首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Diagnosis of copper ions in vascular tracts using a fluorine-doped carbon nanotube sensor
Authors:Ly Suw Young
Institution:

aBiosensor Research Institute, Seoul National University of Technology, 172, Gongreung 2-dong Nowon-gu, Seoul 139-743, South Korea

Abstract:The voltammetric assay of Cu(II) was investigated using a carbon nanotube electrode (CNE) and fluorine immobilized onto a carbon nanotube electrode (FCNE) in cyclic voltammetry (CV), square-wave (SW) stripping voltammetry, and chronoamperometry. Optimum SW conditions were attained at working ranges of 0.01–0.11 ng L−1 Cu(II) (11 points), and a relative standard deviation of 1.68% (RSD, n = 15) was observed at 10.0 μg L−1 Cu(II). Within a 200 s accumulation time, detection limit of 0.006 μg L−1 was attained. The life span of each electrode was more than 1 month. The sensor was applied to tap water, blood, and rat tail vascular (in vivo). It was found that the sensor could be used with an interface system in the assay of live cells and non-treated blood.
Keywords:Copper  Fluorine  Voltammetry  Vascular tract  Multi-walled carbon nanotubes (MWCNTs)  Chemically modified electrodes (CMEs)
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号