首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
A novel and simple method based on solidified floating organic drop microextraction followed by high‐performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1‐undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0–300.0, 0.3–200.0, and 1.0–200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples.  相似文献   

2.
A novel, simple, and rapid vortex‐assisted hollow‐fiber liquid‐phase microextraction method was developed for the simultaneous extraction of albendazole and triclabendazole from various matrices before their determination by high‐performance liquid chromatography with fluorescence detection. Several factors influencing the microextraction efficiency including sample pH, nature and volume of extraction solvent, ionic strength, vortex time, and sample volume were investigated and optimized. Under the optimal conditions, the limits of detection were 0.08 and 0.12 μg/L for albendazole and triclabendazole, respectively. The calibration curves were linear in the concentration ranges of 0.3–50.0 and 0.4–50.0 μg/L with the coefficients of determination of 0.9999 and 0.9995 for albendazole and triclabendazole, respectively. The interday and intraday relative standard deviations for albendazole and triclabendazole at three concentration levels (1.0, 10.0, and 30.0 μg/L) were in the range of 6.0–11.0 and 5.0–7.9%, respectively. The developed method was successfully applied to determine albendazole and triclabendazole in water, milk, honey, and urine samples.  相似文献   

3.
In this work, a simple and miniaturized solid-phase extraction device was constructed by connecting a commercial nylon needle filter to a syringe, which was applied for extracting 1-hydroxypyrene from a urine sample via hydrophobic and hydrogen bond interactions. The nylon membrane in the needle filter acted as the solid-phase extraction adsorbent, meanwhile, it filtered the particles in the urine sample. To obtain high extraction efficiency, key parameters influencing extraction recovery were investigated. The entire pretreatment process was accomplished within 5 min under the optimal conditions. By coupling high-performance liquid chromatography–ultraviolet, a rapid, low-cost, and convenient nylon needle filter-based method was established for the analysis of 1-hydroxypyrene in a complex urine matrix. Within the linearity range of 0.2–1000 μg/L, the method exhibited a satisfactory correlation coefficient (R = 0.9999). The limit of detection was 0.06 μg/L, and the recoveries from urine sample spiked with three concentrations (5, 20, and 100 μg/L) ranged from 105.8% to 113.1% with the relative standard deviations less than 6.7% (intra-day, n = 6) and 8.9% (inter-day, n = 4). Finally, the proposed method was successfully applied for detecting 1-hydroxypyrene in urine samples from college students, smokers, gas station workers, and chip factory workers. The detected concentration in actual urine samples ranged from 0.46 to 5.26 μg/L. Taken together, this simple and cost-effective nylon needle filter-based solid-phase extraction device showed an excellent application potential for pretreating hydrophobic analytes from aqueous samples.  相似文献   

4.
A magnetic solid‐phase extraction sorbent of polypyrrole/silica/magnetite nanoparticles was successfully synthesized and applied for the extraction and preconcentration of sulfonamides in water samples. The magnetite nanoparticles provided a simple and fast separation method for the analytes in water samples. The silica coating increased the surface area that helped to increase the polypyrrole layer. The polypyrrole‐coated silica provided a high extraction efficiency due to the π–π and hydrophobic interactions between the polypyrrole and sulfonamides. Several parameters that affected the extraction efficiencies, i.e. the amount of sorbent, pH of the sample, extraction time, extraction temperature, ionic strength, and desorption conditions were investigated. Under the optimal conditions, the method was linear over the range of 0.30–200 μg/L for sulfadiazine and sulfamerazine, and 1.0–200 μg/L for sulfamethazine and sulfamonomethoxine. The limit of detection was 0.30 μg/L for sulfadiazine and sulfamerazine and 1.0 μg/L for sulfamethazine and sulfamonomethoxine. This simple and rapid method was successfully applied to efficiently extract sulfonamides from water samples. It showed a high extraction efficiency for all tested sulfonamides, and the recoveries were in the range of 86.7–99.7% with relative standard deviations of < 6%.  相似文献   

5.
黄维  丁俊  冯钰锜 《分析化学》2012,40(6):830-834
采用磁固相萃取-高效液相色谱-荧光检测方法(MSPE-HPLC-FD)分析了尿样中芘代谢物1-羟基芘(1-Hydroxyperene 1-OHP).2mL尿样以0.1 mol/L醋酸钠溶液(pH 4.5)稀释至4 mL,酶水解后,再以0.1 mol/L醋酸钠溶液(pH 5.0)稀释至10mL,采用十八烷基膦酸改性的磁性介孔纳米粒子(50 mg)为萃取介质,对其进行MSPE富集,涡旋萃取1 min,甲醇解吸3min.解吸液经氮气吹干重新定容后,进行液相色谱分析.本方法在0.01~ 1.00 μg/L范围内线性良好(R2=0.9996);检出限为0.001μg/L日内相对标准偏差小于9.7%(n=5),日间相对标准偏差小于12.9%.将本方法应用于多个人体尿液样品中1-OHP含量的检测,结果满意.为确保结果的科学性和可靠性,测定结果用尿肌酐含量进行了归一化.  相似文献   

6.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied in rat urine for the extraction and determination of tetrahydropalmatine (THP) and tetrahydroberberine (THB), both active components in Rhizoma corydalis. Various parameters affecting the extraction efficiency, such as the type and volume of extraction and dispersive solvent, pH, etc. were evaluated. Under the optimal conditions (extraction solvent: 37 μL of chloroform, dispersive solvent: 100 μL of methanol, alkaline with 100 μL of 1 mol/L NaOH, and without salt addition), the enrichment factors of THP and THB were more than 30. The extraction recoveries were 69.8-75.8% and 72.7-77.6% for THP and THB in rat urine, respectively. Both THP and THB showed good linearity in the range of 0.025-2.5 μg/mL, and the limit of quantification was 0.025 μg/mL (S/N=10, n=6). The intra-day and inter-day precision of THP and THB were <12.6%. The relative recoveries ranged from 95.5 to 107.4% and 96.8 to 100.9% for THP and THB in rat urine, respectively. The method has been successfully applied to rat urine samples. The results demonstrated that DLLME is a very simple, rapid and efficient method for the extraction and preconcentration of THP and THB from urine samples.  相似文献   

7.
Ion-pair based hollow fiber liquid phase microextraction (IP-HFLPME) coupled with high performance liquid chromatography-ultraviolet detection was applied for the preconcentration and determination of methimazole in biological samples and animal feed. Optimization of the conditions for the high extraction efficiency was studied simultaneously using the experimental design. For the first step, the Plackett-Burman design was applied to screen the significant factors on the extraction efficiency. Central composite design (CCD) was then used for the optimization of important factors and the response surface equations were obtained. The optimum experimental conditions were donor phase pH, 12.2; extraction temperature, 45°C; extraction time, 50 min; sodium perchlorate concentration, 1.5 M; cetyltrimethylammonium bromide concentration, 0.65 mM, and without salt addition in donor phase. The limit of detection and the dynamic linear range were in the range of 0.1-0.7 μg L(-1) and 0.5-1000 μg L(-1) , respectively. Preconcentration factors were obtained in the range of 93-155 in different matrices. Finally, the performance of the proposed method was tested for the determination of trace amounts of methimazole in plasma, urine, bovine milk, and animal feed samples, and satisfactory results were obtained (RSDs < 7.1%).  相似文献   

8.
用分散液液微萃取-气相色谱/质谱法测定水样中的16种多环芳烃(PAHs)。通过实验确定最佳萃取条件为:20μL四氯化碳作萃取剂,1.0 mL乙腈作分散剂,超声萃取1 min。在优化条件下,多环芳烃的富集倍数达到216~511,方法在0.05~50μg/L范围内呈良好的线性关系,相关系数(R2)在0.9873~0.9983之间,检出限为0.0020~0.14μg/L。相对标准偏差(RSD)在3.82%~12.45%(n=6)之间。该方法成功用于实际水样中痕量多环芳烃的测定。  相似文献   

9.
A porous and highly efficient polyaniline‐based solid‐phase microextraction (SPME) coating was successfully prepared by the electrochemical deposition method. A method based on headspace SPME followed by HPLC was established to rapidly determine trace chlorophenols in water samples. Influential parameters for the SPME, including extraction mode, extraction temperature and time, pH and ionic strength procedures, were investigated intensively. Under the optimized conditions, the proposed method was linear in the range of 0.5–200 μg/L for 4‐chlorophenol and 2,4,6‐trichlorophenol, 0.2–200 μg/L for 2,4‐dichlorophenol and 2–200 μg/L for 2,3,4,6‐tetrachlorophenol and pentachlorophenol, with satisfactory correlation coefficients (>0.99). RSDs were <15% (n = 5) and LODs were relatively low (0.10–0.50 μg/L). Compared to commercial 85 μm polyacrylate and 60 μm polydimethylsiloxane/divinylbenzene fibers, the homemade polyaniline fiber showed a higher extraction efficiency. The proposed method has been successfully applied to the determination of chlorophenols in water samples with satisfactory recoveries.  相似文献   

10.
环境水样中百菌清残留的单滴微萃取-反相液相色谱测定   总被引:7,自引:1,他引:6  
应用单滴微萃取(SDME)-反相液相色谱(RPLC)检测了环境水样中的百菌清残留.优化了单滴微萃取条件:环己烷萃取剂6 μL、单滴体积2 μL、搅拌速率350 r/min、萃取时间40 min、水溶液温度35 ℃、无盐度.水样经单滴微萃取后,使用Hypersil C18柱反相液相色谱分离测定百菌清.反相液相色谱条件:100%甲醇流动相、流速1.0 mL/min、柱温25 ℃、224 nm检测.方法的线性范围、检出限、相对标准偏差和富集倍数分别为1.0 ~50 μg/L、0.02 μg/L、6.1%和427倍.采用该法对环境水样中的百菌清残留进行了测定,环境水样的加标回收率为98% ~106%.  相似文献   

11.
建立了高效液相色谱-电喷雾串联质谱同时检测尿液和胃液中12种有毒生物碱的方法.优化了提取条件及色谱-质谱条件,并考察了基质效应的影响,探讨了质谱碎裂机理.尿液和预先调节至中性的胃液经硼砂-NaOH缓冲液(pH 9.6)碱化,乙酸乙酯液液萃取,采用电喷雾电离(ESI+)、多反应监测(MRM)方式,可同时对黄华碱、倒千里光碱、山莨菪碱、钩吻碱、芦竹碱、哈尔碱、吐根碱、血根碱、吴茱萸碱、吴茱萸次碱、雷公藤吉碱和雷公藤次碱12种有毒生物碱进行定性和定量分析.在优化的条件下,12种成分分别在0.5~200 μg/L、1~200 μg/L和5~200μg/L范围内线性关系良好,尿液中除黄华碱和山莨菪碱外,各生物碱的回收率为61.9%~119.1%,胃液中各生物碱回收率为61,0%~1102%,精密度RSD< 15%.检出限(LOD)为0.1~0 Sμμg/L,定量限(LOQ)为0.5~5.0 μg/L,时回收率不高的生物碱可通过空白基质配制标样校正,满足定量分析的要求.本方法操作简便、快捷、灵敏度高,适用于中毒患者尿液和胃液中有毒生物碱成分的检测.  相似文献   

12.
A simple, sensitive, and inexpensive single drop liquid‐liquid‐liquid microextraction combined with isocratic RP‐HPLC and UV detection was developed for the determination of anti‐malaria drug, chloroquine. The target compound was extracted from alkaline aqueous sample solution (adjusted to 0.5 mol/L sodium hydroxide) through a thin layer of organic solvent membrane and back‐extracted to an acidic acceptor drop (adjusted to 0.02 mol/L phosphoric acid) suspended on the tip of a 25 μL HPLC syringe in the organic layer. This syringe was also used for direct injection after extraction. The linear range was 1–200 μg/L. The LOD and LOQ were 0.3 and 1.0 μg/L, respectively. Intra‐and inter‐day precisions were less than 2.0 and 2.3%, respectively. The real samples were successfully analyzed using the proposed method. The recoveries of spiked samples were more than 94.6%.  相似文献   

13.
建立了三相中空纤维膜液相微萃取-高效液相色谱(HF-LPME-HPLC)方法,用于分析测定水中痕量双酚A的含量.设计了三相中空纤维膜液相微萃取系统,优化的HP-LPME最佳萃取条件为:萃取剂为正辛醇,接受相NaOH浓度为0.09 mol/L,样品溶液pH=4.0,NaC1加入量为30 g/L,搅拌速度为900 r/min,萃取时间为60 min.萃取后取20 μL接受相进行色谱分析.在最佳萃取条件下,方法的线性范围为0.5~200 μg/L(r> 0.999),检出限(信噪比为3)为0.2 μg/L;富集因子为241;方法RSD<3.2% (n=3).在实际环境水样中添加5,20和50μg/L的双酚A标准物质,加标平均回收率为92.8%~101.9%.表明本方法可用于水中痕量双酚A的快速准确测定.  相似文献   

14.
Magnetite nanoparticles incorporated into alginate beads and coated with a polypyrrole adsorbent were prepared (polypyrrole/Fe3O4/alginate bead) and used as an effective magnetic solid‐phase extraction sorbent for the extraction and enrichment of endocrine‐disrupting compounds (estriol, β‐estradiol and bisphenol A) in water samples. The determination of the extracted endocrine‐disrupting compounds was performed using high‐performance liquid chromatography with a fluorescence detector. The effect of various parameters on the extraction efficiency of endocrine disrupting compounds were investigated and optimized including the type and amount of sorbent, sample pH, extraction time, stirring speed, and desorption conditions. Under optimum conditions, the calibration curves were linear in the concentration range of 0.5–100.0 μg/L, and the limit of detection was 0.5 μg/L. The developed method showed a high extraction efficiency, the recoveries were in the range of 90.5 ± 4.1 to 98.2 ± 5.5%. The developed sorbent was easy to prepare, was cost‐effective, robust, and provided a good reproducibility (RSDs < 5%), and could be reused 16 times. The developed method was successfully applied for the determination of endocrine‐disrupting compounds in water samples.  相似文献   

15.
In this study, a simple and rapid extraction method based on the application of polypyrrole‐coated Fe3O4 nanoparticles as a magnetic solid‐phase extraction sorbent was successfully developed for the extraction and preconcentration of trace amounts of formaldehyde after derivatization with 2,4‐dinitrophenylhydrazine. The analyses were performed by high‐performance liquid chromatography followed by UV detection. Several variables affecting the extraction efficiency of the formaldehyde, i.e., sample pH, amount of sorbent, salt concentration, extraction time and desorption conditions were investigated and optimized. The best working conditions were as follows: sample pH, 5; amount of sorbent, 40 mg; NaCl concentration, 20% w/v; sample volume, 20 mL; extraction time, 12 min; and 100 μL of methanol for desorption of the formaldehyde within 3 min. Under the optimal conditions, the performance of the proposed method was studied in terms of linear dynamic range (10–500 μg/L), correlation coefficient (R2 ≥ 0.998), precision (RSD% ≤ 5.5) and limit of detection (4 μg/L). Finally, the developed method was successfully applied for extraction and determination of formaldehyde in tap, rain and tomato water samples, and satisfactory results were obtained.  相似文献   

16.
Monolithic fibers were synthesized and applied for the solid‐phase microextraction and determination of chlorophenols in environmental water samples by coupling with HPLC. The fibers were prepared by copolymerization of vinylimidazole and ethylene dimethacrylate as functional monomer and cross‐linker, respectively. The effect of the preparation conditions of monolithic fibers on the extraction efficiencies was investigated in detail. Several characteristic techniques, such as elemental analysis, infrared spectroscopy, mercury‐intrusion porosimetry, and SEM were used to characterize the monolithic material. The effect of the extraction parameters, including desorption solvent, extraction and desorption time, pH values, and ionic strength in sample matrix on the extraction performance was investigated thoroughly. Under the improved extraction conditions, the linear ranges of 2‐chlorophenol, 2,4‐dichlorophenol and pentachlorophenol were 1.0–200 μg/L and 2.0–200 μg/L for 2,4,6‐trichlorophenol. The detection limits (S/N = 3) were in the range of 0.16–0.45 μg/L, the RSDs for intraday and interday precisions were <7.0%. Finally, the proposed method was successfully used to detect different environmental water samples. The recoveries of spiked water samples were ranged from 90.0 to 115%. At the same time, satisfactory repeatability was achieved with RSDs < 9.0%.  相似文献   

17.
Ultrasound-assisted dispersive liquid-liquid microextraction (UDLLME) and simultaneous derivatization followed by GC-MS was developed for the analysis of four aldehydes including acetaldehyde (ACE), propionaldehyde (PRO), butyraldehyde (BUT) and valeraldehyde (VAL) in water samples. In the proposed method, the aldehydes were derivatized with O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) and extracted by UDLLME in aqueous solution simultaneously; finally, the derivatives were analyzed by GC-MS. The experimental parameters were investigated and the method validations were studied. The optimal conditions were: aqueous sample of 5 mL, PFBHA of 50 μL, 1.0 mL ethanol (disperser solvent) containing 20 μL chlorobenzene (extraction solvent), ultrasound time of 2 min and centrifuging time of 3 min at 6000 rpm. The proposed method provided satisfactory precision (RSD 1.8-10.2%), wide linear range (0.8-160 μg/L), good linearity (R(2) 0.9983-0.9993), good relative recovery (85-105%) and low limit of detection (0.16-0.23 μg/L). The proposed method was successfully applied for the analysis of aldehydes in water samples. The experimental results showed that the proposed method was a very simple, rapid, low-cost, sensitive and efficient analytical method for the determination of trace amount of aldehydes in water samples.  相似文献   

18.
浊点萃取-火焰原子吸收光谱法测定样品中的痕量钴   总被引:3,自引:0,他引:3  
研究了基于表面活性剂Triton X-114和络合剂吡咯烷二硫代氨基甲酸铵(APDC)浊点萃取钴的样品前处理方法.优化了浊点萃取条件参数,包括pH值、Triton X-114用量、APDC浓度、平衡温度及时间等,建立了浊点萃取-火焰原子吸收光谱法测定痕量钴的方法.该法的检测限(3σ)为2.6μg/L,相对标准偏差RSD为6.2%(n=7,c=200μg/L).该法成功地应用于海带、维生素B12注射液等样品中钴的测定.  相似文献   

19.
A simple, environmentally friendly, and efficient method, based on hollow‐fiber‐supported liquid membrane microextraction, followed by high‐performance liquid chromatography has been developed for the extraction and determination of amlodipine (AML) and atorvastatin (ATO) in water and urine samples. The AML in two‐phase hollow‐fiber liquid microextraction is extracted from 24.0 mL of the aqueous sample into an organic phase with microliter volume located inside the pores and lumen of a polypropylene hollow fiber as acceptor phase, but the ATO in three‐phase hollow‐fiber liquid microextraction is extracted from aqueous donor phase to organic phase and then back‐extracted to the aqueous acceptor phase, which can be directly injected into the high‐performance liquid chromatograph for analysis. The preconcentration factors in a range of 34–135 were obtained under the optimum conditions. The calibration curves were linear (R2 ≥ 0.990) in the concentration range of 2.0–200 μg/L for AML and 5.0–200 μg/L for ATO. The limits of detection for AML and ATO were 0.5 and 2.0 μg/L, respectively. Tap water and human urine samples were successfully analyzed for the existence of AML and ATO using the proposed methods.  相似文献   

20.
建立了分子印迹固相萃取结合气相色谱-质谱测定猪尿中β-受体激动剂氯丙那林、马步特罗、克伦特罗、莱克多巴胺的方法.应用分子印迹柱富集并净化猪尿液中4种β-受体激动剂,比较了分子印迹固相萃取与常规固相萃取的净化效果.通过BSTFA-1% TMS硅烷化衍生,氘代克伦特罗和氘代莱克多巴胺为校正内标,气相色谱-质谱测定.在优化条...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号