首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Salicylic acid is a phytohormone, playing crucial roles in signal transduction, crop growth, and development, and defense to environmental challenges. In this study, a highly selective electrochemical sensor was designed and used to determine salicylic acid using molecularly imprinted polymers for recognition. The electrochemical sensor was fabricated via stepwise modification of gold nanoparticle–graphene–chitosan and molecularly imprinted polymers on a glassy carbon electrode. With electrochemical deposition, a gold nanoparticle–graphene–chitosan film was deposited on the glassy carbon electrode and enhanced the sensitivity. Molecularly imprinted polymers with adsorbed template salicylic acid were added to the surface of the modified electrode. Cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the modified electrodes. Salicylic acid in wheat was quantified by the sensor using the molecularly imprinted polymer/gold nanoparticle–graphene–chitosan/glassy carbon electrode. Concentrations of salicylic acid from 5?×?10?10 to 5?×?10?5?mol?L?1 were determined showing that the developed sensor was suitable for the analysis of food.  相似文献   

2.
An electrochemical sensor based on a polyfurfural-electrochemically reduced graphene oxide modified glassy carbon electrode has been developed for the sensitive and rapid determination of nitrofurazone. The morphologies and properties of the sensor were characterized by electrochemical impedance spectroscopy, scanning electron microscopy, cyclic voltammetry, and differential pulse voltammetry (DPV). In pH 7.0 Britton–Robinson buffer solution, the as-prepared polyfurfural-electrochemically reduced graphene oxide modified glassy carbon electrode shows excellent electrocatalytic performance for the electrochemical reduction of nitrofurazone, and the reduction peak current is about 9.45, 1.31, and 1.25 times higher than that of the bare glassy carbon electrode, polyfurfural modified glassy carbon electrode, and electrochemically reduced graphene oxide modified glassy carbon electrode, respectively. The DPV determination of nitrofurazone indicates that the linear range and detection limit of nitrofurazone are 1–50 and 0.25?µmol/dm3, respectively. In addition, this sensor exhibits high selectivity, reproducibility, stability, and also was successfully used to directly determine nitrofurazone in the commercial antibacterial lotion with comparative sensitivity to high-performance liquid chromatography, showing its promising application prospects.  相似文献   

3.
《Analytical letters》2012,45(2):248-258
A poly(diallyldimethylammonium chloride)-graphene-multiwalled carbon nanotube modified glassy carbon electrode was fabricated and evaluated by cyclic voltammetry and differential pulse voltammetry. The modified electrode offered high sensitivity, selectivity, excellent long-term stability, and electrocatalytic activity for uric acid and dopamine. This sensor showed wide linear dynamic ranges of 5.0 to 350.0 µmol L?1 for uric acid and 10.0 to 400.0 µmol L?1 for dopamine in the presence of 500 µmol L?1 ascorbic acid. The limits of detection were 0.13 for uric acid and 0.55 µmol L?1 for dopamine. This functionalized electrode has potential application in bioanalysis and biomedicine.  相似文献   

4.
《Analytical letters》2012,45(6):894-906
A reduced graphene oxide-modified glassy carbon electrode for sensitive detection of rutin is reported. The modified electrode was obtained by one-step electrochemical reduction of graphene oxide on the bare glassy carbon electrode. In the presence of graphene, an enhanced electrochemical response for rutin appeared with a pair of well-defined anodic and cathodic peaks in pH 3.0 phosphate buffer. Under the optimized conditions, the anodic peak currents exhibited a linear relationship with rutin concentration from 0.1 to 2.0 µM with a detection limit of 23.2 nM. The modified electrode was employed to the analysis of tablets (with satisfactory recovery of 19.96 mg/per tablet) and Flos Sophorae. The graphene-modified electrode exhibited high sensitivity, good stability, and selectivity for the determination of rutin.  相似文献   

5.
Xiaoyu Cao 《Mikrochimica acta》2014,181(9-10):1133-1141
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe ssDNA on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. A thiol-tagged DNA strand coupled to horseradish peroxidase conjugated to AuNP served as a tracer. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. Hybridization with the target DNA was studied by measuring the electrochemical signal response of horseradish peroxidase using differential pulse voltammetry. The calibration plot is linear in the 5.0?×?10?14 and 5.0?×?10?9 M concentration range, and the limit of detection is 2.2?×?10?15 M. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA. The approach is deemed to provide a sensitive and reliable tool for highly specific detection of DNA.
Figure
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe (ssDNA) on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA  相似文献   

6.
The electrochemical behaviour of dopamine (DA) at a cleaned and alumina polished glassy carbon electrode (GCE) was studied using cyclic voltammetry (CV). The CV studies revealed that alumina polished GCE (AGCE) shows an enhanced oxidation peak current response with 217 mV negative potential shift towards DA than that of cleaned GCE. The differential pulse voltammetry result shows that the AGCE detects the DA in the linear concentration ranges from 0.15 to 25.25 µmol L?1. The limit of detection was calculated as 0.046 µmol L?1 with a sensitivity of 3.74 µA µmol L?1 cm?2 for the determination of DA. The fabricated AGCE shows a satisfactory selectivity, practicality along with appreciable repeatability and reproducibility.  相似文献   

7.
Folic acid was polymerised electrochemically at a glassy carbon electrode surface from 0.1 mol L?1 phosphate buffer saline solution, pH 5.0, containing 0.1 mmol L?1 monomer. The obtained thin film was porous with a pore size of 50–60 nm. Since its electrochemical stability was rather short, the polyfolate film was covered with a graphene‐chitosan composite layer which increased its stability significantly. The best strategy to immobilise the enzyme was crosslinking with glutaraldehyde. The lifetime of this glucose biosensor in use was at least 12 days, on‐shelf life time was at least 30 days. The linear range was up to 1 mmol L?1 and the LOD was 0.6 µmol L?1. The first polyfolate‐based biosensor was applied to analysis of natural samples.  相似文献   

8.
A modified electrode was prepared using electrodeposition methods to immobilize caffeic acid (CAF) onto the surface of a glassy carbon electrode (GCE) to create a polymer suitable for biosensor development. The polymer film coverage of the surface bound species was further optimized using electrodeposition methods, thus increasing the surface coverage to ca. 10?9 mol cm?2. Using cyclic voltammetry, the modified carbon electrode was used to facilitate and observe the electrocatalytic oxidation of coenzymes such as NADH, cysteine, and glutathione at different concentrations. A calibration curve was determined in each case within the concentration range; 300 nM to 10 mM, with the limits of detection (LOD) of 246 µM, 99 µM, 2.2 µM for NADH, cysteine, and glutathione respectively.  相似文献   

9.
A simple and sensitive differential pulse stripping voltammetric method was developed for the determination of antimony(III) using a selenium-doped carbon paste electrode modified with an ionic liquid, graphene, and gold nanoparticles. The conditions, including the mass of graphene, concentration of hydrochloric acid, deposition potential, and deposition time were optimized by single-factor experiments. Under the optimal conditions, a linear equation of ISb(III) (µA)?=??16.9882???11.0929 c (µmol/L) (R?=?0.9965) and a detection limit of 2.7?×?10?8?mol/L were obtained for 8.0?×?10?8 to 4.8?×?10?6?mol/L antimony(III). The response shows that the sensor enhances the sensitivity of antimony due to the high conductivity and large surface areas of the ionic liquid, graphene, and gold nanoparticles. This electrode may provide a new sensing platform for the determination of antimony.  相似文献   

10.
Biofunctionalizing a simple and disposable graphene oxide-modified screen-printed carbon electrode with anti-interleukin-15 antibodies has been successfully demonstrated for the first time for the label-free electrochemical detection of interleukin-15, a biomarker of early HIV infection. To improve the electrochemical reactivity and introduce carboxylic groups on the surface of screen-printed carbon electrode, high-quality graphene oxide was used for the modification of screen-printed carbon electrode. With simple modification of the screen-printed carbon electrode, the device exhibited satisfactory sensitivity, selectivity, stability, reproducibility, and regenerability. The immunosensor provided a detection limit of 3.51?ng?mL?1 and a sensitivity of 0.5655?µA cm?2?mL?ng?1. The simply constructed immunosensor thus rendered promising device for immunoreactions on the surface of the electrode.  相似文献   

11.
Three-dimensional copper hydroxide nanosupercages and electrochemically reduced graphene oxide were used to modify the glassy carbon electrode for the selective determination of hydrogen peroxide. The morphology and electrochemistry properties of copper hydroxide nanosupercage/electrochemically reduced graphene oxide/glassy carbon electrode were characterized using transmission electron microscopy, scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectra, Raman spectra, cyclic voltammetry, and electrochemical impedance spectroscopy. The resulting copper hydroxide nanosupercage/electrochemically reduced graphene oxide/glassy carbon electrode showed favorable performance for the electrocatalytic reduction of hydrogen peroxide. The amperometric current–time curve of the electrochemical sensor exhibited a wide linear range from 0.5 to 1030?µM with a limit of detection of 0.23?µM at a signal-to-noise ratio of three. Moreover, the sensor provided favorable selectivity, reproducibility, and stability and was used for the determination of H2O2 in tap water.  相似文献   

12.
The fabrication of a highly sensitive amperometric glucose biosensor based on silver nanowires (AgNWs) is presented. The electrochemical behavior of glassy carbon electrode modified by Ag NWs exhibits remarkable catalytic performance towards hydrogen peroxide (H2O2) and glucose detection. The biosensor could detect glucose in the linear range from 0.005 mM to 10 mM, with a detection limit of 50 µM (S/N=3). The glucose biosensor shows high and reproducible sensitivity of 175.49 µA cm?2 mM and good stability. In addition, the biosensor exhibits a good anti‐interference ability and favorable stability over relatively long‐term storage (more than 21 days).  相似文献   

13.
In this work, a sensitive electrochemical DNA biosensor for the detection of sequence‐specific target DNA was reported. Firstly, CuO nanospindles (CuO NS) were immobilized on the surface of a glassy carbon electrode (GCE). Subsequently, gold nanoparticles (Au NPs) were introduced to the surface of CuO NS by the electrochemical deposition mode. Probe DNA with SH (HS‐DNA) at the 5′‐phosphate end was covalently immobilized on the surface of the Au NPs through Au? S bond. Scanning electron microscopy (SEM) was used to elucidate the morphology of the assembled film, and electrochemical impedance spectroscopy technique (EIS) was used to investigate the DNA sensor assembly process. Hybridization detection of DNA was performed with differential pulse voltammetry (DPV) and the methylene blue (MB) was hybridization indicator. Under the optimal conditions, the decline of reduction peak current of MB (ΔI) was linear with the logarithm of the concentration of complementary DNA from 1.0×10?13 to 1.0×10?6 mol·L?1 with a detection limit of 3.5×10?14 mol·L?1 (S/N=3). In addition, this DNA biosensor has good selectivity, and even can distinguish single‐mismatched target DNA.  相似文献   

14.
A simple, low-cost and sensitive electroanalytical method was developed for the simultaneous determination of p-nitrophenol and o-nitrophenol isomers in water samples at a glassy carbon electrode (CGE) in the presence of cationic surfactant. The electrochemical behavior of p-nitrophenol and o-nitrophenol was studied by cyclic voltammetry (CV) in 0.1?mol L?1 acetate/acetic acid buffer (pH 3.70) in the presence and absence of cetylpyridinium bromide. The resolution of overlapped cathodic peaks potentials (Epc) of isomers was successfully improved in the presence of 100.0?µmol L?1 cetylpyridinium bromide, thus making this approach ideal for the simultaneous determination of isomers. Under the optimized conditions in 0.05?mol L?1 HEPES buffer at pH 7.0 using differential pulse voltammetry (DPV) at a scan rate of 45?mV s?1, pulse amplitude of 220?mV and modulation time of 10?ms, limits of detection 0.59?µmol L?1 for p-nitrophenol and 1.14?µmol L?1 for o-nitrophenol were obtained with linear ranges from 2.0 to 60.0?µmol L?1 and 3.0 to 60.0?µmol L?1, respectively. The intraday precision was assessed as relative standard deviation (%) for 20.0 and 40.0?µmol L?1 concentrations were 4.30% and 2.41% for p-nitrophenol and 4.87% and 2.20% for o-nitrophenol, respectively. The developed method was applied for the determination of the isomers in lake water samples. The accuracy was attested by comparison with high-performance liquid chromatography with diode array detection (HPLC-DAD) as a reference analytical technique. Recovery values ranging from 90.3% to 111.8% also attested to the accuracy of method for analysis of real samples.  相似文献   

15.
A sensitive and selective electrochemical method for the determination of dopamine (DA) was developed using a calix[4]arene crown‐4 ether (CACE) film modified glassy carbon electrode (GCE).The modified electrode exhibited good electrocatalytic activity for electrochemical oxidation of DA in the pH 6.00 Britton–Robinson buffer solution, and ascorbic acid (AA) did not interfere with it. The diffusion coefficient (D=2.7×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient (α=0.54) of DA at the surface of CACE were determined using electrochemical approaches. The catalytic oxidation peak currents showed a linear dependence on the DA concentration and a linear analytical curve was obtained in the range of 2.0×10?5–1.0×10?3 M of DA with a correlation coefficient of 0.9990. The detection limit (S/N=3) was estimated to be 3.4×10?6 M. This method was also examined for the determination of DA in an injection sample. In addition, effects of possible interferences were investigated. The present work shows the potential of the proposed method for the fabrication of a modified electrode, as it can be effectively used for voltammetric detection of DA.  相似文献   

16.
Direct electron transfer of immobilized copper, zinc‐superoxide dismutase (SOD) onto electrodeposited nickel‐oxide (NiOx) nanoparticle modified glassy carbon (GC) electrode displays a well defined redox process with formal potential of ?0.03 V in pH 7.4. Cyclic voltammetry was used for deposition of (NiOx) nanoparticles and immobilization of SOD onto GC electrode. The surface coverage (Γ) and heterogeneous electron transfer rate constant (ks) of immobilized SOD are 1.75×10?11 mol cm?2 and 7.5±0.5 s?1, respectively. The biosensor shows a fast amperometric response (3 s) toward superoxide at a wide concentration range from 10 µM to 0.25 mM with sensitivity of 13.40 nA µM?1 cm?2 and 12.40 nA µM?1 cm?2, detection limit of 2.66 and 3.1 µM based on anodically and cathodically detection. This biosensor exhibits excellent stability, reproducibility and long life time.  相似文献   

17.
Simultaneous electropolymerization of 3‐methylthiophene and incorporation of Laccase (LAC) was carried out in the presence of propylene carbonate as a medium by amperometric method. This enzyme modified electrode was used for the sensing of polyphenol. Catechol is taken as a model compound for the study. UV‐Vis spectral studies suggest no denaturation of LAC in presence of propylene carbonate. The SEM studies reveal the surface morphology and incorporation of LAC in P3MT with agglomerated flaky masses are observed in with and without enzyme micrographs. The cyclic voltammograms were recorded for 0.01 mM catechol on plain glassy carbon, polymer and enzyme incorporated electrodes at pH 6.0 and scan rate 50 mV s?1. The fabricated electrochemical biosensor was used for the determination of catechol in aqueous solution by Differential Pulse Voltammetry (DPV) technique. The concentration linear range of 8×10?8 to 1.4×10?5 M a value of Michealis? Menten constant Km=7.67 µmol dm?3 and activation energy is 32.75 kJ mol?1. It retains 83 % of the original activity after 60 days which is much higher than that of other biosensors. The developed biosensor was used to quantify catechol in the determination in real samples.  相似文献   

18.
Diphenylamine (DPA) monomers have been electropolymerized on the amino‐functionalized multiwalled carbon nanotube (AFCNT) composite film modified glassy carbon electrode (GCE) by cyclic voltammetry (CV). The surface morphology of PDPA‐AFCNT was studied using field‐emission scanning electron microscopy (FE‐SEM). The interfacial electron transfer phenomenon at the modified electrode was studied using electrochemical impedance spectroscopy (EIS). The PDPA‐AFCNT/GCE represented a multifunctional sensor and showed good electrocatalytic behavior towards the oxidation of catechol and the reduction of hydrogen peroxide. Rotating‐disk electrode technique was applied to detect catechol with a sensitivity of 1360 µA mM?1 cm?2 and a detection limit of 0.01 mM. Amperometric determination of hydrogen peroxide at the PDPA‐AFCNT film modified electrode results in a linear range from 10 to 800 µM, a sensitivity of 487.1 µA mM?1 cm?2 and detection limit of 1 µM. These results show that the nano‐composite film modified electrode can be utilized to develop a multifunctional sensor.  相似文献   

19.
A multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (MWNT-GCE) was used to study the electrochemical behaviour of1-hydroxypyrene (1-OHP) and applied to its determination. The results showed that the modified electrode had a strong adsorptive ability to 1-OHP and enhances its electrochemical signal. By square wave voltammetry, the linear relationship of 1-OHP was 6?×?10?9???8?×?10?7?mol?L?1 with a linear correlation coefficient of 0.996, and the detection limit was 1?×?10?10?mol?L?1. Compared with other published methods, this newly proposed method possesses many advantages such as very low detection limit, fast response, low cost and simplicity. And this method was applied successfully in the determination of 1‐OHP in real human urine samples.  相似文献   

20.
《Analytical letters》2012,45(15):2832-2843
Abstract

This work demonstrates the electrochemical behavior of the 1-phenyl-3-methyl-4-(α-furoyl)-pyrazolone-5 (HPMαFP) modified glassy carbon electrode (HPMαFP/GCE) by a dropletting method. Tyrosine (Tyr) was detected at the HPMαFP/GCE by cyclic voltammetry. The mechanism and the best condition of electrode reaction were studied. The results indicate Tyr has an excellent electrochemical response at HPMαFP/GCE; under optimized experimental conditions, the peak current is proportional to the concentration of Tyr over a wide range. The linear regression equation at HPMαFP/GCE is IPa (µA) = 1.01134 + 0.96716 C (µmol · L?1) (r = 0.99914). The low detection limit is 1.6 × 10?7 mol · L?1. The modified electrode exhibited high sensitivity, good selectivity, and reproducibility, and it is easy to prepare.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号