首页 | 本学科首页   官方微博 | 高级检索  
     检索      

混合固定相电中溶质的输运特征
引用本文:张维冰,张丽华,张凌怡,张玉奎.混合固定相电中溶质的输运特征[J].色谱,2002,20(4):295-298.
作者姓名:张维冰  张丽华  张凌怡  张玉奎
作者单位:中国科学院大连化学物理研究所,国家色谱研究分析中心,辽宁,大连,116011
基金项目:国家重大基础研究基金项目 (973 ) (0 0 1CB5 10 2 0 2 )
摘    要: 以离子交换和反相固定相构成的混合固定相电中 ,溶质迁移在受到疏水、离子交换作用的同时 ,对于带电溶质而言 ,还受到电泳迁移的影响。根据离子独立迁移原理 ,结合过程中的多种相互作用 ,得到了描述溶质表观迁移速率与其各形态迁移速率、各种相互作用之间相互关系的理论表达式 ;讨论了混合模式电中流动相的 pH及其中的有机调节剂浓度、混合固定相配比等对电渗流的影响及不同形态溶质在柱内的输运特征。结果表明 ,在电中采用混合固定相可以在较大的 pH和有机调节剂浓度范围内得到较强且稳定的电渗流。

关 键 词:毛细管电  混合固定相  输运  溶质
文章编号:1000-8713(2002)04-0295-04
修稿时间:2002年3月31日

Transfer of Solutes in Capillary Electrochromatography with Mixed-Mode Stationary Phase
ZHANG Wei bing,ZHANG Li hua,ZHANG Ling yi,ZHANG Yu kui.Transfer of Solutes in Capillary Electrochromatography with Mixed-Mode Stationary Phase[J].Chinese Journal of Chromatography,2002,20(4):295-298.
Authors:ZHANG Wei bing  ZHANG Li hua  ZHANG Ling yi  ZHANG Yu kui
Institution:National Chromatographic R. & A. Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116011, China.
Abstract:In capillary electrochromatography with the mixed mode stationary phase, while the transfer of solutes could be controlled by the contributions of chromatography (reversed phase and ion exchange), the transfer of charged solutes could be influenced by electrophoresis transfer. According to the principle of ion independent transfer and several kinds of interaction between solute, mobile phase, and stationary phase, an theoretical expression was derived to describe the relationship among the apparent transfer velocity of solute, the transfer velocities in various forms and the diversified interactions. The studies focused on the influence of various parameters (e.g., pH, organic modifier content, stationary phase proportion) and the transfer characters of various solutes in the mixed-mode capillary electroosmotic chromatography (CEC). These results demonstrate that electroosmotic flow in the mixed stationary phase electrochromatography are kept high and steady within wide ranges of pH and organic modifier content. The separation was affected by the pH through the change of the solutes conformation. The influence of neutral solutes by organic modifier complies with the rule of conventional reversed phase CEC. The separation of charged solutes was influenced evidently by the compete reagents which could improve the shape of the peak, but it was not so important as in the conventional ion exchange chromatography due to the adjustment by the function of electrophoresis.
Keywords:capillary electroosmotic chromatography  mixed  mode stationary phase  transfer  solute
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号