首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
This study demonstrates a miniaturized integrated glucose biosensor based on a carbon microbeads entrapped by glucose oxidase (GOx) immobilized on poly (N-isopropylacrylamide) (pNIPAm) microgels. Determined by the Lowry protein assay, the pNIPAm microgel possesses a high enzyme loading capacity of 31?mg/g. The pNIPAm GOx loaded on the microgel was found to maintain a high activity of approximately 0.140?U determined using the 4-aminoantipyrine colorimetric method. The integrated microelectrochemical cell was constructed using a microcentrifuge vial housing packed with (1:1, w/w) carbon entrapped by pNIPAm GOx microgels, which played the dual role of the microbioreactor and the working electrode. The microcentrifuge vial cover was used as a miniaturized reference electrode and an auxiliary electrode holder. The device can work as biosensor, effectively converting glucose to H2O2, with subsequent amperometric detection at an applied potential of ?0.4?V. The microelectrochemical biosensor was used to detect glucose in wide linear range from 30?µM to 8.0?mM, a low detection limit of 10?µM, a good linear regression coefficient (R2) of 0.994, and a calibration sensitivity of 0.0388?µA/mM. The surface coverage of active GOx, electron transfer rate constant (ks), and Michaelis–Menten constant (KMapp) of the immobilized GOx were 4.0?×?10?11?mol/cm2, 5.4?s?1, and 0.086?mM, respectively. To demonstrate the applicability and robustness of the biosensor for analysis of high sample matrix environment, glucose was analyzed in root beer. The microelectrochemical device was demonstrated for analysis of small sample (<50?µL), while affording high precision and fast signal measurement (≤5?s).  相似文献   

2.
For the first time silicon nitride (Si3N4) nanoparticles was used for preparation electrochemical biosensor. GOx immobilized on the Si3N4 nanoparticles exhibits facile and direct electrochemistry. The surface coverage and heterogeneous electron transfer rate constant (ks) of immobilized GOx were 6.3×10?13 mol cm?2 and 47.4±0.3 s?1. The sensitivity, linear concentration range and detection limit of the biosensor for glucose detection were 38.57 µA mM?1 cm?2, 25 µM to 8 mM and 6.5 µM, respectively. This biosensor also exhibits good stability, reproducibility and long life time. These indicate Si3N4 nanoparticles is good candidate material for construction of third generation biosensor and bioelectronics devices.  相似文献   

3.
A simple glucose biosensor has been developed based on direct electrochemistry of glucose oxidase (GOx) immobilized on the reduced graphene oxide (RGO) and β‐cyclodextrin (CD) composite. A well‐defined redox couple of GOx appears with a formal potential of ~?0.459 V at RGO/CD composite. A heterogeneous electron transfer rate constant (Ks) has been calculated for GOx at RGO/CD as 3.8 s?1. The fabricated biosensor displays a wide response to glucose in the linear concentrations range from 50 µM to 3.0 mM. The sensitivity and limit of detection of the biosensor is estimated as 59.74 µA mM?1 cm?2 and 12 µM, respectively.  相似文献   

4.
A novel amperometric glucose biosensor based on layer‐by‐layer (LbL) electrostatic adsorption of glucose oxidase (GOx) and dendrimer‐encapsulated Pt nanoparticles (Pt‐DENs) on multiwalled carbon nanotubes (CNTs) was described. Anionic GOx was immobilized on the negatively charged CNTs surface by alternatively assembling a cationic Pt‐DENs layer and an anionic GOx layer. Transmission electron microscopy images and ζ‐potentials proved the formation of layer‐by‐layer nanostructures on carboxyl‐functionalized CNTs. LbL technique provided a favorable microenvironment to keep the bioactivity of GOx and prevent enzyme molecule leakage. The excellent electrocatalytic activity of CNTs and Pt‐DENs toward H2O2 and special three‐dimensional structure of the enzyme electrode resulted in good characteristics such as a low detection limit of 2.5 μM, a wide linear range of 5 μM–0.65 mM, a short response time (within 5 s), and high sensitivity (30.64 μA mM?1 cm?2) and stability (80% remains after 30 days).  相似文献   

5.
Co3O4/graphene oxide (GO) nanocomposites were successfully prepared by a depositing‐decomposition method. The as‐prepared samples were characterized by scanning electron microscopy (SEM) and Raman spectroscopy. Cyclic voltammetry (CV) was used to evaluate the electrochemical response of a glass carbon electrode (GCE) modified with Co3O4/GO nanocomposite towards glucose. Compared with the Co3O4/GCE, the Co3O4/GO/GCE exihibits higher electrocatalytic activity due to the synergistic effects of electrocatalytic ability of Co3O4 and large surface of GO. The Co3O4/GO/GCE was applied for glucose detection in alkaline solution. The linear current response range of glucose on Co3O4/GO/GCE covered the range from 9 × 10?5 to 6.03 × 10?3 M, with a detection limit of 5.2 × 10?7 M (S/N = 3).  相似文献   

6.
An effective, stable enzymatic glucose biosensor was fabricated on a glassy carbon electrode (GCE) surface using simple multicomposite materials (MCM): a solution of prepared poly(diallyldimethylammonium chloride)‐capped gold nanoparticles‐nickel ferrite particles‐carbon nanotubes‐chitosan (PDDA‐AuNPs‐NiFe2O4‐CNTs‐CHIT), electropolymerization of poly(o‐phenylenediamine) (PoPD) and immobilization of glucose oxidase (GOx). Biocompatibility and synergy of the MCM enhanced the immobilization and the reaction of GOx and as well as the electron transfer from an oxidation reaction of hydrogen peroxide in the system. The NiFe2O4 was synthesized by co‐precipitation and calcined at 700 °C. Characterization was carried out by field emission scanning electron microscopy (FE‐SEM), energy‐dispersive X‐ray spectroscopy (EDX), Fourier transform infrared spectroscopy (FTIR) and X‐ray diffraction (XRD) which presented both tetrahedral and octahedral metal stretching with a cubic NiFe2O4 crystal phase. The GOx/PoPD/MCM/GCE yielded a 0.77 s?1 charge transfer rate constant (Ks), a 2.28×10?6 cm2 s?1 diffusion coefficient value (D), a 0.21 mm2 electroactive surface area (Ae) and a 1.93×10?8 mol cm?2 surface concentration ( ) as determined by cyclic voltammetry. The modified electrode showed a durable operation time (n=97, more than 50 % I), repeatability (%RSD=0.38, n=10), reproducibility (%RSD=1.60, n=10), high sensitivity (853.07 μA mM?1 cm?2), selectivity without effects of electroactive species (aspirin, uric acid, caffeine, cholesterol, ascorbic acid and dopamine) and two linear ranges from 0.5 to 10 μM (R2=0.998) and 10 to 15,000 μM (R2=0.991) with a low detection limit (0.35 μM, S/N=3). Its Michaelis‐Menten constant (Km) was calculated as 93.51 μM with 46.30 μA maximum current (Imax). This proposed simple method was successfully applied for glucose determination in human blood samples.  相似文献   

7.
3D macroporous TiO2 inverse opals have been derived from a sol‐gel procedure using polystyrene colloidal crystals as templates. EDS and SEM showed a face‐centered cubic (FCC) structure TiO2 inverse opal was obtained. Glucose oxidase (GOx) was successfully immobilized on the surface of indium‐tin oxide (ITO) electrode modified by TiO2 inverse opal (TiO2(IO)). Electrochemical properties of GOx/TiO2(IO)/ITO electrode were characterized by using the three electrodes system. The result of cyclic voltammetry showed that a couple of stable and well‐defined redox peaks for the direct electron transfer of GOx in absence of glucose, and the redox peak height enhanced in presence of 0.1 μM glucose. Compare with the ordinary structured GOx/TiO2/ITO electrode, inverse opal structured GOx/TiO2(IO)/ITO electrode has a better respond to the glucose concentration change. Under optimized experimental conditions of solution pH 6.8 and detection potential at 0.30 V versus saturated calomel electrode (SCE), amperometric measurements were performed. The sensitivity and the detection limit of glucose detection was 151 μA cm?2 mM?1 and 0.02 μM at a signal‐to‐noise ratio of 3, respectively. The good response was due to the good biocompatibility of TiO2 and the large effective surface of the three‐dimensionally ordered macroporous structure.  相似文献   

8.
Cationic iron (III) tetrakis-5, 10, 15, 20-(N-methyl-4-pyridyl) porphyrin (FeIIITMPyP) was intercalated into layered semiconductor KNb3O8 by ion-exchange method. The target product was characterized by XRD, Fourier transform infrared, UV–vis, and TGA. FeIIITMPyP forms an inclined monolayer between Nb3O8 ? nanosheets and endues the nanocomposite with excellent electrochemical catalytic activities. The target nanocomposite modified glass carbon electrode shows good electrocatalytic activities for the oxidation of ascorbic acid (AA); the catalytic mechanism was proposed. Differential pulse voltammetric technique was used for detection of AA in neutral aqueous solution; a detection limit of 4.2?×?10?5 M was obtained, and the modified electrode showed good reproducibility in electrochemical detection.  相似文献   

9.
In this research a novel osmium complex was used as electrocatalyst for electroreduction of oxygen and H2O2 in physiological pH solutions. Electroless deposition at a short period of time (60 s), was used for strong and irreversible adsorption of 1,4,8,12‐tetraazacyclotetradecane osmium(III) chloride (Os(III)LCl2) ClO4 onto single‐walled carbon nanotubes (SWCNTs) modified GC electrode. The modified electrode shows a pair of well defined and reversible redox couple, Os(IV)/Os(III) at wide pH range (1–8). The glucose biosensor was fabricated by covering a thin film of glucose oxidase onto CNTs/Os‐complex modified electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The fabricated biosensor shows high sensitivity, 826.3 nA μM?1cm?2, low detection limit, 56 nM, fast response time <3 s and wide calibration range 1.0 μM–1.0 mM. The biosensor has been successfully applied to determination of glucose in human plasma. Because of relative low applied potential, the interference from electroactive existing species was minimized, which improved the selectivity of the biosensor. The apparent Michaelis‐Menten constant of GOx on the nanocomposite, 0.91 mM, exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this glucose biosensor.  相似文献   

10.
An exploration of gold nanoparticles–bacterial cellulose nanofibers (Au‐BC) nanocomposite as a platform for amperometric determination of glucose is presented. Two enzymes, glucose oxidase (GOx) and horseradish peroxidase (HRP) were immobilized in Au‐BC nanocomposite modified glassy carbon electrode at the same time. A sensitive and fast amperometric response to glucose was observed in the presence of electron mediator (HQ). Both of GOx and HRP kept their biocatalytic activities very well in Au‐BC nanocomposite. The detection limit for glucose in optimized conditions was as low as 2.3 µM with a linear range from 10 µM to 400 µM. The biosensor was successfully applied to the determination of glucose in human blood samples.  相似文献   

11.
In this study, a new procedure for the fabrication of biosensors was developed. The method is based on the covalent attachment of nitrophenyl groups to the electrode surface via diazonium salt reaction followed by their conversion to amine moieties through electrochemical reduction and electrostatic layer-by-layer (LbL) assembly technique. In this procedure, highly stable iron oxide (Fe3O4) nanoparticles (IONPs), chitosan (CHIt), GOx, and Nile blue (NB) were assembled on the surface of aminophenyl modified glassy carbon electrode (AP/GCE) by LbL assembly technique. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the interfaces. The surface coverage of the active GOx and Michaelis–Menten constant (K M) of the immobilized GOx were Γ?=?3.38?×?10?11 mol cm?2 and 2.54 mM, respectively. The developed biosensor displayed a well-defined amperometric response for glucose determination with high sensitivity (8.07 μA mM?1) and low limit of detection (LOD) of 19.0 μM. The proposed approach allows simple biointerface regeneration by increasing pH which causes disruption of the ionic interactions and release of the electrostatic attached layers. The biosensor can then be reconstructed again using fresh enzyme. Simple preparation, good chemical and mechanical stabilities, and easy surface renewal are remarkable advantages of the proposed biosensor fabrication procedure.  相似文献   

12.
An ethanol biosensor based on alcohol dehydrogenase (ADH) attached to Au seeds decorated on magnetic nanoparticles (Fe3O4@Au NPs) is presented. ADH was immobilized on Fe3O4@Au NPs, which were subsequently fixed by a magnet on a carbon paste electrode modified with 5 % (m : m) MnO2. Optimum conditions for the amperometric determination of ethanol with the biosensor were as follows: working potential +0.1 V (vs. Ag/AgCl); supporting electrolyte: 0.1 M phosphate buffer solution at pH 6.8 containing 0.25 mM of the coenzyme (NAD+); working electrode: carbon paste with magnetically attached Fe3O4@Au NPs (0.012 mg ? cm?2 electrode area) with immobilized alcohol dehydrogenase (120 units per cm2 of electrode area). Linearity between signal and concentration was found for the range from 0.1 to 2.0 M ethanol (r2=0.995) with a detection limit of 0.07 M, a sensitivity of 0.02 µA ? mM?1 ? cm?2, a reproducibility of 4.0 % RSD, and a repeatability of 2.7 % RSD. The results for the determination of ethanol in alcoholic beverages showed good agreement with gas chromatography (GC) with recovery of 96.0 – 108.8 %.  相似文献   

13.
We have prepared a glassy carbon electrode modified with poly-2,6-pyridinedicarboxylic acid and with magnetic Fe3O4 nanoparticles. This modification enhances the effective surface area and the electrocatalytic oxidation of nicotinamide adenine dinucleotide (NADH) in addition to providing positively charged groups for electrostatic assembly of the phosphate group of NADH. The modified electrode responds linearly to NADH in the range from 5?×?10?8 to 2.5?×?10?5?M and gives a lower detection limit of 1?×?10?8?M. It displays satisfactory selectivity and reproducibility. The sensor was applied to rapid screening of plant extracts for their antioxidant properties.
Figure
Poly-2,6-pyridinedicarboxylic acid (PDC) was fabricated by electropolymerizing 2,6-pyridinedicarboxylic acid with cyclic voltammetry (CV) on the glassy carbon electrode (GCE) surface. The magnetic Fe3O4 nanoparticles treated with aminopropyltriethoxysilane (APTS) modified on the PDC/GCE to form APTS-Fe3O4/PDC composite film. The APTS-Fe3O4/PDC film had enhanced the effective electrode surface area and provided positively charged groups for electrostatic assembly of phosphate group of NADH.  相似文献   

14.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

15.
A novel enzymatic biosensing platform toward glucose is achieved with nanocomposite of magnetic nanoparticles (Fe3O4−CS−CD) and multi-walled carbon nanotubes (MWCNTs). The synergistic effect of chitosan, β-cyclodextrin and MWCNTs can facilitate electron transfer between enzyme and electrode based on the promoting results of the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The new biosensors exhibited direct electron transfer (DET) from enzyme to electrode after glucose oxidase (GOx) was immobilized on the modified electrode with the nanocomposite. Consequently, the enzymatic glucose biosensor displayed a considerably wide linear range (40 μM to 1.04 mM) with a high sensitivity of 23.59 μA mM−1cm−2, low detection limit of 19.30 μM, good selectivity, reproducibility and repeatability for detecting glucose. In addition, the current response still retained at 93.4 % after 25 days. Furthermore, the practical application of glucose biosensor was test in human serum samples with satisfactory accuracy, demonstrating promising and practical potential in biomedical diagnostics.  相似文献   

16.
Coupling nanotechnology with biocatalysis, a highly sensitive glucose biosensor for the study of electrochemical behaviors of glucose oxidase (GOx) was proposed by using monkshoodvine root–bark like carbon (MLC) as the platform for the biocatalytic deposition of AuNPs. The biosensor showed a linear range from 0.25 to 130 μM with a detection limit of 0.1 μM (S/N = 3) towards glucose and sensitivity of 3010 μA/mM. K value was calculated to be 67.4 μM. Furthermore, the proposed AuNPs/GOx–MLC modified pyrolytic graphite electrode (AuNPs/GOx–MLC/PGE) achieved direct electron transfer of GOx. Γ* was calculated to be 2.79 × 10?11 mol/cm2 and ks was 1.79 s?1. It also showed a remarkable electrocatalysis towards glucose.  相似文献   

17.
Graphene/Fe3O4 nanocomposite was prepared for the immobilization of hemoglobin (Hb) to improve the electron transfer between Hb and glass carbon electrode (GCE). The characterization of nanocomposites was described by transmission electron microscopy, Fourier transform infrared, Raman spectroscopy, and X-ray photoelectron spectroscopy, respectively. The electrochemistry of Hb on the graphene/Fe3O4-based GCE was investigated by cyclic voltammetry and amperometric measurement. The modified electrode showed a wide linear range from 0.25 μmol/L to 1.7 mmol/L with a correlation coefficient of 0.9967. The detection limit of the H2O2 biosensor was estimated at 6.0?×?10?6?mol/L at a signal-to-noise ratio of 3.  相似文献   

18.
Thionine (TH) adsorbed on multiwalled carbon nanotubes (MWCNTs) increases the load and dispersion of platinum nanoparticles (PtNPs) generated by chemical reduction of H2PtCl6 with NaBH4. Under the optimum conditions, the PtNPs‐TH‐MWCNTs/Au electrode electrocatalyzed the reduction and oxidation of H2O2 with high sensitivity, and after glucose oxidase (GOx) adsorption it responded to glucose concentration with a sensitivity of 0.14 A M?1 cm?2. The cyclic voltammetric cathodic peak current for NO2? reduction on PtNPs‐TH‐MWCNTs/Au responded linearly to NO2? concentration from 0.5 to 150 µM, with a sensitivity of 5.52 A M?1 cm?2 and a detection limit of 0.2 µM.  相似文献   

19.
A novel nanocomposite integrating the good biocompatibility of polyacrylic resin nanoparticles (PAR) and the good conductivity of colloidal gold nanoparticles was proposed to construct the matrix for the immobilization of hemoglobin (Hb) on the surface of a glassy carbon electrode (GCE). UV‐vis spectra demonstrated that Hb preserved its native structure after being entrapped into the composite film. The direct electrochemistry of hemoglobin (Hb) in this nanocomposite films showed a pair of well‐defined and quasi‐reversible cyclic voltammetric peaks with a formal potential of ?0.307 mV and a constant electron transfer rate of 2.51±0.2 s?1. The resultant amperometric biosensor showed fast responses to the analytes with excellent detection limits of 0.2 µM for H2O2 and 0.89 µM for TCA (S/N=3), and high sensitivity of 1108.6 for H2O2 and 77.14 mA cm?2 M?1 for TCA, respectively. The linear current response was found in the range from 0.59 to 7.3 µM (R2=0.9996) for H2O2 and from 5 to 85 µM (R2=0.9996) for TCA, while the superior apparent Michaelis–Menten constant was 0.012 mM for H2O2 and 0.536 mM for TCA, respectively. Therefore, the PAR‐Au‐Hb nanocomposite as a novel matrix opens up a possibility for further study on the direct electrochemistry of other proteins.  相似文献   

20.
Song Qu  Jilie Kong  Gang Chen 《Talanta》2007,71(3):1096-1102
An electrochemical sensing platform was developed based on the magnetic loading of carbon nanotube (CNT)/nano-Fe3O4 composite on electrodes. To demonstrate the concept, nano-Fe3O4 was deposited by the chemical coprecipitation of Fe2+ and Fe3+ in the presence of CNTs in an alkaline solution. The resulting magnetic nanocomposite brings new capabilities for electrochemical devices by combining the advantages of CNT and nano-Fe3O4 and provides an alternative way for loading CNT on electrodes. The fabrication and the performances of the magnetic nanocomposite modified electrodes have been described. Cyclic voltammetry (CV) and constant potential measurement indicated that the incorporated CNT exhibited higher electrocatalytic activity toward the redox processes of hydrogen peroxide. In addition, chitosan (CTS) has also been introduced into the bulk of the CNT/nano-Fe3O4 composite by coprecipitation to immobilize glucose oxidase (GOx) for sensing glucose. The marked electrocatalytic activity toward hydrogen peroxide permits effective low-potential amperometric biosensing of glucose, in connection with the incorporation of GOx into CNT/Fe3O4/CTS composite. The accelerated electron transfer is coupled with surface renewability. TEM images and XRDs offer insights into the nature of the magnetic composites. The concept of the magnetic loading of CNT nanocomposites indicates great promise for creating CNT-based biosensing devices and expands the scope of CNT-based electrochemical devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号