排序方式: 共有86条查询结果,搜索用时 16 毫秒
1.
Ferhat Sametoglu 《Optical Review》2006,13(5):326-337
Traceability in illuminance measurements at the National Metrology Institute of Turkey (TüBITAK-UME) was established in 2003
with a detector-based realization. The new measurement technique was developed for the determination of illuminance responsivity
and upgrating of the illuminance scale. The unit of the illuminance responsivity, in A/lx, was measured with an expanded uncertainty
of 0.2% (k = 2) by supplying using the developed scanning technique for the calculation of color correction factor. The surface of a
radiometer was scanned using a double-monochromator facility upgraded with an x-y scanning system. The illuminance responsivity
as a function of bandpass and temperature were also investigated in this study.
To use a radiometer in the photometric applications of metrology, a light-sensitive device, a so-called trap detector, was
characterized by measuring the absolute responsivity, the non-linearity, and spatial non-uniformity. 相似文献
2.
Liangqi Gui Wei Guo ZuYin Zhang Shu Duan 《International Journal of Infrared and Millimeter Waves》2004,25(1):63-70
The image displaying methods used in a millimeter wave radiometric imaging system have great influence on its imaging quality. In order to obtain high quality millimeter wave radiometric images, intensive studies on the image displaying methods are needed. This paper describes the image displaying method of Ground-based 8mm Millimeter Wave Radiometric Imaging (GMWRI) system and compares two different image displaying methods. The experimental results prove the unequal size element arc displaying method fits GMWRI system better. 相似文献
3.
O?uz??elikelEmail author ?zcan?Bazkir Mehmet?Kü?üko?lu Farhad?Samedov 《Optical and Quantum Electronics》2005,37(6):529-543
This paper covers the absolute spectral power responsivity calibration of spectralon-coated Integrating Sphere Radiometer (ISR) equipped with 3 mm diameter InGaAs photodiode to be used as a transfer standard in fiber optic power measurements against Electrical Substitution Cryogenic Radiometer (ESCR) in Optics Laboratory of National Metrology Institute (TUBITAK UME) of Turkey. The initial uncertainty arising from the use of the Electrically Calibrated Pyroelectric Radiometer (ECPR) as a transfer standard in radiometric scale is 0.5% (k=2), which particularly comes from irregularity in the surface homogeneity of ECPR. In order to eliminate the ECPR step as well as its initial uncertainty contribution in fiber optic power measurements, the calibration application herein was carried out. Moreover power stabilization measurements of DFB laser sources at both 1309.1 nm and 1549.0 nm, the beam size determinations, and spectral analyses of these laser sources as well as spatial and angular dependence of spectral responsivities of the ISR were presented in this paper. The total expanded uncertainties were calculated as 0.283% and 0.315% in the determination of absolute spectral power responsivities of the ISR for 1309.1 nm and 1549.0 nm wavelengths respectively (k=2). 相似文献
4.
为了测量 HL-2M 装置中的电子温度剖面分布,研制了一套扫频电子回旋辐射(SECE)系统。该系统
能够测量装置中心纵场大小在 1.4~2.2T 时的等离子体电子温度。采用扫频外差接收的方式,径向空间分辨达到
2.5cm,时间分辨达到 1ms。接收机前端的准光学系统采用两级金属反射镜的配置,系统能够接收的最小极向光
斑的直径为 1.5cm(波数 kθ<4.2rad·cm-1)。系统的频带范围覆盖 33~110GHz,采用 VCO 作为本振源,双边带混频
输出中频信号。后端首次采用高性能对数检波器解调中频,能直接对-70dBm 的微弱信号进行检测,输入-输出工
作区间的动态范围达到 45dB 以上。在实验期间,成功测量到了等离子体中电子逃逸以及回旋辐射产生的信号。 相似文献
5.
光谱辐照度是光谱辐射计量中最基本的参数,是研究各种辐射源及光电探测器特性的重要依据。为提高光谱辐照度的测量精度和量值溯源等问题,国防科工委光学计量一级站采用BB3200K高温黑体作为基准的辐射源,以新型辐射测温法为基础,通过一系列光辐射理论和几何原理推导出辐射温度与辐射光功率之间的关系;通过对光辐射功率的绝对测量,并结合低温辐射计,从而完成了光谱辐照度量值的精度测量。该理论奠基了以探测器为基础的新的光辐射量传体系。主要介绍了在光谱辐照度标准装置的项目中复现光谱辐照度所建立的数学模型及新的测试方法,给出了测量结果,并简要介绍了基于该理论的测量装置的组成及原理。 相似文献
6.
John A. Taylor Peter E. Tannenwald Neal R. Erickson Gerald F. Dionne James F. Fitzgerald 《International Journal of Infrared and Millimeter Waves》1985,6(8):687-695
A compact, solid state submillimeter-wave heterodyne radiometer has been developed and was used to measure spectral characteristics of a water vapor jet in a space simulation chamber. Features of the 557 GHz water vapor line profile were observed in significantly greater detail than in previous experiments through an increased sensitivity and improved frequency resolution (600 kHz). The local oscillator of the radiometer consisted of a frequency multiplication chain which was driven by an InP Gunn oscillator at 92.6 GHz, and which contained a frequency tripler and harmonic mixer in cascade. The front end of the receiver had a noise temperature of 4500 K (DSB) at 555 GHz, consumed 3 W and weighed 3 kg. This advance in technology is particularly relevant to submillimeter-wave radiometry from a space-based platform. 相似文献
7.
8.
9.
10.
纯引力轨道飞行器在精密导航、重力场测量以及基础科学研究等方面具有重要意义,辐射计效应是纯引力轨道验证质量的重要干扰力之一.针对内编队重力场测量系统,利用解析和数值计算相结合的方法,分析了内卫星辐射计效应与内编队系统参数的关系,并给出了适宜于工程计算的内卫星辐射计效应近似函数及其修正因子.分析可知,内卫星辐射计效应与腔体平均压力成正比,与腔体平均温度成反比;随腔体温差的增加而增加,随外卫星腔体半径的增加存在极小值,并且取极小值时外卫星腔体半径和内卫星半径比为常数1.189 4,这一常数是由内外卫星的球形腔体构型决定的,与腔体内温度和压力无关.当内外卫星半径比大于10时,可认为外卫星腔体充分大,此时内卫星辐射计效应与内卫星半径的平方近似成正比,随外卫星腔体半径的变化可忽略. 相似文献