首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The present procedure is based on the sequential selective reduction of mercury(II) and methyl mercury using two gas–liquid separators in series. Cold vapor atomic absorption spectrometry was used for detection. Mercury(II) is reduced by a 0.01% m/v sodium tetrahydroborate solution and driven to the absorption cell in the first separator. The methyl mercury species is reduced by the same reductant but at a 0.3% m/v concentration, and in the presence of iron(III) chloride. Parameters such as argon flow rate, and the NaBH4 and dithiophosphoric acid diacyl ester concentrations were optimized. At the optimized conditions, and using aqueous standards for calibration, the corresponding limits of detection (3σb, n=10) were 400 and 600 ng l−1 for mercury(II) and methyl mercury, respectively. The sample throughput was 12 h−1. The procedure was used for the determination of methyl mercury in dogfish liver and dogfish muscle certified reference materials, and good concordance between found and certified values was observed.  相似文献   

2.
Cloud point methodology has been successfully used for the preconcentration of trace amounts of Cd and Pb as a prior step to their determination by flame atomic absorption spectrometry. O,O-Diethyldithiophosphate and Triton X-114 are used as hydrophobic ligand and non-ionic surfactant, respectively. After phase separation at 40 °C based on cloud point of the mixture, the surfactant-rich phase is diluted with methanol. The enriched analyte in the final solution is determined by flame atomic absorption spectrometry using conventional nebulization. After optimization of the complexation and extraction conditions, enhancement factors of 22 and 43 were obtained for Cd and Pb, respectively. Under the experimental conditions used, preconcentration of only 10 ml of sample in the presence of 0.05% (v/v) Triton X-114 permitted the detection of 0.62 μg l−1 of Cd and 2.86 μg l−1of Pb. The proposed method was applied to the determination of Cd and Pb in human hair samples.  相似文献   

3.
A mild, efficient and convenient extraction method of using 2-mercaptoethanol contained extractant solution combined with an incubator shaker for determination of mercury species in biological samples by HPLC–ICP-MS has been developed. The effects of the concentration of 2-mercaptoethanol, the composition of the extractant solution and the shaking time on the efficiency of mercury extraction were evaluated. The optimization experiments indicated that the quantitative extraction of mercury species from biological samples could be achieved by using 0.1% (v/v) HCl, 0.1% (v/v) 2-mercapoethanol and 0.15% (m/v) KCl extractant solution in an incubator shaker for shaking overnight (about 12 h) at room temperature. The established method was validated by analysis of various biological certified reference materials, including NRCC DOLT-3 (dogfish liver), IAEA 436 (tuna fish), IAEA MA-B-3/TM (garfish filet), IAEA MA-M-2/TM (mussel tissue), GBW 08193 (bovine liver) and GBW 08572 (prawn). The analytical results of the reference materials were in good agreement with the certified or reference values of both methyl and total mercury, indicating that no distinguishable transformation between mercury species had occurred during the extraction and determination procedures. The limit of detection (LOD) for methyl (CH3Hg+) and inorganic mercury (Hg2+) by the method are both as 0.2 μg L−1. The relative standard deviation (R.S.D.s) for CH3Hg+ and Hg2+ are 3.0% and 5.8%, respectively. The advantages of the developed extraction method are that (1) it is easy to operate in HPLC–ICP-MS for mercury species determination since the extracted solution can be directly injected into the HPLC column without pH adjustment and (2) the memory effect of mercury in the ICP-MS measurement system can be reduced.  相似文献   

4.
A study on transport, kinetic selectivity and stability in SLM operations using a new carrier, the molecule 2-hydroxy-5-dodecylbenzaldehyde (2H5DBA) in kerosene, is described. A simple transport model is derived to evaluate the mass transfer coefficient in the membrane. Finally a comparison with the di-(2-ethylhexyl) phosphoric acid (D2EHPA) carrier in kerosene is made. The SLM system was employed and tested in the removal of Cu2+ from wastewater by using the operating conditions obtained from L–L extraction tests. Studies on the kinetics of copper extraction by using the 2H5DBA showed that complexation reaction is very fast. Transport tests were performed at different carrier concentrations (10%, 30%, 50% (v/v)) showing the improvement of SLM performance with increasing its concentration. Operating the SLM at optimum conditions (50% (v/v) 2H5DBA concentration in kerosene, feed pH 5, strip pH 2.2) final copper concentrations in the feed and strip phases were, respectively, 2.0 and 47.0 mg L−1, starting from 50 mg L−1 in the feed, meaning a significant up-hill transport. The fluxes (J) were calculated by fitting the experimental data of copper concentration in the feed by an exponential equation. They were used to calculate the transport (kinetic) selectivities of Cu2+ SLM separation over Ni2+, Zn2+ and Mn2+, given by the ratio J0(Cu)/J0(M), where M = Ni, Zn and Mn. The values were 37.4, 48.2 and 42.1, respectively. Transport and stability tests at the optimal carrier concentration by using the 2H5DBA and the D2EHPA in kerosene were carried out to compare them in terms of flux, lifetime and mass transfer coefficients. Experimental data evidenced for 2H5DBA a lower copper flux (8.67 mmol h−1 m−2 versus 36.71 mmol h−1 m−2), a lower lifetime (20 h versus 57 h) and lower mass transfer coefficient in the membrane (3.00 × 10−7 m s−1 versus 2.00 × 10−6 m s−1) but the selectivity of the separation process can overcome the disadvantages.  相似文献   

5.
A HPLC method with automated column switching and UV-diode array detection is described for the simultaneous determination of Vitamin D3 and 25-hydroxyvitamin D3 (25-OH-D3) in a sample of human plasma. The system uses a BioTrap precolumn for the on-line sample cleanup. A sample of 1 ml of human plasma was treated with 2 ml of a mixture of ethanol–acetonitrile (2:1 (v/v)). Following centrifugation, the supernatant was evaporated to dryness under a stream of dry and pure nitrogen. The residue was reconstituted in 250 μL of a solution of methanol 5 mmol l−1 phosphate buffer, pH 6.5 (4:1 (v/v)), and a 200 μl aliquot of this solution was injected onto the BioTrap precolumn. After washing during 5 min with a mobile phase constituted by a solution of 6% acetonitrile in 5 mmol l−1 phosphate buffer, pH 6.5 (extraction mobile phase), the retained analytes were then transferred to the analytical column in the backflush mode. The analytical separation was then performed by reverse-phase chromatography in the gradient elution mode with the solvents A and B (Solvent A: acetonitrile–phosphate buffer 5 mmol l−1, pH 6.5; 20:80 (v/v); solvent B: methanol–acetonitrile–tetrahydrofuran, 65:20:15 (v/v)). The compounds of interest were detected at 265 nm. The method was linear in the range 3.0–32.0 ng ml−1 with a limit of quantification of 3.0 ng ml−1. Quantitative recoveries from spiked plasma samples were between 91.0 and 98.0%. In all cases, the coefficient of variation (CV) of the intra-day and inter-day-assay precision was ≤2.80%. The proposed method permitted the simultaneous determination of Vitamin D3 and 25-OH-D3 in 16 min, with an adequate precision and sensitivity. However, the overlap of the sample cleanup step with the analysis increases the sampling frequency to five samples h−1. The method was successfully applied for the determination of Vitamin D3 and 25-OH-D3 in plasma from 46 female volunteers, ranging from 50 to 94 years old. Vitamin D3 and 25-OH-D3 concentrations in plasma were found from 4.30–40.70 ng ml−1 (19.74 ± 9.48 ng ml−1) and 3.1–36.52 ng ml−1 (7.13 ± 7.80 ng ml−1), respectively. These results were in good agreement with data published by other authors.  相似文献   

6.
Arancibia V  López A  Zúñiga MC  Segura R 《Talanta》2006,68(5):1567-1573
The separation of arsenic based on in situ chelation with ammonium diethyl dithiophosphate (ADDTP) has been carried out using methanol-modified supercritical CO2. Aliquots of extract were added to an electroanalytical cell and arsenic was determined by square wave cathodic stripping voltammetry (SWCSV) at a hanging mercury drop electrode (HMDE). Quantitative extractions of As(DDTP)3 were achieved when the experiments were carried out at a pressure of 2500 psi, a temperature of 90 °C, 2.0 mL of methanol, 20.0 min of static extraction and 5.0 min of dynamic extraction in the presence of 18 mg of ADDTP. Analysis of arsenic was made using 150 mg L−1 of Cu(II) in 1 M HCl solution as supporting electrolyte in the presence of ADDTP as ligand. Preconcentration was carried out by deposition at a potential of −0.50 V and the intermetallic compound CuxAsy was reduced at a potential of −0.77 to −0.82 V, depending on ligand concentration. The results showed that the presence of ligand plays an important role, increasing the method's sensitivity and preventing the oxidation of As(III). The calibration graph of the As(DDTP)3 solution was linear from 0.8 to 12.5 μg L−1 of arsenic (LOD 0.5 μg L−1, R = 0.9992, tacc = 60 s). The method was validated using carrot pulp spiked with arsenic solution. This method was applied to the determination of arsenic in samples of carrots, beets and irrigation water. Arsenic in beets was: skin 4.10 ± 0.18 mg kg−1; pulp 3.83 ± 0.19 mg kg−1 and juice 0.71 ± 0.09 mg L−1; arsenic in carrots was: skin 2.15 ± 0.09 mg kg−1; pulp 0.59 ± 0.11 mg kg−1 and juice 0.71 ± 0.03 mg L−1. Arsenic in water were: Chiu-Chiu 0.08 mg L−1, Inacaliri 1.12 mg L−1, and Salado river 0.17 ± 0.07 mg L−1.  相似文献   

7.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic (IC) detector for the speciation analysis of arsenic and selenium. The arsenic and selenium species studied included arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), selenite [Se(IV)] and selenate [Se(VI)]. Gradient elution using (NH4)2CO3 and methanol at pH 9 allowed the chromatographic separation of all species in less than 12 min. Effluents from the IC column were delivered to the nebulization system of ICP-DRC-MS for the determination of arsenic and selenium. The potentially interfering 38Ar40Ar+ and 40Ar40Ar+ at the selenium masses m/z 78 and 80 were reduced in intensity by approximately 3 orders of magnitude by using 0.6 mL min−1 CH4 as reactive cell gas in the DRC while an Rpq value of 0.3 was used. Meanwhile, arsenic was determined as the adduct ion 75As12CHH+ at m/z 89, which is more sensitive than 75As. The limits of detection for arsenic and selenium were in the range of 0.002–0.01 ng mL−1 and 0.01–0.02 ng mL−1, respectively, based on peak height. The relative standard deviation of the peak areas for five injections of 5 ng mL−1 As and Se mixture was in the range of 2–4%. The concentrations of arsenic and selenium species have been determined in urine samples collected locally. The major As and Se species in urines were AsB, DMA and probably selenosugar at concentration of 20–40, 15–19 and 17–31 ng mL−1, respectively. The recoveries were in the range of 94–105% for all the determinations. This method has also been applied to determine various arsenic compounds in two fish samples. In this study, a simple and rapid microwave-assisted extraction method was used for the extraction of arsenic compounds from fish. The arsenic species were quantitatively leached with an 80% v/v methanol solution in a focused microwave field during a period of 5 min.  相似文献   

8.
The photocatalytic removal of the insecticide fenitrothion (IUPAC name: O,O-dimethyl O-4-nitro-m-tolyl phosphorothioate), C9H12NO5PS, from water suspension of TiO2, was investigated by following the disappearance of the original substance along with the formation and disappearance of intermediates via recording NMR (1H and 31P) and UV spectra, as well as by pH measurements. Based on the obtained data, a possible reaction mechanism was proposed. It was found that 31P-NMR spectrometry can be successfully used to follow the kinetics of transforming organic into inorganic phosphorus in the course of the degradation (ka=9.2×10−7 mol dm−3 min−1, r=0.980 for the illumination period after 15 h). The rate of fenitrothion aromatic ring decomposition was followed by UV spectrometry during the illumination (ka=3.1×10−6 mol dm−3 min−1, r=0.989). The complete mineralization was attained after about 66 h of irradiation.  相似文献   

9.
N,O-carboxymethyl chitosan (NOCC) composite nanofiltration membranes having a polysulfone (PS) UF membrane as the substrate were prepared using a method of coating and cross-linking, in which a glutaraldehyde (GA) aqueous solution was used as the cross-linking agent. Attenuated total reflection infrared spectroscopy (ATR-IR) was employed to characterize the resulting membrane. The effects of the composition of the casting solution of the active layer, the concentration of the cross-linking agent, and the membrane preparation techniques on the performance of the composite membrane were investigated. At 13–15 °C and 0.40 MPa the rejections of the resulting membrane to Na2SO4 and NaCl solutions (1000 mg L−1) were 92.7 and 30.2%, respectively, and the permeate fluxes were 3.0 and 5.1 kg m−2 h−1, respectively. The rejection of this kind of membrane to the electrolyte solutions decreased in the order of Na2SO4, NaCl, MgSO4, and MgCl2. This suggests that the membrane active layer acquires a negative surface charge distribution by the adsorption of anions from the electrolyte solution and this charge distribution mainly determines the membrane performance.  相似文献   

10.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

11.
Kudo Y  Usami J  Katsuta S  Takeda Y 《Talanta》2003,59(6):1213-1218
Ion-pair formation constants (KMLA mol−1 dm3) of Na+– and K+–18-crown-6 ether (18C6) complexes with MnO4 in water (w) were determined potentiometrically at 25 °C. Simultaneously, extraction constants (Kex mol−2 dm6) of the permanganates with 18C6 from w into 1,2-dichloroethane at 25 °C were obtained from the spectrophotometric determination of distribution ratios of the permanganates. These Kex values were divided into KMLA and other three component equilibrium constants and thereby extraction-selectivity and -ability were discussed in comparison with corresponding metal picrate–18C6 extraction systems reported before.  相似文献   

12.
The hydrogen permeation and stability of tubular palladium alloy (Pd–23%Ag) composite membranes have been investigated at elevated temperatures and pressures. In our analysis we differentiate between dilution of hydrogen by other gas components, hydrogen depletion along the membrane length, concentration polarization adjacent to the membrane surface, and effects due to surface adsorption, on the hydrogen flux. A maximum H2 flux of 1223 mL cm−2 min−1 or 8.4 mol m−2 s−1 was obtained at 400 °C and 26 bar hydrogen feed pressure, corresponding to a permeance of 6.4 × 10−3 mol m−2 s−1 Pa−0.5. A good linear relationship was found between hydrogen flux and pressure as predicted for rate controlling bulk diffusion. In a mixture of 50% H2 + 50% N2 a maximum H2 flux of 230 mL cm−2 min−1 and separation factor of 1400 were achieved at 26 bar. The large reduction in hydrogen flux is mainly caused by the build-up of a hydrogen-depleted concentration polarization layer adjacent to the membrane due to insufficient mass transport in the gas phase. Substituting N2 with CO2 results in further reduction of flux, but not as large as for CO where adsorption prevail as the dominating flow controlling factor. In WGS conditions (57.5% H2, 18.7% CO2, 3.8% CO, 1.2% CH4 and 18.7% steam), a H2 permeance of 1.1 × 10−3 mol m−2 s−1 Pa−0.5 was found at 400 °C and 26 bar feed pressure. Operating the membrane for 500 h under various conditions (WGS and H2 + N2 mixtures) at 26 bars indicated no membrane failure, but a small decrease in flux. A peculiar flux inhibiting effect of long term exposure to high concentration of N2 was observed. The membrane surface was deformed and expanded after operation, mainly following the topography of the macroporous support.  相似文献   

13.
The cloud point extraction behaviors of lanthanoids(III) (Ln(III) = La(III), Eu(III) and Lu(III)) with and without di(2-ethylhexyl)phosphoric acid (HDEHP) using Triton X-100 were investigated. It was suggested that the extraction of Ln(III) into the surfactant-rich phase without added chelating agent was caused by the impurities contained in Triton X-100. The extraction percentage more than 91% for all Ln(III) metals was obtained using 3.0 × 10−5 mol dm−3 HDEHP and 2.0% (v/v) Triton X-100. From the equilibrium analysis, it was clarified that Ln(III) was extracted as Ln(DEHP)3 into the surfactant-rich phase. The extraction constant of Ln(III) with HDEHP and 2.0% (v/v) Triton X-100 were also obtained.  相似文献   

14.
Caffeine (1,3,7-trimethylxanthine), theobromine (3,7-dimethylxanthine) and theophylline (1,3-dimethylxanthine) are the most important naturally occurring methylxanthines. Caffeine is a constituent of coffee and other beverage and included in many medicines. Theobromine and theophylline are formed as metabolites of caffeine in humans, and are also present in tea, cocoa and chocolate products.

In order to improve the chromatographic resolution (Rs) with a good analysis time, experimental designs were applied for multivariate optimisation of the experimental conditions of an isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method used for the simultaneous determination of caffeine, theobromine and theophylline. The optimisation process was carried out in two steps using full three-level factorial designs. The factors optimised were: flow rate and mobile phase composition. Optimal conditions for the separation of the three methylxanthines were obtained using a mixture of water/ethanol/acetic acid (75:24:1%, v/v/v) as mobile phase and a flow rate of 1.0 mL min−1. The RP-HPLC/UV method was validated in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, recovery and the precision, calculated as relative standard deviation (R.S.D.). In these conditions, the LOD was 0.10 μg L−1 for caffeine, 0.07 μg L−1 for theobromine and 0.06 μg L−1 for theophylline. The proposed method is fast, requires no extraction step or derivatization and was suitable for quantification of these methylxanthines in coffee, tea and human urine samples.  相似文献   


15.
The anodization of mercury microelectrodes was investigated in synthetic samples containing several strong and weak electrolytes at different concentrations. In particular, the effects on mercury anodization due to the presence of NaOH, HClO4, NaCl, NaI, NaF, Na2SO4, NaHCO3, Na2CO3, tartaric and citric acids, were studied in solutions containing either each species or mixtures of them, and without addition of supporting electrolyte. Some of the electrode processes studied led to linear calibration plots e.g. 1 × 10−5 − 1 × 10−4M Cl, 1 × 10−6 − 1 × 10−5M I, 5 × 10−4 − 3 × 10−3M SO42−, 5 × 10−4 − 2 × 10−2M HCO3, with typical correlation coefficients of 0.998–0.999. The anodization of mercury microelectrodes was also investigated directly in wine, rain, tap and mineral water, without pretreatment and without addition of supporting electrolyte. In the real samples only the ions Cl and HCO3 could be quantified, and the values found were in agreement, within 3–5%, with the reference values obtained by using Italian standard methods for food.  相似文献   

16.
A bonded phase capillary column containing macrocyclic polyamine, [28]ane-N6O2 functional groups was used for the electrophoretic separation of arsenic, chromium and selenium species. A simple device interfacing this capillary electrochromatography (CEC) systems to an inductively coupled plasma mass spectrometer (ICPMS) is described. The dimension of the capillary column was 160 cm×100 μm i.d. To accommodate this electrophoretic separation, an auxiliary capillary was used with nitric acid (0.05 M) as makeup liquid. With the electrokinetic method at –20 kV, 20 s and a nebulizer gas flow rate of 1 l min−1, the sample injected was analyzed with an applied potential of −20 kV. The background electrolyte buffer for the separation of CrO42−–Cr3+ was phosphate (20 mM, pH 6.5). That for HAsO42−–Ph4As+ was pyromellitate (20 mM, pH 6.0) and for SeO42−–SeO32− was acetate (20 mM, pH 6.0). The role of the buffer’s anion was also discussed. The separation efficiency of the bonded phase was compared with the bare fused silica. Concentration detection limits for these metal ions were in the low ppb range. In addition, the matrix effect of the established system with the bonded phase was found smaller than that with the bare fused silica.  相似文献   

17.
Reactions of CoX2·6H2O (X = Cl, ClO4) with bis(3,5-dimethylpyrazolyl)methane (dmpzm) and formic acid, acetic acid, benzoic acid, salicylic acid, maleic acid, or fumaric acid under the presence of KOH solution produced a new family of Co(II)/dmpzm complexes, [Co(dmpzm)2L]X·nH2O (1: L = O2CH, X = Cl, n = 2; 2: L = OAc, X = Cl, n = 3; 3: L = benzoate, X = ClO4, n = 1/3; 4: L = salicylate, X = ClO4, n = 1/3) and [Co2(dmpzm)4L](ClO4)2·nSolv (5: L = maleate, n = 3, Solv = H2O; 6: L = fumarate, n = 2, Solv = MeOH). These compounds were structurally characterized by elemental analysis, IR spectroscopy, and single-crystal X-ray diffraction. Compounds 1–4 are mononuclear while 5–6 are binuclear. Each cobalt atom of 1–6 is hexacoordinate, with a distorted octahedral CoN4O2 coordination geometry incorporating two N,N′-bidentate dmpzm ligands and one O,O′-bidentate carboxylate ligand. There are rich intra- and intermolecular hydrogen bonds in the crystals of 1–6, thereby forming either 2D hydrogen-bonded networks (1 and 2) or 3D hydrogen-bonded networks (3–6). In addition, the thermal behaviors of 1–6 were also investigated.  相似文献   

18.
[Re2(Ala)4(H2O)8](ClO4)6 (Re=Eu, Er; Ala=alanine) were synthesized, and the low-temperature heat capacities of the two complexes were measured with a high-precision adiabatic calorimeter over the temperature range from 80 to 370 K. For [Eu2(Ala)4(H2O)8](ClO4)6, two solid–solid phase transitions were found, one in the temperature range from 234.403 to 249.960 K, with peak temperature 243.050 K, the other in the range from 249.960 to 278.881 K, with peak temperature 270.155 K. For [Er2(Ala)4(H2O)8](ClO4)6, one solid–solid phase transition was observed in the range from 270.696 to 282.156 K, with peak temperature 278.970 K. The molar enthalpy increments, ΔHm, and entropy increments,ΔSm, of these phase transitions, were determined to be 455.6 J mol−1, 1.87 J K−1 mol−1 at 243.050 K; 2277 J mol−1, 8.43 J K−1 mol−1 at 270.155 K for [Eu2(Ala)4(H2O)8](ClO4)6; and 4442 J mol−1, 15.92 J K−1 mol−1 at 278.970 K for [Er2(Ala)4(H2O)8](ClO4)6. Thermal decompositions of the two complexes were investigated by use of the thermogravimetric (TG) analysis. A possible mechanism for the thermal decomposition is suggested.  相似文献   

19.
Bismuth as BiCl4 and BH4 ware successively retained in a column (150 mm × 4 mm, length × i.d.) packed with Amberlite IRA-410 (strong anion-exchange resin). This was followed by passage of an injected slug of hydrochloric acid resulting in bismuthine generation (BiH3). BiH3 was stripped from the eluent solution by the addition of a nitrogen flow and the bulk phases were separated in a gas–liquid separator. Finally, bismutine was atomized in a quartz tube for the subsequent detection of bismuth by atomic absorption spectrometry. Different halide complexes of bismuth (namely, BiBr4, BiI4 and BiCl4) were tested for its pre-concentration, being the chloride complexes which produced the best results. Therefore, a concentration of 0.3 mol l−1 of HCl was added to the samples and calibration solutions. A linear response was obtained between the detection limit (3σ) of 0.225 and 80 μg l−1. The R.S.D.% (n = 10) for a solution containing 50 μg l−1 of Bi was 0.85%. The tolerance of the system to interferences was evaluated by investigating the effect of the following ions: Cu2+, Co2+, Ni2+, Fe3+, Cd2+, Pb2+, Hg2+, Zn2+, and Mg2+. The most severe depression was caused by Hg2+, which at 60 mg l−1 caused a 5% depression on the signal. For the other cations, concentrations between 1000 and 10,000 mg l−1 could be tolerated. The system was applied to the determination of Bi in urine of patients under therapy with bismuth subcitrate. The recovery of spikes of 5 and 50 μg l−1 of Bi added to the samples prior to digestion with HNO3 and H2O2 was in satisfactory ranges from 95.0 to 101.0%. The concentrations of bismuth found in six selected samples using this procedure were in good agreement with those obtained by an alternative technique (ETAAS). Finally, the concentration of Bi determined in urine before and after 3 days of treatment were 1.94 ± 1.26 and 9.02 ± 5.82 μg l−1, respectively.  相似文献   

20.
Polyallylamine (PAAm) was synthesized by free radical polymerization and characterized by Fourier transform infrared resonance (FT-IR) spectroscopy, hydrogen nuclear magnetic resonance (1H NMR) spectroscopy and differential scanning calorimetry (DSC). The composite membranes were prepared by using PAAm–poly(vinyl alcohol) (PVA) blend polymer as the separation layer and polysulfone (PSF) ultrafiltration membranes as the support layer. The surface and cross-section morphology of the membrane was inspected by environmental scanning electron microscopy (ESEM). The gas transport property of the membranes, including gas permeance, flux and selectivity, were investigated by using pure CO2, N2, CH4 gases and CO2/N2 gas mixture (20 vol% CO2 and 80 vol% N2) and CO2/CH4 gas mixture (10 vol% CO2 and 90 vol% CH4). The plots of gas permeance or flux versus feed gas pressure imply that CO2 permeation through the membranes follows facilitated transport mechanism whereas N2 and CH4 permeation follows solution–diffusion mechanism. Effect of PAAm content in the separation layer on gas transport property was investigated by measuring the membranes with 0–50 wt% PAAm content. With increasing PAAm content, gas permeance increases initially, reaches a maximum, and then decreases gradually. For CO2/N2 gas mixture, the membranes with 10 wt% PAAm content show the highest CO2 permeance of about 1.80 × 10−5 cm3 (STP) cm−2 s−1 KPa−1 and CO2/N2 selectivity of 80 at 0.1 MPa feed gas pressure. For CO2/CH4 gas mixture, the membranes with 20 wt% PAAm content display the highest CO2 permeance of about 1.95 × 10−5 cm3 (STP) cm−2 s−1 KPa−1 and CO2/CH4 selectivity of 58 at 0.1 MPa feed gas pressure. In order to explore the possible reason of gas permeance varying with PAAm content, the crystallinity of PVA and PAAm–PVA blend polymers was measured by X-ray diffraction (XRD) spectra. The experimental results show an inverse relationship between crystallinity and gas permeance, e.g., a minimum crystallinity and a maximum CO2 permeance are obtained at 20 wt% PAAm content, indicating that the possibility of increasing CO2 permeance with PAAm content due to the increase of carrier concentration could be weakened by the increase of crystallinity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号