1.
Ruddock IS  Han TP 《Optics letters》2006,31(7):891-893
The design and operating parameters of a new class of continuously distributed optical fiber sensor are described. By use of counterpropagating pulses, two-photon excitation of fluorescence from ions doped into the fiber enables any position to be monitored. By this means temperature and also strain may be sensed with high spatial and temporal resolution. As the doped fiber is transparent for single-photon absorption at the wavelength of the light pulses, attenuation does not set an upper limit to its length.  相似文献   

2.
基于磁二色效应的光发射电子显微镜磁成像技术是研究薄膜磁畴结构的一种重要研究手段,具有空间分辨率高、可实时成像以及对表面信息敏感等优点.以全固态深紫外激光(波长为177.3 nm;能量为7.0 eV)为激发光源的光发射电子显微技术相比于传统的光发射电子显微镜磁成像技术(以同步辐射光源或汞灯为激发源),摆脱了大型同步辐射光源的限制;同时又解决了当前阈激发研究中由于激发光源能量低难以实现光电子直接激发的技术难题,在实验室条件下实现了高分辨磁成像.本文首先对最新搭建的深紫外激光-光发射电子显微镜系统做了简单介绍.然后结合超高真空分子束外延薄膜沉积技术,成功实现了L10-FePt垂直磁各向异性薄膜的磁畴观测,其空间分辨率高达43.2 nm,与利用X射线作为激发源的光发射电子显微镜磁成像技术处于同一量级,为后续开展高分辨磁成像提供了便利.最后,重点介绍了在该磁成像技术方面取得的一些最新研究成果:通过引入Cr的纳米"台阶",成功设计出FePt的(001)与(111)双取向外延薄膜;并在"台阶"区域使用线偏振态深紫外激光观测到了磁线二色衬度,其强度为圆二色衬度的4.6倍.上述研究结果表明:深紫外激光-光发射电子显微镜磁成像技术在磁性薄膜/多层膜体系磁畴观测方面具备了出色的分辨能力,通过超高真空系统与分子束外延薄膜制备系统相连接,可以实现高质量单晶外延薄膜制备、超高真空原位传输和高分辨磁畴成像三位一体的功能,为未来磁性薄膜材料的研究提供了重要手段.  相似文献   

3.
Electron beam induced current (EBIC) at p–n junctions can be measured in high spatial resolution using a thin lamella geometry, where most incident electrons transmit the sample. We explore the case of low excitation energies in a wedge‐shaped lamella geometry to increase resolution in a controlled way. We compare a sample with high (Si) and low (manganite‐titanate heterojunction) diffusion length and use Monte Carlo based simulations as a reference. It is shown that the EBIC signal obtained from the Si junction vanishes below a thickness of 300 nm, whereas this happens at 80 nm in the PCMO–STNO junction. This allows for achieving an EBIC resolution of better than 50 nm for the latter system. The observed fundamental differences between the silicon and the perovskite junction are discussed in terms of preparation induced ‘dead’ layers and surface recombination.  相似文献   

4.
Near-infrared (NIR) fluorescence imaging is an important imaging technology in deep-tissue biomedical imaging and related researches, due to the low absorption and scattering of NIR excitation and/or emission in biological tissues. Laser scanning confocal microscopy (LSCM) plays a significant role in the family of fluorescence microscopy. Due to the introduction of pinhole, it can provide images with optical sectioning, high signal-to-noise ratio and better spatial resolution. In this study, in order to combine the advantages of these two techniques, we set up a fluorescence microscopic imaging system, which can be named as NIR-LSCM. The system was based on a commercially available confocal microscope, utilizing a NIR laser for excitation and a NIR sensitive detector for signal collection. In addition, NIR fluorescent nanoparticles (NPs) were prepared, and utilized for fluorescence imaging of the ear and brain of living mice based on the NIR-LSCM system. The structure of blood vessels at certain depth could be visualized clearly, because of the high-resolution and large-depth imaging capability of NIR-LSCM.  相似文献   

5.
介绍了基于球面弯晶的X射线高分辨单色背光成像技术。通过对球面弯晶背光成像系统的分析,获得成像关键性能参数随成像系统设计参数变化的关系,设计了应用于神光Ⅱ激光装置的单色背光成像系统。利用石英球面弯晶,采用Mg的类H共振发射线以及利用云母球面弯晶,采用Mo连续谱中3.14 keV能点进行背光实验,获得了内爆靶丸的单色投影图像,空间分辨在较大范围内好于5 m。这种成像技术在现阶段惯性约束聚变(ICF)实验研究中能够发挥许多重要的作用,特别是对内爆靶丸压缩流线的测量和流体力学不稳定性的诊断。  相似文献   

6.
高飞  刘华锋  施鹏程 《物理学报》2007,56(7):4229-4234
设计了一系列实验对Concorde MicroPET Rodent R4小动物正电子断层成像系统(该系统是Concorde Microsystems公司开发的小动物专用PET扫描仪,该扫描仪具有32层探测器环,动物入口孔径为120mm,横向视野为100mm,轴向深度为78mm,标称的视野中央处的空间分辨率可达1.8mm以下)的空间分辨率、灵敏度、散射率等性能参数进行了测试,测试结果显示该扫描仪视野中心的横向空间分辨率为1.9mm, 轴向空间分辨率为1.88mm, 在能窗设定为250—750keV时系统的绝对灵敏度为39.88 cps/kBq, 同样能窗下二维重建散射分数为50.6%,三维重建散射分数为32.3%. 关键词: 正电子断层成像仪 性能测试  相似文献   

7.
We introduce an accelerated gradient echo (GRE) sequence combining simultaneous multislice excitation (SMS) with echo-shifting technique for high spatial resolution blood oxygen level dependent (BOLD) functional MRI (fMRI). The simulation was conducted to optimize scan parameters. To validate the feasibility of the proposed technique, the visual and motor task experiments were performed at 7.0 Tesla (T). The single-shot EPI sequence was also applied in comparison with the proposed technique. The simulation results showed that an optimized flip angle of 9° provided maximal BOLD contrast for our scanning scheme, allowing low power deposition and SMS acceleration factor of 5. Additionally, parallel acquisition imaging with acceleration factor of 2 was utilized, which allowed a total acceleration factor of 10 in volunteer study. The experiment results showed that geometric distortion-free BOLD images with voxel size of 1.0 × 1.0 × 2.5 mm3 were obtained. Significant brain activation was identified in both visual and motor task experiments, which were in accordance with previous investigations. The proposed technique has potential for high spatial resolution fMRI at ultra-high field because of its sufficient BOLD sensitivity as well as improved acquisition speed over conventional GRE-based techniques.  相似文献   

8.
太赫兹波成像技术一个最显著的制约因素是其有限的空间分辨率。提出通过在样品前加小孔的方法来提高传统太赫兹时域光谱装置成像的空间分辨率。采用在样品前约2 mm处加直径为0.5 mm小孔的方法使成像的空间分辨率从1.276 mm提高到0.774 mm,提高0.502 mm,约39%。通过这个简单的方法在传统的太赫兹时域光谱成像装置上实现了空间分辨率从毫米量级到亚毫米量级的提高。聚乙烯板上直径为1 mm的小孔被作为成像的研究对象,分别采用传统的太赫兹时域光谱装置对样品进行直接成像和在样品前约2 mm处加直径为0.5 mm的小孔后对样品成像两种方式,并采用损失成像中信噪比较好的能量损失成像,对比两种方式得到的样品的太赫兹像,结果显示聚乙烯板上小孔的边界加小孔后成像比不加小孔直接成像明显清晰。证实了在样品前加小孔可以有效的提高太赫兹成像系统的空间分辨率。从理论上对通过在样品前加小孔提高系统空间分辨率的方法进行了分析,指出小孔尺寸越小,系统的空间相干长度越大,空间分辨率越高,但同时太赫兹信号的强度会相应减小。该方法可以简单有效的提高太赫兹时域光谱装置成像的空间分辨率,从而进一步拓展太赫兹谱成像技术的应用领域。  相似文献   

9.
The purpose of this study was to investigate and to optimize the performance of two-dimensional spatially selective excitation pulses used for navigator applications on a clinical scanner. The influence of gradient imperfections, off-resonance effects, and incomplete k-space covering on the pencil beam-shaped spatial excitation profile of the 2D RF pulse was studied. The studies involved experiments performed on phantoms and in vivo. In addition, simulations were carried out by numerical integration of the Bloch equations. The accuracy of positioning of the pencil beam was increased by a factor of three by employing a simple correction scheme for the compensation of gradient distortions. The spatial selectivity of the 2D RF pulse was improved by taking sampling density corrections into account. The 2D RF pulse performance was found to be sufficient to monitor the diaphragm motion even at moderate gradient strength. For applications, where a high spatial resolution is required or a less characteristic contrast is present a strong gradient system is recommended.  相似文献   

10.
The principal advantage of NMR at high field is the concomitant increase in signal-to-noise ratio (SNR). This can be traded for improved spatial resolution and combined with parallel imaging to achieve higher temporal resolution. At high field strength, the RF-wavelength and the dimension of the human body complicate the development of NMR coils. For example, at 7 T, the wavelength in free space corresponds to about 1m. The dielectric constant in tissue with a high water content can be as high as 70 and at a larmor frequency of 300 MHz, this corresponds to a wavelength inside tissue of less than 15 cm. The operating wavelength is thus comparable to the diameter of most body parts. To this end, both temporal and spatial variations of the excitation field must be taken into account in addition to the expected increase in conductivity. For all these reasons, we find the propagation of radiation at ultra high fields (>4 T) new phenomena commonly observed in quantum optics but traditionally negligible in NMR such as phase modulation of the excitation field such that the identity between pulse area and flip angle is no longer valid. In this paper, the emergence of field propagation phenomena in NMR experiments is analytically and numerically demonstrated. It is shown that in addition to the well-studied dielectric resonance phenomena at high magnetic fields (>4 T), field propagation effects transform the excitation pulse into an adiabatic excitation. The high field strength also mean that nonlinear effects such as self-induced transparency are now possible in NMR experiments.  相似文献   

11.
An ultrafast three-dimensional readout of coherent optical-phonon oscillations from a diamond film is demonstrated using temporally and spectrally shaped ultrashort laser pulses, delivered by a compact, oscillator-only laser system. This system integrates a long-cavity ytterbium-fiber-laser-pumped 30?fs Cr:forsterite oscillator with a photonic-crystal-fiber soliton frequency shifter and a periodically poled lithium niobate spectrum compressor, providing coherent Raman excitation and time-delayed interrogation of optical phonons in diamond at a 20?MHz repetition rate with a submicrometer spatial resolution.  相似文献   

12.
A new concept of Variable Field Proton–Electron Double-Resonance Imaging (VF PEDRI) is proposed. This allows for functional mapping using specifically designed paramagnetic probes (e.g. oxygen or pH mapping) with MRI high quality spatial resolution and short acquisition time. Studies performed at 200 G field MRI with phantoms show that a pH map of the sample can be extracted using only two PEDRI images acquired in 140 s at pre-selected EPR excitation fields providing pH resolution of 0.1 pH units and a spatial resolution of 1.25 mm. Note that while concept of functional VF PEDRI was demonstrated using the pH probe, it can be applied for studies of other biologically relevant parameters of the medium such as redox state, concentrations of oxygen or glutathione using specifically designed EPR probes.  相似文献   

13.
双光子技术在三维成像和三维存储技术中的应用   总被引:3,自引:0,他引:3  
汪洁  唐志列  徐险峰 《光学技术》2002,28(4):296-298
对双光子过程的空间分辨能力进行了理论分析。阐明了双光子技术在三维成像和三维存储中的独特优势。着重介绍了双光子技术与扫描共焦显微术、近场显微术相结合进行三维成像 ,以及一种多焦点多光子显微术和用连续光源激发的双光子三维成像技术的研究和进展情况。对建立在共焦显微镜基础之上的双光子三维光存储和微细加工方面的研究也作了回顾与展望  相似文献   

14.
激光驱动X射线单色背光照相系统优化设计   总被引:2,自引:0,他引:2  
 基于球面几何光学对激光驱动X射线单色背光照相系统的空间分辨力和成像效率等关键性能参数进行了理论推导,分析了当系统光学参数发生变化时,系统空间分辨力和成像效率互为制约的关系,由此提出了在保证能探测到图像的前提下,尽量提高系统空间分辨能力的优化设计方法。按照此方法具体设计了光子能量分别为5.07 keV和5.41 keV的两套背光照相系统,并用光线追迹模拟实验进行了验证。结果表明:设计的两套系统都能够在大约1 cm2的视场范围内,具有优于10 μm的空间分辨力。  相似文献   

15.
Advances in electron optics and fast-pulsed light sources have enabled the imaging of nanoscale structures with simultaneous energy and time resolutions. We present the results obtained from a time-resolved time-of-flight photoemission electron microscopy (TR-TOF-PEEM) system. This system combined the spatial resolution of conventional PEEM with the time resolution of a femtosecond-pulsed laser and the energy resolution of a TOF energy analyzer. The TOF-PEEM system consists of three electrostatic lenses in front, a drift tube for the measurement of TOF, and a delay line detector (DLD) at the end of the optics. The excitation source is femtosecond pulses from a cavity-dumped Ti:sapphire oscillator that is frequency-doubled to 400 nm using a β-barium borate (BBO) crystal. Using a pump-probe two-photon photoemission technique, we demonstrate an example of sub-100 nm space-resolved ultrafast time evolution of the electron energy spectra for the plasmon resonance of an Ag-coated Si nanostructure, which exhibited unexpectedly intense high energy photoemission signals that show different time evolution between bright and dark regions in a PEEM image.  相似文献   

16.
相干反斯托克斯拉曼散射(CARS)技术是一种非常重要的燃烧诊断技术,该技术具有非常强的抗干扰能力和非常高的测量精度。但空间分辨力不足会使CARS技术产生很强的空间平均效应,引起成CARS光谱畸变,进而造成CARS光谱分析困难,无法通过CARS光谱反演燃烧场参数。针对非稳腔空间增强探测CARS(USEDCARS)技术存在的空间分辨不足以及空间分辨力不易改变的特点,分析了影响USEDCARS技术测量空间分辨力的各种因素,采用一组轴棱锥对USEDCARS系统中的泵浦激光进行环状光束整形,并通过调节轴棱锥之间的距离获得了不同直径的环状光束,在此基础上,建立了空间分辨可调USEDCARS诊断系统。开展了空间分辨力分析实验,获得了CARS信号强度随空间位置的分布数据,以CARS信号总强度95%包含的空间区域代表CARS的纵向空间分辨力,以此计算得到了CARS系统空间分辨力为1.7~6.5 mm连续可调。其中,高分辨力情况,达到了现有BOXCARS技术的空间分辨力。利用所建立的空间分辨可调USEDCARS诊断系统测量了酒精/空气预混火焰温度参数,获得了不同空间分辨条件下的CARS光谱。空间分辨力为1.7 mm时,获得了高质量CARS光谱,通过光谱拟合给出了所测火焰的温度信息。分辨力分别为4.9和6.5 mm时获得了较强的CARS信号,但存在光谱畸变。结果显示,空间分辨力对CARS信号的强度和空间平均效应有很大地影响,提高测量的空间分辨力可以有效消除空间平均效应,获得准确的CARS光谱,增强光谱拟合精度,同时空间分辨可调的特性使该系统能够更好地适应不同实验条件下的诊断工作。  相似文献   

17.
We investigate a novel concept to efficiently generate multiphoton induced fluorescence from organic molecules. The concept is based on frustrating the energy transfer between a fluorescent donor and one or more acceptors in conjugated molecules. The nonlinearity is not based on higher order molecular susceptibilities but entirely on their linear properties. Therefore, in contrast to nonresonant multiphoton absorption, this method does not require high local intensities. Likewise, the production of visible fluorescence does not require an infrared excitation wavelength. Hence, when applied to scanning microscopy this property is predicted to increase spatial resolution. Instead of the ∼10 GW/cm2 required in non-resonant multiphoton excitation, focal intensities ∼10 MW/cm2 are expected to produce an equally strong nonlinear signal. The predicted resolution is up to 30% greater than that of an ideal confocal microscope operating at the same fluorescence wavelength. The resolution improvement over non-resonant two-photon absorption microscopes is about two-fold in all directions.  相似文献   

18.
多焦点结构光照明显微技术(multifocal structured illumination microscopy, MSIM)能在50μm的成像深度内和1Hz的成像速度下实现两倍于衍射极限分辨率的提升,相比传统的宽场结构光照明显微技术,具有较大的成像深度和层析能力,更适合应用于厚样品的长时程三维超分辨成像.然而, MSIM存在成像速度慢、图像处理过程复杂等问题.本文提出了一种基于平场复用多焦点结构光照明的快速超分辨显微成像方法和系统(flat-field multiplexed MSIM, FM-MSIM),通过在照明光路中插入光束整形器件,将高斯光束转变为均为分布的平顶光束,提高激发点阵的强度均匀性和扩大视场;通过将每个衍射受限的激发点沿y方向延长,形成新的多路复用多焦点阵照明图案,提高能量利用率,减少扫描步数,进而提高成像速度和信噪比;结合基于多重测量矢量模型的稀疏贝叶斯学习图像重构算法,简化图像重构步骤,在保证空间分辨率的同时实现至少4倍于传统MSIM的成像速度.在此基础上,利用搭建的FM-MSIM系统进行了BSC细胞微管样片和小鼠肾切片标准样片的超分辨成像实验,实验结果证明...  相似文献   

19.
We report for the first time the tip‐enhancement of resonance Raman scattering using deep ultraviolet (DUV) excitation wavelength. The tip‐enhancement was successfully demonstrated with an aluminum‐coated silicon tip that acts as a plasmonic material in DUV wavelengths. Both the crystal violet and adenine molecules, which were used as test samples, show electronic resonance at the 266‐nm excitation used in the experiments. With results demonstrated here, molecular analysis and imaging with nanoscale spatial resolution in DUV resonance Raman spectroscopy can be realized using the tip‐enhancement effect. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
We present a two-dimensional optical coherence vibration tomography (2DOCVT) system with an ultra-precision displacement resolution of ~0.1 nm that is capable of in site real-time absolute displacement measurement of structural line vibrations. Experimental results of sinusoidal, sweep and impulse vibrations were reported. The key figures of merit such as the 2DOCVT system could obtain fast line vibration measurement without scanning and it also could be used to capture structural modal parameters in one single impulse excitation measurement without any vibration excitation input information, making it attractive for the application in low-frequency vibration measurement and response-only modal analysis.  相似文献   