多模光纤实现了锁模脉冲输出。通过控制泵浦功率,调节腔内偏振控制器,实验获得中心波长为1528 nm的展宽脉冲,3 dB带宽为37.2 nm,脉冲宽度为973.2 fs。在腔外进行色散补偿,将展宽脉冲的脉冲宽度压缩至280.1 fs。此外,通过提高总泵浦功率至961.1 mW并微调偏振控制器,获得了色散管理孤子分子脉冲输出,调制周期为0.32 nm,对应的脉冲间隔为24.1 ps。实验采用多模光纤内置在偏振控制器中的锁模结构,突破了对多模光纤长度的限制,激光器结构紧凑,具有出色的稳定性。 相似文献
5.
6.
7.
8.
提出了主动锁模联合非线性偏振旋转光纤激光器中基于偏振控制器的脉宽可调平顶光脉冲生成技术.光纤激光器由主动锁模部分和一根掺Bi的高非线性光纤联合两个偏振控制器及光纤检偏器构成的非线性偏振旋转结构组成.分析了该实验装置在不同状态下的工作机制,通过调节激光器中的两个偏振控制器,实验获得了10GHz的脉宽可调平顶光脉冲,脉宽调节范围在12~19ps之间,调节激光腔中的宽带滤波器,可在不同波长处获得平顶光脉冲.实验表明:输出的平顶光脉冲性能稳定,边模抑制比为65dB,定时抖动145fs. 相似文献
9.
10.
11.
Guided-Wave Two-Dimensional Acousto-Optic Scanner Using Proton-Exchanged Lithium Niobate Waveguide 总被引:1,自引:0,他引:1
Two-dimensional scanning of a 0.6328 mum guided-light beam has been realized using noncolinear acousto-optic (AO) coplanar Bragg diffraction together with colinear AO guided-mode to substrate radiation-mode conversion in a Z-cut Xpropagation LiNbO3 proton-exchanged (PE) waveguide. The two surface acoustic (SAW) waves utilized are at the center frequencies of 500 and 200 MHz, propagating in the Y and X axes, respectively. Two-dimensional scanning of approximately 720 resolvable light beam spots, namely, 18 40 (horizontal vertical) scanning, has been demonstrated using a light beam of 1.0 mm aperture. The total number of resolvable beam spots can be greatly increased from 720 by simply utilizing SAW transducers of larger bandwidth and a light beam of greater aperture. It should also be possible to significantly increase the diffraction efficiency from 3 % by optimizing the parameters of the PE waveguide and the SAWs. 相似文献
12.
A simple technique of pulse compression, based on the linear chirp compensation of self-phase modulation (SPM) spectra in dispersion shifted fibers, is demonstrated. The optimization procedure is carried out, for a short span of a single-mode fiber, using a parabolic law, which describes the behavior of the squared output pulse width versus the pump peak power in the case of Gaussian pulses. The experimental results give a minimum pulse duration of 233 fs, which is in good agreement with the model. Shorter and coherent pulses, down to 90 fs, have been obtained by inserting an interference filter at the optical output. 相似文献
13.
S. G. Nedel’ko M. A. Krysyuk A. L. Apanasenko L. N. Lymarenko Z. T. Moroz 《Journal of Applied Spectroscopy》1997,64(1):55-61
Results of a study of the effect of γ-radiation on the spectral luminescence properties of cadmium tungstate crystals doped
with silver, bismuth, and molybdenum cations are presented. Spectral characteristics of the nondnnnoped crystals are briefly
described. Absorption and photo and X-ray luminescence spectra of the crystals taken before and after exposure to γ-radiation
(5.5·104 Gy) are compared. It is found that the spectral characteristics of the crystals doped with silver, bismuth, and molybdenum
cations do not change markedly after the exposure. The relation between the type of impurity-induced defects, individual characteristics
of the impurity cations, and the character of the effect of γ-radiation on the spectral luminescence properties of impure
crystals is analyzed (preliminarily).
Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 64, No. 1, pp. 55–60, January–February, 1997. 相似文献
14.
The Shanghai Synchrotron Radiation Facility(SSRF)booster ring,a full energy injector for the storage ring,is deigned to accelerate the electron beam energy from 150MeV to 3.5GeV that demands high extraction efficiency at the extraction energy with low beam loss rate when electrons are ramping.Closed orbit distortion(COD)caused by bending magnet field uniformity errors which affects the machine performance harmfully could be effectively reduced by bending magnet location sorting.Considering the affections of random errors in measurement,both ideal sorting and realistic sorting are studied based on measured bending magnet field uniformity errors and one reasonable combination of bending magnets which can reduce the horizontal COD by a factor of 5is given as the final installation sequence of the booster bending magnets in this paper. 相似文献
15.
16.
A multi-conjugate adaptive optics (MCAO) can offer a possibility of widening field of view (FOV) characterized by the isoplanatic angle, and the choose of conjugate height becomes a basic problem for MCAO, which influences the size of iosplanatic angle. Considering the application of lidar, the isoplanatic angle's expressions of two deformable mirrors (DMs) MCAO for uplink and downlink are deduced. The effects of conjugate heights for dual-conjugate AO are thoughtfully discussed, and the isoplanatic angles are further analyzed. The results show that the isopanatic angle varies with the conjugate height and reaches the maximum as the conjugate height is at the optimal altitude. Moreover, the optimal conjugate height changes with the propagation distance. 相似文献
17.
Due to the limit of response speed of the present single-photon detector, the code rate is still too low to come into practical use for the present quantum key distribution (QKD) system.A new idea is put up to design a quick single-photon detector.This quick single-photon detector is composed of a multi-port optic-fiber splitter and many avalanche photo diodes (APDs).Au of the ports with APDs work on the time division and cooperate with a logic discriminating and deciding unit driven by the clock signal.The operation frequency lies on the number N of ports, and can reach N times of the conventional single-photon detector.The single-photon prompt detection can come true for high repetition-rate pulses.The applying of this detector will largely raise the code rate of the QKD, and boost the commercial use. 相似文献
18.
We measure the waveform and phase curves of short optical pulses before and after transmission over different lengths of fibers by use of the pulse analyzer with the frequency-resolved optical gating (FROG),and numerically simulate pulse evolution under the experimental conditions.The nonlinear coefficient of the fiber is given by comparing the experimental results with the numerical ones.Difference between the experiment and numerical simulation is analyzed. 相似文献
19.
Resonance scattering of elastic spherical shell and cylindrical shell while the surrounding fluid medium has absorption is studied. The normal mode solution derived using exact elastic theory and the separation of variables is still applicable. However, the scattering form function has to be modified for the absorbing medium, otherwise the unreasonable result would be obtained. The backscattering form function in the absorbing medium is redefined, and the form function of elastic spherical and cylindrical shell with vacuum or solid matter filled is calculated in various absorption conditions. The results show that the absorption of surrounding fluid leads to notable attenuation of the coincidence resonances in the mid-frequency, but it has a little influence on the low-frequency resonance scattering induced by the filler inside the shell. 相似文献
20.
A versatile and low-cost single-beam self-referenced phase-sensitive surface plasmon resonance(SPR)sensing system with ultra-high resolution performance is presented.The system exhibits a root-mean-square phase fluctuation of ±0.0028.over a period of 45 min.i.e.a resolution of±5.2×10-9 refractive index units.The enhanced performance has been achieved through the incorporation of three design elements:a true single-beam configuration enabling complete self-referencing so that only the phase change associated with SPR gets detected,a differential measurement scheme to eliminate spurious signals not related to the sensor response,and the elimination of retardation drifts by incorporating temperature stabilization in the liquid crystal phase modulato .Our design should bring the detection sensitivity of non-labeling SPR biosensing closer to that achievable by conventional fluorescence-based techniques. 相似文献